Logomarca do periódico: Radiologia Brasileira

Open-access Radiologia Brasileira

Publication of: Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
Area: Health Sciences ISSN online version: 1678-7099

Table of contents

Radiologia Brasileira, Volume: 49, Issue: 2, Published: 2016

Radiologia Brasileira, Volume: 49, Issue: 2, Published: 2016

Document list
EDITORIALS
Are 3D FSE MRI sequences of the knee at 1.5 T effective in the detection of meniscal and ligament tears? How useful are they? Fernandes, Artur da Rocha Corrêa
EDITORIALS
Hypersensitivity pneumonitis: the importance of the radiologist in the multidisciplinary approach to its diagnosis Nobre, Luiz Felipe Steidle, Leila John Marques
EDITORIALS
Percutaneous biopsy in radiological imaging of the breast Canella, Ellyete de Oliveira
EDITORIALS
PET/CT in the evaluation of pulmonary solitary nodule Barbosa, Felipe de Galiza
ORIGINAL ARTICLES
Diagnostic performance of 3D TSE MRI versus 2D TSE MRI of the knee at 1.5 T, with prompt arthroscopic correlation, in the detection of meniscal and cruciate ligament tears Chagas-Neto, Francisco Abaeté Nogueira-Barbosa, Marcello Henrique Lorenzato, Mário Müller Salim, Rodrigo Kfuri-Junior, Maurício Crema, Michel Daoud

Abstract in Portuguese:

Resumo Objetivo: Comparar o desempenho diagnóstico da técnica tridimensional turbo spin-eco (3D TSE) de ressonância magnética (RM) do joelho na detecção de rupturas meniscais e ligamentares em comparação com o protocolo bidimensional turbo spin-eco (2D TSE). Materiais e Métodos: A sequência 3D TSE foi adicionada ao protocolo de rotina 2D TSE em 38 pacientes que foram submetidos a cirurgia artroscópica do joelho em até três dias após a realização da RM. Usando os achados artroscópicos como referência padrão ouro, foram calculados o desempenho diagnóstico e a concordância entre os protocolos. Resultados: A técnica 3D TSE e o protocolo 2D TSE apresentaram, respectivamente, sensibilidade (93%/93%) e especificidade (80%/ 85%) semelhantes na detecção de rupturas do ligamento cruzado anterior, sensibilidade (85%/83%) e especificidade (68%/71%) semelhantes na detecção de rupturas do menisco medial, assim como sensibilidade (58%/54%) e especificidade (82%/92%) semelhantes na detecção de rupturas do menisco lateral. A concordância intraobservador entre os dois métodos foi de substancial a quase perfeita em todos os parâmetros avaliados para ambos os leitores. Conclusão: A técnica 3D- SE apresentou desempenho diagnóstico semelhante ao protocolo de rotina 2D TSE na detecção de rupturas meniscais e ligamentares em magneto de 1,5 T, com a vantagem de possibilitar uma redução significativa no tempo de aquisição.

Abstract in English:

Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.
ORIGINAL ARTICLES
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol Trad, Henrique Simão Boasquevisque, Gustavo Santos Giacometti, Tiago Rangon Trad, Catherine Yang Zoghbi Neto, Orlando Salomão Trad, Clovis Simão

Abstract in Portuguese:

Resumo Objetivo: Propusemos um protocolo com 50 mL de contraste, sem seleção de população e testamos o contraste vascular e a qualidade de imagem. Materiais e Métodos: Vinte e nove pacientes com idades entre 22 e 86 anos, com índice de massa corporal de 19,0 a 41,8 kg/m2, realizaram angiografia pulmonar em equipamento de 64 detectores. Foram injetados 50 mL de contraste iodado em acesso venoso periférico, na taxa de 4,5 mL/s2, com técnica de bolus tracking na veia cava superior. Dois radiologistas experientes avaliaram o realce vascular e a qualidade de imagem. Resultados: A densidade média no tronco pulmonar, ramos direito e esquerdo, artérias pulmonares inferiores direita e esquerda foram, respectivamente, 382, 379, 377, 346 e 364 unidades Hounsfield. Artérias subsegmentares foram avaliadas em todos os casos. Artefatos por restos de contraste na veia cava superior estavam presentes em todos os casos, sem prejudicar a avaliação das imagens. Conclusão: Angiotomografia pulmonar pode ser realizada com 50 mL de contraste iodado, sem necessidade de seleção dos pacientes e apesar de suas características físicas, com boa qualidade de imagem.

Abstract in English:

Abstract Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations.
ORIGINAL ARTICLES
Dosimetric evaluation of X-ray examinations of paranasal sinuses in pediatric patients Cantalupo, Beatriz de Lucena Villa-Chan Xavier, Aline Carvalho da Silva Silva, Clemanzy Mariano Leandro da Andrade, Marcos Ely Almeida Barros, Vinícius Saito Monteiro de Khoury, Helen Jamil

Abstract in Portuguese:

Resumo Objetivo: Estimar o kerma no ar na superfície de entrada (Ka,e) e o kerma no ar na região de órgãos radiossensíveis em radiografias pediátricas dos seios paranasais. Materiais e Métodos: Foram coletados os dados dos pacientes e parâmetros de irradiação em exames de seios paranasais de crianças com 0 a 15 anos, em dois hospitais infantis na cidade do Recife, PE. O Ka,e foi estimado utilizando os rendimentos dos tubos de raios X e os parâmetros selecionados. Os valores de kerma no ar nas regiões dos olhos e tireoide foram estimados utilizando dosímetros termoluminescentes. Resultados: Os valores de Ka,e variaram de 0,065 a 1,446 mGy para radiografias cavum, 0,104 a 7,298 mGy para Caldwell e 0,113 a 7,824 mGy para Waters. Os valores de kerma no ar na região dos olhos variaram de 0,001 a 0,968 mGy para cavum e 0,011 a 0,422 mGy para Caldwell e Waters. Na região tireóidea, os valores de kerma no ar variaram de 0,005 a 0,932 mGy para cavum e 0,002 a 0,972 mGy para Caldwell e Waters. Conclusão: Os parâmetros de irradiação utilizados pelas instituições foram mais elevados do que os recomendados em protocolos britânicos. Ações de otimização são recomendadas de modo a contribuir para a redução da radiação nos pacientes e, portanto, os riscos.

Abstract in English:

Abstract Objective: To estimate the entrance surface air kerma (Ka,e) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. Materials and Methods: Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0 to 15 years of age at two children's hospitals in the city of Recife, PE, Brazil. We estimated the Ka,e using the X-ray tube outputs and selected parameters. To estimate the air kerma values in the regions of the eyes and thyroid, we used thermoluminescent dosimeters. Results: The Ka,e values ranged from 0.065 to 1.446 mGy in cavum radiographs, from 0.104 to 7.298 mGy in Caldwell views, and from 0.113 to 7.824 mGy in Waters views. Air kerma values in the region of the eyes ranged from 0.001 to 0.968 mGy in cavum radiographs and from 0.011 to 0.422 mGy in Caldwell and Waters views . In the thyroid region, air kerma values ranged from 0.005 to 0.932 mGy in cavum radiographs and from 0.002 to 0.972 mGy in Caldwell and Waters views. Conclusion: The radiation levels used at the institutions under study were higher than those recommended in international protocols. We recommend that interventions be initiated in order to reduce patient exposure to radiation and therefore the risks associated with radiological examination of the paranasal sinuses.
ORIGINAL ARTICLES
Low-level laser therapy for the prevention of low salivary flow rate after radiotherapy and chemotherapy in patients with head and neck cancer Gonnelli, Fernanda Aurora Stabile Palma, Luiz Felipe Giordani, Adelmo José Deboni, Aline Lima Silva Dias, Rodrigo Souza Segreto, Roberto Araújo Segreto, Helena Regina Comodo

Abstract in Portuguese:

Resumo Objetivo: Avaliar o impacto do laser de baixa potência na prevenção de hipofluxo salivar em pacientes portadores de câncer de cabeça e pescoço após radioterapia e quimioterapia. Materiais e Métodos: Treze pacientes receberam laserterapia e dez receberam cuidados clínicos. Utilizou-se um InGaAlP laser diodo para aplicação intraoral (comprimento de onda de 660 nm, 40 mW de potência e dose média de 10 J/cm2) e extraoral (comprimento de onda de 780 nm, 15 mW de potência e dose média de 3,7 J/cm2), três vezes por semana, em dias alternados. Sialometrias estimulada e não estimulada foram realizadas antes da primeira sessão de radioterapia e quimioterapia (N0) e 30 dias após o final do tratamento (N30). Resultados: Em N30, os pacientes submetidos à laserterapia apresentaram médias estatisticamente maiores de fluxo salivar estimulado (p = 0,0131) e não estimulado (p = 0,0143), em comparação com os pacientes que receberam apenas cuidados clínicos. Conclusão: A laserterapia de baixa potência realizada concomitantemente a radioterapia e quimioterapia foi capaz de mitigar a hipofunção das glândulas salivares em pacientes portadores de câncer de cabeça e pescoço após o tratamento oncológico.

Abstract in English:

Abstract Objective: To determine whether low-level laser therapy can prevent salivary hypofunction after radiotherapy and chemotherapy in head and neck cancer patients. Materials and Methods: We evaluated 23 head and neck cancer patients, of whom 13 received laser therapy and 10 received clinical care only. An InGaAlP laser was used intra-orally (at 660 nm and 40 mW) at a mean dose of 10.0 J/cm2 and extra-orally (at 780 nm and 15 mW) at a mean dose of 3.7 J/cm2, three times per week, on alternate days. Stimulated and unstimulated sialometry tests were performed before the first radiotherapy and chemotherapy sessions (N0) and at 30 days after the end of treatment (N30). Results: At N30, the mean salivary flow rates were significantly higher among the laser therapy patients than among the patients who received clinical care only, in the stimulated and unstimulated sialometry tests (p = 0.0131 and p = 0.0143, respectively). Conclusion: Low-level laser therapy, administered concomitantly with radiotherapy and chemotherapy, appears to mitigate treatment-induced salivary hypofunction in patients with head and neck cancer.
ORIGINAL ARTICLES
Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir Campos, Tarcísio Passos Ribeiro de Lima, Carla Flavia de Cuperschmid, Ethel Mizrahy

Abstract in Portuguese:

Resumo Objetivo: Análise dosimétrica comparativa entre técnicas de implantes temporários de reforço por meio de balões de 99mTc e de 192Ir de alta taxa de dose (high dose rate - HDR) mediante simulação computacional. A hipótese é que ambos produzem dosimetria equivalente em condições pré-estabelecidas de atividade e exposição. Materiais e Métodos: Simulações de implantes com balão preenchido com 99mTc e balão HDR-192Ir foram elaboradas no Siscodes/ MCNP5, modelando em voxels um tórax feminino reproduzido de ressonância magnética de mama jovem. Distribuições espaciais de taxas de dose absorvidas foram geradas. Análises dosimétricas dos protocolos foram apresentadas especificando tempo acumulado e atividade requerida. Resultados: Implante temporário com balão-99mTc apresentou taxa de dose ponderada no leito do tumor, na adjacência do balão, de 0,428 cGyh-1.mCi-1, e a 8-10 mm distante, de 0,190 cGyh-1.mCi-1, enquanto o implante de balão com 192Ir apresentou 0,499 e 0,150 cGyh-1.mCi-1, respectivamente. A exposição de 24 horas para balão-99mTc foi necessária para produzir o reforço de 10,14 Gy com 1,0 Ci, ao passo que para balão HDR-192Ir foram necessários 24 minutos com segmentos de 10,0 Ci para gerar 5,14 Gy no mesmo ponto de referência, ou 10,28 Gy em duas frações de 24 minutos. Conclusão: Implante temporário com balão-99mTc é atrativo para a radioterapia adjuvante do câncer de mama, devido a disponibilidade, viabilidade econômica e equivalência radiodosimétrica ao balão HDR-192Ir, protocolo presente na prática clínica.

Abstract in English:

Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.
ORIGINAL ARTICLES
Analysis of translational errors in frame-based and frameless cranial radiosurgery using an anthropomorphic phantom Almeida, Taynná Vernalha Rocha Cordova Junior, Arno Lotar Piedade, Pedro Argolo Silva, Cintia Mara da Marins, Priscila Almeida, Cristiane Maria Brincas, Gabriela R. Baseggio Soboll, Danyel Scheidegger

Abstract in Portuguese:

Resumo Objetivo: Comparar os erros de posicionamento e erros residuais translacionais tridimensionais de uma radiocirurgia guiada por imagem, frame versus frameless, com uso de um objeto simulador antropomórfico. Materiais e Métodos: Para a calibração e qualidade do sistema de imagem foram utilizados objetos simuladores específicos. Para o teste hidden target foi utilizado o crânio do objeto simulador antropomórfico Alderson Radiation Therapy (ART)-210, dentro do qual foram inseridas quatro esferas metálicas de 5 mm de diâmetro como volumes alvos de tratamento. Imagens tomográficas foram realizadas com o ART-210 devidamente posicionado para ambos os métodos de imobilização. Resultados: Para o método frameless, a média foi 0,22 ± 0,04 mm para os erros setup e 0,14 ± 0,02 mm para os erros residuais, apresentando uma incerteza combinada de 0,28 mm e 0,16 mm, respectivamente. Para o método frame, a média foi 0,73 ± 0,14 mm para os erros setup e 0,31 ± 0,04 mm para os erros residuais, apresentando uma incerteza combinada de 1,15 mm e 0,63 mm, respectivamente. Conclusão: Com base nas médias, desvios-padrão e incertezas combinadas, os resultados mostraram não haver evidências de diferença significativa entre as técnicas em questão quando utilizado um objeto simulador antropomórfico craniano ART-210.

Abstract in English:

Abstract Objective: To evaluate three-dimensional translational setup errors and residual errors in image-guided radiosurgery, comparing frameless and frame-based techniques, using an anthropomorphic phantom. Materials and Methods: We initially used specific phantoms for the calibration and quality control of the image-guided system. For the hidden target test, we used an Alderson Radiation Therapy (ART)-210 anthropomorphic head phantom, into which we inserted four 5mm metal balls to simulate target treatment volumes. Computed tomography images were the taken with the head phantom properly positioned for frameless and frame-based radiosurgery. Results: For the frameless technique, the mean error magnitude was 0.22 ± 0.04 mm for setup errors and 0.14 ± 0.02 mm for residual errors, the combined uncertainty being 0.28 mm and 0.16 mm, respectively. For the frame-based technique, the mean error magnitude was 0.73 ± 0.14 mm for setup errors and 0.31 ± 0.04 mm for residual errors, the combined uncertainty being 1.15 mm and 0.63 mm, respectively. Conclusion: The mean values, standard deviations, and combined uncertainties showed no evidence of a significant differences between the two techniques when the head phantom ART-210 was used.
REVIEW ARTICLE
Solitary pulmonary nodule and 18F-FDG PET/CT. Part 2: accuracy, cost-effectiveness, and current recommendations Mosmann, Marcos Pretto Borba, Marcelle Alves Macedo, Francisco Pires Negromonte de Liguori, Adriano de Araujo Lima Villarim Neto, Arthur Lima, Kenio Costa de

Abstract in Portuguese:

Resumo O nódulo pulmonar solitário corresponde a um achado radiológico comum, cuja detecção ocorre frequentemente de forma incidental. A investigação desta entidade permanece complexa, uma vez que existem sobreposições entre as características dos processos benignos e malignos no seu diagnóstico diferencial. Atualmente, muitas estratégias estão disponíveis para a avaliação do nódulo pulmonar solitário, e o objetivo principal consiste em caracterizar da melhor forma possível as alterações benignas, não expondo os pacientes aos riscos de métodos invasivos, e detectar corretamente os casos de câncer de pulmão, não retardando potencial tratamento curativo. O foco deste estudo é revisar a avaliação do nódulo pulmonar solitário, discutindo o papel atual da tomografia por emissão de pósitrons com 18-fluordesoxiglicose, apresentar sua acurácia e custo-efetividade, bem como salientar as recomendações atuais do exame neste cenário.

Abstract in English:

Abstract A solitary pulmonary nodule is a common, often incidental, radiographic finding. The investigation and differential diagnosis of solitary pulmonary nodules remain complex, because there are overlaps between the characteristics of benign and malignant processes. There are currently many strategies for evaluating solitary pulmonary nodules. The main objective is to identify benign lesions, in order to avoid exposing patients to the risks of invasive methods, and to detect cases of lung cancer accurately, in order to avoid delaying potentially curative treatment. The focus of this study was to review the evaluation of solitary pulmonary nodules, to discuss the current role of 18F-fluorodeoxyglucose positron-emission tomography, addressing its accuracy and cost-effectiveness, and to detail the current recommendations for the examination in this scenario.
PICTORIAL ESSAYS
High-resolution computed tomography and histopathological findings in hypersensitivity pneumonitis: a pictorial essay Torres, Pedro Paulo Teixeira e Silva Moreira, Marise Amaral Rebouças Silva, Daniela Graner Schuwartz Tannus Gama, Roberta Rodrigues Monteiro da Sugita, Denis Masashi Moreira, Maria Auxiliadora do Carmo

Abstract in Portuguese:

Resumo A pneumonite por hipersensibilidade é uma doença intersticial difusa, granulomatosa e de natureza inalatória, com inúmeros antígenos orgânicos e inorgânicos implicados. Nosso objetivo é ilustrar o espectro de anormalidades na tomografia de alta resolução do tórax e achados histopatológicos. Foram avaliadas, retrospectivamente, tomografias de alta resolução do tórax de pacientes com diagnóstico de pneumonite por hipersensibilidade estabelecido em correlação clínico-radiológica e clínico-radiológico-patológica em pacientes em que a biópsia esteve disponível. A pneumonite por hipersensibilidade é dividida, do ponto de vista clínico e didático, em aguda, subaguda e crônica, e as manifestações tomográficas da tomografia de alta resolução do tórax correlacionam-se com o tempo da evolução da doença, e por vezes se superpõem. Micronódulos centrolobulares, vidro fosco e aprisionamento aéreo são características tomográficas na manifestação subaguda, em que, histopatologicamente, se observam infiltrado inflamatório linfocítico, bronquiolite, graus variáveis de pneumonia em organização e células gigantes. Na fase crônica, a tomografia demonstra sinais de fibrose com bronquiolectasias de tração e eventualmente faveolamento, com predomínio superior, sendo observados também sinais de fibrose no estudo histopatológico. A abordagem multidisciplinar é definitiva no diagnóstico, que é realizado correlacionando-se as características clínicas, nexo causal de exposição, achados tomográficos e aspectos histopatológicos.

Abstract in English:

Abstract Hypersensitivity pneumonitis is a diffuse interstitial and granulomatous lung disease caused by the inhalation of any one of a number of antigens. The objective of this study was to illustrate the spectrum of abnormalities in high-resolution computed tomography and histopathological findings related to hypersensitivity pneumonitis. We retrospectively evaluated patients who had been diagnosed with hypersensitivity pneumonitis (on the basis of clinical-radiological or clinical-radiological-pathological correlations) and had undergone lung biopsy. Hypersensitivity pneumonitis is clinically divided into acute, subacute, and chronic forms; high-resolution computed tomography findings correlate with the time of exposure; and the two occasionally overlap. In the subacute form, centrilobular micronodules, ground-glass opacities, and air trapping are characteristic high-resolution computed tomography findings, whereas histopathology shows lymphocytic inflammatory infiltrates, bronchiolitis, variable degrees of organizing pneumonia, and giant cells. In the chronic form, high-resolution computed tomography shows traction bronchiectasis, honeycombing, and lung fibrosis, the last also being seen in the biopsy sample. A definitive diagnosis of hypersensitivity pneumonitis can be made only through a multidisciplinary approach, by correlating clinical findings, exposure history, high-resolution computed tomography findings, and lung biopsy findings.
PICTORIAL ESSAYS
Ivory vertebra: imaging findings in different diagnoses Braun, Richard Andreas Milito, Carlos Felipe do Rego Barros Goldman, Suzan Menasce Fernandes, Eloy de Ávila

Abstract in Portuguese:

Resumo Pacientes com dor lombar são frequentemente atendidos em todos os níveis de saúde. O início da investigação diagnóstica, de modo geral, se dá com a realização das radiografias da coluna lombar. Além dos achados mais frequentes, os profissionais podem encontrar uma vértebra de densidade muito aumentada em comparação com as demais, chamada de vértebra em marfim. O objetivo deste trabalho é descrever as principais doenças que podem apresentar, entre suas características radiológicas, este tipo de vértebra, como linfoma de Hodgkin, doença de Paget, metástases de neoplasias prostáticas e de mama, além da osteomielite. Por ser, em alguns casos, a apresentação radiológica inicial dessas doenças, é de suma importância que o radiologista tenha conhecimento deste achado e oriente o profissional solicitante quanto às suas possíveis causas.

Abstract in English:

Abstract Low back pain is often managed at all levels of healthcare. In general, diagnostic investigation begins with radiography of the lumbar spine. In addition to the most common findings, radiologists can identify increased density of a vertebral body, referred to as ivory vertebra. The objective of this study was to describe the main diseases that can present with this radiologic sign, such as Hodgkin lymphoma, Paget's disease, metastatic prostate cancer, breast cancer, and osteomyelitis. It is extremely important that radiologists be aware of this finding in order to inform the requesting physician of the possible etiologies, given that it can be the initial radiologic presentation for these diseases.
CASE REPORT
Immunoglobulin G4-related disease: autoimmune pancreatitis and extrapancreatic manifestations Fernandes, Daniel Alvarenga Kido, Ricardo Yoshio Zanetti Barros, Ricardo Hoelz de Oliveira Martins, Daniel Lahan Penachim, Thiago José Caserta, Nelson Marcio Gomes

Abstract in Portuguese:

Resumo Apresentamos um caso de doença relacionada à IgG4, com acometimento pancreático e extrapancreático biliar e renal. Dada a relevância dos métodos de imagem para seu diagnóstico e diferenciação com o adenocarcinoma pancreático, ressaltamos os principais achados abdominais na tomografia computadorizada e ressonância magnética desta doença autoimune sistêmica recentemente reconhecida.

Abstract in English:

Abstract We present a case of immunoglobulin G4 (IgG4)-related disease with pancreatic and extrapancreatic involvement, including the biliary and renal systems. Given the importance of imaging methods for the diagnosis of IgG4-related disease and its differentiation from pancreatic adenocarcinoma, we emphasize important abdominal computed tomography and magnetic resonance imaging findings related to this recently recognized systemic autoimmune disease.
LETTERS TO THE EDITOR
Rapid MRI of the lungs in children with pulmonary infections Sodhi, Kushaljit Singh Bhatia, Anmol Khandelwal, Niranjan
LETTERS TO THE EDITOR
Incidental diagnosis of struma ovarii through radioiodine whole-body scanning: incremental role of SPECT/CT Vale, Rômulo Hermeto Bueno do Sado, Heitor Naoki Danilovic, Débora Lucia Seguro Duarte, Pulo Schiavom Sapienza, Marcelo Tatit
LETTERS TO THE EDITOR
Pancake kidney with cysts and a single ureter Silva, Renata Mendes da Morais Júnior, Moaci Ferreira de Mont'Alverne Filho, Francisco Edward
LETTERS TO THE EDITOR
Thrombocytopenia-absent radius syndrome: prenatal diagnosis of a rare syndrome Bertoni, Natália Canhetti Pereira, Daniela Cardoso Araujo Júnior, Edward Bussamra, Luiz Claudio de Silva Aldrighi, José Mendes
LETTERS TO THE EDITOR
Remote cerebellar hemorrhage and intracranial hypotension syndrome following pituitary surgery Abreu Junior, Luiz de Martucci, Henrique T. Mendonça, Paulo Tarso Reck de Marques, Gustavo Garcia Rodrigues, Célia
LETTERS TO THE EDITOR
Ultrasound guided injection of botulinum toxin into the salivary glands of children with neurological disorders Matsuoka, Marcia Wang Rocha, Sílvia Maria Sucena da Suzuki, Lisa Barnewitz, João Paulo Imamura, Rui Oliveira, Luiz Antonio Nunes de
location_on
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem Av. Paulista, 37 - 7º andar - conjunto 71, 01311-902 - São Paulo - SP, Tel.: +55 11 3372-4541, Fax: 3285-1690, Fax: +55 11 3285-1690 - São Paulo - SP - Brazil
E-mail: radiologiabrasileira@cbr.org.br
rss_feed Stay informed of issues for this journal through your RSS reader
Accessibility / Report Error