Acessibilidade / Reportar erro

Utilization of the through-and-through technique for central vein angioplasty using stent-graft

The central vein stenosis is one of the most common conditions in patients with chronic kidney failure in a hemodialysis program. In these cases, angioplasty using stent-grafts has obtained good results. The stent-graft delivery system is generally of large diameter what can hinder its navigability in very severe stenosis or tortuosities. The through-and-through technique is commonly used for endovascular treatment of aortic aneurysms, making possible to achieve a good mechanism of stretch and easy navigation of the endograft delivery system. We report a case of a central venous stenosis in wich a stent-graft was inserted using the through-and-through technique in order to cross the lesion.

arteriovenous shunt, surgical; angioplasty; dialysis