Acessibilidade / Reportar erro

Flow injection analysis with amperometric detection for morpholine determination in corrosion inhibitors

In this study, an electrochemical method is proposed using flow injection analysis and amperometric detection with screen-printed carbon electrodes for morpholine determination to monitor the quality of morpholine-based commercial inhibitors and the residual concentration of inhibitors that control internal corrosion in oil industry pipelines. The amperometric method resulted in a strong linear correlation coefficient (r = 0.9941) with a linear response over a concentration range of 20-120 mg L-1, a limit of detection of 10 mg L-1 and a limit of quantification of 30 mg L-1. In addition, the method has been shown to be precise, linear and homoscedastic. The recovery for the amperometric method was 100 ± 6%, and the recovery for the real condensate sample was 99 ± 2%. Thus, the proposed method is promising for analysing morpholine-based commercial inhibitors in oil industry pipelines with simple and low-cost methodologies compared with ion chromatography techniques.

morpholine; corrosion inhibitors; amperometry; screen-printed electrodes; flow injection analysis


Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br