Open-access Comparative simulated-data study on the low-energy X-ray shielding performance of micro- and nano-sized Bi2O3-filled PMMA composites

ABSTRACT

This work evaluates micro- and nano-sized bismuth oxide fillers in poly(methyl methacrylate) (PMMA) composites for low-energy X-ray shielding. Eleven material formulations were examined: neat PMMA and PMMA/Bi2O3 composites containing 10, 20, 30, 40, or 50 wt% filler in either micro- or nano-sized form. Seven photon-energy points from 20 to 100 keV and sheet thicknesses of 0.05–1.00 cm were assessed. The composition-based attenuation baseline was obtained from XCOM-style mixture calculations; micro/nano differences were explored only as bounded dispersion, packing, and agglomeration scenarios applied outside XCOM. Under these assumptions, the nano 50 wt% scenario produced a 60 keV radiation protection efficiency of 58.1% at 2 mm, compared with 53.4% for the corresponding micro scenario and 4.1% for neat PMMA. Multi-factor ANOVA showed that thickness, energy, and filler loading dominated the response, with partial eta-squared values of 0.890, 0.785, and 0.713, respectively, whereas the size-class main effect was smaller. The results provide screening hypotheses for formulation selection; they do not constitute experimental evidence that particle size changes intrinsic XCOM coefficients or that the proposed composites outperform certified shielding products.

Keywords:
PMMA/Bi2O3 composite; Low-energy X-ray shielding; Nano-filled polymer; Mass attenuation coefficient; Factorial statistical analysis.

1. INTRODUCTION

Lead-free polymer composites are increasingly studied for diagnostic X-ray shielding because clinical, industrial, and laboratory environments need barriers that are lighter, less toxic, and easier to shape than traditional lead sheets [1,2,3,4,5]. The relevant photon range is dominated by photoelectric absorption and incoherent scattering, so the shielding response is controlled by both chemical composition and mesoscopic filler distribution [6,7,8]. PMMA is attractive in this context because it is transparent, moldable, biocompatible, and already used in medical and engineering components, but its intrinsic attenuation is weak at low photon energies. Incorporating bismuth oxide into PMMA is therefore a rational design strategy, because bismuth has a high atomic number and a K-edge near 90.5 keV, while Bi2O3 can be dispersed as micro- or nano-sized particles without using lead [9,10,11,12].

Particle size is especially relevant when high-Z powders are embedded in a polymer matrix. At identical mass fraction, a well-dispersed nanoparticle population can shorten unfilled polymer pathways, increase interfacial contact area, and reduce local shielding heterogeneity [13,14,15]. A coarse microparticle population can be easier to handle and less costly, but it is also more likely to produce sedimentation, agglomerated domains, and low-density channels if processing is not optimized [5, 16]. These microstructural features do not change the fundamental photon cross sections, yet they can change the effective attenuation observed in a practical sheet [17, 18]. A useful comparison must therefore hold composition constant while varying particle scale, energy, and thickness over a sufficiently broad matrix [2, 3, 19].

The computational basis for photon attenuation is well established. BERGER et al. [6] provide the XCOM database for calculating total attenuation coefficients of elements, compounds, and mixtures, and HUBBELL and SELTZER [7, 20] compiled mass attenuation coefficients for dosimetric materials. WinXCom and reengineered XCOM implementations have further supported reproducible attenuation calculations [17, 18], while Geant4 and MCNP6 illustrate how Monte Carlo transport can be applied to photon-shielding problems [21,22,23,24]. Recent PMMA/Bi2O3 studies provide useful experimental anchors. ALSAAB and ZEGHIB [9] reported on prepared PMMA-Bi2O3 nanocomposites with 10–40 wt% filler, while the same group later examined micro-composites prepared by melt mixing [16]. CAO et al. [10] showed that UV-cured PMMA/Bi2O3 composites with loadings up to 44 wt% improved gamma attenuation, and ASARI SHIK and GHOLAMZADEH [13] reported that nanoparticle-filled EPVC composites attenuated diagnostic X-rays better than comparable microparticle-filled systems.

Despite this literature, a controlled statistical comparison between micro- and nano-sized Bi2O3 distribution scenarios in PMMA under low-energy X-ray conditions remains useful. Diagnostic spectra, lead-free garments, and polymer-shielding reviews all show that composition alone cannot determine barrier suitability [2–5, 19]. Many reports present one or a few compositions, whereas design screening benefits from multiple loadings, energies, thicknesses, repeated stochastic realizations, and an explicit uncertainty model. This computational study therefore compares neat PMMA with ten PMMA/Bi2O3 formulations covering micro- and nano-sized filler scenarios at 10, 20, 30, 40, and 50 wt%. The objective is to quantify how a bounded, explicitly phenomenological particle-distribution assumption changes the composition-based baseline while energy, loading, density, and thickness are varied simultaneously. The resulting micro/nano contrasts are sensitivity results to be tested experimentally, not measured material constants.

2. EXPERIMENTAL AND METHODS

A reproducible computational framework was constructed using a fixed random seed. Eleven material formulations were defined: one neat PMMA control, five micro-Bi2O3/PMMA formulations, and five nano-Bi2O3/PMMA formulations. The seven values 20, 30, 40, 50, 60, 80, and 100 keV are photon-energy points, not a material count. Nominal filler loadings were 10, 20, 30, 40, and 50 wt%. Assigned median diameters of 2.5 µm and 55 nm were scenario descriptors used to label the two distribution cases; they were not inputs to XCOM. Composite density was calculated by the inverse rule of mixtures using 1.18 g cm−3 for PMMA and 8.90 g cm−3 for Bi2O3, followed by a small scenario-based packing correction for void content and agglomeration. The resulting density ranged from 1.18 g cm−3 for neat PMMA to approximately 2.02 g cm−3 for the micro 50 wt% case and 2.05 g cm−3 for the nano 50 wt% case.

Reference mass attenuation coefficients were generated from an unmodified XCOM-style mixture rule using tabulated NIST photon-interaction data [6, 7]. This baseline depends on elemental mass fractions and photon energy; it contains no particle-size, interfacial-area, dispersion, or agglomeration variable. For the separate micro/nano sensitivity comparison, the composition-based baseline was converted to an effective sheet response using the scenario density and a bounded distribution multiplier representing possible changes in void fraction and high-Z pathway continuity. The multiplier was applied outside XCOM and was not treated as a change in atomic cross section. It was deliberately limited to a few percent and was not calibrated against measurements from the present formulations. Accordingly, all reported micro/nano differences are conditional scenario outputs rather than intrinsic attenuation coefficients assigned solely from the nominal particle diameters.

The attenuation calculation used the narrow-beam exponential law I/I0 = exp(−µx), where µ is the scenario linear attenuation coefficient and x is sheet thickness. For each of the eleven formulations, calculations were performed at seven photon-energy points (20, 30, 40, 50, 60, 80, and 100 keV) and five thicknesses (0.05, 0.10, 0.20, 0.50, and 1.00 cm). Five stochastic realizations were generated for every formulation-energy-thickness combination, giving 1925 observations. The outputs were mass and linear attenuation coefficients, transmission, radiation protection efficiency, half-value layer, tenth-value layer, mean free path, and lead-equivalent thickness. Energy-dependent perturbations represented numerical and prospective measurement uncertainty; they were not a substitute for full photon-transport or experimental validation.

Data integrity checks were applied before analysis. The expected Cartesian product was 11 material formulations × 7 photon-energy points × 5 thicknesses × 5 stochastic realizations = 1925 observations. Attenuation coefficients, transmission, and protection efficiency were checked for nonphysical negative values. Calculated values were retained at full precision for the ANOVA, post hoc tests, and response-surface model and were rounded only for manuscript display.

For clarity, the mathematical expressions were kept explicit. The exponential relation links the measurable transmission ratio to material and thickness. The half-value layer was calculated as HVL = ln(2)/µ, the tenth-value layer as TVL = ln(10)/µ, and the mean free path as MFP = 1/µ. Lead-equivalent thickness was calculated by equating the optical thickness of the composite sheet and a lead sheet at the same energy. These expressions are standard in photon attenuation and radiation-protection calculations [2, 6–8, 18, 20].

Statistical analysis was treated as a central component of the study rather than a post hoc supplement. Multi-factor ANOVA was applied to shielding efficiency in the composite samples using size class, loading, energy, and thickness as factors, including the three-way interaction among size class, loading, and energy, following standard factorial-design principles [25]. Pairwise micro-versus-nano comparisons were performed for each loading and energy at 0.20 and 0.50 cm thicknesses using Welch tests with Holm correction, and Cohen’s d quantified effect size [26, 27]. A polynomial response-surface regression then modeled shielding efficiency as a function of a nano indicator, scaled loading, log energy, thickness, quadratic terms, and interactions [28]. Model adequacy was assessed by predicted-observed agreement, residual plots, Shapiro-Wilk testing, Levene testing, adjusted R2, and root-mean-square error.

3. RESULTS AND DISCUSSION

Table 1 summarizes all eleven material formulations. The design includes one neat-PMMA control, five micro-filled formulations, and five nano-filled formulations so that filler loading, size-class scenario, and density can be examined separately. The agglomeration index and dispersion score are assumed scenario variables rather than measured morphology. Density increases monotonically with Bi2O3 loading, from 1.18 g cm−3 for neat PMMA to approximately 2.02–2.05 g cm−3 at 50 wt%. The lower nominal agglomeration index assigned to the nano series represents a favorable-dispersion case conditional on adequate surface treatment and mixing; it is not a general claim that nanoparticles intrinsically agglomerate less.

Table 1
PMMA/Bi2O3 sample matrix.

The sample matrix also clarifies why neat PMMA was retained as a true control rather than being duplicated as both micro and nano at 0 wt%. At zero filler there is no particle-size variable, and forcing the control into both size classes would artificially inflate the degrees of freedom for the ANOVA. The control instead anchors the shielding scale and illustrates how much of the observed gain comes from Bi2O3 itself. The factorial comparison of particle size was then restricted to the 10–50 wt% composites where size class has a physical meaning.

Both particle-size classes can develop nonuniform filler distributions, but by different routes. Micrometer powders may sediment or form coarse domains during casting, whereas nanoparticles have high surface energy and can form strongly bound clusters, especially as loading and viscosity increase. The lower agglomeration indices assigned to the nano cases in Table 1 therefore define a favorable-processing sensitivity scenario, not an experimentally established property of the proposed materials. The nano penalty increases at 50 wt% to acknowledge the difficulty of maintaining nanoscale separation at high solids content. Experimental SEM/TEM mapping, density/porosity measurements, and replicate attenuation tests are required to determine whether this scenario is realized [13–15, 29].

The mass attenuation coefficients in Table 2 follow the expected energy and composition trends. Neat PMMA remained a weak attenuator, with a calculated 60 keV radiation protection efficiency of only 4.1% for a 2 mm sheet. By contrast, PMMA-M50 and PMMA-N50 produced 60 keV efficiencies of 53.4% and 58.1%, respectively, at the same thickness. The improvement was even more pronounced at 40 keV, where the high-Z filler substantially increased the photoelectric interaction probability. This agrees with the physical basis emphasized by KNOLL [8] and with PMMA/Bi2O3 trends reported by CAO et al. [10] and ALSAAB and ZEGHIB [9, 16].

Table 2
Selected attenuation and shielding metrics.

The 40 and 60 keV columns in Table 2 show the expected tradeoff between photon energy, loading, and thickness. The 60 keV value is reported as a standardized design comparison and should not be read as the global energy of maximum attenuation. The 100 keV coefficient rises relative to the 80 keV value because 100 keV lies above the bismuth K absorption edge at 90.5259 keV. This nonmonotonic behavior is a composition-based atomic-interaction effect inherited from the bismuth cross section; it is distinct from the external particle-distribution scenario.

A direct NIST edge check quantifies this effect. The elemental bismuth mass attenuation coefficient is 2.522 cm2 g−1 at 80 keV, falls to 1.856 cm2 g−1 immediately below the K-edge at 90.5259 keV, and jumps to 7.380 cm2 g−1 immediately above the edge, a 3.98-fold discontinuity; it remains 5.739 cm2 g−1 at 100 keV [6, 7]. Because mixture coefficients are mass-weighted, Bi2O3-containing formulations inherit this edge while the magnitude is diluted by the PMMA fraction. Recent Geant4 work on K-edge-optimized PMMA/metal-oxide shields likewise reports sharp post-edge attenuation gains [30]. This edge check is separate from the seven-point factorial dataset and from the particle-distribution multiplier.

Lead-equivalent thickness was included for engineering interpretation rather than as a claim that PMMA/Bi2O3 directly replaces lead in every setting. The PbEq expression equates the optical thickness of the composite and lead, so a 2 mm composite with a given µ is converted into the lead thickness that would give the same monoenergetic attenuation. Lead remains much denser and more compact for many radiation-protection tasks. However, low-Z polymer matrices provide flexibility, reduced toxicity, easier shaping, and better compatibility with complex components, which is why nonlead garments and polymer shields continue to be studied [2–5]. The calculated lead-equivalent values therefore help compare barriers of finite thickness, but they should be interpreted alongside density and processability. A polymer composite may be preferable when conformability and lead avoidance matter more than minimum absolute thickness.

Figure 1 establishes the narrow-beam geometry and computational workflow. A monoenergetic photon beam passes through a PMMA/Bi2O3 sheet, and the transmitted fraction is converted into attenuation metrics. The diagram links material formulation, composition-based attenuation coefficients, bounded distribution scenarios, stochastic realizations, and statistical interpretation. It should not be read as a full Geant4 or MCNP transport model.

Figure 1
Computational workflow and narrow-beam attenuation geometry. The schematic shows the computational workflow used to compare micro- and nano-sized Bi2O3-filled PMMA sheets under monoenergetic low-energy X-ray exposure.

Figure 2 is an input-scenario figure rather than a materials-characterization figure. Figure 2A shows the density assigned across Bi2O3 loadings. Figure 2B displays the assumed loading-dependent agglomeration penalty, and Figure 2C shows the nominal diameter labels used to distinguish the two sensitivity cases. Figure 2D anchors the composition calculation to tabulated PMMA, Bi2O3, and Pb photon-interaction behavior [6, 7, 17, 18, 20]. Figure 2E summarizes the density matrix, and Figure 2F combines the assumed dispersion score and density into the external scenario descriptor. None of the particle-distribution descriptors in Figures 2B, 2C, or 2F is an XCOM input or an experimental microstructural measurement.

Figure 2
Computational formulation and sensitivity-scenario inputs. A, density as a function of Bi2O3 loading; B, assumed loading-dependent agglomeration penalty; C, nominal particle-size labels used for the two scenarios; D, reference PMMA, Bi2O3, and Pb mass attenuation coefficients; E, density matrix by size-class scenario and loading; F, assumed distribution descriptor. Panels B, C, and F are phenomenological inputs and are not supplied by XCOM.

The paired reading of Figures 2A and 2E emphasizes that density converts mass attenuation into the linear attenuation governing transmission through a fixed thickness. Figure 2D shows the separate composition effect: high-Z filler raises the mass attenuation baseline. Figures 2B, 2C, and 2F do not alter tabulated atomic cross sections; they define bounded sensitivity assumptions for packing and filler continuity. This separation is essential because XCOM mixture calculations cannot resolve particle dispersion, interfacial interactions, surface area, agglomeration, or microstructural heterogeneity.

Figure 3 compares the scenario-adjusted coefficients with the unmodified composition-based mixture reference. Figures 3A and 3B retain the governing atomic trend: attenuation decreases from 20 to 80 keV andrises at 100 keV after the bismuth K-edge [6, 7, 17, 18, 20, 30]. At 50 wt%, the scenario values at 100 keV were 3.33 cm2 g−1 for the nano case and 2.96 cm2 g−1 for the micro case. The corresponding nano/micro ratios in Figure 3C are imposed sensitivity outcomes, mostly 1.04–1.12; they are not XCOM predictions of a particle-size-dependent atomic coefficient.

Figure 3
Scenario-adjusted attenuation coefficients and composition-based mixture reference. A, micro-scenario coefficients; B, nano-scenario coefficients; C, scenario nano/micro ratio across loading and energy; D, percent deviation introduced by the external distribution multiplier relative to the unmodified mixture reference. The deviations are sensitivity assumptions, not particle-size terms calculated by XCOM.

Figure 3D separates the composition baseline from the external particle-distribution assumptions. The small negative micro deviation and positive nano deviation reflect the chosen packing/continuity multipliers, not different elemental cross sections. Published experiments show that morphology and density can create measured micro/nano differences in finished composites [13–15, 29, 31], but those studies do not validate the exact multipliers used here. Figure 3D should therefore be read as a bounded sensitivity analysis that defines hypotheses for fabrication and testing.

Bounding the deviation from the mixture rule prevents the scenario term from overwhelming the established photon-interaction physics. However, a small imposed multiplier is not evidence that a real nano-filled sheet will outperform a micro-filled sheet. Actual performance depends on achieved density, porosity, cluster size, spatial uniformity, interface quality, and thickness control. The scenario therefore tests the consequences of a favorable nano distribution within a specified range; it does not establish a universal nanoparticle mechanism.

Figure 4 translates mass attenuation into transmission and radiation protection efficiency by using the expression I/I0 = exp(−µx). Figures 4A and 4B compare 2 mm transmission for micro- and nano-filled sheets, respectively. Both heatmaps show that 40 and 50 wt% composites sharply reduced transmission at 20–60 keV, while the nano heatmap in Figure 4B shows slightly lower transmission at matched loading because of the dispersion gain. The 100 keV column behaves differently from a smooth monotonic energy series because it lies above the bismuth K-edge. This feature is practically important for diagnostic spectra, where spectral filtration and tube voltage can place photon populations around absorption edges [2, 19].

Figure 4
Stochastic narrow-beam transmission and radiation protection efficiency. A, 2 mm transmission heatmap for micro-filled scenarios; B, 2 mm transmission heatmap for nano-filled scenarios; C, thickness-dependent transmission on a logarithmic scale; D, radiation protection efficiency at 2 mm as a function of energy, loading, and size-class scenario.

Figure 4C isolates thickness effects. Because transmission follows an exponential law, the first millimeters of a high-loading composite generated the largest absolute reduction in transmitted photons, a behavior expected from standard attenuation theory [8, 18, 20]. For PMMA-N50 at 60 keV, a 2 mm sheet already produced the high protection efficiency reported in Table 2, while 5 mm and 10 mm sheets moved the result toward near-complete attenuation. Figure 4D then converts the same physics into RPE at a fixed 2 mm thickness, making it easier to compare materials at an engineering-relevant sheet dimension.

The combined reading of Figures 4A, 4B and 4D reveals a threshold-like behavior. Below approximately 20 wt% Bi2O3, the 2 mm sheets improved over neat PMMA but did not create a robust high-efficiency barrier over the full energy range. Between 30 and 40 wt%, the transition becomes more useful, particularly at 20–60 keV, which is consistent with reported high-loading PMMA/Bi2O3 studies [9, 10, 16]. At 50 wt%, the performance gain is large but comes with the highest density and the greatest assumed agglomeration risk. Figure 4C also cautions that additional thickness increases mass, stiffness, and cost, so design should evaluate target attenuation rather than maximize filler and thickness simultaneously [2–5].

Figure 5 reports HVL, TVL, and MFP, which are not redundant with radiation protection efficiency. Figure 5A gives HVL = ln(2)/µ, the thickness needed to halve photon fluence; Figure 5B gives TVL = ln(10)/µ, the thickness needed for a tenfold reduction; and Figure 5C gives MFP = 1/µ, the average interaction length in the material [8, 18, 20]. The smallest calculated 60 keV HVL among the Table 2 materials was 0.158 cm, visible in Figure 5A for the high-loading nano-filled sheet. Figure 5B follows the same ordering at a larger thickness scale, and Figure 5C confirms that the mean interaction length contracts as Bi2O3 loading increases.

Figure 5
Half-value layer, tenth-value layer, and mean free path. A, half-value layer; B, tenth-value layer; C, mean free path. Lower values indicate more compact shielding, with the nano 50 wt% case producing the smallest penetration lengths over most of the low-energy range.

Figure 5A is particularly helpful when comparing materials across geometries. A single RPE value can look impressive if the sheet is thick, but HVL describes the material’s intrinsic compactness at a given photon energy. Figure 5B is more relevant to stringent barrier specifications that require a tenfold reduction, whereas Figure 5C gives the interaction-length interpretation behind both layer metrics. The nano 50 wt% sheet achieved the lowest penetration metrics because it combined high density, high Bi2O3 mass fraction, and a positive dispersion term. However, the micro 50 wt% sheet remained close enough that fabrication considerations could outweigh the small attenuation difference in some applications.

The direct micro-versus-nano comparison is shown in Figure 6. Figure 6A reports the nano-minus-micro RPE difference in percentage points, showing that at 50 wt% loading the nano advantage was 2.61 percentage points at 40 keV and 4.04 percentage points at 60 keV when the 0.20 and 0.50 cm thicknesses were analyzed together. The effect diminished at lower loadings because there was less high-Z material to redistribute, and it also became less dominant where the sheet already approached very high attenuation. This loading-dependent nano advantage is consistent with reports that nanoparticle-filled polymer shields can outperform microparticle analogues most clearly in diagnostic-energy and high-loading regimes [13–15].

Figure 6
Particle-size effect on shielding efficiency. A, nano-minus-micro shielding-efficiency difference in percentage points; B, Cohen’s d effect size for the pairwise particle-size contrast; C, Holm-corrected significance of the nano advantage across loading and energy.

Figures 6B and 6C clarify the difference between practical magnitude and statistical support. Cohen’s d in Figure 6B identifies where the nano advantage is large relative to replicate variance, whereas Figure 6C shows that 34 of the 35 loading-energy pairwise tests remained significant after Holm correction. Some comparisons were statistically significant because replicate variance was low, but the associated percentage-point gain in Figure 6A was modest. For material selection, the strongest cases are those where Figures 6A, 6B and 6C all point in the same direction: a meaningful nano gain, a large effect size, and corrected statistical significance.

The ANOVA results in Table 3 and Figure 7 confirm that the main drivers were loading, energy, and thickness. Figure 7A shows that the partial eta squared values were 0.713 for loading, 0.785 for energy, and 0.890 for thickness. The size-class main effect was statistically detectable with p = 6.23 × 10−9, but its effect size in Figure 7A was smaller than those of the macroscopic design variables. Figure 7B adds the regression-estimate view, showing how loading, energy, thickness, and interactions enter the response-surface model, while Figure 7C counts where the corrected nano advantage appears across loading levels. This is the central statistical conclusion of the study: nano-sized Bi2O3 improves performance at matched loading, yet the engineering design space is controlled first by high-Z mass fraction, photon energy, and sheet thickness.

Table 3
Multi-factor ANOVA summary for shielding efficiency.
Figure 7
Statistical effect structure. A, ANOVA partial eta-squared effect sizes; B, response-surface regression estimates with confidence intervals; C, number of Holm-corrected significant nano wins at each filler loading.

The interaction results in Table 3 require a conservative interpretation. Loading × energy was significant (p < 0.001, partial eta squared = 0.037), confirming that the loading effect changes across the photon-energy grid. In contrast, size × loading (p = 0.811), size × energy (p = 0.999), and size × loading × energy (p = 1.000) were not significant. Thus, the factorial model supports a small overall size-scenario main effect but does not support claims that this effect reliably changes with loading or energy. Any apparent condition-specific nano advantage in pairwise plots should be treated as exploratory and scenario-dependent.

The nonsignificant three-way interaction shows that the present scenario data do not provide statistical evidence that the micro/nano difference depends jointly on loading and photon energy. The descriptive pairwise patterns remain useful for selecting experimental test conditions, but they cannot be elevated to a general interaction mechanism. This finding also reinforces the distinction between precise statistical detection under low stochastic variance and external physical validation of a composite material.

The response-surface regression provided a second, more design-oriented statistical view. Whereas ANOVA treats the tested loadings and energies as categorical factors, the regression approximates how performance changes across a continuous design space. The fitted surface is not intended to extrapolate beyond 10–50 wt% or 20–100 keV, but it is useful within that domain. It permits interpolation between tested compositions, estimates target thicknesses for 75% or 90% attenuation, and highlights regions where the response begins to plateau. This is valuable because practical formulation rarely lands exactly on a tabulated loading, and recent shielding-composite reviews encourage linking radiation metrics with manufacturable design windows rather than reporting only one maximum-loading specimen [1, 3, 5].

Figure 8 converts the statistical model into response surfaces. Figure 8A shows the predicted 2 mm RPE surface for micro-filled PMMA, while Figure 8B shows the corresponding nano-filled surface. At high loading and low energy, both surfaces approach high RPE, but Figure 8B is shifted upward and its 75% and 90% contour lines move to lower loading, especially between 40 and 60 keV. Figure 8C translates this difference into thickness required for 90% attenuation and shows that 50 wt% nano-filled PMMA required less thickness than the micro counterpart at the selected energies. This difference is valuable when the target application is a flexible panel, transparent insert, dental barrier, or lightweight protective component where millimeter-scale thickness matters.

Figure 8
Response-surface prediction and compact-shield design. A, predicted 2 mm shielding-efficiency surface for micro-filled PMMA; B, predicted 2 mm shielding-efficiency surface for nano-filled PMMA; C, model-derived thickness required for 90% attenuation at selected energies.

Figures 8A and 8B also help identify diminishing returns. At low energy and high loading, RPE approaches a plateau because the transmitted fraction is already small. In that region, increasing loading from 40 to 50 wt% may add density and processing difficulty while producing only a small increase in protection. Figure 8C shows the opposite design situation: at higher energy or lower loading, the required thickness remains appreciable, so increased filler loading or nanoscale dispersion can still have practical value. A rational shielding design should therefore define the target spectrum and allowable thickness before selecting filler content.

Figure 9 evaluates whether the response-surface interpretation is statistically defensible. Figure 9A shows that predicted and observed RPE followed the identity line closely, and the response-surface model produced an adjusted R2 of 0.901 with an RMSE of 10.46 percentage points. Figure 9B shows a residual distribution centered near zero, while Figure 9C shows that the Q-Q pattern had only modest tail deviations despite the sensitivity of Shapiro-Wilk testing at large sample size. Figure 9D plots residuals against fitted values and does not show a strong funnel pattern, although Levene testing indicated detectable variance differences between filler classes and justified Welch tests for pairwise comparisons.

Figure 9
Regression diagnostics and model adequacy. A, predicted-observed agreement for shielding efficiency; B, residual distribution; C, normal Q-Q behavior; D, residuals plotted against fitted values to assess systematic model structure.

Residual behavior in Figures 9B and 9D matters because shielding efficiency is bounded between 0 and 100%. Near the upper boundary, random error cannot remain perfectly symmetric because values cannot exceed complete attenuation. Figure 9D shows only modest boundary effects, mainly in high-loading, low-energy cases where RPE was close to saturation. This is acceptable for the present comparative purpose, but a future experimental study with many near-100% observations might benefit from modeling transmission or log transmission directly rather than percentage efficiency.

The statistical treatment avoids relying on a single best-performing formulation. The analysis spans 11 formulations, seven photon-energy points, five thicknesses, and five stochastic realizations, allowing main effects, interactions, pairwise contrasts, and diagnostics to be evaluated within the specified scenario model [25,26,27,28]. That breadth improves internal comparison, but it does not convert repeated calculations into independent experimental specimens. External validation remains necessary for every claim involving actual dispersion, density, mechanical integrity, or attenuation.

Recent experimental literature provides qualitative anchors rather than a direct numerical validation. Prepared PMMA/Bi2O3 systems show that higher Bi2O3 loading increases attenuation [9, 10, 16]. A 2026 PMMA/clay study combined measurements with theoretical calculations [32], while experimental PMMA/WC work compared micro- and nano-filled formulations and demonstrated a tungsten K-edge response [31]. Micro/nano Fe2O3 biocomposites evaluated by experiment and Geant4 [33] and silicone-rubber/metal-oxide composites assessed for morphology, mechanics, and attenuation [29] further show that observed particle-size effects are inseparable from processing, density, and energy. These studies support the direction of the proposed validation plan but do not validate the present scenario coefficients.

Table 4 benchmarks the present scenario against representative polymer, glass, bio-based, and conventional barrier systems. The comparison is deliberately evidence-based rather than a league table: photon spectra, detector geometry, thickness, density, filler chemistry, and reported metrics differ across studies. The bismuth boro-silicate glass study [34], for example, provides experimental/XCOM evidence for Bi2O3-containing transparent shields, but its rigid glass matrix is not directly comparable with PMMA. Accordingly, no cross-study ranking is made from unmatched MAC, LAC, HVL, TVL, MFP, or RPE values.

Table 4
Literature benchmark for PMMA/Bi2O3 scenario results and representative shielding systems.

Practical translation requires a manufacturing route matched to the intended component. Melt compounding followed by compression molding can produce plates or laminated panels, solution casting can support thin laboratory sheets but requires solvent and sedimentation control, and UV curing offers rapid shaping where optical and formulation constraints permit [9, 10, 16]. High-loading personal shielding would also require a flexible carrier, filler encapsulation, surface treatment, closed nanoparticle handling, and testing for particle release, flexural fatigue, aging, and cleaning resistance. Lead remains a compact benchmark, whereas lead-free commercial garments trade attenuation against mass, thickness, flexibility, and spectral dependence [2, 4]. The present calculations do not establish equivalence to a certified lead or lead-free product. Related Matéria studies on barite concrete [35] and boron-doped Cerrobend [36] likewise demonstrate that useful shielding claims combine attenuation with density, thickness, mechanical behavior, application geometry, and measured validation.

The principal limitations are physical rather than statistical. First, the narrow-beam model excludes scattered-photon buildup, secondary radiation, detector response, and realistic broad-beam geometry. Second, XCOM supplies composition-based cross sections and cannot represent nanoparticle dispersion, cluster formation, interfacial interactions, increased surface area, porosity, sedimentation, or spatial heterogeneity. Third, the external particle-distribution multiplier is phenomenological and uncalibrated; the nominal 2.5 µm and 55 nmdiameters only identify scenarios and do not independently justify different intrinsic attenuation coefficients. Fourth, the stochastic realizations characterize within-model uncertainty, not batch-to-batch manufacturing variability.

Calculated coefficients and efficiencies are not substitutes for measured attenuation. A validation campaign should fabricate the 11-formulation matrix or a preregistered subset using controlled melt mixing, solution casting, or UV curing. SEM/TEM or micro-CT mapping should quantify cluster size and spatial uniformity; density, porosity, thickness, and filler mass fraction should be measured for every specimen. Attenuation testing should include calibrated narrow- and broad-beam geometries, multiple independently prepared batches, uncertainty propagation, and comparison with unmodified NIST/XCOM predictions. Mechanical, optical, aging, fatigue, and particle-release tests are also required before plates, panels, or personal protective components can be considered.

A further requirement is spectral validation. Real X-ray tubes emit polyenergetic spectra, and filtration determines how many photons lie below and above the bismuth K-edge. Future work should convolve measured or validated energy-dependent coefficients with representative dental, mammography, fluoroscopy, and industrial spectra, then compare transmitted air kerma or dose rather than relying only on monoenergetic RPE. Measurements bracketing 90.5259 keV are especially important for determining whether the elemental edge advantage remains meaningful after spectral weighting and microstructural losses.

Within these limits, the model can prioritize candidates for testing rather than select a finished material. The 30 wt% nano scenario is a moderate-loading hypothesis, the 50 wt% nano scenario defines the upper attenuation case, and the 40–50 wt% micro scenarios test whether simpler powder handling can provide comparable measured performance. These are conditional screening choices; their ranking may change after real density, dispersion, broad-beam scatter, mechanical integrity, cost, and areal mass are measured.

A focused first experiment could include PMMA-M40, PMMA-N40, and PMMA-N50 together with neat PMMA and a 20 wt% comparator. This subset spans particle-size scenario, high loading, and a lower-loading control while limiting fabrication burden. The primary hypothesis should be whether independently prepared micro and nano batches differ after density, porosity, cluster size, and thickness are measured, rather than whether the nominal particle diameter alone predicts attenuation.

The proposed workflow combines composition-based NIST/XCOM coefficients, narrow-beam transmission calculations, stochastic sensitivity analysis, response-surface mapping, and factorial inference. Its appropriate role is pre-experimental design: identifying formulations, energies, and thicknesses at which measured differences would be most informative. Future extensions should use validated Geant4 or MCNP transport for realistic spectra and scatter, followed by external experimental confirmation and multi-objective analysis of attenuation, mechanics, mass, manufacturability, cost, and durability.

4. CONCLUSION

This computational study compared one neat-PMMA control with ten PMMA/Bi2O3 formulations covering 10–50 wt% filler at seven photon-energy points from 20 to 100 keV. The composition-based results confirm the expected dominant roles of Bi2O3 mass fraction, density, energy, and thickness. The PMMA-N50 scenario produced the largest calculated response within the imposed favorable-dispersion assumptions, including a post-K-edge increase at 100 keV. This scenario ranking is not an experimentally verified particle-size effect.

Factorial analysis, corrected pairwise contrasts, effect-size estimates, response-surface regression, and diagnostics provide a consistent internal description of the modeled design space. Thickness, energy, and loading dominate the response; the size-scenario main effect is smaller. Importantly, the size × loading, size × energy, and three-way interactions are nonsignificant, so the data do not support a reliable loading- or energy-dependent particle-size mechanism. The statistical precision therefore defines testable hypotheses but cannot replace independent batches or measured attenuation.

For a first experimental validation, PMMA-M40, PMMA-N40, and PMMA-N50 could be tested with neat PMMA and a lower-loading comparator under calibrated narrow- and broad-beam conditions. Independent fabrication batches, morphology, density, porosity, thickness metrology, and uncertainty analysis are required to determine whether the assumed distribution contrast exists. Matched mechanical and aging tests should accompany attenuation measurements so that shielding gains are not separated from manufacturability.

The results should be interpreted as a transparent pre-experimental sensitivity study. They do not demonstrate that nominal particle diameter changes XCOM mass attenuation coefficients, that nano-filled PMMA is universally superior to micro-filled PMMA, or that either formulation is equivalent to a certified lead or lead-free commercial shield. The contribution is a statistically organized framework for choosing the most informative formulations and K-edge-relevant energies for experimental testing.

5. DATA AVAILABILITY

The data supporting the findings of this study are available from the corresponding author upon reasonable request.

6. BIBLIOGRAPHY

  • [1] MORE, C.V., ALSAYED, S., BADAWI, M.S., et al., “Polymeric composite materials for radiation shielding: a review”, Environmental Chemistry Letters, v. 19, n. 3, pp. 2057–2090, 2021. doi: https://doi.org/10.1007/s10311-021-01189-9. PubMed PMID: 33558806.
    » https://doi.org/10.1007/s10311-021-01189-9
  • [2] MCCAFFREY, J.P., SHEN, H., DOWNTON, B., et al., “Radiation attenuation by lead and nonlead materials used in radiation shielding garments”, Medical Physics, v. 34, n. 2, pp. 530–537, 2007. doi: https://doi.org/10.1118/1.2426404. PubMed PMID: 17388170.
    » https://doi.org/10.1118/1.2426404
  • [3] LI, R., GU, Y., WANG, Y., et al., “Radiation shielding polymer composites: ray-interaction mechanism, structural design, manufacture and biomedical applications”, Materials & Design, v. 233, pp. 112253, 2023. doi: https://doi.org/10.1016/j.matdes.2023.112253.
    » https://doi.org/10.1016/j.matdes.2023.112253
  • [4] ÇETIN, H., YURT, A., YÜKSEL, S.H., “The absorption properties of lead-free garments for use in radiation protection”, Radiation Protection Dosimetry, v. 173, n. 4, pp. 345, 2017. doi: https://doi.org/10.1093/rpd/ncw004. PubMed PMID: 26884505.
    » https://doi.org/10.1093/rpd/ncw004
  • [5] NAMBIAR, S., YEOW, J.T.W., “Polymer-composite materials for radiation protection”, ACS Applied Materials & Interfaces, v. 4, n. 11, pp. 5717–5726, 2012. doi: https://doi.org/10.1021/am300783d. PubMed PMID: 23009182.
    » https://doi.org/10.1021/am300783d
  • [6] BERGER, M.J., HUBBELL, J.H., SELTZER, S.M., et al., XCOM: photon cross sections database, Gaithersburg, National Institute of Standards and Technology, 2010. doi: https://doi.org/10.18434/T48G6X.
    » https://doi.org/10.18434/T48G6X
  • [7] HUBBELL, J.H., SELTZER, S.M., Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest, Gaithersburg, National Institute of Standards and Technology, 1995.
  • [8] KNOLL, G.F., Radiation detection and measurement, 4 ed., Hoboken, John Wiley & Sons, 2010.
  • [9] ALSAAB, A.H., ZEGHIB, S., “Study of prepared lead-free polymer nanocomposites for X- and gamma- ray shielding in healthcare applications”, Polymers, v. 15, n. 9, pp. 2142, 2023. doi: https://doi.org/10.3390/polym15092142. PubMed PMID: 37177287.
    » https://doi.org/10.3390/polym15092142
  • [10] CAO, D., YANG, G., BOURHAM, M., et al., “Gamma radiation shielding properties of poly(methyl methacrylate)/Bi2O3 composites”, Nuclear Engineering and Technology, v. 52, n. 11, pp. 2613–2619, 2020. doi: https://doi.org/10.1016/j.net.2020.04.026.
    » https://doi.org/10.1016/j.net.2020.04.026
  • [11] ALSHAHRI, S., ALSUHYBANI, M., ALOSIME, E., et al., “LDPE/Bismuth oxide nanocomposite: Preparation, characterization and application in X-ray shielding”, Polymers, v. 13, n. 18, pp. 3081, 2021. doi: https://doi.org/10.3390/polym13183081. PubMed PMID: 34577982.
    » https://doi.org/10.3390/polym13183081
  • [12] AMBIKA, M.R., NAGAIAH, N., HARISH, V., et al., “Preparation and characterization of isophthalic-Bi2O3 polymer composite gamma radiation shields”, Radiation Physics and Chemistry, v. 130, pp. 351–358, 2017. doi: https://doi.org/10.1016/j.radphyschem.2016.09.022.
    » https://doi.org/10.1016/j.radphyschem.2016.09.022
  • [13] ASARI SHIK, N., GHOLAMZADEH, L., “X-ray shielding performance of the EPVC composites with micro- or nanoparticles of WO3, PbO or Bi2O3”, Applied Radiation and Isotopes, v. 139, pp. 61–65, 2018. doi: https://doi.org/10.1016/j.apradiso.2018.03.025. PubMed PMID: 29723694.
    » https://doi.org/10.1016/j.apradiso.2018.03.025
  • [14] AZMAN, N.Z., SIDDIQUI, S.A., LOW, I.M., “Characterisation of micro-sized and nano-sized tungsten oxide-epoxy composites for radiation shielding of diagnostic X-rays”, Materials Science and Engineering C, v. 33, n. 8, pp. 4952–4957, 2013. doi: https://doi.org/10.1016/j.msec.2013.08.023. PubMed PMID: 24094209.
    » https://doi.org/10.1016/j.msec.2013.08.023
  • [15] KARABUL, Y., ICELLI, O., “The assessment of usage of epoxy based micro and nano-structured composites enriched with Bi2O3 and WO3 particles for radiation shielding”, Results in Physics, v. 26, pp. 104423, 2021. doi: https://doi.org/10.1016/j.rinp.2021.104423.
    » https://doi.org/10.1016/j.rinp.2021.104423
  • [16] ALSAAB, A.H., ZEGHIB, S., “Analysis of X-ray and gamma ray shielding performance of prepared polymer micro-composites”, Journal of Radiation Research and Applied Sciences, v. 16, n. 4, pp. 100708, 2023. doi: https://doi.org/10.1016/j.jrras.2023.100708.
    » https://doi.org/10.1016/j.jrras.2023.100708
  • [17] GERWARD, L., GUILBERT, N., JENSEN, K.B., et al., “X-ray absorption in matter. Reengineering XCOM”, Radiation Physics and Chemistry, v. 60, n. 1–2, pp. 23–24, 2001. doi: https://doi.org/10.1016/S0969-806X(00)00324-8.
    » https://doi.org/10.1016/S0969-806X(00)00324-8
  • [18] GERWARD, L., GUILBERT, N., BJØRN JENSEN, K., et al., “WinXCom a program for calculating X-ray attenuation coefficients”, Radiation Physics and Chemistry, v. 71, n. 3–4, pp. 653–654, 2004. doi: https://doi.org/10.1016/j.radphyschem.2004.04.040.
    » https://doi.org/10.1016/j.radphyschem.2004.04.040
  • [19] BOONE, J.M., SEIBERT, J.A., “An accurate method for computer-generating tungsten anode X-ray spectra from 30 to 140 kV”, Medical Physics, v. 24, n. 11, pp. 1661–1670, 1997. doi: https://doi.org/10.1118/1.597953. PubMed PMID: 9394272.
    » https://doi.org/10.1118/1.597953
  • [20] HUBBELL, J.H., “Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV”, The International Journal of Applied Radiation and Isotopes, v. 33, n. 11, pp. 1269–1290, 1982. doi: https://doi.org/10.1016/0020-708X(82)90248-4.
    » https://doi.org/10.1016/0020-708X(82)90248-4
  • [21] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION., “The 2007 recommendations of the International Commission on Radiological Protection”, Annals of the ICRP, v. 37, n. 2–4, pp. 1–332, 2007. PubMed PMID: 18082557.
  • [22] AGOSTINELLI, S., ALLISON, J., AMAKO, K., et al., “Geant4 a simulation toolkit”, Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, v. 506, n. 3, pp. 250–303, 2003. doi: https://doi.org/10.1016/S0168-9002(03)01368-8.
    » https://doi.org/10.1016/S0168-9002(03)01368-8
  • [23] ALLISON, J., AMAKO, K., APOSTOLAKIS, J., et al., “Recent developments in Geant4”, Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, v. 835, pp. 186–225, 2016. doi: https://doi.org/10.1016/j.nima.2016.06.125.
    » https://doi.org/10.1016/j.nima.2016.06.125
  • [24] GOORLEY, T., JAMES, M., BOOTH, T., et al., “Initial MCNP6 release overview”, Nuclear Technology, v. 180, n. 3, pp. 298–315, 2012. doi: https://doi.org/10.13182/NT11-135.
    » https://doi.org/10.13182/NT11-135
  • [25] MONTGOMERY, D.C., Design and analysis of experiments, 10 ed., Hoboken, John Wiley & Sons, 2019.
  • [26] COHEN, J., Statistical power analysis for the behavioral sciences, 2 ed., Hillsdale, Lawrence Erlbaum Associates, 1988.
  • [27] HOLM, S., “A simple sequentially rejective multiple test procedure”, Scandinavian Journal of Statistics, Theory and Applications, v. 6, n. 2, pp. 65–70, 1979.
  • [28] BOX, G.E.P., DRAPER, N.R., Response surfaces, mixtures, and ridge analyses, 2 ed., Hoboken, John Wiley & Sons, 2007. doi: https://doi.org/10.1002/0470072768.
    » https://doi.org/10.1002/0470072768
  • [29] EL-KHATIB, A.M., ZARD, K., ABBAS, M.I., et al., “Novel composite based on silicone rubber and a nano mixture of SnO2, Bi2O3, and CdO for gamma radiation protection”, Scientific Reports, v. 14, n. 1, pp. 1578, 2024. doi: https://doi.org/10.1038/s41598-024-51965-0. PubMed PMID: 38238486.
    » https://doi.org/10.1038/s41598-024-51965-0
  • [30] ALABSY, M.T., EL-KALIUOBY, M.I., EL-KHATIB, A.M., et al., “K-edge optimization of PMMA-based metal oxide shields for dental X-ray protection using Geant4 Monte Carlo simulations”, Radiation and Environmental Biophysics, v. 65, n. 3, pp. 831–845, 2026. doi: https://doi.org/10.1007/s00411-026-01226-7. PubMed PMID: 42301299.
    » https://doi.org/10.1007/s00411-026-01226-7
  • [31] EL-KHATIB, A.M., ALABSY, M.T., EL-KHATIB, A.Y., et al., “Superiority of micro/nano tungsten carbide reinforced poly-methyl methacrylate composites in shielding gamma radiation”, Nuclear Engineering and Technology, v. 56, n. 10, pp. 4103–4114, 2024. doi: https://doi.org/10.1016/j.net.2024.05.013.
    » https://doi.org/10.1016/j.net.2024.05.013
  • [32] ALABSY, M.T., EL-KHATIB, A.M., ABBAS, M.I., et al., “Radiation shielding parameters of poly-methyl methacrylate reinforced with different types of clays: experimental and theoretical study”, Nuclear Instruments & Methods in Physics Research. Section B, Beam Interactions with Materials and Atoms, v. 577, pp. 166159, 2026. doi: https://doi.org/10.1016/j.nimb.2026.166159.
    » https://doi.org/10.1016/j.nimb.2026.166159
  • [33] EL-KHATIB, A.M., ALABSY, M.T., SHARABY, M.A., et al., “Eco-friendly gamma radiation protection using waste rice straw and animal glue enhanced by micro and nano iron oxide: a Geant4 simulation and experimental study”, Physica Scripta, v. 100, n. 2, pp. 025303, 2025. doi: https://doi.org/10.1088/1402-4896/ada212.
    » https://doi.org/10.1088/1402-4896/ada212
  • [34] DOMA, A.S., ABBAS, M.I., KASHYOUT, A.E.H.B., et al., “Impact of Bi2O3 on prepared nano (SiO2-Na2O-CaO-B2O3) glass as radiation shielding material”, Scientific Reports, v. 14, n. 1, pp. 17980, 2024. doi: https://doi.org/10.1038/s41598-024-67363-5. PubMed PMID: 39097656.
    » https://doi.org/10.1038/s41598-024-67363-5
  • [35] PIRES, M.M., NASCIMENTO, C.D., SOUZA, E.G., et al., “A radiation shielding study for radiotherapy rooms: an application for barium concrete”, Matéria, v. 27, n. 2, e202248962, 2022. doi: https://doi.org/10.1590/1517-7076-rmat-2022-48962.
    » https://doi.org/10.1590/1517-7076-rmat-2022-48962
  • [36] ŞAHIN, M.C., MANISA, K., BIRCAN, H., et al., “Experimental, theoretical, and biological investigations on radiation shielding parameters of boron-doped Cerrobend alloys”, Matéria, v. 29, n. 4, e20240366, 2024. doi: https://doi.org/10.1590/1517-7076-rmat-2024-0366.
    » https://doi.org/10.1590/1517-7076-rmat-2024-0366

Corresponding Author:

Chen Junhao, 24121396@shu.edu.cn

Publication Dates

  • Publication in this collection
    26 Oct 2026
  • Date of issue
    2026

History

  • Received
    24 June 2026
  • Accepted
    27 Aug 2026
location_on
Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiro, em cooperação com a Associação Brasileira do Hidrogênio, ABH2 Av. Moniz Aragão, 207, 21941-594, Rio de Janeiro, RJ, Brasil, Tel: +55 (21) 3938-8791 - Rio de Janeiro - RJ - Brazil
E-mail: revmateria@gmail.com