Abstract
Background The growing demand for tooth replacement has increased the use of Ti dental implants the long-term success of which depends on stable osseointegration. However, this process can be compromised by bacterial biofilm formation on implant surfaces. To overcome this, a coating strategy was explored that combines magnesium—known for its bone-regenerative and antibacterial properties—in the form of nano-Mg(OH)2 with gelatin to slow magnesium degradation and support bone growth. This study evaluated the in vitro osteogenic potential and antibacterial activity of nano-Mg(OH)2–gelatin as coating material for Ti dental implant.
Methodology Pure Ti plates (1×1 cm) were coated via electrospinning for in vitro evaluation. Samples were divided into four groups: 0 (control), 4, 6, and 8% nano-Mg(OH)₂-gelatin coating. Coating morphology and thickness were analyzed using SEM. Mg ion release, pH, and surface hydrophilicity (contact angle) were measured. Biological assessments included MC3T3-E1 cell proliferation, alkaline phosphatase (ALP) activity, and antibacterial activity against Streptococcus mutans and Streptococcus sanguinis. Statistical analyses were performed using one- or two-way ANOVA (p=0.05). The optimal biologically compatible concentration of Mg(OH)2 was evaluated.
Result SEM revealed a uniform, spiderweb-like coating with ~110–120 µm thickness. The coatings showed an initial burst of Mg ion release, peaking at 24 hours, followed by a gradual decline up to 240 hours. Increasing Mg content enhanced surface hydrophilicity, with the 6% group showing optimal wettability. Increasing Mg content improved MC3T3-E1 cell proliferation, peaking at 8%, whereas ALP activity was enhanced in the 6% group. Moreover, the observed decrease in S. mutans and S. sanguinis colonies suggests the 6% concentration showed balance performance as coating.
Conclusion The nano-Mg(OH)₂-gelatin coating, particularly at 6% concentration, significantly enhanced the bioactivity of the Ti surface, showing dual-functional activity in vitro.
Keywords
Nano-magnesium hydroxide; Titanium implant; Osseointegration; Antibacterial coating; Gelatin
Introduction
Edentulism is a growing global health concern, particularly in aging populations, as it significantly impairs masticatory function and reduces quality of life. Common causes of edentulism include periodontitis, dental caries, trauma, developmental defects, and genetic disorders that induce tooth loss.1,2
Tooth replacement options for tooth loss include traditional removable dentures and dental implants. In recent years, implants have gained global popularity due to their high success rates, functional advantages, and increasing affordability.2,3 The global dental implant market, valued at approximately $9 billion in 2020, is projected to grow steadily, with high adoption rates expected in future.4,5 Titanium (Ti) remains the material of choice for dental implants due to its superior biocompatibility, mechanical strength, and corrosion resistance.6,7
The success of dental implants heavily relies on osseointegration, the direct structural and functional bond between bone and implant surface. Thus, preserving long-term implant stability and restoring oral function are crucial.8 However, the relatively low bioactivity of Ti may impair osseointegration and hinder the formation of direct bone-implant contact.8,9,10 Insufficient integration may promote fibrous tissue formation and create interfacial microenvironments that are more susceptible to bacterial adhesion and colonization, increasing vulnerability to infection and implant failure.11,12,13
Peri-implant infections, particularly peri-implant mucositis and peri-implantitis, are primarily caused by the accumulation of bacterial plaque biofilms on implant surfaces. Salivary protein adsorption and electrostatic interactions facilitate the rapid formation of these biofilms, which enable early colonizers such as Streptococcus mutans and Streptococcus sanguinis to rapidly adhere to implant surfaces.14,15,16 Persistent biofilm accumulation can induce peri-implant inflammation and contribute to progressive peri-implant bone loss. Biofilm accumulation is a major clinical risk factor for implant failure.17,18,19,20 Moreover, mechanical stress received by the implant may worsen the effect of biofilm by damaging implant surface and facilitating further bacterial colonization.21 Peri-implant mucositis manifests as reversible inflammation of the mucosal tissue, whereas peri-implantitis involves progressive bone loss and more intense inflammatory responses.22 Epidemiological data indicate that peri-implant mucositis affects 7-83% of patients, whereas peri-implantitis affects up to 70% of them.20
On the implant surface, osseointegration and biofilm formation are competing processes. To facilitate early osteoblast attachment and promote bone integration, reducing bacterial adhesion is essential.23 Thus, strategies that promote osseointegration and prevent bacterial colonization are crucial for improving implant longevity and lowering failure risk. Implant surface modification, particularly by applying bioactive coatings, has emerged as a promising approach to improve osteoconductive and antibacterial performance.24,25
Among the bioactive materials that could be applied to implant surfaces, magnesium (Mg), a naturally abundant element in the human body, shows great potential for application because of its essential role in osteogenesis and bone remodeling and its inherent antibacterial properties.26-29 Nano-sized magnesium hydroxide [nano-Mg(OH)₂] offers advantages over bulk magnesium, including enhanced surface area, improved ion release, and better interaction with cells and bacteria.29,30 However, the application of Mg-based coatings is hindered by their rapid degradation and short-lived biological activity.27 To address this limitation, gelatin, a biopolymer derived from collagen, has been used to slow Mg degradation and promote cell attachment and osteogenic differentiation.31
Despite the individual benefits of Mg and gelatin in enhancing osseointegration and providing antibacterial effects, limited research has examined their combined application as a coating for titanium dental implants. Therefore, this study aimed to evaluate the in vitro dual-function osteogenic and antibacterial performance of a nano-Mg(OH)₂-gelatin coating applied to Ti via electrospinning and to optimize the coating composition to achieve balanced osteogenic and antibacterial efficacy.
Methodology
Preparation of Titanium Substrates
Figure 1 showing the schematic procedure of the experimental methodology. Commercially pure Ti plates (grade 2, 1 cm × 1 cm × 1 mm) were used as substrates. All plates were mechanically polished up to 1500 grit. To enhance coating adhesion, surfaces were pretreated by plasma electrolytic oxidation (PEO) to create a microporous surface. The samples were mounted on an acrylic mold, connected to a fixture, and immersed in a cold Na₂HPO₄ electrolyte solution (pH 11–12). A direct current of 550 V and 400 mA was applied for 10 minutes. After treatment, the samples were ultrasonically cleaned in deionized water for 10 minutes and dried at room temperature. The resulting PEO-treated Ti surfaces showed a porous microstructure that is ideal for coating deposition.
Preparation of the Nano-Mg(OH)₂-gelatin Coating
Nano-Mg(OH)₂ particles (≤100 nm, US Nanomaterial Inc., USA) were dispersed in a 20% (w/v) aqueous gelatin solution prepared from type I gelatin from bovine and porcine bones (Fluka, USA) at concentrations of 0, 4, 6, and 8% (w/v) to form coating solutions. Gelatin was initially dissolved in 2.5 mL of distilled water at 60°C under 500 rpm stirring for 30 minutes. Subsequently, 2.5 mL of dimethylformamide/DMF (Sigma-Aldrich, USA) were added as a solvent to maintain the gelatin in a sol state at room temperature32 and stirred at 60°C for 1 hour. The designated amount of nano-Mg(OH)₂ was then incorporated and mixed at 900 rpm for 3 hours until a homogenous mixture was obtained. The coatings were applied to PEO-treated Ti substrates using electrospinning under the following optimized parameters: 12-14-kV voltage, 1x10-2-µl/min flow rate, 12-cm tip-to-collector distance, and 2-hour spinning time. The coated samples were then dehydrothermally crosslinked at 140oC under vacuum pressure for 3 days. The samples were labelled as follows based on nano-Mg(OH)₂ content: G0 (0%); G4 (4%); G6 (6%), and G8 (8%).
Surface Characterization
Morphology and Elemental Analysis: Surface morphology and cross-sectional thickness were examined using scanning electron microscopy (SEM, JEOL JSM IT-200). Energy-dispersive X-ray spectroscopy (EDX) was used for elemental mapping and confirmation of Mg incorporation.
Contact Angle: Surface wettability was assessed using the sessile drop method by depositing a 5-µL droplet of deionized water on each sample. The static contact angle was also recorded. Measurements were taken at three different points per sample using a Canon 30 D digital camera and an EF 100-mm macro lens. Then, they were quantitatively counted on ImageJ.33
Magnesium Ion Release and pH Measurement: To evaluate Mg ion release, each coated sample was immersed in 5 mL of phosphate-buffered saline (pH 7.4) at 37°C. Changes in pH were detected using a pH meter (Mettler Toledo, Swiss). The solution was renewed after each sampling time. Magnesium ion concentration was measured at 1, 2, 5, 24, 96, 168, and 240 hours using an atomic absorption spectrophotometer (Thermo Scientific, USA) at a 285.2-nm wavelength. Calibration was performed prior to measurement using commercially available Mg standard solutions according to the manufacturer’s instructions. The Mg ion concentration of each sample was calculated based on the generated calibration curve.
Cell Culture Studies
Cell Culture: MC3T3-E1 pre-osteoblast cells (ATCC, USA) were cultured in α-MEM (Gibco, USA) and supplemented with 10% fetal bovine serum/FBS (Sigma-Aldrich, USA) and 1% penicillin-streptomycin (Gibco, USA) at 37°C in a humidified atmosphere with 5% CO₂. The media were refreshed every two days. Cells were subcultured upon reaching 80-90% confluence using 0.25% trypsin–EDTA (Sigma-Aldrich, USA).
Cell Morphology: Before biological testing, all samples were sterilized using ultraviolet irradiation for 30 minutes. Cells were directly seeded on the coatings at a 1x104/cm2 density. Following a 24-hour culture period, the samples were carefully cleaned three times using phosphate-buffered saline, fixed for four hours at 4oC using 2.5% glutaraldehyde, dehydrated using a series of graded ethanol solutions, vacuum-coated in gold, and examined using SEM.
Cell Proliferation (CCK-8 Assay): Cells were seeded onto each sample (1×10⁴ cells/well) in a 24-well plate. On days 1 and 4, cell proliferation was assessed using the CCK-8 assay (Abbkine Scientific, USA). Absorbance was measured at 450 nm using a microplate reader.
Alkaline Phosphatase (ALP) Activity: To assess early osteogenic differentiation, ALP activity was measured on days 5, 7, and 10 using an ALP assay kit (eLabscience, China). Cells were cultured in medium extracts with osteogenic supplements, including ascorbic acid (50 μg/mL; Sigma-Aldrich, USA), β-glycerophosphate (10 mM; Sigma-Aldrich, USA) and dexamethasone (100 nM; Sigma-Aldrich, USA). On days 5, 7, and 10, cells were lysed with 0.1% Triton X-100 (Sigma-Aldrich, USA). P-nitrophenyl phosphate was used as the substrate and absorbance was measured at 405 nm. Enzyme activity was normalized to total protein content (Bradford assay; Sigma-Aldrich, USA).
Antibacterial Assays
Bacteria and Culture Conditions: The antimicrobial properties of the coated Ti were evaluated against S. mutans (ATCC 25175) and S. sanguinis (ATCC 10556). These strains were pre-cultured on brain-heart infusion agar (Sigma-Aldrich, USA) at 37°C for 24 hours. A single colony was transferred to the brain-heart infusion broth (Sigma-Aldrich, USA) and incubated under the same conditions to prepare the master culture. Sterile samples were placed in a 24-well plate and then immersed in 500 µl of 0.5 Mac Farland bacterial suspension. The culture medium was refreshed every 24 hours.
Colony-Forming Unit (CFU) Assay: After 24, 48, and 72 hours of incubation, the adherent bacteria were dislodged by sonication and vortexing. The suspensions were serially diluted in a sterile saline solution at a 10-5 dilution factor. Then, 100 µl of the suspensions were plated on the brain-heart infusion agar. After 48 hours of incubation, CFUs were counted to determine CFU/mL.
Statistical Analysis
Overall, three independent biological replicates (n=3) were used for each treatment group at each observation time. Data are shown as mean ± standard deviation. Statistical comparisons were conducted using one- or two-way ANOVA followed by Tukey’s post hoc test. A p-value < 0.05 was considered statistically significant. GraphPad Prism 9.0 was used for all analyses.
Results
Surface Morphology and Composition: In the SEM analysis, all coated samples exhibited a uniform nanofiber network (Figure 2a–d). The G0 group (gelatin only) showed smooth, continuous fibers. In contrast, the G4, G6, and G8 groups displayed nano-Mg(OH)₂ particles embedded in the fibers. The amount of embedded particles increased with increasing nano-Mg(OH)₂ concentration. Cross-sectional SEM images showed that the coating thickness ranged from 110–120 µm across all groups. EDX mapping confirmed the presence and the amount of Mg deposited onto the surface in the G4, G6, and G8 coatings (Figure 3a-d).
SEM image of coating surface G0 (A), G4 (B), G6 (C), and G8 (D) with magnification of 3000× (5-µm scale bar). All groups showed the spiderweb structure of nano-Mg(OH)2-gelatin coating with localized nanoparticle aggregates embedded in the fibrous matrix (yellow arrow).
Mg distribution maps obtained via EDX for G0 (A), G4 (B), G6 (C), and G8 (D). The Mg atomic percentage deposited on the gelatin coating surface totaled 0% (G0), 5.47±0.03% (G4), 10.74±0.03% (G6), and 11.60±0.04% (G8), respectively.
Wettability of Coated Surfaces: Contact angle measurements indicated that all coated surfaces were hydrophilic. The G0 group had a contact angle of 84.9° ± 3°, whereas G4 and G6 groups showed significantly lower angles of 74.6° ± 2.7° and 64.1° ± 2.9°, respectively (p<0.05). The G8 group had a slightly lower contact angle (56.3° ± 2.7°) than G6 group (p>0.05) (Figure 4a).
A) Contact angle of samples (o) with the sessile drop method, B) Mg ion release cumulation of each concentration—detected by an atomic absorption spectrophotometer at 1, 2, 5, 24, 96, 168, and 240 hours, C) Line graph showing pH changes over times of nano-Mg(OH)2-gelatin coating. Asterisks (*) represent significant differences (p<0.05) between concentrations.
Magnesium Ion Release and pH: Atomic absorption spectrophotometer analysis showed a burst release of Mg2+ ions during the first 24 hours (Figure 4b). The highest Mg ion accumulation was observed in the G4 group (21.5 ppm). This result did not match the EDX-mapping trend, which showed higher Mg deposition at higher nanoparticle concentrations. The pH of the immersion medium slightly increased with higher Mg content (Figure 4c), remaining within physiologically acceptable limits (7.4–8.2) for mostgroups and observation time points.
Cell Morphology: Figure 5a shows the cells adhering to the coating substrate following 24 hours of incubation. The cells exhibited extensive filopodia extending across the coating and interconnections with neighboring cells. The cells appeared clustered, forming subconfluent cellular networks (Figure 5b).
SEM images of MC3T3-E1 cells cultured on Ti-coated surface observed at 500 (A) and 1000× (B) magnification. Yellow arrows indicate adherent cells. Cell proliferation at day 1 and 4 (C) and ALP activity at day 5, 7, and 10 (D) of MC3T3-E1 cells. Asterisks (*) show significantly differing concentrations.
Cell Proliferation and Osteogenic Activity: Cell proliferation increased over time in all groups (Figure 5c). The G8 group showed the highest proliferation, followed by G6 and G4. All Mg-containing coatings showed significantly higher proliferation than G0 (p < 0.01). ALP activity peaked on day 7 in the G8 group (Figure 5d), followed by G6 and G4. However, the differences between G4, G6, and G8 groups are less pronounced, suggesting that a 6% concentration might be sufficient to support ALP activity.
Antibacterial Activity: CFU counts demonstrated antibacterial effects in all Mg-containing groups. The G8 coating showed the greatest CFU reduction in S. mutans at 24-72 hours (~80%) when compared with G0 (p<0.001), followed by G6, which reduced CFU counts by 64% (Figure 6a). Meanwhile, G6 coating showed the highest S. sanguinis CFU reduction at 24-72 hours when compared with G0, reaching 40%. Statistical analysis confirmed significant effects of Mg concentration on S. mutans colonies (p<0.001) despite no significant effect on S. sanguinis colonies (Figure 6b).
Antibacterial activity of various concentrations of nano-Mg(OH)2-gelatin coating against S. mutans and S. sanguinis. Asterisks (*) indicate significant difference between concentrations.
Discussion
Surface modification of dental implants is widely employed to enhance biological performance. This study utilized a dual-coating strategy, combining PEO and electrospinning to optimize surface characteristics and bioactivity. PEO using Na2HPO4-based electrolyte was chosen as surface treatment in this study because it forms a porous and rough oxide layer that enhances corrosion resistance and improves implant bioactivity.34,35,36 However, fine cracks may still develop on the titanium surface after PEO treatment. Therefore, applying polymer-based coating on top of the PEO surface may serve as potential strategy to seal these cracks and further improve surface performance.37
The porous morphology produced by the Na2HPO4-based PEO treatment may have improved the attachment of the electrospun layer by providing potential anchoring sites for fibers and increasing surface roughness, as in previous studies.38,39In this study, attachment between electrospun coating and PEO is postulated to occur primarily by mechanical interlocking since no chemical crosslinking process was used to bond the coating layer to the PEO surface. However, as we avoided directly evaluating the adhesion strength between PEO and electrospun coating, further mechanistic adhesion studies are required to comprehensively validate this proposed mechanism.
The subsequent electrospun nano-Mg(OH)2-gelatin coating formed a spiderweb-like nanofibrous network mimicking the extracellular matrix, creating a favorable microenvironment for cell adhesion and migration.40 Although quantitative degradation analysis was ignored in this study, macroscopic observation during phosphate-buffered saline immersion showed the degradation of the electrospun coating within approximately 10 days. Even though the electrospun coating layer was intended to function as a temporary bioactive layer during osseointegration, the physical crosslinking approach in this study has limited support to increase the long-term stability of coating. Ideally, the coating should remain stable until the healing process is complete.41 This indicates the need for stronger crosslinking strategies to improve durability and control ion release. Following electrospun coating degradation, the underlying PEO surface would be exposed. A previous study has indicated that PEO improve biocompatibility and mechanical compatibility with bone,38which may continue to support osteogenesis and osseointegration after electrospun coating degradation. Nevertheless, further studies evaluating long-term degradation behavior and post-degradation biological performance are still required.
The dual-coating strategy was selected instead of direct Mg incorporation into the PEO layer to maximize the benefit of the bioactive porous characteristic of the PEO with extracellular matrix-like structure and the controlled active agent release capability of the electrospinning technique. Moreno et al.42 (2023) used a similar dual coating strategy to regulate active agent release. Moreover, since the nanoparticles are highly prone to agglomeration, their direct incorporation into the PEO layer may block surface pores and alter surface topography, potentially diminishing favorable characteristics of the porous structure.38
EDX analysis indicated that surface Mg content increased along with Mg(OH)2 higher concentrations, resulting in a localized atomic Mg content of ~10% in G6 and G8 groups, which has been associated with enhanced osseointegration.43 However, the optimal Mg content for antibacterial performance remains unclear. Although higher Mg deposition was detected at increased concentrations, Mg ion release followed no proportional trend, with the highest cumulative release observed in the G4 group. This discrepancy is likely due to nanoparticle agglomeration and heterogeneous distribution within the electrospun matrix,44 which may have rapidly dissolved surface-exposed particles. Despite such variability, all Mg-containing coatings released significantly more Mg ions than the control, confirming its successful incorporation.
Integrating nano-Mg(OH)2 into gelatin-based coatings notably improves biological performance. These results correlate with previous studies that showed that Mg-based coatings release ions and establish a favorable microenvironment for bone regeneration.45-49 Despite differences in ion release across concentrations, the overall alkaline microenvironment remained within a biologically favorable range,50 enabling osteogenic activity without exceeding cytotoxic thresholds. This highlights the importance of optimizing nanoparticle distribution and matrix crosslinking to ensure consistent and sustained ion delivery.
The elevation in pH across Mg-containing groups, while expected, confirms the corrosion-mediated alkalinity of Mg. Notably, the continued rise in pH beyond the initial release of ions suggests a delayed dissolution of Mg(OH)2 particles.45,46 Such prolonged alkaline state, although milder than that required for direct bactericidal action (~pH 9), benefits processes conducive to osteoblast function,50 supporting the potential of the coating for long-term bone integration. Moreover, the statistical significance of time and concentration effects on pH further highlights the tunability of the system, which is an essential feature for personalized implant application.
Surface wettability, as reflected by contact angle measurements, showed a consistent trend with Mg addition. Increasing Mg concentration significantly enhanced surface hydrophilicity (p<0.05) between the 0% and other groups. This finding is consistent with previous studies showing that increasing Mg(OH)₂ content enhances surface hydrophilicity. This effect is attributed to the presence of hydroxyl (–OH) groups in Mg(OH)₂, which can form hydrogen bonds with water molecules.51
Although hydrophilic surfaces have been associated with enhanced protein adsorption and osteoblast activity,52,53 previous studies have reported that optimal cell adhesion occurs on surfaces with contact angle ranging from 40 to 70o.54,55 The novelty of our study lies in its ability to optimize hydrophilicity by a relatively simple nano-Mg(OH)2-gelatin coating system.
Based on the results above, G6 and G8 showed hydrophilicity within the optimal range for cell adhesion. Furthermore, the findings suggest a saturation effect in hydrophilic enhancement whereby increasing Mg concentrations fails to proportionately increase surface wettability. This plateau effect is an important consideration in material design as it enables the efficient use of Mg and minimize the risk of cytotoxic effects associated with excessive Mg release.
Cell-based assays further confirmed the biocompatibility and osteoconductive potential of the coatings. SEM observation showed strong cell-surface interactions with coating surface and the interconnected cell morphology (Figure 5b), implying healthy osteoblastic behavior.56 While previous work has shown the role of Mg in promoting osteoblast proliferation and differentiation,47,57,58 in this study, Mg ion release likely acted synergistically with the mildly alkaline environment and Mg-mediated activation of osteogenic signaling pathways to enhance cell-surface interactions. Additionally, electrospinning creates a biomimetic extracellular matrix-like structure that further boosts positive effects on cell attachment and signalling.40,59
ALP activity reached its peak on day 7 in all groups, consistent with previous studies showing that ALP expression is highest during the early stages of osteogenic differentiation before declining as matrix mineralization progresses.26 Statistical analysis revealed significant differences between the control and Mg-containing groups, indicating the positive effect of Mg on promoting osteogenic activity.
Notably, the peak in ALP activity was observed earlier than the typical 10–14-day window in the literature.60This accelerated response may be linked with the initial burst release of Mg ions, which may accelerate osteogenic differentiation. Such an effect may be mediated by the early activation of key signaling pathways such as MAPK/ERK, PI3K/Akt, and Wnt/β-catenin signaling cascades.48,61,62 Furthermore, the comparable ALP activity between G6 and G8 indicates that a 6% Mg coatings may suffice to stimulate optimal osteogenic differentiation without excessive Mg exposure. Although Mg is generally regarded as low-risk, residual nanoparticles yet to be fully metabolized or cleared from the body may lead to localized tissue irritation or foreign body responses.63,64 Therefore, precise control of ion release remains essential.
The antibacterial findings in this study further distinguish it from prior research. While the inherent antimicrobial properties of Mg have been documented,47,49,65 this investigation reveals that nano-Mg(OH)₂ coatings can achieve substantial bacterial inhibition against S. mutans and S. sanguinis without the need for additional antibacterial agents. Concentration-dependent inhibition of S. mutans was observed, with significant reductions in bacterial counts in the Mg-containing groups. Notably, the 6 and 8% coatings showed high levels of bacterial inhibition within 48 hours. In contrast, S. sanguinis showed less sensitivity, suggesting strain-dependent responses to Mg that warrant further investigation. However, this difference may be associated with variations in metabolic activity, acid tolerance, and surface adhesion behavior between species.66,67 Although pH reached no strongly bactericidal levels, even slight alkalinity may disrupt acidogenic species such as S. mutans, whereas S. sanguinis seems more tolerant under these conditions.
The antibacterial mechanism is likely multifactorial, involving not only Mg ion release only but alsomild alkalization, osmotic stress from Mg2+ release, reactive oxygen species generation, and direct nanoparticle-bacteria interactions.68-70 Local pH increase from electrochemical corrosion45,46,65 impairs bacterial adhesion and interferes with bacterial metabolism.71 Moreover, Mg(OH)₂ has been reported to generate reactive oxygen species that disrupt bacterial membranes, impair enzymes, and damage intracellular components.69
It is tempting to speculate that the intact Mg(OH)₂ nanoparticles directly contribute to antibacterial action as not all particles are expected to dissolve into ionic form. These nanoparticles can adhere to bacterial membranes, increasing permeability and facilitating ion penetration, which could eventually inhibit bacterial metabolic activity.70,72
Importantly, differences between G6 and G8 were statistically insignificant, indicating a potential saturation effect. This level of efficacy compares favorably with more complex multi-component systems in earlier studies,57,58 suggesting that nano-Mg(OH)₂ alone may suffice for clinical applications requiring osseointegration and infection control. Additionally, Mg ion concentration seems to play a crucial role in the effectiveness of this dual-functional approach.73
This research has shown that incorporating nano-Mg(OH)₂ into a gelatin electrospun fiber matrix on a PEO-treated titanium surface provides dual functionality by improving osteogenic activity and decreasing bacterial colonization. Among the tested formulations, 6% nano-Mg(OH)₂ was found to provide the most balanced performance, achieving great biocompatibility, favorable hydrophilicity, adequate osteogenic stimulation, and effective antibacterial activity with no excessive levels of Mg. However, careful control of Mg release kinetics and coating degradation is vital to minimize potential cytotoxicity and local inflammation.41,63,74 Our study provides preliminary evidence supporting the biocompatibility of the system, but long-term in vivo studies are necessary to assess chronic effects and clearance dynamics.
Despite the promising in vitro results of this study, several limitations must be acknowledged. This study was conducted in an in vitro model that is unable to replicate the complex in vivo physiological environment, including dynamic immune responses, variable fluid shear forces, and competitive multi-tissue integration. The burst-release profile and inconsistent correlation between Mg content and ion release suggest uneven nanoparticle dispersion and limited control over degradation. Osteogenic evaluation was limited to short-term cell growth and specific enzyme activity, without exploring deeper molecular changes or mineralization processes. Moreover, coating adhesion strength, coating stability during implant insertion, long-term degradation behavior, and in vivo performance were not assessed. These limitations indicate that further optimization and comprehensive biological and mechanical evaluations with a larger sample size are required before clinical translation. Future studies should also investigate coating retention and mechanical stability under simulated insertion conditions and characterize coating degradation behavior over time. Evaluations of interfacial bonding strategies between the electrospun coating and PEO surface to refine coating durability and reduce the risk of coating detachment during placement are also important.
This study lays a solid foundation for further development. Future research should focus on optimizing coating durability, refining Mg release profiles, and exploring co-culture models that simulate the competitive dynamics between host cells and pathogens. Moreover, mineralization assays should be included in future studies to further evaluate the overall osteogenic and differentiation potential of Mg(OH)2 coatings. Data from such models would provide deeper insights into materials performance under simultaneous regenerative and infectious challenges and better support its clinical translation.
Conclusion
The nano Mg(OH)₂-gelatin coating shows promising dual functionality for dental implant applications by enhancing osteogenic activity and inhibiting bacterial growth. Among the tested concentrations, 6% nano-Mg(OH)₂ provides the most balanced combination of biocompatibility and antimicrobial performance. To advance its clinical applicability, future research should aim to improve coating durability, regulate Mg ion release, and assess bacterial susceptibility in varied conditions. Long-term and in vivo studies are essential to evaluate biological performance, degradation behavior, and mechanical stability, supporting the translation of this coating system into practical dental implant solutions.
References
-
1 - Pengpid S, Peltzer K. The prevalence of edentulism and their related factors in Indonesia, 2014/15. BMC Oral Health. 2018;18(1):118. doi: 10.1186/s12903-018-0582-7
» https://doi.org/10.1186/s12903-018-0582-7 -
2 - Zohrabian VM, Sonick M, Hwang D, Abrahams JJ. Dental implants. Semin Ultrasound CT MR. 2015;36(5):415-26. doi: 10.1053/j.sult.2015.09.002
» https://doi.org/10.1053/j.sult.2015.09.002 -
3 - Hong DG, Oh JH. Recent advances in dental implants. Maxillofac Plast Reconstr Surg. 2017;39(1):33. doi: 10.1186/s40902-017-0132-2
» https://doi.org/10.1186/s40902-017-0132-2 -
4 - Elani HW, Starr JR, Da Silva JD, Gallucci GO. Trends in dental implant use in the U.S., 1999-2016, and projections to 2026. J Dent Res. 2018;97(13):1424-30. doi: 10.1177/0022034518792567
» https://doi.org/10.1177/0022034518792567 -
5 - Avinash G, Onkar S. Dental implants and prosthetics market by products, materials and forecasts, 2020-2030 [Internet]. Allied Market Research; 2022. Available from: https://www.alliedmarketresearch.com/dental-implants-and-prosthetics-market
» https://www.alliedmarketresearch.com/dental-implants-and-prosthetics-market -
6 - Brunette DM, Tengvall P, Textor M, Thomsen P, editors. Titanium in medicine: material science, surface science, engineering, biological responses and medical applications. Berlin: Springer; 2001. doi: 10.1007/978-3-642-56486-4
» https://doi.org/10.1007/978-3-642-56486-4 -
7 - Chouirfa H, Bouloussa H, Migonney V, Falentin-Daudré C. Review of titanium surface modification techniques and coatings for antibacterial applications. Acta Biomater. 2019;83:37-54. doi: 10.1016/j.actbio.2018.10.036
» https://doi.org/10.1016/j.actbio.2018.10.036 -
8 - Almehmadi AH. Effect of magnesium-based coatings on titanium or zirconia substrates on bone regeneration and implant osseointegration: a systematic review. Front Mater. 2021;8:754697. doi: 10.3389/fmats.2021.754697
» https://doi.org/10.3389/fmats.2021.754697 -
9 - Chen L, Yan X, Tan L, Zheng B, Muhammed FK, Yang K, et al. In vitro and in vivo characterization of novel calcium phosphate and magnesium (CaP-Mg) bilayer-coated titanium for implantation. Surf Coat Technol. 2019;374:784-96. doi: 10.1016/j.surfcoat.2019.06.023
» https://doi.org/10.1016/j.surfcoat.2019.06.023 -
10 - Meng F, Yin Z, Ren X, Geng Z, Su J. Construction of local drug delivery system on titanium-based implants to improve osseointegration. Pharmaceutics. 2022;14(5):1069. doi: 10.3390/pharmaceutics14051069
» https://doi.org/10.3390/pharmaceutics14051069 -
11 - Guo T, Gulati K, Arora H, Han P, Fournier B, Ivanovski S. Race to invade: understanding soft tissue integration at the transmucosal region of titanium dental implants. Dent Mater. 2021;37(5):816-31. doi: 10.1016/j.dental.2021.02.005
» https://doi.org/10.1016/j.dental.2021.02.005 -
12 - Binderman I, Halperin-Sternfeld M, Miselli A. The immunobiological and dense collagen fibrous connective tissue barriers: the gate to periodontal and peri-implant health and longevity. In: Periodontics and implants: contemporary scientific and clinical perspective. London: IntechOpen; 2025. doi: 10.5772/intechopen.1011461
» https://doi.org/10.5772/intechopen.1011461 -
13 - Wang Y, Zhang Y, Miron RJ. Health, maintenance, and recovery of soft tissues around implants. Clin Implant Dent Relat Res. 2016;18(3):618-34. doi: 10.1111/cid.12343
» https://doi.org/10.1111/cid.12343 -
14 - Tardelli JD, Bagnato VS, Dos Reis AC. Bacterial adhesion strength on titanium surfaces quantified by atomic force microscopy: a systematic review. Antibiotics (Basel). 2023;12(6):994. doi: 10.3390/antibiotics12060994
» https://doi.org/10.3390/antibiotics12060994 -
15 - Costa RC, Abdo VL, Mendes PH, Mota-Veloso I, Bertolini M, Mathew MT, et al. Microbial corrosion in titanium-based dental implants: how tiny bacteria can create a big problem? J Bio Tribo Corros. 2021;7(4):136. doi: 10.1007/s40735-021-00575-8
» https://doi.org/10.1007/s40735-021-00575-8 -
16 - Campos Kajimoto N, Paiva Buischi Y, Mohamadzadeh M, Loomer P. The oral microbiome of peri-implant health and disease: a narrative review. Dent J (Basel). 2024;12(10):299. doi: 10.3390/dj12100299
» https://doi.org/10.3390/dj12100299 -
17 - Salvi GE, Cosgarea R, Sculean A. Prevalence and mechanisms of peri-implant diseases. J Dent Res. 2017;96(1):31-7. doi: 10.1177/0022034516667484
» https://doi.org/10.1177/0022034516667484 -
18 - Berglundh T, Armitage G, Araujo MG, Avila-Ortiz G, Blanco J, Camargo PM, et al. Peri-implant diseases and conditions: consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions. J Clin Periodontol. 2018;45(Suppl 20)-91. doi: 10.1111/jcpe.12957
» https://doi.org/10.1111/jcpe.12957 -
19 - Souza JG, Bertolini MM, Costa RC, Nagay BE, Dongari-Bagtzoglou A, Barão VA. NanoTargeting implant-associated infections: titanium surface loaded with antimicrobial agents. iScience. 2021;24(2):102008. doi: 10.1016/j.isci.2020.102008
» https://doi.org/10.1016/j.isci.2020.102008 -
20 - Galarraga-Vinueza ME, Pagni S, Finkelman M, Schoenbaum T, Chambrone L. Prevalence, incidence, systemic, behavioral, and patient-related risk factors and indicators for peri-implant diseases: an AO/AAP systematic review and meta-analysis. J Periodontol. 2025;96(6):587-633. doi: 10.1002/JPER.24-0154
» https://doi.org/10.1002/JPER.24-0154 -
21 - Sridhar S, Wang F, Wilson TG, Palmer K, Valderrama P, Rodrigues DC. The role of bacterial biofilm and mechanical forces in modulating dental implant failures. J Mech Behav Biomed Mater. 2019;92:118-27. doi: 10.1016/j.jmbbm.2019.01.012
» https://doi.org/10.1016/j.jmbbm.2019.01.012 -
22 - Wada M, Mameno T, Otsuki M, Kani M, Tsujioka Y, Ikebe K. Prevalence and risk indicators for peri-implant diseases: a literature review. Jpn Dent Sci Rev. 2021;57:78-84. doi: 10.1016/j.jdsr.2021.05.002
» https://doi.org/10.1016/j.jdsr.2021.05.002 -
23 - Armellini D, Reynolds MA, Harro JM, Molly L. Biofilm formation on natural teeth and dental implants: what is the difference? In: Shirtliff M, Leid JG, editors. The role of biofilms in device-related infections. Berlin: Springer; 2009. p. 109-22. doi: 10.1007/978-3-540-68119-9_5
» https://doi.org/10.1007/978-3-540-68119-9_5 -
24 - Dong H, Liu H, Zhou N, Li Q, Yang G. Surface modified techniques and emerging functional coating of dental implants. Coatings. 2020;10(11):1012. doi: 10.3390/coatings10111012
» https://doi.org/10.3390/coatings10111012 -
25 - Lu X, Wu Z, Xu K, Wang X, Wang S, Qiu H, et al. Multifunctional coatings of titanium implants toward promoting osseointegration and preventing infection: recent developments. Front Bioeng Biotechnol. 2021;9:783816. doi: 10.3389/fbioe.2021.783816
» https://doi.org/10.3389/fbioe.2021.783816 - 26 - Cai X, Cai J, Ma K, Huang P, Gong L, Huang D, et al. Fabrication and characterization of Mg-doped chitosan-gelatin nanocompound coatings for titanium surface functionalization. J Biomater Sci Polym Ed. 2016;27(10):954-71. doi: 10.1080/09205063.2016.1170416
- 27 - Feng H, Wang G, Jin W, Zhang X, Huang Y, Gao A, et al. Systematic study of inherent antibacterial properties of magnesium-based biomaterials. ACS Appl Mater Interfaces. 2016;8(15):9662-73. doi: 10.1021/acsami.6b02241
-
28 - Li X, Gao P, Wan P, Pei Y, Shi L, Fan B, et al. Novel bio-functional magnesium coating on porous Ti6Al4V orthopaedic implants: in vitro and in vivo study. Sci Rep. 2017;7:40755. doi: 10.1038/srep40755
» https://doi.org/10.1038/srep40755 -
29 - Babuska V, Kasi PB, Chocholata P, Wiesnerova L, Dvorakova J, Vrzakova R, et al. Nanomaterials in bone regeneration. Appl Sci. 2022;12(13):6793. doi: 10.3390/app12136793
» https://doi.org/10.3390/app12136793 -
30 - Meng Y, Zhang D, Jia X, Xiao K, Lin X, Yang Y, et al. Antimicrobial activity of nano-magnesium hydroxide against oral bacteria and application in root canal sealer. Med Sci Monit. 2020;26. doi: 10.12659/MSM.922920
» https://doi.org/10.12659/MSM.922920 -
31 - Tiyyagura HR, Fuchs-Godec R, Gorgieva S, Arthanari S, Mohan MK, Kokol V. Biomimetic gelatine coating for less corrosive and surface bioactive Mg-9Al-1Zn alloys. J Mater Res. 2018;33(10):1449-62. doi: 10.1557/jmr.2018.65
» https://doi.org/10.1557/jmr.2018.65 -
32 - Aoki H, Miyoshi H, Yamagata Y. Electrospinning of gelatin nanofiber scaffolds with mild neutral cosolvents for use in tissue engineering. Polym J. 2015;47(3):267-77. doi: 10.1038/pj.2014.94
» https://doi.org/10.1038/pj.2014.94 -
33 - Amly DA, Hajardhini P, Jonarta AL, Yulianto HD, Susilowati H. Enhancement of pyocyanin production by the subinhibitory concentration of royal jelly in Pseudomonas aeruginosa F1000Res. 2021;10:14. doi: 10.12688/f1000research.27915.4
» https://doi.org/10.12688/f1000research.27915.4 -
34 - Nasiruddin U, Rama Krishna L, Parfenov EV, Rameshbabu N. Bioceramic (HA/BG) particles incorporated PCL-PEO hybrid coated ZM21 magnesium alloy for temporary orthopaedic implant application. Ceram Int. 2025;51(29 Pt A):60434-54. doi: 10.1016/j.ceramint.2025.10.243
» https://doi.org/10.1016/j.ceramint.2025.10.243 -
35 - Maj L, Muhaffel F, Jarzebska A, Trelka A, Balin K, Bieda M, et al. Unveiling the mechanisms of coating formation during micro-arc oxidation of titanium in Na2HPO4 electrolyte. Surf Coat Technol. 2024;476:130224. doi: 10.1016/j.surfcoat.2023.130224
» https://doi.org/10.1016/j.surfcoat.2023.130224 -
36 - Rokosz K, Hryniewicz T, Dudek L. Phosphate porous coatings enriched with selected elements via PEO treatment on titanium and its alloys: a review. Materials (Basel). 2020;13(11):2468. doi: 10.3390/ma13112468
» https://doi.org/10.3390/ma13112468 -
37 - Fattah-alhosseini A, Chaharmahali R, Kaseem M. Corrosion behavior amelioration of Ti-based alloys by the hybrid plasma electrolytic oxidation (PEO)/polymer coatings: a review. Hybrid Adv. 2024;5:100151. doi: 10.1016/j.hybadv.2024.100151
» https://doi.org/10.1016/j.hybadv.2024.100151 -
38 - Cardoso GC, Grandini RC, Rau JV. Comprehensive review of PEO coatings on titanium alloys for biomedical implants. J Mater Res Technol. 2024;31:311-28. doi: 10.1016/j.jmrt.2024.06.068
» https://doi.org/10.1016/j.jmrt.2024.06.068 -
39 - Garcia-Cabezón C, Rodríguez-Méndez ML, Amigó Borrás V, Bayón R, Salvo-Comino C, Garcia-Hernandez C, et al. Improvements in tribological and anticorrosion performance of porous Ti-6Al-4V via PEO coating. Friction. 2021;9(5):1303-18. doi: 10.1007/s40544-020-0480-2
» https://doi.org/10.1007/s40544-020-0480-2 - 40 - Agarwal S, Wendorff JH, Greiner A. Use of electrospinning technique for biomedical applications. Polymer. 2008;49(26):5603-21. doi: 10.1016/j.polymer.2008.09.014
-
41 - Keerthiga G, Prasad MJ, Vijayshankar D, Singh Raman RK. Polymeric coatings for magnesium alloys for biodegradable implant application: a review. Materials (Basel). 2023;16(13):4700. doi: 10.3390/ma16134700
» https://doi.org/10.3390/ma16134700 -
42 - Moreno L, Wang C, Lamaka SV, Zheludkevich ML, Rodríguez-Hernández J, Arrabal R, et al. Ciprofloxacin release and corrosion behaviour of a hybrid PEO/PCL coating on Mg3Zn0.4Ca alloy. J Funct Biomater. 2023;14(2):65. doi: 10.3390/jfb14020065
» https://doi.org/10.3390/jfb14020065 -
43 - Wang S, Zhao X, Hsu Y, He Y, Wang F, Yang F, et al. Surface modification of titanium implants with Mg-containing coatings to promote osseointegration. Acta Biomater. 2023;169:19-44. doi: 10.1016/j.actbio.2023.07.048
» https://doi.org/10.1016/j.actbio.2023.07.048 -
44 - Singh AK, Tsotsas E. Influence of polydispersity and breakage on stochastic simulations of spray fluidized bed agglomeration. Chem Eng Sci. 2022;247:117022. doi: 10.1016/j.ces.2021.117022
» https://doi.org/10.1016/j.ces.2021.117022 - 45 - Rahim MI, Eifler R, Rais B, Mueller PP. Alkalization is responsible for antibacterial effects of corroding magnesium. J Biomed Mater Res A. 2015;103(11):3526-32. doi: 10.1002/jbm.a.35503
-
46 - Song GL, Atrens A. Understanding magnesium corrosion: a framework for improved alloy performance. Adv Eng Mater. 2003;5(12):837-58. doi: 10.1002/adem.200310405
» https://doi.org/10.1002/adem.200310405 -
47 - Zhao Q, Yi L, Jiang L, Ma Y, Lin H, Dong J. Osteogenic activity and antibacterial ability on titanium surfaces modified with magnesium-doped titanium dioxide coating. Nanomedicine (Lond). 2019;14(9):1109-33. doi: 10.2217/nnm-2018-0413
» https://doi.org/10.2217/nnm-2018-0413 -
48 - Nie X, Zhang X, Lei B, Shi Y, Yang J. Regulation of magnesium matrix composite materials on bone immune microenvironment and osteogenic mechanism. Front Bioeng Biotechnol. 2022;10:842706. doi: 10.3389/fbioe.2022.842706
» https://doi.org/10.3389/fbioe.2022.842706 -
49 - Yu Y, Jin G, Xue Y, Wang D, Liu X, Sun J. Multifunctions of dual Zn/Mg ion co-implanted titanium on osteogenesis, angiogenesis and bacteria inhibition for dental implants. Acta Biomater. 2017;49:590-603. doi: 10.1016/j.actbio.2016.11.067
» https://doi.org/10.1016/j.actbio.2016.11.067 -
50 - Galow AM, Rebl A, Koczan D, Bonk SM, Baumann W, Gimsa J. Increased osteoblast viability at alkaline pH in vitro provides a new perspective on bone regeneration. Biochem Biophys Rep. 2017;10:17-25. doi: 10.1016/j.bbrep.2017.02.001
» https://doi.org/10.1016/j.bbrep.2017.02.001 -
51 - Kondo A, Kurosawa R, Ryu J, Matsuoka M, Takeuchi M. Investigation on the mechanisms of Mg(OH)2 dehydration and MgO hydration by near-infrared spectroscopy. J Phys Chem C. 2021;125(20):10937-47. doi: 10.1021/acs.jpcc.1c01470
» https://doi.org/10.1021/acs.jpcc.1c01470 - 52 - Erakovic S, Jankovic A, Veljovic D, Palcevskis E, Mitric M, Stevanovic T, et al. Corrosion stability and bioactivity in simulated body fluid of silver/hydroxyapatite and silver/hydroxyapatite/lignin coatings on titanium obtained by electrophoretic deposition. J Phys Chem B. 2013;117(6):1633-43. doi: 10.1021/jp305252a
- 53 - Dammar I, Riksavianti F, Jubhari EH. The role of hydrophilic implant surfaces to enhance the osseointegration process. Makassar Dent J. 2024;13(2):251-4.
-
54 - Arima Y, Iwata H. Effect of wettability and surface functional groups on protein adsorption and cell adhesion using well-defined mixed self-assembled monolayers. Biomaterials. 2007;28(20):3074-82. doi: 10.1016/j.biomaterials.2007.03.013
» https://doi.org/10.1016/j.biomaterials.2007.03.013 -
55 - Al-Azzam N, Alazzam A. Micropatterning of cells via adjusting surface wettability using plasma treatment and graphene oxide deposition. PLoS One. 2022;17(6). doi: 10.1371/journal.pone.0269914
» https://doi.org/10.1371/journal.pone.0269914 -
56 - Jin J, Jaspers RT, Wu G, Korfage JA, Klein-Nulend J, Bakker AD. Shear stress modulates osteoblast cell and nucleus morphology and volume. Int J Mol Sci. 2020;21(21):8361. doi: 10.3390/ijms21218361
» https://doi.org/10.3390/ijms21218361 -
57 - Fan X, Du J, Li Y, Duan K, Liu G. Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility. J Orthop Surg Res. 2023;18(1):901. doi: 10.1186/s13018-023-04390-4
» https://doi.org/10.1186/s13018-023-04390-4 -
58 - Liu Y, Wu J, Zhang H, Wu Y, Tang C. Covalent immobilization of the phytic acid-magnesium layer on titanium improves the osteogenic and antibacterial properties. Colloids Surf B Biointerfaces. 2021;203:111768. doi: 10.1016/j.colsurfb.2021.111768
» https://doi.org/10.1016/j.colsurfb.2021.111768 - 59 - Rahmati M, Silva EA, Reseland JE, Heyward CA, Haugen HJ. Biological responses to physicochemical properties of biomaterial surface. Chem Soc Rev. 2020;49(15):5178-5224. doi: 10.1039/D0CS00103A
- 60 - Beck GR Jr, Sullivan EC, Moran E, Zerler B. Relationship between alkaline phosphatase levels, osteopontin expression, and mineralization in differentiating MC3T3-E1 osteoblasts. J Cell Biochem. 1998;68(2):269–80. doi: 10.1002/(SICI)1097-4644(19980201)68:2<269::AID-JCB13>3.0.CO;2-A
-
61 - Wang J, Ma XY, Feng YF, Ma ZS, Ma TC, Zhang Y, et al. Magnesium ions promote the biological behaviour of rat calvarial osteoblasts by activating the PI3K/Akt signalling pathway. Biol Trace Elem Res. 2017;179(2):284-93. doi: 10.1007/s12011-017-0948-8
» https://doi.org/10.1007/s12011-017-0948-8 -
62 - Liu J, Liu J, Attarilar S, Wang C, Tamaddon M, Yang C, et al. Nano-modified titanium implant materials: a way toward improved antibacterial properties. Front Bioeng Biotechnol. 2020;8:576969. doi: 10.3389/fbioe.2020.576969
» https://doi.org/10.3389/fbioe.2020.576969 -
63 - Echeverry-Rendón M, Stancic B, Muizer K, Duque V, Calderon DJ, Echeverria F, et al. Cytotoxicity assessment of surface-modified magnesium hydroxide nanoparticles. ACS Omega. 2022;7(21):17528-37. doi: 10.1021/acsomega.1c06515
» https://doi.org/10.1021/acsomega.1c06515 -
64 - Hassan N, Krieg T, Kopp A, Bach AD, Kröger N. Challenges and pitfalls of research designs involving magnesium-based biomaterials: an overview. Int J Mol Sci. 2024;25(11):6242. doi: 10.3390/ijms25116242
» https://doi.org/10.3390/ijms25116242 -
65 - Tan X, Wang Z, Yang X, Yu P, Sun M, Zhao Y, et al. Enhancing cell adhesive and antibacterial activities of glass-fibre-reinforced polyetherketoneketone through Mg and Ag PIII. Regen Biomater. 2023;10. doi: 10.1093/rb/rbad066
» https://doi.org/10.1093/rb/rbad066 -
66 - Lew HP, Quah SY, Lui JN, Bergenholtz G, Yu VS, Tan KS. Isolation of alkaline-tolerant bacteria from primary infected root canals. J Endod. 2015;41(4):451-6. doi: 10.1016/j.joen.2014.12.003
» https://doi.org/10.1016/j.joen.2014.12.003 -
67 - Díaz-Garrido N, Lozano CP, Kreth J, Giacaman RA. Competition and caries on enamel of a dual-species biofilm model with Streptococcus mutans and Streptococcus sanguinis. Appl Environ Microbiol. 2020;86(21). doi: 10.1128/AEM.01262-20
» https://doi.org/10.1128/AEM.01262-20 - 68 - Rodríguez-Sánchez J, Pacha-Olivenza MA, González-Martín ML. Bactericidal effect of magnesium ions over planktonic and sessile Staphylococcus epidermidis and Escherichia coli Mater Chem Phys. 2019;221:342-8. doi: 10.1016/j.matchemphys.2018.09.050
-
69 - Bhattacharya P, Dey A, Neogi S. An insight into the mechanism of antibacterial activity by magnesium oxide nanoparticles. J Mater Chem B. 2021;9(26):5329-39. doi: 10.1039/D1TB00875G
» https://doi.org/10.1039/D1TB00875G -
70 - Xia D, Shi X, Chen K, Hao A, Iseri Y. Understanding the mechanisms behind the antibacterial activity of magnesium hydroxide nanoparticles against sulfate-reducing bacteria in sediments. Sci Rep. 2024;14(1):21831. doi: 10.1038/s41598-024-72516-7
» https://doi.org/10.1038/s41598-024-72516-7 - 71 - Qin H, Zhao Y, Cheng M, Wang Q, Wang Q, Wang J, et al. Anti-biofilm properties of magnesium metal via alkaline pH. RSC Adv. 2015;5(28):21434-44. doi: 10.1039/C5RA00027K
-
72 - Suresh S, Thambidurai S, Arumugam J, Kandasamy M, Pugazhenthiran N, Balaji D, et al. Antibacterial activity and photocatalytic oxidative performance of zinc oxide nanorods biosynthesized using Aerva lanata leaf extract. Inorg Chem Commun. 2022;139:109398. doi: 10.1016/j.inoche.2022.109398
» https://doi.org/10.1016/j.inoche.2022.109398 -
73 - Widyasrini DA, Annisa M, Sunarintyas S, Samaranayake L, Siswomihardjo W. Magnesium infusion on dental implants and its impact on osseointegration and biofilm development: a review. Eur J Dent. 2025;19(4):869-81. doi: 10.1055/s-0045-1806958
» https://doi.org/10.1055/s-0045-1806958 - 74 - Wang Q, Jin S, Lin X, Zhang Y, Ren L, Yang K. Cytotoxic effects of biodegradation of pure Mg and MAO-Mg on tumor cells of MG63 and KB. J Mater Sci Technol. 2014;30(5):487-92. doi: 10.1016/j.jmst.2014.03.004