Ultrasonography for evaluation of hamstring tendon diameter: is it possible to predict the size of the graft? Study conducted at Universidade Federal de São Paulo, Escola Paulista de Medicina, Centro de Ortopedia e Traumatologia do Esporte (CETE), São Paulo, SP, Brazil.

ABSTRACT

Objective:

Perform the preoperative measurement of the hamstring tendons using ultrasound imaging, validating and correlating the measured value with that found during surgical reconstruction of the ligament.

Methods:

A cross-sectional study was carried out with 24 patients who underwent ultrasonographic measurement of the semitendinosus and gracilis muscle tendons and were subsequently submitted to surgical reconstruction of the ACL, with ipsilateral semitendinosus and gracilis tendon grafting.

Results:

The patients’ ages ranged from 16 to 43 years, with a mean of 24.8 years (SD = 8.4 years), 79.2% were men, and the distribution by side was 41.7% right knees and 58.3% left knees. A non-significant correlation coefficient was found between the area calculated by ultrasound (2 × semitendinosus area + 2 × gracilis area) and the intraoperative measurement (r = 0.16; p = 0.443). No evidence of a difference between intraoperative measurements <8 mm and ≥8 mm was found for the area calculated by the ultrasound (p = 0.746). The difference observed between the groups was −0.01 (95% CI: −0.09 to 0.07).

Conclusion:

Preoperative ultrasound imaging of the semitendinosus and gracilis tendons does not present a statistically significant correlation with the intraoperative measurement of the quadruple hamstring graft for ligament reconstruction.

Keywords:
Anterior cruciate ligament; Knee injuries; Ultrasonography

RESUMO

Objetivo:

Fazer a mensuração pré-operatória dos tendões flexores do joelho com o uso do exame de ultrassonografia, validar e correlacionar o valor medido com aquele encontrado durante a reconstrução cirúrgica do ligamento.

Métodos:

Estudo transversal com 24 pacientes submetidos a mensuração ultrassonográfica dos tendões dos músculos semitendíneo e grácil e posteriormente submetidos a reconstrução cirúrgica do LCA, com enxerto ipsilateral dos tendões semitendíneo e grácil do próprio paciente.

Resultados:

A idade dos pacientes variou entre 16 e 43 anos, com média de 24,8 (DP = 8,4), 79,2% eram homens e a distribuição quanto ao lado foi de 41,7% joelhos direitos e 58,3% joelhos esquerdos. Foi encontrado coeficiente de correlação não significante entre a área calculada a partir do ultrassom (2 × área do semitendíneo + 2 × área do grácil) e a medida obtida intraoperatoriamente (r = 0,16, p = 0,443). Não foi encontrada evidência de diferença entre medidas intraoperatórias < 8 mm e ≥ 8 mm quanto à área calculada a partir do ultrassom (p = 0,746). A diferença observada entre os grupos foi de -0,01 (IC 95%: -0,09 a 0,07).

Conclusão:

A mensuração pré-operatória por método de imagem ultrassonográfico dos tendões dos músculos semitendíneo e grácil não apresenta correlação estatisticamente significante com a mensuração intraoperatória do enxerto quádruplo de flexores para reconstrução ligamentar.

Palavras-chave:
Ligamento cruzado anterior; Traumatismos do joelho; Ultrassonografia

Introduction

Anterior cruciate ligament (ACL) reconstruction is one of the most performed surgeries worldwide, with more than 120,000 procedures per year in the United States.11 Kim S, Bosque J, Meehan JP, Jamali A, Marder R. Increase in outpatient knee arthroscopy in the United States: a comparison of National Surveys of Ambulatory Surgery, 1996 and 2006. J Bone Joint Surg Am. 2011;93(11):994-1000. In order to restore the ACL function on knee stability, graft reconstruction is currently considered the gold standard. This graft may be autologous or from a tissue bank (allograft).22 Bartlett RJ, Clatworthy MG, Nguyen TN. Graft selection in reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br. 2001;83(5):625-34.,33 West RV, Harner CD. Graft selection in anterior cruciate ligament reconstruction. J Am Acad Orthop Surg. 2005;13(3):197-207.

The choice of graft depends on the patient, the type of implant used, and the availability of a tissue bank.33 West RV, Harner CD. Graft selection in anterior cruciate ligament reconstruction. J Am Acad Orthop Surg. 2005;13(3):197-207.,44 Magnussen RA, Lawrence JT, West RL, Toth AP, Taylor DC, Garrett WE. Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft. Arthroscopy. 2012;28(4):526-31. The following grafts are most commonly used: tendons of the knee flexor muscles (hamstring), semitendinosus and gracilis, patellar tendon, and quadricipital tendon. In Brazil, knee flexor grafting is the option used by 82.3% of the knee specialists who participated in research at a national conference.55 Arliani GG, Astur Dda C, Kanas M, Kaleka CC, Cohen M. Anterior cruciate ligament injury: treatment and rehabilitation. Current perspectives and trends. Rev Bras Ortop. 2012;47(2):191-6. In addition to adequate technique, graft size is also extremely important for the success of the procedure.44 Magnussen RA, Lawrence JT, West RL, Toth AP, Taylor DC, Garrett WE. Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft. Arthroscopy. 2012;28(4):526-31.

When using quadricipital or patellar grafts, it is possible to determine graft size.44 Magnussen RA, Lawrence JT, West RL, Toth AP, Taylor DC, Garrett WE. Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft. Arthroscopy. 2012;28(4):526-31. However, when the graft option is the hamstrings (knee flexor tendons), the literature does not describe a well-recognized and accurate method for predicting graft size preoperatively. Previous studies have used different methods of preoperative measurement to adequately predict flexor graft size, such as anthropometric data55 Arliani GG, Astur Dda C, Kanas M, Kaleka CC, Cohen M. Anterior cruciate ligament injury: treatment and rehabilitation. Current perspectives and trends. Rev Bras Ortop. 2012;47(2):191-6.

6 Boisvert CB, Aubin ME, DeAngelis N. Relationship between anthropometric measurements and hamstring autograft diameter in anterior cruciate ligament reconstruction. Am J Orthop (Belle Mead NJ). 2011;40(6):293-5.

7 Ma CB, Keifa E, Dunn W, Fu FH, Harner CD. Can pre-operative measures predict quadruple hamstring graft diameter?. Knee. 2010;17(1):81-3.

8 Treme G, Diduch DR, Billante MJ, Miller MD, Hart JM. Hamstring graft size prediction: a prospective clinical evaluation. Am J Sports Med. 2008;36(11):2204-9.
-99 Tuman JM, Diduch DR, Rubino LJ, Baumfeld JA, Nguyen HS, Hart JM. Predictors for hamstring graft diameter in anterior cruciate ligament reconstruction. Am J Sports Med. 2007;35(11):1945-9. and imaging studies.1010 Bickel BA, Fowler TT, Mowbray JG, Adler B, Klingele K, Phillips G. Preoperative magnetic resonance imaging cross-sectional area for the measurement of hamstring autograft diameter for reconstruction of the adolescent anterior cruciate ligament. Arthroscopy. 2008;24(12):1336-41.

11 Han Y, Kurzencwyg D, Hart A, Powell T, Martineau PA. Measuring the anterior cruciate ligament's footprints by three-dimensional magnetic resonance imaging. Knee Surg Sports Traumatol Arthrosc. 2012;20(5):986-95.

12 Wernecke G, Harris IA, Houang MT, Seeto BG, Chen DB, MacDessi SJ. Using magnetic resonance imaging to predict adequate graft diameters for autologous hamstring double-bundle anterior cruciate ligament reconstruction. Arthroscopy. 2011;27(8):1055-9.

13 Leiter J, Elkurbo M, McRae S, Chiu J, Froese W, MacDonald P. Using pre-operative MRI to predict intraoperative hamstring graft size for anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2017;25(1):229-35.

14 Erquicia JI, Gelber PE, Doreste JL, Pelfort X, Abat F, Monllau JC. How to improve the prediction of quadrupled semitendinosus and gracilis autograft sizes with magnetic resonance imaging and ultrasonography. Am J Sports Med. 2013;41(8):1857-63.
-1515 Yasumoto M, Deie M, Sunagawa T, Adachi N, Kobayashi K, Ochi M. Predictive value of preoperative 3-dimensional computer tomography measurement of semitendinosus tendon harvested for anterior cruciate ligament reconstruction. Arthroscopy. 2006;22(3):259-64.

The limitation in preoperative measurement in relation to flexor grafts is important, as there are reports in the literature that grafts smaller than 8 mm in diameter increase the chance of ACL reconstruction failure.44 Magnussen RA, Lawrence JT, West RL, Toth AP, Taylor DC, Garrett WE. Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft. Arthroscopy. 2012;28(4):526-31.,1616 Grood ES, Walz-Hasselfeld KA, Holden JP, Noyes FR, Levy MS, Butler DL, et al. The correlation between anterior-posterior translation and cross-sectional area of anterior cruciate ligament reconstructions. J Orthop Res. 1992;10(6):878-85.

17 Conte EJ, Hyatt AE, Gatt CJ, Dhawan A. Hamstring autograft size can be predicted and is a potential risk factor for anterior cruciate ligament reconstruction failure. Arthroscopy. 2014;30(7):882-90.

18 Mariscalco MW, Flanigan DC, Mitchell J, Pedroza AD, Jones MH, Andrish JT, et al. The influence of hamstring autograft size on patient-reported outcomes and risk of revision after anterior cruciate ligament reconstruction: a Multicenter Orthopaedic Outcomes Network (MOON) Cohort Study. Arthroscopy. 2013;29(12):1948-53.
-1919 Park SY, Oh H, Park S, Lee JH, Lee SH, Yoon KH. Factors predicting hamstring tendon autograft diameters and resulting failure rates after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2013;21(5):1111-8.

The present study is aimed at performing the preoperative measurement of the knee flexor tendons with ultrasound imaging, and to validate and correlate the measured value with that found during the surgical reconstruction of the ligament.

Material and methods

This is a cross-sectional study submitted and approved by the Research Ethics Committee of the institution in which the study was conducted. The inclusion criteria were patients with clinical and radiological diagnosis of ACL injury who underwent surgical reconstruction of this ligament using an autograft from the semitendinosus and gracilis tendons of the ipsilateral limb, who agreed to participate in the study and signed the Informed Consent Form. The non-inclusion criteria were patients in whom flexor grafts were used for a previous surgical procedure and patients with rheumatologic diseases. The exclusion criteria were patients who for any reason, despite having been scheduled to receive a semitendinosus-gracilis graft, received grafts other than the flexor graft during surgery, and patients who chose not to participate in the study.

Ultrasound evaluation

The diameter of the semitendinosus and gracilis tendons was measured one week before the surgical procedure by a preoperative ultrasound evaluation of the knee. The same radiologist performed all the exams using a GE Healthcare Logic P6 device (GE Healthcare, Little Chalfont, UK) with a 7-11 MHz transducer. The patient was positioned in the ventral recumbent position, and the tendons were measured at the articular line; three values were obtained: anteroposterior (AP) diameter and transverse diameter in millimeters (mm), and cross-sectional area in square millimeters (mm2; Fig. 1A and B).

Fig. 1
(A) Ultrasonographic measurement of the semitendinosus muscle tendon in a transverse plane; (B) ultrasonographic measurement of the semitendinosus muscle tendon in an anteroposterior plane.

Surgical procedure and intraoperative measurement

The patients then underwent ACL reconstruction, using a semitendinosus and gracilis flexor tendon graft, always removed by the same orthopedist using the following technique: 3 mm longitudinal incision in the anteromedial region of the leg, beginning 2 mm distal and medial to the tibial tuberosity. Then the semitendinosus and gracilis tendons were dissected and removed with a tendon stripper (Smith & Nephew, London, England). The graft was cleaned and prepared on a specific table for this purpose (Smith & Nephew, London, England). The tendons had their ends sutured and were folded in half together to form a quadruple graft, as routinely used in ligament reconstructions. The graft was then measured with a graft measurement block (Smith & Nephew, London, England), which has orifices for measurement in 0.5 mm increments. The measurements were always made in the central region of the graft to avoid differences in diameter at the extremities caused by sutures or irregularities of the tendons due to their extraction, and to the size of the block in which the graft presented a maximum filling of the measurement hole, without deformation of the graft and with free passage (Fig. 2).

Fig. 2
Intraoperative measurement of quadruple flexor graft size with the appropriate guide.

Statistical analysis

Numerical variables were described as means and standard deviations (SD) and as minimum and maximum values, and categorical variables, as absolute and relative frequencies.

The correlation between the intraoperative measurements and the area calculated by the ultrasound (2 × area of the semitendinosus + 2 × gracilis area) was assessed by Pearson's correlation coefficient (r).

Student's t-test was applied to compare the intraoperative measurement groups (<8 mm and ≥8 mm) with the mean area measurements calculated by ultrasound.

The analyses were performed using SPSS® software version 18, and a significance level of 0.05 was adopted in all cases.

Results

This study included 24 patients with clinical and radiological diagnosis (magnetic resonance imaging) of ACL injury who underwent surgical ACL reconstruction, with ipsilateral autograft of the semitendinosus and gracilis tendons.

The patients’ ages ranged from 16 to 43 years, with a mean of 24.8 (SD = 8.4); 79.2% were males and the side distribution was 41.7% right and 58.3% left knees.

Table 1 presents the descriptive analyses of the patients’ data and the ultrasound and intraoperative measurements.

Table 1
Patient characteristics, and ultrasonographic and intraoperative measurements (n = 24).

No statistically significant correlation was observed between the area calculated by ultrasound (2 × semitendinosus area + 2 × gracilis area) and the measurement obtained intraoperatively (Fig. 3; r = 0.16; p = 0.443).

Fig. 3
Correlation between the area calculated by ultrasound (2 × semitendinosus area + 2 × gracilis area) and the measurement obtained intraoperatively in a sample of 24 patients.

Furthermore, when categorizing the intraoperative measurements into two groups, <8 mm and ≥8 mm, no statistically significant difference was observed in the area calculated by ultrasound (Table 2; p = 0.746). The differences observed between the groups was −0.01 (95% CI: −0.09 to 0.07).

Table 2
Measurement of the area calculated by ultrasound (2 × semitendinosus + 2 × gracilis area) vs. intraoperative measurement.

Discussion

The most important finding of the present study was that the preoperative ultrasonographic measurement of the semitendinosus and gracilis tendons does not present a statistically significant correlation with the intraoperative measurement of the quadruple flexor graft for ligament reconstruction.

Following the publication of studies showing the importance of flexor graft size and its association with a greater risk of ACL reconstruction failure, specifically when smaller than 8 mm,44 Magnussen RA, Lawrence JT, West RL, Toth AP, Taylor DC, Garrett WE. Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft. Arthroscopy. 2012;28(4):526-31.,1616 Grood ES, Walz-Hasselfeld KA, Holden JP, Noyes FR, Levy MS, Butler DL, et al. The correlation between anterior-posterior translation and cross-sectional area of anterior cruciate ligament reconstructions. J Orthop Res. 1992;10(6):878-85.

17 Conte EJ, Hyatt AE, Gatt CJ, Dhawan A. Hamstring autograft size can be predicted and is a potential risk factor for anterior cruciate ligament reconstruction failure. Arthroscopy. 2014;30(7):882-90.

18 Mariscalco MW, Flanigan DC, Mitchell J, Pedroza AD, Jones MH, Andrish JT, et al. The influence of hamstring autograft size on patient-reported outcomes and risk of revision after anterior cruciate ligament reconstruction: a Multicenter Orthopaedic Outcomes Network (MOON) Cohort Study. Arthroscopy. 2013;29(12):1948-53.
-1919 Park SY, Oh H, Park S, Lee JH, Lee SH, Yoon KH. Factors predicting hamstring tendon autograft diameters and resulting failure rates after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2013;21(5):1111-8. several studies have been conducted in an attempt to preoperatively measure the semitendinosus and gracilis tendons, and to correlate that measurement with the quadruple flexor graft size that would be obtained at the time of surgery.

Anthropometric data have been studied in different populations, but the obtained results are inconsistent, hindering an appropriate correlation between these data and the intraoperative measurement of the quadruple flexor graft.66 Boisvert CB, Aubin ME, DeAngelis N. Relationship between anthropometric measurements and hamstring autograft diameter in anterior cruciate ligament reconstruction. Am J Orthop (Belle Mead NJ). 2011;40(6):293-5.

7 Ma CB, Keifa E, Dunn W, Fu FH, Harner CD. Can pre-operative measures predict quadruple hamstring graft diameter?. Knee. 2010;17(1):81-3.

8 Treme G, Diduch DR, Billante MJ, Miller MD, Hart JM. Hamstring graft size prediction: a prospective clinical evaluation. Am J Sports Med. 2008;36(11):2204-9.
-99 Tuman JM, Diduch DR, Rubino LJ, Baumfeld JA, Nguyen HS, Hart JM. Predictors for hamstring graft diameter in anterior cruciate ligament reconstruction. Am J Sports Med. 2007;35(11):1945-9.,2020 Xie G, Huangfu X, Zhao J. Prediction of the graft size of 4-stranded semitendinosus tendon and 4-stranded gracilis tendon for anterior cruciate ligament reconstruction: a Chinese Han patient study. Am J Sports Med. 2012;40(5):1161-6.,2121 Pichler W, Tesch NP, Schwantzer G, Fronhöfer G, Boldin C, Hausleitner L, et al. Differences in length and cross-section of semitendinosus and gracilis tendons and their effect on anterior cruciate ligament reconstruction: a cadaver study. J Bone Joint Surg Br. 2008;90(4):516-9.

Studies that used imaging tests for the preoperative measurement of the semitendinosus and gracilis tendons have presented a better correlation with the intraoperative measurement. In addition to several studies with magnetic resonance imaging,1010 Bickel BA, Fowler TT, Mowbray JG, Adler B, Klingele K, Phillips G. Preoperative magnetic resonance imaging cross-sectional area for the measurement of hamstring autograft diameter for reconstruction of the adolescent anterior cruciate ligament. Arthroscopy. 2008;24(12):1336-41.

11 Han Y, Kurzencwyg D, Hart A, Powell T, Martineau PA. Measuring the anterior cruciate ligament's footprints by three-dimensional magnetic resonance imaging. Knee Surg Sports Traumatol Arthrosc. 2012;20(5):986-95.

12 Wernecke G, Harris IA, Houang MT, Seeto BG, Chen DB, MacDessi SJ. Using magnetic resonance imaging to predict adequate graft diameters for autologous hamstring double-bundle anterior cruciate ligament reconstruction. Arthroscopy. 2011;27(8):1055-9.

13 Leiter J, Elkurbo M, McRae S, Chiu J, Froese W, MacDonald P. Using pre-operative MRI to predict intraoperative hamstring graft size for anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2017;25(1):229-35.
-1414 Erquicia JI, Gelber PE, Doreste JL, Pelfort X, Abat F, Monllau JC. How to improve the prediction of quadrupled semitendinosus and gracilis autograft sizes with magnetic resonance imaging and ultrasonography. Am J Sports Med. 2013;41(8):1857-63.,2222 Beyzadeoglu T, Akgun U, Tasdelen N, Karahan M. Prediction of semitendinosus and gracilis autograft sizes for ACL reconstruction. Knee Surg Sports Traumatol Arthrosc. 2012;20(7):1293-7.,2323 Hamada M, Shino K, Mitsuoka T, Abe N, Horibe S. Cross-sectional area measurement of the semitendinosus tendon for anterior cruciate ligament reconstruction. Arthroscopy. 1998;14(7):696-701. computed tomography with 3-D1515 Yasumoto M, Deie M, Sunagawa T, Adachi N, Kobayashi K, Ochi M. Predictive value of preoperative 3-dimensional computer tomography measurement of semitendinosus tendon harvested for anterior cruciate ligament reconstruction. Arthroscopy. 2006;22(3):259-64. reconstruction and, more recently, ultrasonography have been used.1414 Erquicia JI, Gelber PE, Doreste JL, Pelfort X, Abat F, Monllau JC. How to improve the prediction of quadrupled semitendinosus and gracilis autograft sizes with magnetic resonance imaging and ultrasonography. Am J Sports Med. 2013;41(8):1857-63.

In the study by Erquicia et al.,1414 Erquicia JI, Gelber PE, Doreste JL, Pelfort X, Abat F, Monllau JC. How to improve the prediction of quadrupled semitendinosus and gracilis autograft sizes with magnetic resonance imaging and ultrasonography. Am J Sports Med. 2013;41(8):1857-63. both magnetic resonance imaging (MRI; with magnifications of 2× and 4×) and ultrasound were used. Those authors concluded that the calculation of the cross-sectional area with the three methods was adequate to estimate the size of the quadruple graft flexors in the surgical procedure. While the results obtained with ultrasound were comparable to those of MRI with 2× magnification, 4× MRI presented much higher accuracy. Finally, they asserted that lower limit values with a cross-sectional area of 25 mm2, 17 mm2, and 14 mm2, in relation to the 2× MRI, 4× MRI, and ultrasound, respectively, would be adequate to predict a flexor graft with at least 8 mm.

The present study contradicts the results obtained by Erquicia et al.1414 Erquicia JI, Gelber PE, Doreste JL, Pelfort X, Abat F, Monllau JC. How to improve the prediction of quadrupled semitendinosus and gracilis autograft sizes with magnetic resonance imaging and ultrasonography. Am J Sports Med. 2013;41(8):1857-63. in relation to the minimum value in ultrasound measurement of 14 mm2 as an adequate value to predict the minimum value of 8 mm for the flexor graft. In the present study, some patients who presented values greater than 14 mm2 by ultrasound had grafts smaller than 8 mm in the surgery. Regarding grafts obtained greater than 8 mm, the smallest area obtained on ultrasonography was 24 mm2. This difference may due to the fact that the ultrasound imaging is operator-dependent and that, specifically in the case of tendon measurement by this radiological method, in which the tendons undergo spatial deformation according to the pressure applied with the transducer by the examiner, it is not possible to quantify and standardize it. Thus, this test was not reproducible in relation to previous studies.

The authors aimed studying the use of ultrasonography in the measurement of the semitendinosus and gracilis tendons preoperatively due to the accessibility and the low cost of this exam, aspects of relevant importance in Brazil, especially in public health service. MRI, although routinely done in cases of ligament injury, is not usually performed using the specific techniques proposed for semitendinosus and gracilis tendon measurements in published studies. Thus, for preoperative measurement, ultrasound would be a more practical and cheaper method in Brazil. However, the hypothesis that ultrasonography would be a suitable exam to predict quadruple flexor graft size was not confirmed.

One of the limitations of the present study is the fact that the semitendinosus and gracilis tendons were not measured in the intraoperative period and were not associated with the data obtained by ultrasound imaging. Perhaps in this way some correlation could have been found, rather than simply comparing with the measurement of the graft already in quadruple format, despite the actions implemented in the measurement to avoid discrepancies. Another limitation was the nonuse of another (more specific) method for intraoperative measurement, since the measurement guides present in the materials routinely used for reconstruction of the ACL show increments of only 0.5 mm, which in itself weakens the correlation with the ultrasound measurements, in which the values are accurate up to the second decimal place. Studies using an intraoperative tool with higher measurement accuracy may better assess the correlation between ultrasound and intraoperative measurement.

Conclusion

Preoperative ultrasound imaging of the semitendinosus and gracilis muscle tendons does not present a statistically significant correlation with the intraoperative measurement of the quadruple flexor graft for ligament reconstruction.

  • Study conducted at Universidade Federal de São Paulo, Escola Paulista de Medicina, Centro de Ortopedia e Traumatologia do Esporte (CETE), São Paulo, SP, Brazil.

REFERENCES

  • 1
    Kim S, Bosque J, Meehan JP, Jamali A, Marder R. Increase in outpatient knee arthroscopy in the United States: a comparison of National Surveys of Ambulatory Surgery, 1996 and 2006. J Bone Joint Surg Am. 2011;93(11):994-1000.
  • 2
    Bartlett RJ, Clatworthy MG, Nguyen TN. Graft selection in reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br. 2001;83(5):625-34.
  • 3
    West RV, Harner CD. Graft selection in anterior cruciate ligament reconstruction. J Am Acad Orthop Surg. 2005;13(3):197-207.
  • 4
    Magnussen RA, Lawrence JT, West RL, Toth AP, Taylor DC, Garrett WE. Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft. Arthroscopy. 2012;28(4):526-31.
  • 5
    Arliani GG, Astur Dda C, Kanas M, Kaleka CC, Cohen M. Anterior cruciate ligament injury: treatment and rehabilitation. Current perspectives and trends. Rev Bras Ortop. 2012;47(2):191-6.
  • 6
    Boisvert CB, Aubin ME, DeAngelis N. Relationship between anthropometric measurements and hamstring autograft diameter in anterior cruciate ligament reconstruction. Am J Orthop (Belle Mead NJ). 2011;40(6):293-5.
  • 7
    Ma CB, Keifa E, Dunn W, Fu FH, Harner CD. Can pre-operative measures predict quadruple hamstring graft diameter?. Knee. 2010;17(1):81-3.
  • 8
    Treme G, Diduch DR, Billante MJ, Miller MD, Hart JM. Hamstring graft size prediction: a prospective clinical evaluation. Am J Sports Med. 2008;36(11):2204-9.
  • 9
    Tuman JM, Diduch DR, Rubino LJ, Baumfeld JA, Nguyen HS, Hart JM. Predictors for hamstring graft diameter in anterior cruciate ligament reconstruction. Am J Sports Med. 2007;35(11):1945-9.
  • 10
    Bickel BA, Fowler TT, Mowbray JG, Adler B, Klingele K, Phillips G. Preoperative magnetic resonance imaging cross-sectional area for the measurement of hamstring autograft diameter for reconstruction of the adolescent anterior cruciate ligament. Arthroscopy. 2008;24(12):1336-41.
  • 11
    Han Y, Kurzencwyg D, Hart A, Powell T, Martineau PA. Measuring the anterior cruciate ligament's footprints by three-dimensional magnetic resonance imaging. Knee Surg Sports Traumatol Arthrosc. 2012;20(5):986-95.
  • 12
    Wernecke G, Harris IA, Houang MT, Seeto BG, Chen DB, MacDessi SJ. Using magnetic resonance imaging to predict adequate graft diameters for autologous hamstring double-bundle anterior cruciate ligament reconstruction. Arthroscopy. 2011;27(8):1055-9.
  • 13
    Leiter J, Elkurbo M, McRae S, Chiu J, Froese W, MacDonald P. Using pre-operative MRI to predict intraoperative hamstring graft size for anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2017;25(1):229-35.
  • 14
    Erquicia JI, Gelber PE, Doreste JL, Pelfort X, Abat F, Monllau JC. How to improve the prediction of quadrupled semitendinosus and gracilis autograft sizes with magnetic resonance imaging and ultrasonography. Am J Sports Med. 2013;41(8):1857-63.
  • 15
    Yasumoto M, Deie M, Sunagawa T, Adachi N, Kobayashi K, Ochi M. Predictive value of preoperative 3-dimensional computer tomography measurement of semitendinosus tendon harvested for anterior cruciate ligament reconstruction. Arthroscopy. 2006;22(3):259-64.
  • 16
    Grood ES, Walz-Hasselfeld KA, Holden JP, Noyes FR, Levy MS, Butler DL, et al. The correlation between anterior-posterior translation and cross-sectional area of anterior cruciate ligament reconstructions. J Orthop Res. 1992;10(6):878-85.
  • 17
    Conte EJ, Hyatt AE, Gatt CJ, Dhawan A. Hamstring autograft size can be predicted and is a potential risk factor for anterior cruciate ligament reconstruction failure. Arthroscopy. 2014;30(7):882-90.
  • 18
    Mariscalco MW, Flanigan DC, Mitchell J, Pedroza AD, Jones MH, Andrish JT, et al. The influence of hamstring autograft size on patient-reported outcomes and risk of revision after anterior cruciate ligament reconstruction: a Multicenter Orthopaedic Outcomes Network (MOON) Cohort Study. Arthroscopy. 2013;29(12):1948-53.
  • 19
    Park SY, Oh H, Park S, Lee JH, Lee SH, Yoon KH. Factors predicting hamstring tendon autograft diameters and resulting failure rates after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2013;21(5):1111-8.
  • 20
    Xie G, Huangfu X, Zhao J. Prediction of the graft size of 4-stranded semitendinosus tendon and 4-stranded gracilis tendon for anterior cruciate ligament reconstruction: a Chinese Han patient study. Am J Sports Med. 2012;40(5):1161-6.
  • 21
    Pichler W, Tesch NP, Schwantzer G, Fronhöfer G, Boldin C, Hausleitner L, et al. Differences in length and cross-section of semitendinosus and gracilis tendons and their effect on anterior cruciate ligament reconstruction: a cadaver study. J Bone Joint Surg Br. 2008;90(4):516-9.
  • 22
    Beyzadeoglu T, Akgun U, Tasdelen N, Karahan M. Prediction of semitendinosus and gracilis autograft sizes for ACL reconstruction. Knee Surg Sports Traumatol Arthrosc. 2012;20(7):1293-7.
  • 23
    Hamada M, Shino K, Mitsuoka T, Abe N, Horibe S. Cross-sectional area measurement of the semitendinosus tendon for anterior cruciate ligament reconstruction. Arthroscopy. 1998;14(7):696-701.

Publication Dates

  • Publication in this collection
    Jul-Aug 2018

History

  • Received
    12 Dec 2016
  • Accepted
    23 Feb 2017
  • Published
    08 June 2018