Maximum phonation time in the pulmonary function assessment

ABSTRACT

Purpose:

to evaluate the reliability of the maximum phonation time (MPT) and Vital Capacity intra and inter-examiner, by means of the single-breath counting test (CT) and the sustained /a/ phoneme, and the slow vital capacity (SVC).

Methods:

a reliability study carried out in three groups of healthy individuals, each group with 30 volunteers, allocated according to age. SVC was measured using a spirometer, while the MPT was assessed by the phoneme /a/ and CT. The data were analyzed using SPSS version 20.0. Initially, descriptive statistics were used and for data reliability, the intraclass correlation coefficient (ICC).

Results:

the Intraclass Correlation Coefficients (ICC) were considered excellent, with significant results above 0.92 for SVC and greater than 0.79 for CT and phoneme /a/. Regarding the inter-examiner evaluation, the ICCs were also significant for both SVC with values greater than 0.96, and for CT and the phoneme /a/ with values greater than 0.85. The error inherent in the technique was assessed using the standard error of the measurement for intra and inter-examiner analyses with values ranging from 1.79 to 3.29 for phoneme /a/, 3.20 to 6.58 for CT and 65, 05 to 206.73 for SVCml.

Conclusion:

phonation techniques with the phoneme /a/ and CT, as well as SVC, have an excellent reliability, due to intra and inter-examiner agreement measures.

Keywords:
Phonation; Vital Capacity; Spirometry; Health Assessment