Acessibilidade / Reportar erro
Radiologia Brasileira, Volume: 41, Número: 5, Publicado: 2008
  • Os 60 anos do CBR Editoriais

    Cerri, Giovanni Guido
  • Controvérsias da técnica de detecção do linfonodo sentinela com manipulação cirúrgica prévia do tecido mamário Editoriais

    Buchpiguel, Carlos Alberto
  • Qual o seu diagnóstico? Qual O Seu Diagnóstico?

    Daher, Renato Tavares; Daher, Sérgio; Daher, Murilo Tavares; Daher, Ricardo Tavares; Montandon Júnior, Marcelo Eustáquio; Montandon, Cristiano
  • Linfonodo sentinela após mamoplastia de aumento pela via transaxilar: estudo prospectivo controlado por meio de linfocintilografia em 43 pacientes Artigos Originais

    Sado, Heitor Naoki; Graf, Ruth Maria; Timi, Jorge Rufino Ribas; Urban, Cícero Andrade; Yamada, Airton Seiji; Woellner, Luiz Carlos; Ferreira, Eduardo de Castro; Matias, Jorge Eduardo Fouto

    Resumo em Português:

    OBJETIVO: Verificar se a mamoplastia de aumento pela via transaxilar apresenta potencial de prejudicar a identificação futura do linfonodo sentinela. MATERIAIS E MÉTODOS: Estudo prospectivo controlado em que foram selecionadas 22 pacientes divididas em grupo pós-mamoplastia e grupo controle, totalizando 43 mamas (22 no grupo pós-mamoplastia e 21 no grupo controle) avaliadas por meio de linfocintilografia imediatamente após injeções periareolares de fitato-99mTc. Os testes estatísticos consideraram como diferenças significativas valores de p < 0,05. RESULTADOS: Todas as mamas do grupo pós-mamoplastia apresentaram drenagem linfática para a cadeia axilar, sem diferença com o grupo controle (p = 0,488). A média de linfonodos captantes foi de 1,27 ± 0,46 no grupo pós-mamoplastia e 1,33 ± 0,58 no grupo controle (p = 0,895). A média de tempo para visualização do primeiro linfonodo foi de 3,14 ± 4,42 minutos no grupo pós-mamoplastia e 5,48 ± 5,06 minutos no grupo controle, novamente sem diferença significativa (p = 0,136). CONCLUSÃO: A mamoplastia de aumento pela via transaxilar não acarretou prejuízo na identificação futura do linfonodo sentinela.

    Resumo em Inglês:

    OBJECTIVE: To evaluate the potential influence of transaxillary augmentation mammoplasty on future detection of sentinel lymph node. MATERIALS AND METHODS: Prospective controlled study where 22 patients were selected and divided into two groups (post-mammoplasty and control) corresponding to 43 breasts (22 in the post-mammoplasty group and 21 in the control group) evaluated by lymphoscintigraphy immediately after periareolar 99mTc-phytate injections. In the statistical analysis, p values < 0.05 were considered as significant. RESULTS: All the breasts in the post-mammoplasty group presented lymphatic drainage to the axillary chain, with no difference as compared with the control group (p = 0.488). The average number of hot lymph nodes was 1.27 ± 0.46 in the post-mammoplasty group, and 1.33 ± 0.58 in the control group (p = 0.895). The mean time required to visualize the first lymph node was 3.14 ± 4.42 minutes in the post-mammoplasty group, and 5.48 ± 5.06 minutes in the control group (p = 0.136). CONCLUSION: Transaxillary augmentation mammoplasty did not affect the future detection of sentinel lymph node.
  • O valor da fase sem contraste na tomografia computadorizada do abdome Artigos Originais

    Leite, Ana Paula Klautau; Mattos, Leandro Accardo de; Pinto, Gustavo Alfredo Duarte Henriques; Scaciota, Andrea Puchnick; Franco, Rita Maria Aparecida Monteiro Moura; Andreoni, Cássio; Lederman, Henrique Manoel; D'Ippolito, Giuseppe

    Resumo em Português:

    OBJETIVO: Determinar o valor agregado da fase sem meio de contraste da tomografia computadorizada do abdome em pacientes sem diagnóstico determinado ou em estadiamento tumoral. MATERIAIS E MÉTODOS: Estudo prospectivo e transversal em 100 pacientes consecutivos submetidos a tomografia computadorizada abdominal sem e com meio de contraste intravenoso. Dois examinadores avaliaram todos os exames, procurando estabelecer, através da fase com meio de contraste intravenoso (primeira análise) e posteriormente através da fase sem contraste (segunda análise), o diagnóstico principal e os secundários em função da indicação clínica do exame. Mediu-se a freqüência de mudança diagnóstica decorrente da análise combinada das fases pré- e pós-contraste intravenoso. Casos que tiveram mudança diagnóstica foram avaliados por especialistas clínicos para determinar se implicaria mudanças de conduta. RESULTADOS: Diagnósticos principal e secundário foram modificados em 1 e 18 casos, respectivamente (p = 1,000; p = 0,143). Os diagnósticos modificados foram: esteatose, definição de nódulo em adrenal, nefrolitíase, classificação de cistos renais e calcificação hepática. Nos casos em que a fase sem contraste modificou o diagnóstico, os especialistas mudaram sua conduta em 14/19 (73%) dos pacientes (p = 0,038). CONCLUSÃO: A fase sem contraste não modificou significativamente o diagnóstico principal ou secundário. Porém, as mudanças nos diagnósticos secundários influenciaram na conduta adotada pelos especialistas.

    Resumo em Inglês:

    OBJECTIVE: To determine the role of the unenhanced phase of abdominal computed tomography in patients without a definite diagnosis or undergoing tumor staging. MATERIALS AND METHODS: A prospective and transversal study was developed with 100 consecutive patients submitted to unenhanced and contrast-enhanced abdominal computed tomography. Two observers evaluated all the computed tomography images in the contrast-enhanced phase (first analysis) and, later, in the unenhanced phase (second analysis) in an attempt to establish the primary and secondary diagnoses as a function of the clinical indication for the study. The frequency of changes in the diagnoses resulting from a combined analysis of the images in the pre- and post-contrast phases was evaluated. Cases with changes in the diagnosis were reviewed by clinical specialists for determining possible changes in the therapeutic approach. RESULTS: Primary and secondary diagnoses were changed in respectively 1 and 18 cases (p = 1.000; p = 0.143) as follows: steatosis, adrenal nodules, nephrolithiasis, renal cysts and hepatic calcification. In the cases where the unenhanced phase changed the diagnosis, the specialists changed the therapeutic approach in 14 of the 19 patients (73%) (p = 0.038). CONCLUSION: No significant change was observed in the primary or secondary diagnosis as a result of the findings in the unenhanced phase. However, changes in secondary diagnoses affected the therapeutic approach adopted by the specialists.
  • Aspectos tomográficos do tumor estromal gastrintestinal de origem gástrica: estudo de 14 casos Artigos Originais

    Pelandré, Gustavo Lemos; Djahjah, Maria Célia; Nobre, Luiz Felipe; Gasparetto, Emerson Leandro; Marchiori, Edson; Pereira, Bruno Vilhena; Valadão, Marcus; Linhares, Eduardo

    Resumo em Português:

    OBJETIVO: Descrever os achados tomográficos do tumor estromal gastrintestinal de origem gástrica. MATERIAIS E MÉTODOS: No período de janeiro de 1999 a dezembro de 2006, foram selecionados 14 pacientes com diagnóstico histopatológico e imuno-histoquímico de tumor estromal gastrintestinal gástrico que apresentavam tomografia computadorizada realizada anteriormente ao tratamento. As variáveis tomográficas analisadas foram: topografia da lesão, dimensões, homogeneidade, contornos, limites, morfologia, padrão e intensidade do realce pelo meio de contraste venoso, padrão de crescimento, invasão de órgãos adjacentes, presença de ulceração, fístula, calcificações, infiltração da gordura mesentérica, linfonodomegalias e metástases a distância. RESULTADOS: Os tumores foram localizados no corpo (57,1%) ou fundo gástrico (42,9%), com dimensões variando entre 6,0 e 23,0 cm (média de 11,5 cm). O crescimento foi predominantemente extraluminal (57,1%) ou intra/extraluminal (35,7%). O realce pelo contraste venoso foi discreto em 50% dos casos, moderado em 50% e heterogêneo em 64,3%. Foram ainda observadas hipodensidade central em 64,3% dos casos, invasão de órgãos adjacentes em 42,9% e metástases hepáticas em 7,2%. CONCLUSÃO: No presente estudo, a maioria dos tumores localizava-se no corpo gástrico, com tamanho médio de 11,5 cm, apresentando área hipodensa central, realce heterogêneo pelo meio de contraste e crescimento predominantemente extraluminal.

    Resumo em Inglês:

    OBJECTIVE: The purpose of this study was to describe the tomographic findings of gastric gastrointestinal stromal tumor. MATERIALS AND METHODS: Fourteen patients with histopathologically and immunohistochemically confirmed gastric gastrointestinal stromal tumors, who had already been submitted to computed tomography scans before the treatment, were evaluated in the period between January 1999 and December 2006. The following tomographic variables were analyzed: lesion topography, size/dimensions, homogeneity, contour, margins, morphology, pattern and intravenous contrast-enhancement intensity, growth pattern, invasion of adjacent organs, presence of ulceration, fistula, calcifications, mesenteric fat infiltration, lymphadenomegaly and presence of distant metastasis. RESULTS: Tumors were found in the body (57.1%) or in the gastric fundus (42.9%), with sizes ranging between 6.0 cm and 23.0 cm (mean, 11.5 cm). Predominantly extraluminal growth was observed in 57.1% of cases and intra/extraluminal in 35.7%. Subtle contrast-enhancement was observed in 50%, moderate in 50%, and heterogeneous in 64.3% of cases. Additionally, central hypodensity was observed in 64.3%, invasion of adjacent organs in 42.9%, and hepatic metastasis in 7.2% of cases. CONCLUSION: In the present study, the majority of tumors were found in the gastric body, with an average size of 11.5 cm, presenting with central hypodensity, heterogeneous contrast-enhancement and predominantly extraluminal growth.
  • Mensuração do volume de fluxo portal em pacientes esquistossomóticos: avaliação da reprodutibilidade do ultra-som Doppler Artigos Originais

    Leão, Alberto Ribeiro de Souza; Santos, José Eduardo Mourão; Moulin, Danilo Sales; Shigueoka, David Carlos; Colleoni, Ramiro; D'Ippolito, Giuseppe

    Resumo em Português:

    OBJETIVO: Avaliar a reprodutibilidade do ultra-som Doppler na quantificação do volume de fluxo portal em pacientes esquistossomóticos. MATERIAIS E MÉTODOS: Estudo prospectivo, transversal, observacional e autopareado, avaliando 21 pacientes portadores de esquistossomose hepatoesplênica, submetidos a mensuração do fluxo portal pelo ultra-som Doppler por três observadores, de forma independente, sendo calculada a concordância entre estes, dois a dois, pelo coeficiente de correlação intraclasse, teste t-pareado e grau de linearidade de Pearson. RESULTADOS: A concordância interobservador foi excelente. O coeficiente de correlação intraclasse variou entre 80,6% e 93,0% (IC a 95% [65,3% ; 95,8%]), com coeficiente de correlação de Pearson variando entre 81,6% e 92,7% e sem diferença estatisticamente significante entre os observadores quanto à média do fluxo portal mensurado pelo ultra-som Doppler (p = 0,954 / 0,758 / 0,749). CONCLUSÃO: O ultra-som Doppler é um método confiável para quantificar o fluxo portal em pacientes portadores de hipertensão porta de origem esquistossomótica, apresentando boa concordância interobservador.

    Resumo em Inglês:

    OBJECTIVE: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. MATERIALS AND METHODOS: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. RESULTS: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). CONCLUSION: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement.
  • Um novo método de avaliação do "tempo esofágico" com ultra-sonografia por abordagem externa Artigos Originais

    Sakate, Makoto; Teixeira, Altamir Santos; Yamashita, Seizo; Medeiros, Thais Ricardo; Silva, Pedro Gabriel da; Henry, Maria Aparecida Coelho de Arruda

    Resumo em Português:

    OBJETIVO: Utilizar a ultra-sonografia como método de avaliação do "tempo esofágico" e sua capacidade de discriminação entre as substâncias não-sólidas ingeridas (água e iogurte). MATERIAIS E MÉTODOS: Foram estudados 22 adultos jovens, sem queixa gástrica e esofágica, de ambos os sexos. Foi utilizado transdutor de ultra-som de 3,5 MHz, convexo, em modo B, colocado na região epigástrica. O intervalo de tempo esofágico foi determinado utilizando-se um cronômetro que foi acionado no momento da movimentação da glote (início da deglutição) e interrompido ao se visualizar a passagem do conteúdo deglutido no esôfago intra-abdominal. RESULTADOS: O tempo médio de trânsito para a água foi de 6,64 ± 1,83 segundos e para o iogurte foi de 8,59 ± 2,70 segundos. A análise estatística comparativa pelo teste t pareado mostrou que as médias apresentaram diferenças significativas entre as substâncias. CONCLUSÃO: O novo método experimental de avaliar o "tempo esofágico" com ultra-som é capaz de propiciar diferenças significativas do tempo necessário para um determinado alimento (líquido ou pastoso) percorrer o esôfago, esclarecendo as suspeitas clínicas e possibilitando a indicação mais precisa de exames clínicos mais complexos.

    Resumo em Inglês:

    OBJECTIVE: To utilize ultrasonography for evaluating the esophageal transit time as well as the esophagus capability of differentiating among non-solid substances ingested (water and yoghurt). MATERIALS AND METHODS: Twenty-two young adults of both sexes with no gastric or esophageal complaint were evaluated, with a B-mode 3.5 MHz, convex transducer placed over the epigastric area. The esophageal transit time was determined by means of a chronometer activated when the deglutition was initiated (glottic movement), and stopped upon visualization of the bolus through the intra-abdominal esophagus. RESULTS: The mean esophageal transit time for water was 6.64 ± 1.83 sec, and 8.59 ± 2.70 sec for yoghurt. The comparative statistical analysis by a t-paired test has demonstrated statistically significant differences between the mean esophageal transit times for the two substances. CONCLUSION: This new experimental method for evaluating the esophageal transit time by ultrasonography demonstrates significant differences in the time required for a determined liquid or pasty food passing through the esophagus, elucidating clinical suspicions and allowing a more precise indication for further, more complex clinical studies.
  • Avaliação crítica dos benefícios e limitações da ressonância magnética como método complementar no diagnóstico das malformações fetais Artigos Originais

    Ximenes, Renato Luis da Silveira; Szejnfeld, Jacob; Ximenes, Andréa Regina da Silveira; Zanderigo, Valdir

    Resumo em Português:

    OBJETIVO: Avaliar, por meio da ressonância magnética, uma série de fetos com diagnóstico ultra-sonográfico de malformação, a fim de estabelecer os benefícios e limites diagnósticos proporcionados pela técnica de ressonância magnética fetal, em comparação com a ultra-sonografia. MATERIAIS E MÉTODOS: Foram estudadas 40 mulheres entre 15-35 semanas de gestação com diagnóstico de anomalia fetal durante o exame de ultra-sonografia. As pacientes foram encaminhadas para o estudo complementar com ressonância magnética. As indicações para o estudo da ressonância magnética fetal foram: anomalias do sistema nervoso central, do tórax, do abdome, renais, esqueléticas e tumores. A avaliação pós-natal incluiu a revisão das imagens de ultra-sonografia e ressonância magnética, o acompanhamento do nascimento, exames laboratoriais, radiológicos e necropsia. RESULTADOS: Os resultados mostraram que os estudos complementares com ressonância magnética fetal trouxeram informações adicionais em 60% dos casos estudados. Os benefícios da ressonância magnética fetal foram: ampliação da avaliação global, aumento do campo de avaliação, maior resolução tecidual pelo uso de seqüências, e avaliação em pacientes obesas e com oligoidrâmnio. Os limites da ressonância magnética fetal foram: evitar exame no primeiro trimestre, avaliação do fluxo sanguíneo, movimentação fetal, claustrofobia materna, estudo do coração fetal e esqueleto. CONCLUSÃO: A ressonância magnética fetal pode ser utilizada como método complementar para a avaliação das malformações fetais.

    Resumo em Inglês:

    OBJECTIVE: The present study was aimed at evaluating by means of magnetic resonance imaging a series of fetuses with sonographic diagnosis of malformation, establishing the diagnostic benefits and limitations of fetal magnetic resonance imaging as compared with ultrasonography. MATERIALS AND METHODS: Forty women between 15-35 gestational weeks and previously diagnosed with fetal abnormality by ultrasonography were referred to undergo complementary fetal magnetic resonance imaging, particularly for evaluating abnormalities in the fetal central nervous system, thorax, abdomen, renal system, skeletal system, and tumors. The whole evaluation process included a review of the fetal ultrasonography and magnetic resonance images, postnatal follow-up, laboratory tests, imaging studies and necropsy. RESULTS: The present study has demonstrated that complementary magnetic resonance imaging did provide further information in 60% of cases, with the following benefits: improved information on the fetus as a whole, with a large field of view, higher anatomic resolution provided by fast sequences, superior soft tissue contrast resolution, besides the fact that the visualization of the fetus is not significantly affected by maternal obesity or oligohydramnios. Limitations of the method include contraindication in the first gestational trimester and in cases of maternal claustrophobia, sensitivity to fetal motion, low sensitivity for detecting cardiovascular and skeletal malformations. CONCLUSION: Fetal magnetic resonance imaging plays a significant role as a complementary method for the diagnosis of fetal anomalies.
  • Avaliação da exposição dos médicos à radiação em procedimentos hemodinâmicos intervencionistas Artigos Originais

    Silva, Leonardo Peres da; Maurício, Claudia Lúcia de Pinho; Canevaro, Lucía Viviana; Oliveira, Paulo Sérgio

    Resumo em Português:

    OBJETIVO: Este trabalho avalia a distribuição de dose recebida por médicos envolvidos em procedimentos hemodinâmicos de angioplastia coronária e coronariografia. A influência de alguns fatores, como o modo de fluoroscopia pulsado ou contínuo e o local de acesso à veia e/ou artéria, foi investigada. MATERIAIS E MÉTODOS: Para esta avaliação foram feitas medições utilizando dosímetros termoluminescentes de LiF:Mg,Ti, posicionados em sete diferentes pontos do corpo dos profissionais: mãos, joelho, pescoço, testa e tórax, por dentro e por fora do avental de chumbo. A dose foi avaliada, por exame, nos médicos que executaram os procedimentos (30 de angioplastia e 60 de coronariografia). Os dosímetros termoluminescentes foram calibrados na grandeza operacional equivalente de dose pessoal, Hp(d), nas profundidades de 0,07, 3 e 10 mm. RESULTADOS: Os resultados mostram a importância do uso do protetor de tireóide e avental de chumbo para a redução da dose recebida pelos médicos. As doses dos profissionais que executaram procedimentos por via braquial usando modo contínuo de fluoroscopia foram mais altas do que os que executaram por via femoral e modo pulsado de fluoroscopia. CONCLUSÃO: Este estudo mostra a necessidade de medidas adicionais de proteção e a implementação de mecanismos de treinamento em proteção radiológica para os médicos que trabalham com cardiologia intervencionista.

    Resumo em Inglês:

    OBJECTIVE: The present study evaluates the dose distribution received by physicians involved in hemodynamic procedures of coronary angiography and coronariography. The influence of some factors such as pulsed or continuous fluoroscopy mode and vein and/or artery access site was investigated. MATERIALS AND METHODS: Measurements have been performed with LiF:Mg,Ti thermoluminescent dosimeters placed on seven different sites of the practitioners' bodies: hands, left knee, neck, forehead and chest, under and over the lead apron. Radiation doses for each procedure were evaluated in physicians who had performed 60 coronariography and 30 angioplasty procedures. The thermoluminescent dosimeters were calibrated in the operational quantity personal dose equivalent, Hp(d), at depths of 0.07, 3 and 10 mm. RESULTS: The results of the present study demonstrate the significant role played by thyroid protectors and lead aprons for reducing radiation doses received by practitioners. Occupational doses in continuous mode fluoroscopy through brachial access were higher than with pulsed mode fluoroscopy through femoral access. CONCLUSION: The present study has demonstrated the necessity of implementing additional protective measures as well as a mechanism of training in radiation protection for physicians involved in interventional cardiological procedures.
  • Riscos dos exames radiográficos em recém-nascidos internados em um hospital público de Belo Horizonte, MG Artigos Originais

    Lacerda, Marco Aurélio de Sousa; Silva, Teógenes Augusto da; Khoury, Helen Jamil; Vieira, José Nelson Mendes; Matushita, João Paulo Kawaoka

    Resumo em Português:

    OBJETIVO: Os objetivos deste trabalho são: a) avaliar os procedimentos radiográficos e estimar o valor do kerma no ar na superfície de entrada nos recém-nascidos prematuros submetidos a exames de tórax e abdome, realizados no setor de neonatologia de um hospital público de Belo Horizonte; b) estimar as doses nos órgãos e os respectivos riscos de ocorrência de câncer nesses órgãos em decorrência das exposições à radiação. MATERIAIS E MÉTODOS: Foram analisados os prontuários dos pacientes internados no setor de neonatologia desse hospital durante o período de maio a setembro de 2004, anotando-se os dados antropométricos, data de internação/alta, exames de raios X realizados. O kerma no ar na superfície de entrada foi determinado a partir do rendimento do tubo de raios X e dos parâmetros de irradiação utilizados nos exames. As doses nos órgãos foram estimadas com o software PCXMC e o risco, durante o restante da expectativa de vida, com o software IREP. RESULTADOS: O valor médio do kerma no ar na superfície de entrada por exame foi abaixo do nível de referência da publicação da Comunidade Européia. Para o paciente mais severamente irradiado, os órgãos mais suscetíveis à ocorrência de câncer foram fígado, mama e estômago, com valores máximos de excess relative risk, respectivamente, de 3,4%, 2,3% e 1,7%. CONCLUSÃO: Foi constatada a necessidade de otimização dos procedimentos radiográficos com vista à diminuição do risco para os recém-nascidos, que apesar de ser considerado baixo (comparativamente ao benefício), deve ser sempre diminuído para valores tão baixos quanto razoavelmente exeqüíveis.

    Resumo em Inglês:

    OBJECTIVE: The present study was aimed at: a) evaluating radiographic procedures and estimating entrance surface air kerma in preterm neonates submitted to chest and abdominal radiography at the unit of neonatology in a public hospital of Belo Horizonte, MG, Brazil; b) estimating the dose to organs and respective risks for cancer as a result from radiation exposure. MATERIALS AND METHODS: Records of patients admitted to the unit of neonatology of this hospital in the period between May and September 2004 were reviewed. Anthropometric data, admission/discharge dates and radiographic studies performed were recorded for each of the patients. The calculation of the entrance surface air kerma was based on the x-ray tube output and irradiation parameters adopted for examinations. Dose to organs was calculated with the aid of the software PCXMC, and the lifetime risk for cancer, with the software IREP. RESULTS: Mean entrance surface air kerma per examination was below the diagnostic reference levels recommended by the European Community. In the most severely irradiated patients, liver, breast and stomach were the organs at highest risk for cancer, with maximum excess relative risk of respectively 3.4%, 2.3%, and 1.7%. CONCLUSION: The present study demonstrated the need for optimization of radiographic procedures in order to reduce the risks for neonates that, in spite of being considered to be low as compared with the benefits, should be reduced to values as low as reasonably achievable.
  • Implementação e avaliação de um sistema de gerenciamento de imagens médicas com suporte à recuperação baseada em conteúdo Artigos Originais

    Caritá, Edilson Carlos; Seraphim, Enzo; Honda, Marcelo Ossamu; Azevedo-Marques, Paulo Mazzoncini de

    Resumo em Português:

    OBJETIVO: Neste artigo são descritas a implementação e avaliação de um sistema de gerenciamento de imagens médicas com suporte à recuperação baseada em conteúdo (PACS-CBIR), integrando módulos voltados para a aquisição, armazenamento e distribuição de imagens, e a recuperação de informação textual por palavras-chave e de imagens por similaridade. MATERIAIS E MÉTODOS: O sistema foi implementado com tecnologias para Internet, utilizando-se programas livres, plataforma Linux e linguagem de programação C++, PHP e Java. Há um módulo de gerenciamento de imagens compatível com o padrão DICOM e outros dois módulos de busca, um baseado em informações textuais e outro na similaridade de atributos de textura de imagens. RESULTADOS: Os resultados obtidos indicaram que as imagens são gerenciadas e armazenadas corretamente e que o tempo de retorno das imagens, sempre menor do que 15 segundos, foi considerado bom pelos usuários. As avaliações da recuperação por similaridade demonstraram que o extrator escolhido possibilitou a separação das imagens por região anatômica. CONCLUSÃO: Com os resultados obtidos pode-se concluir que é viável a implementação de um PACS-CBIR. O sistema apresentou-se compatível com as funcionalidades do DICOM e integrável ao sistema de informação local. A funcionalidade de recuperação de imagens similares pode ser melhorada com a inclusão de outros descritores.

    Resumo em Inglês:

    OBJECTIVE: The present paper describes the implementation and evaluation of a medical images management system with content-based retrieval support (PACS-CBIR) integrating modules focused on images acquisition, storage and distribution, and text retrieval by keyword and images retrieval by similarity. MATERIALS AND METHODS: Internet-compatible technologies were utilized for the system implementation with freeware, and C++, PHP and Java languages on a Linux platform. There is a DICOM-compatible image management module and two query modules, one of them based on text and the other on similarity of image texture attributes. RESULTS: Results demonstrate an appropriate images management and storage, and that the images retrieval time, always < 15 sec, was found to be good by users. The evaluation of retrieval by similarity has demonstrated that the selected images extractor allowed the sorting of images according to anatomical areas. CONCLUSION: Based on these results, one can conclude that the PACS-CBIR implementation is feasible. The system has demonstrated to be DICOM-compatible, and that it can be integrated with the local information system. The similar images retrieval functionality can be enhanced by the introduction of further descriptors.
  • Ressonância magnética e tomografia computadorizada da articulação temporomandibular: além da disfunção Artigo De Revisão

    Garcia, Marcelo de Mattos; Machado, Karina Freitas Soares; Mascarenhas, Marcelo Henrique

    Resumo em Português:

    Várias doenças devem ser consideradas no diagnóstico diferencial dos distúrbios que comprometem as articulações temporomandibulares. A disfunção interna é a principal entidade responsável pelos quadros dolorosos desta articulação. Entretanto, os achados clínicos podem ser bastante inespecíficos e diversas outras condições se manifestam com sinais e sintomas semelhantes e, não raramente, indistinguíveis. Neste trabalho demonstramos, por meio de imagens de tomografia computadorizada e ressonância magnética, várias doenças não-disfuncionais, enfatizando a importância dos métodos de imagem no diagnóstico de doenças inflamatórias, neoplásicas e traumáticas desta região. O papel do radiologista é fundamental no diagnóstico diferencial, uma vez que o quadro clínico é, com freqüência, inespecífico.

    Resumo em Inglês:

    Several diseases should be considered in the differential diagnosis of disorders affecting the temporomandibular joints. Internal derangement is the main condition responsible for pain related to this joint. Clinical signs may, though, be quite non-specific, and many other conditions present with similar and not infrequently indistinguishable signs and symptoms. In the present study, the authors describe several non-dysfunctional conditions affecting the temporomandibular joints through computed tomography and magnetic resonance imaging, emphasizing the importance of these imaging methods in the diagnosis of inflammatory, neoplastic and traumatic diseases of this region. Considering that clinical presentations are frequently non-specific, radiologists play a critical role in the differential diagnosis.
  • Procedimentos percutâneos pélvicos guiados por imagem: revisão das principais vias de acesso Ensaio Iconográfico

    Garcia, Rodrigo Gobbo; Macedo Filho, Carlos Leite de; Maurano, Alexandre; Francisco Neto, Miguel José; Daniel, Mauro Miguel; Rosemberg, Laercio Alberto; Funari, Marcelo Buarque de Gusmão

    Resumo em Português:

    Os procedimentos percutâneos orientados por imagem têm ganhado espaço crescente na radiologia intervencionista, constituindo ferramenta eficaz para a abordagem diagnóstica e terapêutica de massas e coleções nos diversos segmentos corporais. No entanto, localizações pélvicas profundas ainda representam grande desafio para o radiologista, por causa da interposição de estruturas anatômicas. Para que o procedimento seja bem sucedido é fundamental o planejamento da via de acesso baseado no conhecimento detalhado da anatomia radiológica da pelve. As principais vias de acesso para a abordagem destas lesões são: transabdominais (anterior e lateral), extraperitoneal ântero-lateral, transvaginal, transretal e transglútea. O objetivo deste trabalho é fazer uma revisão da anatomia seccional pélvica normal, demonstrando as diversas vias de acesso para biópsias e drenagens guiadas pela ultra-sonografia e pela tomografia computadorizada, bem como discutir as principais vantagens e complicações potenciais de cada uma delas.

    Resumo em Inglês:

    Image-guided percutaneous procedures have increasingly been established as safe and effective interventional tools in the diagnosis and management of masses and collections in several body segments. However, lesions in deep pelvic sites still pose a challenge for radiologists because of overlying anatomic structures. The success of a percutaneous biopsy depends on a safe access route planning based on a deep understanding of cross sectional anatomy of the pelvis. Anterior and lateral transabdominal, anterolateral extraperitoneal, transvaginal, transrectal and transgluteal approaches are described. The present study was aimed at reviewing the normal pelvic cross-sectional anatomy, demonstrating the different access routes for ultrasonography and computed tomography guided pelvic biopsies and drainages as well as discussing the main advantages and complications associated with these approaches.
  • Leiomiomatose peritoneal disseminada: relato de caso Relato De Caso

    Gedda, Marco Antonio Marini; Piantavinha, Giuliano Arrivabeni; Coutinho, Túlio Rebello; Mendonça, Silvana Machado; Bello, Gustavo de Vasconcelos

    Resumo em Português:

    Neste trabalho relata-se o caso de uma paciente de 46 anos de idade com queixa de aumento de volume periumbilical e dor leve antes da menstruação. O quadro evoluiu com aumento gradativo da dor. Foram realizados ultra-som, tomografia computadorizada e ressonância magnética. Após laparotomia exploradora, foi retirado material para biópsia que confirmou o diagnóstico de leiomiomatose peritoneal disseminada.

    Resumo em Inglês:

    The present study reports the case of a 46-year-old female patient complaining of mild premenstrual pain and increase in the volume of the periumbilical region. The condition progressed with a gradual increase of the pain intensity. Ultrasonography, computed tomography and magnetic resonance imaging were performed. Biopsy of tissue collected during exploratory laparotomy confirmed the diagnosis of leiomyomatosis peritonealis disseminata.
  • Análise da concordância entre observadores no diagnóstico das doenças pulmonares intersticiais pela tomografia computadorizada de alta resolução Resumos De Teses

    Antunes, Viviane Baptista
  • Correlação laboratorial e radiográfica das manifestações maxilo-mandibulares em pacientes renais crônicos em hemodiálise Resumos De Teses

    Barrella, Vanessa Vieira
  • Comparação entre as técnicas de dacriocistografia por ressonância magnética e por raios X no diagnóstico da obstrução das vias lacrimais Resumos De Teses

    Abreu Junior, Luiz de
  • Contribuições da cintilografia de perfusão e função miocárdica com duplo isótopo na vigência de baixa dose de dobutamina: avaliação da integridade celular e reserva contrátil na identificação do miocárdio viável Resumos De Teses

    Moraes, Renata Freire de
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem Av. Paulista, 37 - 7º andar - conjunto 71, 01311-902 - São Paulo - SP, Tel.: +55 11 3372-4541, Fax: 3285-1690, Fax: +55 11 3285-1690 - São Paulo - SP - Brazil
E-mail: radiologiabrasileira@cbr.org.br