Vestibular evoked myogenic potential (Vemp): evaluation of responses in normal subjects

BACKGROUND: the Vestibular Evoked Myogenic Potential (Vemp) is formed by myogenic neurophysiologic responses activated by high-intensity sound stimulation. The response is registered through surface electromyography of the cervical muscles during muscle contraction. The acoustic stimuli activate the saccular macula, the vestibular inferior nerve and the pathways related to the vestibule-spinal descendant nerves. AIM: to describe Vemp parameters in a normal population. METHODS: thirty adults, 13 men and 17 women with no otoneurological complaints were selected. The stimuli were 200 tone burst, with a frequency of 1Hz and intensity of 118 dB Na, band-pass filter ranging from 10Hz to 1500Hz. The first potential biphasic P13-N23 wave was analyzed. RESULTS: no significant difference was observed between the sides of stimulation in terms of latency and amplitude. However, a statistically significant difference was found for amplitude between genders. CONCLUSION: Vemp demonstrated to be a reliable instrument in the clinical assessment of the vestibular function.

Vestibular Function Tests; Evaluation; Standards