Almawazini et al.(2020. Almawazini AM, Hanafi HK, Madkhali HA, Majrashi NB. Effectiveness of the critical congenital heart disease screening program for early diagnosis of cardiac abnormalities in newborn infants. Saudi Med J. 2017;38(10):1019–24. doi: http://dx.doi.org/10.15537/smj.2017.10.20295. PubMed PMID: 28917066. https://doi.org/10.15537/smj.2017.10.202...
) |
2.961 |
12 a 24 |
≥95%: sem condutas adicionais. 90–94%: nova avaliação em 1 hora. Persistindo inferior a 95% era realizado ecocardiograma. <90%: realizado ecocardiograma. |
Andrews et al.(2121. Andrews JP, Ross AS, Salazar MA, Tracy NA, Burke Jr BL. Smooth implementation of critical congenital heart defect screening in a newborn nursery. Clin Pediatr. 2014;53(2):173–6. doi: http://dx.doi.org/10.1177/0009922813502850. PubMed PMID: 24037922. https://doi.org/10.1177/0009922813502850...
) |
1.908 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: três novas avaliações em 1, 2 e 3 horas. Persistindo inferior a 95% era realizado ecocardiograma. <90%: realização de ecocardiograma. |
Arlettaz et al.(2222. Arlettaz R, Bauschatz AS, Monkhoff M, Essers B, Bauersfeld U. The contribution of pulse oximetry to the early detection of congenital heart disease in newborns. Eur J Pediatr. 2006;165(2):94–8. doi: http://dx.doi.org/10.1007/s00431-005-0006-y. PubMed PMID: 16211399. https://doi.org/10.1007/s00431-005-0006-...
) |
3.257 |
6 a 12 |
≥95%: sem condutas adicionais. 90–94%: nova avaliação em 6 horas. Persistindo inferior a 95% era realizado ecocardiograma. <90%: realização de ecocardiograma. |
Van Naarden Braun et al.(2323. Van Naarden Braun K, Grazel R, Koppel R, Lakshminrusimha S, Lohr J, Kumar P, et al. Evaluation of critical congenital heart defects screening using pulse oximetry in the neonatal intensive care unit. J Perinatol. 2017;37(10):1117–23. doi: http://dx.doi.org/10.1038/jp.2017.105. PubMed PMID: 28749481. https://doi.org/10.1038/jp.2017.105...
) |
3.423 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: duas novas avaliações em 1 e 2 horas. Persistindo inferior a 95% era realizado ecocardiograma. <90%: Realizado ecocardiograma. |
Cubells et al.(2424. Cubells E, Torres B, Nuñez-Ramiro A, Sánchez-Luna M, Izquierdo I, Vento M. Congenital critical heart defect screening in a health area of the community of Valencia (Spain): a prospective observational study. Int J Neonatal Screen. 2018;4(1):3. doi: http://dx.doi.org/10.3390/ijns4010003. PubMed PMID: 33072929. https://doi.org/10.3390/ijns4010003...
) |
8.856 |
24 a 48 |
>95%: sem condutas adicionais. 90–95%: nova avaliação em uma hora. Persistindo inferior a 94% era realizado ecocardiograma. <90%: admissão na UTIN e realização de ecocardiograma. |
Diller et al.(2525. Diller CL, Kelleman MS, Kupke KG, Quary SC, Kochilas LK, Oster ME. A modified algorithm for critical congenital heart disease screening using pulse oximetry. Pediatrics. 2018;141(5):1–7. doi: http://dx.doi.org/10.1542/peds.2017-4065. PubMed PMID: 29691284. https://doi.org/10.1542/peds.2017-4065...
) |
77.154 |
até 24 |
≥95%: sem condutas adicionais. 90–94%: nova avaliação entre 1 e 2 horas. Persistindo inferior a 94% era realizado ecocardiograma. <90%: realização de ecocardiograma. |
Donia e Tolba(2626. Donia AES, Tolba OA. Use of early pulse oximetry in the detection of cardiac lesions among asymptomatic term newborns. Gaz Egypt Paediatr Assoc. 2016;64(1):1–5. doi: http://dx.doi.org/10.1016/j.epag.2016.02.001. https://doi.org/10.1016/j.epag.2016.02.0...
) |
120 |
2 a 24 |
≥95%: sem condutas adicionais. <95%: nova avaliação em 2 horas. Persistindo inferior a 95% era realizado ecocardiograma. |
Gamhewage et al.(2727. Gamhewage NC, Perera KSY, Weerasekera M. Effectiveness of newborn pulse oximetry screening for the identification of critical congenital heart disease in a tertiary care hospital in Sri Lanka. Sri Lanka J Child Health. 2021;50(4):699–703. doi: http://dx.doi.org/10.4038/sljch.v50i4.9890. https://doi.org/10.4038/sljch.v50i4.9890...
) |
8.718 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: realizado ecocardiograma. |
Gong et al.(2828. Gong A, Livingston J, Creel L, Ocampo E, McKee-Garrett T, Guillory C. Texas Pulse Oximetry Project: a multicenter educational and quality improvement project for implementation of critical congenital heart disease screening using pulse oximetry. Am J Perinatol. 2017;34(9):856–60. doi: http://dx.doi.org/10.1055/s-0037-1599214. PubMed PMID: 28264208. https://doi.org/10.1055/s-0037-1599214...
) |
11.322 |
24 a 48 |
≥95%: sem condutas adicionais. 90–94%: nova avaliação entre 1 e 2 horas. Persistindo inferior a 94% era realizado ecocardiograma. <90%: realização de ecocardiograma. |
Havelund et al.(2929. Havelund KW, Hulgaard M, Malberg D, Fenger-Gron J. Implementation of pulse oximetry screening in a Danish maternity ward. Dan Med J. 2019;66(11):1–4. PubMed PMID: 31686645.) |
2.796 |
até 24 |
≥95%: sem condutas adicionais. <95%: duas novas avaliações em 30 minutos e 1 hora. Persistindo abaixo de 95% avaliação pediátrica e realização do ecocardiograma. |
Jones et al.(3030. Jones AJ, Howarth C, Nicholl R, Mat-Ali E, Knowles R. The impact and efficacy of routine pulse oximetry screening for CHD in a local hospital. Cardiol Young. 2016;26(7):1397–405. doi: http://dx.doi.org/10.1017/S1047951115002784. PubMed PMID: 26905447. https://doi.org/10.1017/S104795111500278...
) |
10.260 |
2 a 24 |
≥95%: sem condutas adicionais. <95%: nova avaliação em 2 horas. Persistindo inferior a 95% admissão na UTIN e era realizado ecocardiograma. <90%: admissão na UTIN e realização de ecocardiograma. |
Kardasevic et al.(3131. Kardasevic M, Jovanovic I, Samardzic JP. Implementation of congenital heart diseases screening at the Bihac Cantonal Hospital. Mater Sociomed. 2017;29(1):45–7. doi: http://dx.doi.org/10.5455/msm.2017.29.45-47. PubMed PMID: 28484354. https://doi.org/10.5455/msm.2017.29.45-4...
) |
1.745 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: nova avaliação entre 1 e 2 horas. Persistindo inferior a 95% era realizado ecocardiograma. <90% realização de ecocardiograma. |
Manja et al.(3232. Manja V, Mathew B, Carrion V, Lakshminrusimha S. Critical congenital heart disease screening by pulse oximetry in a neonatal intensive care unit. J Perinatol. 2015;35(1):67–71. doi: http://dx.doi.org/10.1038/jp.2014.135. PubMed PMID: 25058746. https://doi.org/10.1038/jp.2014.135...
) |
1.445 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: nova avaliação entre 1 e 2 horas. Persistindo inferior a 95% era realizado ecocardiograma. <90%: realização de ecocardiograma. |
Meberg et al.(3333. Meberg A, Andreassen A, Brunvand L, Markestad T, Moster D, Nietsch L, et al. Pulse oximetry screening as a complementary strategy to detect critical congenital heart defects. Acta Paediatr. 2009;98(4):682–6. doi: http://dx.doi.org/10.1111/j.1651-2227.2008.01199.x. PubMed PMID: 19154526. https://doi.org/10.1111/j.1651-2227.2008...
) |
48.686 |
até 21 |
≥95%: sem condutas adicionais. <95%: realização de exame clínico ou ecocardiograma. |
Meberg et al.(3434. Meberg A, Brügmann-Pieper S, Due Jr R, Eskedal L, Fagerli I, Farstad T, et al. First day of life pulse oximetry screening to detect congenital heart defects. J Pediatr. 2008;152(6):761–5. doi: http://dx.doi.org/10.1016/j.jpeds.2007.12.043. PubMed PMID: 18492511. https://doi.org/10.1016/j.jpeds.2007.12....
) |
57.909 |
24 a 48 |
≥95%: sem condutas adicionais. <95% e sintomático era referenciado para avaliação com pediatra. Paciente assintomático nova avaliação em até 3 horas e persistindo <95% o pediatra era chamado. |
Miller et al.(3535. Miller K, Vig K, Goetz E, Spicer G, Yang AJ, Hokanson JS. Pulse oximetry screening for critical congenital heart disease in planned out of hospital births and the incidence of critical congenital heart disease in the Plain community. J Perinatol. 2016;36(12):1088–91. doi: http://dx.doi.org/10.1038/jp.2016.135. PubMed PMID: 27583398. https://doi.org/10.1038/jp.2016.135...
) |
1.600 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: nova avaliação entre 1 e 2 horas. Persistindo inferior a 95% era realizado ecocardiograma. <90%: realização de ecocardiograma. |
Mohsin et al.(3636. Mohsin M, Humayun KN, Atiq M. Clinical screening for congenital heart disease in newborns at a tertiary care hospital of a developing country. Cureus. 2019;11(6):e4808. doi: http://dx.doi.org/10.7759/cureus.4808. PubMed PMID: 31403007. https://doi.org/10.7759/cureus.4808...
) |
1.650 |
24 a 48 |
≥95%: sem condutas adicionais. ≤94%: nova avaliação em uma hora. Persistindo inferior a 94% era realizado ecocardiograma. |
Mosayebi et al.(3737. Mosayebi Z, Movahedian AH, Amini E, Asbagh PA, Ghorbansabagh V, Shariat M, et al. Evaluation of pulse oximetry in the early diagnosis of cardiac and noncardiac diseases in healthy newborns. Iran. J. Neonatol. 2020;11:43–50. doi: http://dx.doi.org/10.22038/IJN.2019.38511.1608. https://doi.org/10.22038/IJN.2019.38511....
) |
413 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: nova avaliação em até 2 horas. Persistindo inferior a 95% era realizado ecocardiograma. <90%: realizado ecocardiograma. |
Özalkaya et al.(3838. Özalkaya E, Akdagˇ A, S¸en I, Cömert E, Yaren HM. Early screening for critical congenital heart defects in asymptomatic newborns in Bursa province. J Matern Fetal Neonatal Med. 2016;29(7):1105–7. doi: http://dx.doi.org/10.3109/14767058.2015.1035642. PubMed PMID: 25902399. https://doi.org/10.3109/14767058.2015.10...
) |
8.208 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: realização de ecocardiograma. |
Patriciu et al.(3939. Patriciu M, Avasiloaiei A, Moscalu M, Stamatin M. Pulse oximetry during the first 24 hours as a screening tool for congenital heart defects. J Crit Care Med. 2017;3(1):12–7. doi: http://dx.doi.org/10.1515/jccm-2017-0004. PubMed PMID: 29967865. https://doi.org/10.1515/jccm-2017-0004...
) |
5.406 |
até 24 |
≥95%: sem condutas adicionais. <95%: realização de ecocardiograma. |
Prudhoe et al.(4040. Prudhoe S, Abu-Harb M, Richmond S, Wren C. Neonatal screening for critical cardiovascular anomalies using pulse oximetry. Arch Dis Child Fetal Neonatal Ed. 2013;98(4):F346–50. doi: http://dx.doi.org/10.1136/archdischild-2012-302045. PubMed PMID: 23341250. https://doi.org/10.1136/archdischild-201...
) |
29.930 |
2 a 48 |
≥95%: sem condutas adicionais. <95%: realizado ecocardiograma. |
Richmond et al.(4141. Richmond S, Reay G, Abu Harb M. Routine pulse oximetry in the asymptomatic newborn. Arch Dis Child Fetal Neonatal Ed. 2002;87(2):83–8. doi: http://dx.doi.org/10.1136/fn.87.2.F83. PubMed PMID: 12193511. https://doi.org/10.1136/fn.87.2.F83...
) |
5.626 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: nova avaliação em até 2 horas. Persistindo inferior a 95% era realizado ecocardiograma. |
Saxena et al.(4242. Saxena A, Mehta A, Ramakrishnan S, Sharma M, Salhan S, Kalaivani M, et al. Pulse oximetry as a screening tool for detecting major congenital heart defects in Indian newborns. Arch Dis Child Fetal Neonatal Ed. 2015;100(5):F416-21. doi: http://dx.doi.org/10.1136/archdischild-2014-307485. PubMed PMID: 26038347. https://doi.org/10.1136/archdischild-201...
) |
19.009 |
até 48 |
≥95%: sem condutas adicionais. <95%: realização de ecocardiograma. |
Singh et al.(4343. Singh A, Rasiah SV, Ewer AK. The impact of routine predischarge pulse oximetry screening in a regional neonatal unit. Arch Dis Child Fetal Neonatal Ed. 2014;99(4):F297–302. doi: http://dx.doi.org/10.1136/archdischild-2013-305657. PubMed PMID: 24646619. https://doi.org/10.1136/archdischild-201...
) |
25.859 |
até 12 |
≥95%: sem condutas adicionais. <95%: nova avaliação em até 2 horas. Persistindo inferior a 95% admissão na UTIN e era realizado ecocardiograma. |
Tautz et al.(4444. Tautz J, Merkel C, Loersch F, Egen O, Hägele F, Thon HM, et al. Implication of pulse oxymetry screening for detection of congenital heart defects. Klin Padiatr. 2010;222(5):291–5. doi: http://dx.doi.org/10.1055/s-0030-1253391. PubMed PMID: 20458668. https://doi.org/10.1055/s-0030-1253391...
) |
3.336 |
6 a 36 |
≥95%: sem condutas adicionais. 90–94%: nova avaliação entre 4 e 6 horas. Persistindo inferior a 95% era realizado ecocardiograma. <90%: realização de ecocardiograma. |
Tsao et al.(4545. Tsao PC, Shiau YS, Chiang SH, Ho HC, Liu YL, Chung YF, et al. Development of a newborn screening program for Critical Congenital Heart Disease (CCHD) in Taipei. PLoS One. 2016;11(4):e0153407. doi: http://dx.doi.org/10.1371/journal.pone.0153407. PubMed PMID: 27073996. https://doi.org/10.1371/journal.pone.015...
) |
6.296 |
24 a 36 |
≥95%: sem condutas adicionais. <95%: três novas avaliações em 30 minutos, 1 hora e 1 hora e 30 minutos. Persistindo abaixo de 95% realização do ecocardiograma. |
Vaidyanathan et al.(4646. Vaidyanathan B, Sathish G, Mohanan ST, Sundaram KR, Warrier KK, Kumar RK. Clinical screening for Congenital heart disease at birth: a prospective study in a community hospital in Kerala. Indian Pediatr. 2011;48(1):25–30. doi: http://dx.doi.org/10.1007/s13312-011-0021-1. PubMed PMID: 20972295. https://doi.org/10.1007/s13312-011-0021-...
) |
5.487 |
até 48 |
≥95%: sem condutas adicionais. ≤94%: realização de ecocardiograma. |
Walsh(4747. Walsh W. Evaluation of pulse oximetry screening in Middle Tennessee: cases for consideration before universal screening. J Perinatol. 2011;31(2):125–9. doi: http://dx.doi.org/10.1038/jp.2010.70. PubMed PMID: 20508595. https://doi.org/10.1038/jp.2010.70...
) |
14.564 |
24 a 48 |
≥94%: sem condutas adicionais. <94%: avaliação pelo cardiologista pediátrico. |
Zayachnikova et al.(4848. Zayachnikova T, Delryu N, Shishimorov I, Magnitskaya O, Belan E. Accuracy of pulse oximetryfor early detection of critical congenital heart disease in Volgograd region (Russia). Archive Euromedica. 2020;10(2):53–4. doi: http://dx.doi.org/10.35630/2199-885X/2020/10/2.16. https://doi.org/10.35630/2199-885X/2020/...
) |
20.547 |
24 a 48 |
≥95%: sem condutas adicionais. <95%: realização de ecocardiograma. |