Open-access Objective and subjective visual outcome comparison analysis of two diffractive presbyopic correcting intraocular lenses

Análise comparativa dos resultados visuais objetivos e subjetivos de duas lentes intraoculares difrativas para correção da presbiopia

ABSTRACT

This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus range between −1.50 D and −3.00 D. Despite these differences, patient satisfaction levels were comparable between groups, with photic phenomena reported at similar frequencies. These findings highlight the importance of individualized intraocular lens selection based on each patient's visual needs.

Keywords:
Cataract extraction; Lenses, intraocular; Presbyopia; Treatment outcome

RESUMO

Esta série de casos avalia os resultados visuais de duas lentes intraoculares trifocais, ZFR00V e TNFT00, em pacientes submetidos à cirurgia de catarata. Dezenove pacientes (38 olhos) receberam implantes bilaterais de uma das duas lentes intraoculares. As avaliações pós-operatórias incluíram acuidade visual não corrigida e corrigida para longe, intermediária e perto, além da satisfação do paciente e a ocorrência de fenômenos fotopsias. Ambas as lentes intraoculares proporcionaram desempenho visual satisfatório para visão de longe e intermediária. No entanto, a LIO ZFR00V demonstrou melhor desempenho na visão de perto, especialmente na faixa de desfocalização entre −1,50 D e −3,00 D. Apesar dessas diferenças, os níveis de satisfação dos pacientes foram semelhantes entre os grupos, com fenômenos fotopsias relatados em frequências comparáveis. Esses achados ressaltam a importância da seleção individualizada da lente intraocular com base nas necessidades visuais de cada paciente.

Descritores:
Cirurgia de catarata; Lentes intraoculares; Presbiopia; Resultado do tratamento

INTRODUCTION

Cataract surgery has evolved beyond restoring visual clarity to become a refractive procedure to achieve spectacle independence. Advances in intraocular lens (IOL) technology, particularly trifocal diffractive designs, enable better performance across near, intermediate, and distance vision. However, these advancements have potential drawbacks, including visual disturbances such as halos and glare. A deeper understanding of the performance characteristics of these lenses is essential for guiding clinical decision-making and optimizing patient outcomes.(1-4)

The ZFR00V (Tecnis Synergy, Johnson & Johnson) and TNFT00 (Acrysof Panoptix, Alcon) are widely used trifocal IOLs, each employing unique optical designs. The ZFR00V lens integrates advanced chromatic aberration correction to improve contrast sensitivity and depth of focus(6). The TNFT00 lens features a non-apodized trifocal design aimed at distributing light energy efficiently across three focal points: near, intermediate, and distance. Both lenses have demonstrated high levels of spectacle independence and patient satisfaction in controlled clinical settings.(5-10)

This case series compares these lenses’ objective and subjective outcomes in a real-world clinical setting. It focuses on visual acuity at various distances, defocus curve analysis, and patient-reported quality of life. The findings provide valuable insights for clinicians who customize IOL selection to individual patient needs.

All patients included in this study gave informed consent. Because this case series included more than three patients, Institutional Review Board (IRB) approval was granted. The study adhered to the tenets of the Declaration of Helsinki. Ethics approval and consent to participate: all patients signed informed consent. The study was approved by the Ethics Committee of the Hospital Oftalmológico de Brasilia (76675320.6.0000.5667)

CASE REPORTS

Nineteen patients (38 eyes) underwent bilateral implantation of either the ZFR00V or TNFT00 IOL, meeting strict inclusion criteria: bilateral cataracts, no significant ocular comorbidities, and high preoperative visual potential. Cases involving prior refractive surgery or postoperative refractive errors were excluded. All surgeries were performed by the same experienced surgeon following a standardized protocol.

Visual and subjective outcomes

Objective visual outcomes revealed excellent distance and intermediate vision performance for both lenses. Notably, the ZFR00V lens demonstrated a clear advantage in near-vision tasks. Uncorrected near visual acuity (UNVA) at 40 cm averaged 0.10 logMAR in the ZFR00V group, significantly outperforming the TNFT00 group, which achieved a mean of 0.15 logMAR (p < 0.05)11. Intermediate and distance visual acuities were statistically comparable, highlighting the robustness of both IOLs in these domains.

Monocular defocus curve analysis reinforced the superior near-vision capabilities of the ZFR00V lens. Between defocus levels of −1.50 D and −3.00 D, the ZFR00V consistently outperformed the TNFT00, providing sharper vision for near tasks. This difference was statistically significant, with effect sizes indicating moderate clinical relevance.(Figure 1)

Figure 1
Defocus monocular curve in the dominant eye.

Subjective measures corroborated these findings. Approximately 88% of patients in the ZFR00V group reported being "very satisfied" with their outcomes, compared to 91% in the TNFT00 group. Despite the ZFR00V lens's superior near performance, overall satisfaction levels were similar, reflecting the high quality of both lenses. Commonly reported photic phenomena, including halos and glare, were mild to moderate and did not significantly impact patient satisfaction.

Statistical analysis showed a moderate effect size for the ZFR00V's advantage in the near vision (Cohen's d = 0.5). No significant differences were observed in distance or intermediate visual acuities(18). Photic phenomena were statistically comparable, suggesting these effects are characteristic of trifocal designs rather than specific lenses. Tables 1-4 summarize the IOL's results.

Table 1
Postoperative binocular assessment for UDVA in both groups
Table 2
Visual acuity and vision disturbances in both groups after surgery
Table 3
Monocular defocus curve in the dominant eye
Table 4
Halos and glare in both groups

DISCUSSION

Recently, new presbyopia IOLs have been introduced to improve postoperative outcomes following cataract surgery. Our findings suggest that the two lenses studied can achieve good postoperative distance, intermediate, and near objective and subjective outcomes. Objectively, the defocus curve exhibited similar performance for both IOLs, except in the myopic defocus, where the ZFR00V IOL was superior. Additionally, there was a trend for better performance of the ZFR00V IOL at near and intermediate distances.

Although most studies analyze monocular visual acuities, we decided to report binocular near and intermediate vision to mimic real-life conditions. In this study, previous studies evaluated the refractive outcomes of several trifocal IOLs, including the ZFR00V and TNFT00. Similarly to our study, they did not find statistically significant differences between groups in distance, near, and intermediate visual acuities. However, it was also noted that the ZFR00V tended to provide a broader functional range of focus, which may be advantageous for patients engaged in activities that require flexible focus at varying distances.(8)

The analysis shows that the ZFR00V IOL demonstrated consistent postoperative visual acuity, particularly at near distances. The ZFR00V group exhibited a mean UDVA of 0.0375 logMAR with a standard deviation of 0.0496, indicating stable distance vision. The mean values of UNVA at 30 cm and 40 cm were consistent at 0.1 logMAR with no variability (standard deviation [SD] = 0), underscoring reliable near vision. The UIVA at 60 cm presented a mean of 0.1625 logMAR with an SD of 0.0625, suggesting slight variability but overall satisfactory intermediate vision. While both IOLs offered good visual outcomes, the data did not indicate a statistically significant advantage for the TNFT00 IOL regarding UDVA or uncorrected intermediate visual acuity (UIVA). As initially mentioned, it did not explicitly show a flatter defocus curve in the distance and intermediate regions. Instead, the findings reflect that both lenses have their strengths, with ZFR00V providing a more continuous near vision and TNFT00 maintaining effective intermediate and distance performance.(4,10-14)

Defocus curves offer a graphical representation of visual acuity across different focus levels, allowing assessment of how effectively IOLs provide clear vision at various distances. Studies by Moshirfar et al.(4,11) and Dick et al.(15) determined superior visual acuity with the ZFR00V IOL compared to the TNFT00 IOL at near distance, particularly at the −3.5 D and −4.0 D defocus but determined improved distance and intermediate vision with the TNFT00 IOL. Other studies showed the superiority of the TNFT00 compared to other trifocal IOLs; this study's defocus curves are comparable to those previously published but did not show the superiority of one IOL over the other, except in the myopic defocus curves for the ZFR00V IOL.(2,3,6-9,11-19) The clinical results obtained in our defocus curve for the ZFR00V lens were also compatible with previous studies on the same lens, demonstrating good continuous UDVA, UNVA, and UIVA.(4,10,11,18-27)

Our study also demonstrated a better visual performance between the −1.5 and the −3.0D defocus obtained using the dominant eye, suggesting improved vision with the ZFR00V IOL at intermediate and near distances. However, assessment of near and intermediate binocular vision (a normal condition in real life) showed no statistical difference, suggesting that these results may not represent a real-world setting. Our study also indicates that ZFR00V provides enhanced near-visual acuity and a broader defocus curve for closer distances, making it advantageous for patients prioritizing near vision. Although both IOLs showed good intermediate and distance vision, no significant statistical advantage was observed for the TNFT00 lens in early postoperative assessments.

Despite dysphotopsias, most patients in our study were still willing to undergo surgery again with the same IOL, likely because of good visual acuity at all distances and increased spectacle independence. In fact, for most of our patients, these symptoms did not significantly interfere with daily activities, which resulted in an improved quality of life (QoL). Therefore, IOL selection should consider not only each patient's specific visual needs but also one's tolerance for potential night-time visual disturbance.(4,10,11,14-16)

Furthermore, postoperative visual satisfaction depended on uncorrected VA at all distances and the lens's appropriateness for each patient's lifestyle and daily activities. The final assessment of each patient may involve influencing factors, such as the expectation of surgical results, type of professional occupation, daily routine activities, and patient's personality or critical sense. We observed that more patients in the TNFT00 group were satisfied and willing to undergo surgery again, suggesting that this IOL would suit a broader range of patients.

Subjective postoperative satisfaction was assessed, but no direct comparison with preoperative UCVA was made.

The study's limitations include the small sample size since it is a case series and binocular visual acuity measurements. Although one may find it difficult to draw conclusions from a small study, we did observe some superiority of the ZFR00V IOL on the monocular defocus curve. Additionally, we aimed to reproduce a real-life setting in which patients use both eyes. We might have seen more differences between these IOLs had we included a larger sample size.

In conclusion, when assessed binocularly, ZFR00V and TNFT00 IOLs offer comparable visual outcomes for far, near, and intermediate distances. This study demonstrated the advantage of the ZFR00V in the monocular defocus curve for near vision.

Value statement

What was known
  • Trifocal IOLs provide spectacle independence by enhancing vision at near, intermediate, and distance ranges.

  • The ZFR00V and TNFT00 IOLs have different optical designs, each aiming to optimize visual performance across varying distances.

  • Prior studies suggested that ZFR00V may offer better near vision, while TNFT00 may provide superior intermediate vision.

What this paper adds
  • A real-world comparison of ZFR00V and TNFT00 IOLs in a clinical setting, analyzing both objective and subjective outcomes.

  • There is evidence that the ZFR00V IOL provides superior near vision in the monocular defocus curve, while both lenses offer similar binocular performance.

  • Confirmation that photic phenomena are common in both lenses but do not significantly affect patient satisfaction, emphasizing the importance of patient-specific IOL selection.

DECLARATIONS

This paper has been uploaded to Research Square as a preprint: https://www.researchsquare.com/article/rs-4293746/v1’

Data availability statement:

The data that support the findings of this study are not openly available and are available from the corresponding author upon reasonable request.

Institution:

Hospital Oftalmológico de Brasília, Brasília, DF, Brazil.

Financial support:

no financial support for this work.

REFERENCES

  • 1 Sahbaz I. Importance of Multifocal Intraocular Lenses in The Elderly Population. J Ophthalmol Res. 2020;3:8-15.
  • 2 Sudhir RR, Dey A, Bhattacharrya S, Bahulayan A. AcrySof IQ PanOptix intraocular lens versus extended depth of focus intraocular lens and trifocal intraocular lens: a clinical overview. Asia Pac J Ophthalmol (Phila). 2019;8(4):335-349.
  • 3 Kohnen T, Herzog M, Hemkeppler E, Schönbrunn S, De Lorenzo N, Petermann K, et al. Visual performance of a quadrifocal (Trifocal) intraocular lens following removal of the crystalline lens. Am J Ophthalmol. 2017;184:52-62.
  • 4 Moshirfar M, Stoakes IM, Theis JS, Porter KB, Santos JM, Martheswaran T, Payne CJ, Hoopes PC. Assessing visual outcomes: a comparative study of us-fda premarket approval data for multifocal and EDOF lens implants in cataract surgery. J Clin Med. 2023;12(13):4365.
  • 5 Lapid-Gortzak R, Bhatt U, Sanchez JG, Guarro M, Hida WT, Bala C, et al. Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results. J Cataract Refract Surg. 2020;46(11):1534-42.
  • 6 Sieburth R, Chen M. Intraocular lens correction of presbyopia. Taiwan J Ophthalmol. 2019;9(1):4-17.
  • 7 Böhm M, Petermann K, Hemkeppler E, Kohnen T. Defocus curves of 4 presbyopia-correcting IOL designs: Diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus. J Cataract Refract Surg. 2019;45(11):1625-36.
  • 8 Ferreira TB, Ribeiro FJ, Silva D, Matos AC, Gaspar S, Almeida S. Comparison of refractive and visual outcomes of 3 presbyopia-correcting intraocular lenses. J Cataract Refract Surg. 2022;48(3):280-7.
  • 9 Serdiuk V, Ustymenko S, Fokina S, Ivantsov I. Comparison of three different presbyopia-correcting intraocular lenses. Rom J Ophthalmol. 2020;64(4):364-79.
  • 10 Ozturkmen C, Kesim C, Karadeniz PG, Sahin A. Visual acuity, defocus curve and patient satisfaction of a new hybrid EDOF-multifocal diffractive intraocular lens. Eur J Ophthalmol. 2022;32(5):2988-93.
  • 11 Moshirfar M, Stapley SR, Corbin WM, Bundogji N, Conley M, Darquea IM, et al. Comparative visual outcome analysis of a diffractive multifocal intraocular lens and a new diffractive multifocal lens with extended depth of focus. J Clin Med. 2022;11(24):7374.
  • 12 Palomino-Bautista C, Sánchez-Jean R, Carmona-Gonzalez D, Piñero DP, Molina-Martín A. Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS. Sci Rep. 2021;11(1):12081.
  • 13 Yan W, Łabuz G, Khoramnia R, Auffarth GU. Trifocal intraocular lens selection: predicting visual function from optical quality measurements. J Refract Surg. 2023;39(2):111-8.
  • 14 Łabuz G, Yan W, Baur ID, Khoramnia R, Auffarth GU. Comparison of five presbyopia-correcting intraocular lenses: optical-bench assessment with visual-quality simulation. J Clin Med. 2023;12(7):2523.
  • 15 Dick HB, Ang RE, Corbett D, Hoffmann P, Tetz M, Villarrubia A, et al. Comparison of 3-month visual outcomes of a new multifocal intraocular lens vs a trifocal intraocular lens. J Cataract Refract Surg. 2022;48(11):1270-6.
  • 16 Hida WT, Moscovici BK, Cortez CM, Colombo-Barboza GN, Tzelikis PF, Motta AF, et al. Comparison of visual outcomes of bilateral dual-technology diffractive intraocular lens vs blended enhanced monofocal with dual-technology intraocular lens. J Cataract Refract Surg. 2024;50(4):401-6.
  • 17 Labiris G, Panagis C, Ntonti P, Konstantinidis A, Bakirtzis M. Mix-and-match vs bilateral trifocal and bilateral EDOF intraocular lens implantation: the spline curve battle. J Cataract Refract Surg. 2024;50(2):167-73.
  • 18 Chang DH, Hu JG, Lehmann RP, Thompson VM, Tsai LH, Thomas EK. Clinical performance of a hybrid presbyopia-correcting intraocular lens in patients undergoing cataract surgery in a multicenter trial. J Cataract Refract Surg. 2023;49(8):840-7.
  • 19 Khoramnia R, Baur ID, Łabuz G, Köppe MK, Hallak MK, Auffarth GU. Functional outcomes after bilateral refractive lens exchange with a continuous-range-of-vision intraocular lens. J Cataract Refract Surg. 2023;49(10):1011-7.
  • 20 Hida WT, Vilar C, Moscovici BK, Motta AFP, Carricondo PC. A New Methodology for Evaluating the Potential Impact of Residual Refractive Astigmatism in Pseudophakic Patients. Clin Ophthalmol. 2024;18:1909-14.
  • 21 Cruz JC, Moreno CB, Soares PV, Moscovici BK, Colombo-Barboza GN, Colombo-Barboza LR, et al. Comparison of endothelial cell loss in diabetic patients after conventional phacoemulsification and femtosecond laser-assisted cataract surgery. BMC Ophthalmol. 2023;23(1):181.
  • 22 Rodrigues PF, Moscovici BK, Lamazales L, Freitas MM, Gomes JA, Nosé W, et al. Measurement of the visual axis through two different methods: quantification and differences for measuring chord μ. Arq Bras Oftalmol. 2023;87(4):e2022-0035.
  • 23 de Miranda AP, Silva CB, Mimica LM, Moscovici BK, Malavazzi GR, Hida RY. In vitro antimicrobial analysis of aqueous humor after topical application of moxifloxacin hydrochloride 0.5%. J Cataract Refract Surg. 2015;41(1):135-9.
  • 24 Campos PT, Hida WT, Moscovici BK, Gouvea L, Newald MA, Lake JC, et al. Comparison of tolerance to induced astigmatism in pseudophakic eyes implanted with dual-technology diffractive IOL and enhanced monofocal IOL. Indian J Ophthalmol. 2025;73(9):1302-6.
  • 25 De Melo IR, Hida WT, Moscovici BK, Vilar C, Motta AF, de Medeiros AL, et al. Validation of clinical protocol of astigmatism induction in pseudophakic patients. Clin Ophthalmol. 2024;18:3375-87.
  • 26 Bergamasco VD, Dos Santos VR, Moscovici BK, Campos M. New Device for the correction of aphakia without capsular support. Curr Eye Res. 2024 Oct;49(10):1068-73.
  • 27 Antunes VA, Rosatelli Neto JM, Moscovici BK, Rabelo DF, Sano VA, Hida RY. Automated capsular decompression to avoid Argentinian Flag Sign in intumescent cataract. Clin Ophthalmol. 2024;18:1915-20.

Corresponding author:

Bernardo Kaplan Moscovici Rua Cayowwa, 854, apto. 82 – Perdizes Zip code: 05018001 – São Paulo, SP, Brazil. E-mail: bernardokaplan@yahoo.com.br

Conflict of interest:

no conflict of interest.

Associate Editor:

Tiago Bisol Pontifícia Universidade Católica do Rio de Janeiro, Rio de Janeiro, RJ, Brazil https://orcid.org/0000-0002-7801-8070

Publication Dates

  • Publication in this collection
    15 Dec 2025
  • Date of issue
    2025

History

  • Received
    13 Mar 2025
  • Accepted
    16 Oct 2025
location_on
Sociedade Brasileira de Oftalmologia Rua São Salvador, 107 , 22231-170 Rio de Janeiro - RJ - Brasil, Tel.: (55 21) 3235-9220, Fax: (55 21) 2205-2240 - Rio de Janeiro - RJ - Brazil
E-mail: rbo@sboportal.org.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo