Open-access The photoelasticity method in orthodontic research: a scope review

O método da fotoelasticidade na pesquisa ortodôntica: uma revisão de escopo

ABSTRACT

Objective  To systematically map the research carried out in the area of Orthodontics with the application of the photoelasticity method

Methods  Studies reporting experiments that used the photoelasticity method as an instrument to assess stresses produced by any type of craniofacial orthopedic or orthodontic device were included. Searches were performed in the following databases: Medline, Embase, Cochrane Central Register of Controlled Trials Literatura Latino-Americana e do Caribe em Ciências da Saúde, ISI Web of Science, and ProQuest Dissertations & Theses Global. The date of the last search was May 2024, where reviewers independently selected and extracted data from the included studies using standardized forms, and assessed their risk of bias, with the application of the Appraisal for Cross-Sectional Studies tool.

Results  33 studies were included in the review. The photoelasticity method proved to be very versatile, since it was used to analyze various types of orthodontic mechanics and orthopedic appliances in different scenarios. The selected manuscripts presented insufficient or unclear reports, especially in relation to the process of producing the models and the analysis of the results.

Conclusion  This method has been used in several areas of Dentistry, particularly as an adjuvant in orthodontics, offering a fast and effective way to assess stress distribution and orthodontic mechanics in real time. Further studies are encouraged to explore new orthodontic mechanics and document the method’s processes in detail.

Indexing terms
Birefringence; Dental stress analysis; Orthodontics; Systematic review

RESUMO

Objetivo  Mapear sistematicamente a pesquisa realizada na área de Ortodontia com a aplicação do método de fotoelasticidade.

Métodos  Foram incluídos estudos que relataram experimentos que usaram o método de fotoelasticidade como instrumento para avaliar tensões produzidas por qualquer tipo de dispositivo ortopédico ou ortodôntico craniofacial. Pesquisas foram realizadas nas seguintes bases de dados: Medline, Embase, Cochrane Cen tral Register of Controlled Trials, Literatura Latino-Americana e do Caribe em Ciências da Saúde, ISI Web of Science e ProQuest Dissertations & Theses Global. A data da última pesquisa foi maio de 2024, quando os revisores selecionaram e extraíram de forma independente dados dos estudos incluídos usando formulários padronizados e avaliaram seu risco de viés, com a aplicação da ferramenta Appraisal for Cross-Sectional Studies.

Resultados  Trinta e três estudos foram incluídos na revisão. O método de fotoelasticidade provou ser muito versátil, uma vez que foi usado para analisar vários tipos de mecânica ortodôntica e aparelhos ortopédicos em diferentes cenários. Os manuscritos selecionados apresentaram relatórios insuficientes ou pouco claros, especialmente em relação ao processo de produção dos modelos e à análise dos resultados.

Conclusão  Este método tem sido usado em várias áreas da Odontologia, particularmente como adjuvante em ortodontia, oferecendo uma maneira rápida e eficaz de avaliar a distribuição de estresses e a mecânica ortodôntica em tempo real. Outros estudos são incentivados a explorar novas mecânicas ortodônticas e documentar os processos do método em detalhes.

Termos de indexação
Birrefringência; Análise de estresse dentário; Ortodontia; Revisão sistemática

INTRODUCTION

Photoelasticity can be defined as a method of stress analysis based on the property of mechanical birefringence, inherent to several transparent polymers, which makes use of the properties of light polarization and mechanical stress experimentally applied to the bodies of interest [1]. This experimental model is based on the identification of colored stripes, also called fringes that become visible when illuminated by polarized light, which are posteriorly analyzed by a polariscope [2].

It was introduced into dental research by Zak in 1935 [3], when he simulated the effects of various orthodontic devices on human teeth mounted in experimental models. Such method have been presented as a versatile experimental model or the analysis of several orthodontic and orthopedic therapeutic mechanics [4-6]. As well as the Finite Element Method, both techniques have been traditionally used to analyze tensions as complimentary experimental designs. However, the photoelastic method present relatively lower costs to be implemented, in addition to enable the simultaneous visualization and analysis of tensions [2,7,8].

Since Glickman et al. [9] published a study using the photoelasticity method in dental research, according to which they established a positive correlation between histological findings and areas of stress concentration in photoelastic models, the use of this experimental method has been applied to several areas of research, such as Prosthesis [10,11], Implantology [12-14], Clinical Dentistry [15,16], Oral Surgery [17,18], or Occlusion [19]. In Orthodontics, most studies that used this model investigated canine retraction mechanics and tensions generated by orthopedic appliances, in addition to incisors intrusion and molar verticalization techniques, maxillary expansion, and several mechanics supported by temporary anchorage devices [20-29].

Considering the recognition of potentially deficient methodological points in the literature and the identification of knowledge gaps regarding the application of this method to the investigation of orthodontic mechanics, a scoping review was conducted in order to systematically map the research carried out in the area of Orthodontics with the application of the photoelasticity method.

METHODS

Protocol and registration

This review was reported according to the requirements in Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) [30] and was registered in the Open Science Framework (OSF) https://osf.io/search?activeFilters=%5B%5D&q=10.17605%2FOSF.IO%2FPDHE2&sort=-relevance&view_only=; https://doi.org/10.17605/OSF.IO/PDHE2).

Search and eligibility criteria

Studies reporting experiments that used the photoelasticity method as an instrument to assess, individually or comparatively, stresses produced by any type of craniofacial orthopedic or orthodontic device were included. Studies reporting duplicate results were excluded. There were no restrictions on language or publication date.

Information sources

Studies were searched from the following sources: Cochrane Central Register of Controlled Trials (CENTRAL), Medline, Ovid Embase, Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs) and ISI Web of Science from inception to June 2024. Search terms describing photoelasticity and orthodontics were combined using Boolean logical operators as shown in figure 1. The gray literature was partially covered by consulting the ProQuest Dissertations & Theses Global database and conference annals. Additionally, we analyzed the reference lists of potentially eligible studies.

Figure 1
Search strategy.

Selection of evidence sources

After analyzing titles and abstracts resulting from the electronic search, two reviewers independently pre-selected studies, with the aid of the online Covidence software (https://www.covidence.org). This program was also used to identify and exclude duplicate research reports. Posteriorly, full-text records for potentially eligible studies were obtained. These studies were independently selected by the same reviewers, according to the same eligibility criteria. Consensus for the screening and selection phases was established by discussion with a third reviewer, as needed.

Process of extracting data and items

The characteristics of the experimental method were considered as outcomes of interest, as well as the production of the photoelastic models, materials, method of analysis of the results, and types of mechanics and malocclusions. Two reviewers collected data from the included studies independently using a standardized data extraction forms as shown by chart 1. Discrepancies at this stage were resolved after review of the original document and discussion with a third reviewer (RABS), if necessary.

Chart 1
Standardized data extraction form.

Critical appraisal of individual sources of evidence

Studies were evaluated according to the modified version of the Appraisal for Cross-Sectional Studies (AXIS) tool [31] to assess their risk of bias. Two reviewers independently reviewed the included studies. Discrepancies were resolved by discussion with a third reviewer.

Summary of results

The results were summarized and presented qualitatively, as meta-analyses were not considered adequate for the synthesis of heterogeneous data.

RESULTS

Selection of evidence sources

The electronic search yielded 385 records. After excluding duplicates and including records by manual search, 358 titles and abstracts were obtained. During the screening phase, 51 studies were retrieved for full-text reading, out of which 18 were excluded. Those eliminated during the final selection phase, and the respective justifications for their exclusion are presented in chart 2. Finally, 33 studies met the eligibility criteria and were included in this review (figure 2).

Chart 2
Excluded Study Sheet.
Figure 2
Flowchart of the bibliographic research and selection of articles.

Characteristics of sources of evidence

The included studies dated from 1974 to 2021, and were characterized according to: type of specimens, mold and photoelastic model material, use of vacuum chamber, performance of rest tests, work time, characteristics of the polariscope, reference of tension produced, and tested clinical scenario. The results collected from the included studies are detailed in table 1.

Table 1
Standard form for critical evaluation of studies.

Critical appraisal of individual sources of evidence

All included studies made their objective clear, and employed the appropriate design. Two studies [24,32] did not clearly define the specimens used, and few adopted species from real patients [33,34]. A relevant part of the studies did not measure outcomes or did not clearly report them [21-25,32,35-39]. In this sense, the citation of a reference table for quantitative characterization of the results is occasionally observed [29,33,40-47].

Furthermore, there were few experiments that clearly defined parameters of significance for eventual statistical analysis [29,33,40-42,47]. The smallest portion of the studies showed adequacy in the description of data [4,6,20,29,33,40-45,48-50]. More details about the quality analysis of the included studies can be found in table 3.

Summary of results

The included studies used similar materials with birefringence properties to produce the photoelastic model, namely flexible epoxy resin [29,40,41,47], photoelastic epoxy [6], epoxy resin [37,42,46,50] photoelastic resin [4,20–28,39,43-45], epoxy resin urethane [48], epoxy plastic [49], gelatine [33,34], birefringent urethane plastic [35], epoxy birefringent plastic [36]. Urethane [5], and araldite [32]. As part of the photoelastic model production, all studies cited silicone as the recommended molding material [6,22,23,25,26,29,33,34,37,40-45,48-50].

Few studies reported the use of a vacuum chamber during specimen preparation [6,20,24,29,33,40,42]. Amongst the ones that reported resting time after specimen preparation, a large variability was observed (24 hours [42], 72 hours [40], 168 hours [20,24]).

A great versatility was observed in relation to the types of photoelastic models. Some of the included studies [7,43] described rectangular models, so that only the teeth of interest were fixed. Others [5,22,25-28,36,46,49] described full-face photoelastic models. There were also studies that reported the elaboration of integral [33,35,39,42,45,50] or partial maxillary models [21,38]. The development of mandibular models was also described, whether integral [4,33-35,40,44,47] or partial [6,20,29,41,48]. Still, a single study described the construction of a model after the molding of a cat’s mandible [23].

The vast majority of studies used the circular polariscope, with the exception of two [40,42] which used the reflection polariscope, and two others [4,37], which used the plane polariscope. Most of the studies reported baseline checking of the model [4-6,20,24,26,29,34,36,40-46,48,49].

As for the method of tension analysis, few studies have described the results using reference tables [6,29,33,40-46], and the results were mostly described only with the qualitative characterization of the fringe colors [4,5,7,20-28,32,34-39,48-50].

Interestingly several scenarios and orthodontic mechanics were reproduced for photoelastic analysis. For instance, open-bite correction methods were investigated [40], as well as various methods for lower molars uprighting [41]. The correction of models with lower incisor crowding using different wires, such as NiTi round and rectangular wires, ISW (improved superelastic NiTi alloy wire), and stainless steel [6,33] were investigated.

There were also experiments that verified tensions caused by incisor intrusion mechanics [42]. Studies have also evaluated different types of wires associated with conventional and self-ligating brackets [4]. Forces applied to orthodontic mini-implants at different angles [43] and maxillary expansion appliances were also the subject of experiments [37,46,49].

Part of the studies included here also proposed the comparative analysis of retraction mechanics [7,39] and Class II correction using the Friction Free Distalize Appliance [38]. In addition, tensions caused by lower molar distalization using cortical anchorage and an open spring [48], as well as crossbite correction using an elastic chain and fixed appliance [44,45] were evaluated. One of the experiments reported the analysis of the center of resistance in cases of maxillary incisor retraction [50], while another one was dedicated to the analysis of torque in polycarbonate brackets [32].

A relevant proportion of the studies investigated canine retraction methods [20,21,23,26,47] and also the anchorage conjugating adjacent teeth in comparison to mini-implants in canine retraction [29].

The action of several orthopedic appliances, such as: Bionator, Nance holding arch, lingual arch, acrylic fixed appliance with a buccal arch wire, chin-cup, cervical and headgear appliances [5,24-28,36], was investigated. Mechanics of leveling the curve of Spee [34], as well as Class III correction using intermaxillary elastic [22,35] were also analyzed.

DISCUSSION

The photoelasticity method has proved to be extremely versatile for the analysis of various orthodontic and orthopedic mechanics, and it has been used for analyzing scenarios ranging from tooth alignment [4,6,33] to more complex mechanics with the use of mini-implants [29,48] and rapid maxillary expansion [37,46,49].

Photoelasticity and the finite element methods have been both considered as important and complementary experimental techniques for stress analysis [8], since whenever possible, they could be applied for the same experimental purposes, enabling the validation of the results. However, the photoelasticity method refers to a relatively lower cost evaluation tool, which enables simultaneous visualization of tensions, which can be measured and photographed instantly. As for the finite element method, however, software, graphs and force distribution schemes built from numerical data are required. Even though the finite element model can simulate, in a more detailed fashion, complex shapes, such as dental and periodontal structures, it has been documented a correspondence between the tensions observable in photoelastic models with real-life scenarios [2,7,9,23,51-53]. Nevertheless, one of the limitations of the photoelasticity method refers to the dependence on the simulation of physical models similar to the original scenario, as well as the restriction of maximum force that can be applied to the model, which must not exceed the limit of the photoelastic material.

There are reports of several types of photoelastic materials, such as: flexible epoxy resin [29,40,41,47], photoelastic epoxy [6], epoxy resin [37,42,46,50], photoelastic resin [4,20-28,39,43-45], epoxy resin urethane [48], epoxy plastic [49], gelatine [33,34], birefringent urethane plastic [35], epoxy birefringent plastic [36], urethane [5], and araldite [32], where all respected the properties of birefringent materials. There were also some studies that did not mention the type of material used [7,38].

The polariscope refers to a system consisting of a set of optical elements whose objective is to transmit polarized light, in order to produce fringes in birefringent materials, when it undergoes some tension [2,8,54]. Essentially, two models can be used, namely the plane and the circular polariscope. The plane polariscope is composed of two polarizing filters, where the first – called polarizer, has the function of absorbing light waves, and the second (analyzer) is placed behind the photoelastic model to be analyzed. The circular one presents quarter-wave plates between the polarizing and analyzer filters with the function of eliminating the isoclinic fringes, since they are dark and have the potential to interfere in the visualization of the isochromatic fringes, where the voltage magnitude is observed [2,33,54,55]. Considering this advantage, most of the selected studies [5-7,20-24,26-29,33,35,36,39,41,43-46,48-50] used the second model.

In accordance with some studies [2,8,54-56], which have been emphasizing the limitations of photoelasticity, and in view of the unclear or insufficient reports generally observed in most of the studies selected here, it is recommended that future researches should engage efforts to further detailing each experimental method step. In this sense, it seems essential that there is certification and report of the absence of fringes prior to the application of the tension test, ruling out hypotheses of potential interference in the results that could compromise the reliability of the method. Although most studies have carried out an appropriate report in this regard [4-6,20,24,26,29,34,36,40-46,48,49], it is emphasized that in cases of the presence of fringe – indicating the presence of previous tension, it is necessary to insert the model in a stove, in order to carry out a thermal treatment to eliminate residual tension.

Another point that has not been clarified in most of the studies included here refers to the use of a vacuum chamber during the process of models’ production, which has the important function of eliminating potential air bubbles resulting from the initial reaction between the components of the photoelastic resin. The use of this resource was cited in only few of the selected studies [6,20,24,29,33,40,42]. Regarding the rest specification of the model for the complete polymerization of the photoelastic resin, just over half of the selected studies reported having completed this step [6,20,24,29,33,40,42], among which only four specified the rest time [20,24,40,42]. Since this is an important factor in the production of the photoelastic model, it is recommended that the curing time of the material should be respected, according to the manufacturer. Across the studies included in this review, curing time ranged from 24 hours [42], 72 hours [40] to 168 hours [20,24].

The report of the use of a reference table for the analysis of results is a relevant factor in this type of study, which allows the results to be quantitatively compared, not only between scenarios in the same study, but also with those of other studies. The American Society for Testing and Materials has classified photoelastic fringe standards into ordinal numbers, so that each fringe has an identity or so-called fringe order (ASTM D4093-95, 2001). Therefore, the use of a reference table is recommended, as reported by few of the selected studies [6,29,33,40-46].

Most of the studies clearly defined the specimens used, describing their individual characteristics [4-7,20-22,26,28,29,32-35,37,39-46,48-50]. On the other hand, only a minority of studies cited the type of mechanics that were evaluated, not clearly describing the characteristics of the specimens [23-25,27,36,38]. Relevant part of the studies [22-25,32,35-38] also did not pre-define the areas of teeth and/or specimens to be analyzed, being restricted to the description of the results in general. The absence of detailed reports about the specimens and the analyzed areas might hamper comparative analyses, as well as the comprehensive interpretation of the results. Finally, few studies [29,33,40-42] used significance parameters for eventual statistical analysis, which is another important information to be regarded during the interpretation of results.

In view of its versatility, the authors of this review consider that further studies can still be carried out in order to evaluate new orthodontic techniques and mechanics, such as extra-alveolar mini-implants, esthetic aligners, distalization systems, as well as mechanics with self-ligating brackets. In order to seek results resulting from new orthodontic mechanics, the application of the photoelasticity method can enable the production of new parameters that are useful to orthodontists in their clinical practice, provided that further studies pay attention to the conduct and report of each step necessary for the correct execution of this method.

LIMITATIONS

The limitations identified by this study refer, above all, to the frequent incompleteness of information about methods or the lack of clarity in their reports. In addition, there was a lack of standardization in the production of the photoelastic model and in the analysis of the results.

CONCLUSION

It is concluded that the photoelasticity method proved to be very versatile, analyzing various types of orthodontic and orthopedic appliances and mechanics in different scenarios. The selected manuscripts presented generally insufficient or unclear reports, especially in relation to the process of producing the models and the analysis of the results. Further studies are suggested to investigate new orthodontic mechanics and toclearly follow and report all the processes of this method.

  • How to cite this article
    Desimoni MP, Segato RAB, Paschoini-Costa VL, Silva LAB, Nelson Filho P, Feres MFN. The photoelasticity method in orthodontic research: a scope review. RGO, Rev Gaúch Odontol. 2025;73:e20250036. http://dx.doi.org/10.1590/1981-86372025003620240046

Data availability

The research data are available from the corresponding author upon reasonable request

REFERENCES

  • 1 Dolan T, Murray W. Photoelasticity. 6th ed. In: Hetenyi M, editor. Handbook of experimental stress analysis. New York: John Wiley & Sons; 1966. p. 828-976.
  • 2 Campos-Júnior A, Passanezi E, Nahás D, Janson W. Fundamental theoretical bases for the use of photoelasticity as a method of studying forces’ distribution. Estomatol Cult. 1985;15(1):21-4.
  • 3 Zak B. Photoelastic analysis in orthodontic mechanics. Österr Z Stomatol. 1935;33:22-37.
  • 4 Sobral GC, Vedovello Filho M, Degan VV, Santamaria MJ. Photoelastic analysis of stress generated by wires when conventional and self-ligating brackets are used: a pilot study. Dental Press J Orthod. 2014;19(5):74-8. https://doi.org/10.1590/2176-9451.19.5.074-078.oar
    » https://doi.org/10.1590/2176-9451.19.5.074-078.oar
  • 5 Stefanac J, Chaconas SJ, Caputo AA, Griffith J. Photoelastic evaluation of the standard bionator appliance. J Oral Rehabil. 1993;20(5):549-59. https://doi.org/10.1111/j.1365-2842.1993.tb01642.x
    » https://doi.org/10.1111/j.1365-2842.1993.tb01642.x
  • 6 Chiang P-C, Lin S-L, Liu M-J, Fan K-H, Chang W-J, Lee S-Y, et al. Photoelastic analysis of stress distributions in the root-bone interface when applying various orthodontic methods to subside lower anterior crowding. Proc Inst Mech Eng H. 2018;232(10):999-1007. https://doi.org/10.1177/0954411918796046
    » https://doi.org/10.1177/0954411918796046
  • 7 Maia LGM, Moraes Maia ML, Costa Monini A, Vianna AP, Gandini LGJ. Photoelastic analysis of forces generated by T-loop springs made with stainless steel or titanium-molybdenum alloy. Am J Orthod Dentofac Orthop. 2011;140(3):e123-8. https://doi.org/10.1016/j.ajodo.2011.03.020
    » https://doi.org/10.1016/j.ajodo.2011.03.020
  • 8 Freitas Junior A, Rocha E, Assunção W, Santos P. Bioengineering applied to odontology: finite element analysis versus photoelasticity. Implantnews. 2007;4(5):469-76.
  • 9 Glickman I, Roeber FW, Brion M, Pameijer JH. Photoelastic analysis of internal stresses in the periodontium created by occlusal forces. J Periodontol. 1970;41(1):30-5. https://doi.org/10.1902/jop.1970.41.1.30
    » https://doi.org/10.1902/jop.1970.41.1.30
  • 10 Pereira IP, Consani RLX, Mesquita MF, Nóbilo MAA. Photoelastic analysis of stresses transmitted by complete dentures lined with hard or soft liners. Mater Sci Eng C Mater Biol Appl. 2015;55:181-6. https://doi.org/10.1016/j.msec.2015.05.020
    » https://doi.org/10.1016/j.msec.2015.05.020
  • 11 Ferraço R, Pellizzer EP, Tonella BP, Falcón-Antenucci RM, Verri FR, Dekon SFC, et al. Photoelastic analysis of the influence of residual ridge inclination in conjugated class I mandibular prostheses with different attachment systems. Acta Odontol Scand. 2013;71(3-4):984-8. https://doi.org/10.3109/00016357.2012.741697
    » https://doi.org/10.3109/00016357.2012.741697
  • 12 Pigozzo MN, Laganá DC, Sesma N, Souza GF, Ichi AL. Photoelastic stress analysis in mandibular bone surrounding bar-clip overdenture implants. Braz Oral Res. 2014;28. https://doi.org/10.1590/s1806-83242013005000034
    » https://doi.org/10.1590/s1806-83242013005000034
  • 13 Zaparolli D, Peixoto RF, Pupim D, Macedo AP, Toniollo MB, Mattos MGC. Photoelastic analysis of mandibular full-arch implant-supported fixed dentures made with different bar materials and manufacturing techniques. Mater Sci Eng C Mater Biol Appl. 2017;81:144-7. https://doi.org/10.1016/j.msec.2017.07.052
    » https://doi.org/10.1016/j.msec.2017.07.052
  • 14 Ozyilmaz OY, Aykent F, Sayin Ozel G. Effect of mucosa thicknesses on stress distribution of implant-supported overdentures under unilateral loading: photoelastic analysis. J Appl Biomater Funct Mater. 2019;17(4):2280800019882645. https://doi.org/10.1177/2280800019882645
    » https://doi.org/10.1177/2280800019882645
  • 15 Lopes MB, Valarini N, Moura SK, Guiraldo RD, Gonini Júnior A. Photoelastic analysis of stress generated by a silorane-based restoration system. Braz Oral Res. 2011;25(4):302-6. https://doi.org/10.1590/s1806-83242011000400004
    » https://doi.org/10.1590/s1806-83242011000400004
  • 16 Pereira R, Giorgi MCC, Lins RBE, Theobaldo JD, Lima DANL, Marchi GM, et al. Physical and photoelastic properties of bulk-fill and conventional composites. Clin Cosmet Investig Dent. 2018;10:287-96. https://doi.org/10.2147/CCIDE.S184660
    » https://doi.org/10.2147/CCIDE.S184660
  • 17 Rodrigues DC, Falci SGM, Lauria A, Marchiori EC, Moreira RWF. Mechanical and photoelastic analysis of four different fixation methods for mandibular body fractures. J Cranio-Maxillo-Facial Surg. 2015;43(3):306-11. https://doi.org/10.1016/j.jcms.2014.11.021
    » https://doi.org/10.1016/j.jcms.2014.11.021
  • 18 Oliveira DL, Souza Batista VE, Holobenko L, Santiago Junior JF, Pellizzer EP, Ribeiro Junior PD. Photoelastic analysis of conventional and locking system for treatment of mandibular angle fractures with a single plate. J Clin Exp Dent. 2021;13(4):e328-e33. https://doi.org/10.4317/jced.56916
    » https://doi.org/10.4317/jced.56916
  • 19 Rossi AC, Freire AR, Prado FB, Asprino L, Correr-Sobrinho L, Caria PHF. Photoelastic and finite element analyses of occlusal loads in mandibular body. Anat Res Int. 2014;2014:174028. https://doi.org/10.1155/2014/174028
    » https://doi.org/10.1155/2014/174028
  • 20 Caputo AA, Chaconas SJ, Hayashi RK. Photoelastic visualization of orthodontic forces during canine retraction. Am J Orthod. 1974;65(3):250-9. https://doi.org/10.1016/s0002-9416(74)90330-3
    » https://doi.org/10.1016/s0002-9416(74)90330-3
  • 21 Baeten LR. Canine retraction: a photoelastic study. Am J Orthod. 1975;67(1):11-23. https://doi.org/10.1016/0002-9416(75)90125-6
    » https://doi.org/10.1016/0002-9416(75)90125-6
  • 22 de Alba y Levy JA, Caputo AA, Chaconas SJ. Effects of orthodontic intermaxillary Class III mechanics on craniofacial structures. Part I - photoerlastic analysis. Angle Orthod. 1979;49(1):21-8.
  • 23 Brodsky JF, Caputo AA, Furstman LL. Root tipping: a photoelastic-histopathologic correlation. Am J Orthod. 1975;67(1):1-10. https://doi.org/10.1016/0002-9416(75)90124-4
    » https://doi.org/10.1016/0002-9416(75)90124-4
  • 24 Hayashi RK, Chaconas SJ, Caputo AA. Effects of force direction on supporting bone during tooth movement. J Am Dent Assoc. 1975;90(5):1012-7. https://doi.org/10.14219/jada.archive.1975.0227
    » https://doi.org/10.14219/jada.archive.1975.0227
  • 25 Chaconas SJ, Caputo AA, Davis JC. The effects of orthopedic forces on the craniofacial complex utilizing cervical and headgear appliances. Am J Orthod. 1976;69(5):527-39. https://doi.org/10.1016/s0002-9416(76)80026-7
    » https://doi.org/10.1016/s0002-9416(76)80026-7
  • 26 Ayala Perez C, Alba JA, Caputo AA, Chaconas SJ. Canine retraction with J hook headgear. Am J Orthod. 1980;78(5):538-47. https://doi.org/10.1016/0002-9416(80)90304-8
    » https://doi.org/10.1016/0002-9416(80)90304-8
  • 27 Alfredo de Alba J, Chaconas SJ, Caputo AA, Emison W. Stress distribution under high-pull extraoral chin cup traction. A photoelastic study. Angle Orthod. 1982;52(1):69-78. https://doi.org/10.1043/0003-3219(1982)052<0069:SDUHEC>2.0.CO;2
    » https://doi.org/10.1043/0003-3219(1982)052<0069:SDUHEC>2.0.CO;2
  • 28 Itoh T, Chaconas SJ, Caputo AA, Matyas J. Photoelastic effects of maxillary protraction on the craniofacial complex. Am J Orthod. 1985;88(2):117-24. https://doi.org/10.1016/0002-9416(85)90235-0
    » https://doi.org/10.1016/0002-9416(85)90235-0
  • 29 Assis Claro CA, Chagas RV, Neves ACEC, Silva-Concílio LR. Comparative photoelastic study of dental and skeletal anchorages in the canine retraction. Dental Press J Orthod. 2014;19(1):100-5. https://doi.org/10.1590/2176-9451.19.1.100-105.oar
    » https://doi.org/10.1590/2176-9451.19.1.100-105.oar
  • 30 Tricco AC, Lillie E, Zarin W, O’Brien KK, Colquhoun H, Levac D, et al. PRISMA Extension for Scoping Reviews (PRISMA-ScR): Checklist and Explanation. Ann Intern Med. 2018;169(7):467-73. https://doi.org/10.7326/M18-0850
    » https://doi.org/10.7326/M18-0850
  • 31 Downes MJ, Brennan ML, Williams HC, Dean RS. Development of a critical appraisal tool to assess the quality of cross-sectional studies (AXIS). BMJ Open. 2016;6(12):e011458. https://doi.org/10.1136/bmjopen-2016-011458
    » https://doi.org/10.1136/bmjopen-2016-011458
  • 32 Aird JC, Millett DT, Sharples K. Fracture of polycarbonate brackets--a related photoelastic stress analysis. Br J Orthod. 1988;15(2):87-92. https://doi.org/10.1179/bjo.15.2.87
    » https://doi.org/10.1179/bjo.15.2.87
  • 33 Badran SA, Orr JF, Stevenson M, Burden DJ. Photo-elastic stress analysis of initial alignment archwires. Eur J Orthod. 2003;25(2):117-25. https://doi.org/10.1093/ejo/25.2.117
    » https://doi.org/10.1093/ejo/25.2.117
  • 34 Clifford PM, Orr JF, Burden DJ. The effects of increasing the reverse curve of Spee in a lower archwire examined using a dynamic photo-elastic gelatine model. Eur J Orthod. 1999;21(3):213-22. https://doi.org/10.1093/ejo/21.3.213
    » https://doi.org/10.1093/ejo/21.3.213
  • 35 Stewart CM, Chaconas SJ, Caputo AA. Effects of intermaxillary elastic traction on orthodontic tooth movement. J Oral Rehabil. 1978;5(2):159-66. https://doi.org/10.1111/j.1365-2842.1978.tb01209.x
    » https://doi.org/10.1111/j.1365-2842.1978.tb01209.x
  • 36 Levy AJ, Chaconas SJ, Caputo AA. Orthopedic effect of the extraoral chin cup appliance on the mandible. Am J Orthod. 1976;69(1):29-41. https://doi.org/10.1016/0002-9416(76)90096-8
    » https://doi.org/10.1016/0002-9416(76)90096-8
  • 37 Lima SMJ, Moraes M, Asprino L. Photoelastic analysis of stress distribution of surgically assisted rapid maxillary expansion with and without separation of the pterygomaxillary suture. J Oral Maxillofac Surg. 2011;69(6):1771-5. https://doi.org/10.1016/j.joms.2010.07.035
    » https://doi.org/10.1016/j.joms.2010.07.035
  • 38 D’Attilio M, Tecco S, Traini T, Spoto G, Festa F. Role of the friction free distalize appliance (2FDA)PAT in the molar distalization: photoelastic analysis and alkaline-phosphatase (ALP) activity on first molar and bicuspid. Int J Immunopathol Pharmacol. 2007;20(1 Suppl 1):61-7. https://doi.org/10.1177/039463200702001s13
    » https://doi.org/10.1177/039463200702001s13
  • 39 Chaconas SJ, Caupto AA, Miyashita K. Force distribution comparisons of various retraction archwires. Angle Orthod. 1989;59(1):25-30. https://doi.org/10.1043/0003-3219(1989)059<0025:FDCOVR>2.0.CO;2
    » https://doi.org/10.1043/0003-3219(1989)059<0025:FDCOVR>2.0.CO;2
  • 40 Meros GC, Gonini AJ, Lopes MB, Paranhos LR, Suzuki SS, Garcez AS. Photoelastic analysis of tension distribution in different orthodontic approaches for closing anterior open bites. Minerva Stomatol. 2019;68(5):265-72. https://doi.org/10.23736/S0026-4970.19.04204-3
    » https://doi.org/10.23736/S0026-4970.19.04204-3
  • 41 Abrão AF, Domingos RG, Paiva JB, Laganá DC, Abrão J. Photoelastic analysis of stress distribution in mandibular second molar roots caused by several uprighting mechanics. Am J Orthod Dentofac Orthop. 2018;153(3):415-21. https://doi.org/10.1016/j.ajodo.2017.07.023
    » https://doi.org/10.1016/j.ajodo.2017.07.023
  • 42 Schwertner A, Almeida RR, Gonini AJ, Almeida MR. Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA). Dental Press J Orthod. 2017;22(1):57-64. https://doi.org/10.1590/2177-6709.22.1.057-064.oar
    » https://doi.org/10.1590/2177-6709.22.1.057-064.oar
  • 43 Çehreli S, Özçırpıcı AA, Yılmaz A. Tilted orthodontic micro implants: a photoelastic stress analysis. Eur J Orthod. 2013;35(5):563-7. https://doi.org/10.1093/ejo/cjr070
    » https://doi.org/10.1093/ejo/cjr070
  • 44 Yoon YJ, Jang SH, Hwang GW, Kim KW. Stress distribution produced by correction of the maxillary second molar in buccal crossbite. Angle Orthod. 2002;72(5):397-401. https://doi.org/10.1043/0003-3219(2002)072<0397:SDPBCO>2.0.CO;2
    » https://doi.org/10.1043/0003-3219(2002)072<0397:SDPBCO>2.0.CO;2
  • 45 Yoon Y-J, Jeong W-J, Jang S-H, Hwang G-W, Kim K-W. Stress distribution produced by the correction of the mandibular second molar in lingual crossbite. Angle Orthod. 2002;72(6):593-8. doi:10.1043/0003-3219(2002)072<0593:SDPBTC>2.0.CO;2
    » https://doi.org/10.1043/0003-3219(2002)072<0593:SDPBTC>2.0.CO;2
  • 46 Shetty V, Caridad JM, Caputo AA, Chaconas SJ. Biomechanical rationale for surgical-orthodontic expansion of the adult maxilla. J Oral Maxillofac Surg. 1994;52(7):741-2. https://doi.org/10.1016/0278-2391(94)90492-8
    » https://doi.org/10.1016/0278-2391(94)90492-8
  • 47 Domingos RG, Lima Júnior A, Laganá DC, Rino Neto J, Abrão J, Paiva JB. Stress distribution analysis in anterior teeth caused by several retraction mechanics. Dental Press J Orthod. 2021;26(5):e212042. https://doi.org/10.1590/2177-6709.26.5.e212042.oar
    » https://doi.org/10.1590/2177-6709.26.5.e212042.oar
  • 48 Nakamura A, Teratani T, Itoh H, Sugawara J, Ishikawa H. Photoelastic stress analysis of mandibular molars moved distally with the skeletal anchorage system. Am J Orthod Dentofac Orthop. 2007;132(5):624-9. https://doi.org/10.1016/j.ajodo.2005.11.041
    » https://doi.org/10.1016/j.ajodo.2005.11.041
  • 49 Kusakabe T, Caputo AA, Shetty V, Iida J. Biomechanical rationale for surgically facilitated expansion of the maxilla in the cleft palate patient. World J Orthod. 2007;8(2):167-73.
  • 50 Matsui S, Caputo AA, Chaconas SJ, Kiyomura H. Center of resistance of anterior arch segment. Am J Orthod Dentofac Orthop. 2000;118(2):171-8. https://doi.org/10.1067/mod.2000.103774
    » https://doi.org/10.1067/mod.2000.103774
  • 51 Oliveira E, Gomes V, Gomide H. Material and technique for flat photoelastic analysis of stress distribution produced by dental implants. Rev Fac Odont Anápolis. 2004;6(1):8-13.
  • 52 Kinni ME, Hokama SN, Caputo AA. Force transfer by osseointegration implant devices. Int J Oral Maxillofac Implants. 1987;2(1):11-4.
  • 53 Guichet DL, Yoshinobu D, Caputo AA. Effect of splinting and interproximal contact tightness on load transfer by implant restorations. J Prosthet Dent. 2002;87(5):528-35. https://doi.org/10.1067/mpr.2002.124589
    » https://doi.org/10.1067/mpr.2002.124589
  • 54 Ferreira Júnior A. Desenvolvimento de um sistema para análise automática do padrão de franjas fotoelásticas isocromáticas [master’s thesis]. São Paulo: University of São Paulo; 2003.
  • 55 Schiavon J. Aplicação da técnica da fotoelasticidade na análise de fundações por estacas helicoidais [master’s thesis]. São Carlos: University of São Paulo; 2010.
  • 56 Laganá D, Zanetti A. Comparative study of the biomechanical behavior of the dental extension removable partial prostheses and the cantilever fixed partial prostheses. Photoelastic analysis of the reaction of supporting structures. RPG Rev Pós-Graduação. 1995;2(2):45-51.

Edited by

  • Assistant editor:
    Luciana Butini Oliveira

Publication Dates

  • Publication in this collection
    27 Oct 2025
  • Date of issue
    2025

History

  • Received
    25 July 2024
  • Reviewed
    28 Nov 2024
  • Accepted
    17 Dec 2024
location_on
Faculdade São Leopoldo Mandic Rua José Rocha Junqueira, 13, CEP: 13045-755 , Tel.: +55 (19) 3211-3689 - Campinas - SP - Brazil
E-mail: contato@revistargo.com.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Reportar erro