ABSTRACT
Objective:
To evaluate various kinematic movements on postoperative pain using a Reciproc system.
Material and Methods:
Fifty-six molar teeth were divided into four groups according to kinematics as follows: continuous rotation, 360° CCW – 30° CW, 270° CCW – 30° CW, and 150° CCW – 30° CW. Preoperative and postoperative pain levels using visual analogue scale (VAS), percussion pain, and analgesic intake were recorded for each subject. Postoperative pain levels at 1, 3, 5, and 7 d were evaluated. Data were analyzed statistically using the Kruskal-Walis, Mann-Whitney-U, one-way analysis of variance, and chi-square tests (p=0.05).
Results:
Continuous rotation resulted in more pain at Day 1 when compared with the reciprocating groups (360° CCW – 30° CW and 270° CCW – 30° C) (p<0.05).
Conclusions:
Continuous rotation resulted in more postoperative pain at Day 1 than in reciprocating groups, and thereafter no significant pain was found among the groups.
Keywords:
Apically extruded debris; Reciproc; Motion; Endodontic treatment; Postoperative pain