Open-access Peripheral nerve regeneration using a biodegradable conduit from açaí (Euterpe oleracea): a bio-based alternative to autografts

ABSTRACT

Purpose:  To evaluate the regenerative efficacy of an experimental biodegradable nerve conduit composed of polycaprolactone and açaí-derived polyurethane, used for peripheral nerve repair, in comparison with different reconstructive techniques.

Methods:  Wistar rats (n = 48) were allocated into six groups (n = 8): normality (NG), denervated (DG), burial (BG), nerve autograft (NAG), açaí-based neurotube (ANG), and vein autograft (VAG). Sciatic functional index, electrophysiological parameters, and histomorphometry were assessed after 12 weeks.

Results:  NAG and ANG showed significant functional recovery, with ANG being the only group to demonstrate progressive improvement (p = 0.009). Electrophysiological analysis revealed higher amplitude and lower latency in NAG, followed by ANG and VAG. Histomorphometric analysis showed increased axonal density in ANG and NAG compared to non-reconstructed groups (p = 0.004 and p = 0.007, respectively).

Conclusion:  The polycaprolactone/açaí-based conduit demonstrated regenerative performance comparable to autologous nerve grafts.

Key words
Peripheral Nerve Injuries; Autografts; Models, Animal

Introduction

Peripheral nerve injuries showed a considerable clinical challenge, frequently resulting in functional deficits and diminished quality of life1. While peripheral nerves possess an inherent capacity for regeneration, this process is constrained in cases of extensive gaps or intricate lesions2. Autologous nerve grafting is still considered the gold standard for bridging these defects3,4. Despite being the current gold standard, this technique is associated with several complications, including the potential for donor site morbidity, neuroma formation, sensory loss, and limited graft availability5–7.

To address these limitations, biological and synthetic nerve conduits have been proposed as alternatives8. The utilization of conduits offers several advantages, including the avoidance of complications arising from the donor site and the capacity for structural customization9. Several biomaterials, including collagen-based tubes, chitosan scaffolds, and polycaprolactone conduits, have demonstrated efficacy in repairing peripheral nerve gaps of up to 3 cm in preclinical and limited clinical studies, although results in larger gaps remain suboptimal without adjuncts such as growth factors or stem cells10,11. Consequently, the quest for conduits that are biocompatible, porous, flexible, and biodegradable remains a focal point in nerve regeneration research12.

Recent advances in biomaterials research have identified natural sources, such as the Amazonian açaí (Euterpe oleracea Mart.), as promising candidates for biomedical applications. Polymeric derivatives obtained from its seeds have shown potential for developing biodegradable scaffolds with adequate porosity, mechanical stability, and structural integrity, making them suitable for supporting axonal growth and peripheral nerve repair13. Based on these properties, this study aimed to evaluate the feasibility and effectiveness of an açaí-derived bioconduit as a bio-based alternative to autologous nerve grafts in peripheral nerve injury repair.

Methods

The study followed Brazilian legislation on animal experimentation (Law no. 11,794/08), based on National Institutes of Health guidelines and in compliance with the Council for International Organizations of Medical Sciences ethical code and ARRIVE guidelines. The protocol (approval number 16/2024) was approved by the Animal Use and Care Committee of the Universidade do Estado do Pará.

Forty-eight female Wistar rats (3 months, 200–300 g) were housed under controlled conditions. Room temperature was maintained at 22 ± 2°C, relative humidity at 50–60%, and animals were exposed to a 12-hour light/dark cycle (lights on at 7 a.m.) with controlled noise levels at the Experimental Surgery Laboratory, with food and water provided ad libitum. Animals were kept in non-sterile polyurethane cages (three or four per cage) with sterile wood shavings and no environmental enrichment.

The animals were randomly allocated into six groups (n = 8/group). Each rat was assigned a numerical code, and group allocation was determined through a computer-generated random sequence created in BioEstat version 5.4, ensuring unbiased distribution among experimental groups:

  • Normality group (NG): simulated surgery without nerve injury;

  • Denervated group (DG): the sciatic nerve was surgically exposed and sectioned in its middle portion, resulting in a 10-mm nerve gap without reconstruction;

  • Burial group (BG): the proximal nerve stump was buried in adjacent muscle tissue after transection;

  • Nerve autograft group (NAG): a 10-mm segment of the sciatic nerve was resected and immediately reimplanted in its original anatomical orientation using two simple 10-0 nylon epineural sutures at each stump;

  • Açaí-based neurotube group (ANG): a 10-mm nerve gap was created and bridged using a 13-mm biodegradable neurotube composed of açaí-based polymer. The conduit was interposed between the proximal and distal stumps and fixed with two 10-0 nylon epineural sutures per side (Fig. 1);

  • Vein autograft group (VAG): similarly, after the creation of a 10-mm nerve gap, an 11-mm segment of autologous external jugular vein was harvested through a lateral cervical incision, ligated at both ends, and interposed between the stumps. The vein graft was secured with two 10-0 nylon epineural sutures at each end (Fig. 2).

Figure 1
Implantation of the biodegradable neurotube in the sciatic nerve after a 10-mm gap and neurorrhaphy. The conduit was positioned between the proximal and distal nerve stumps and sutured with 10-0 nylon.
Figure 2
Surgical procedure of autologous vein graft interposition in the sciatic nerve. The external jugular vein was harvested and used to bridge a 10-mm nerve gap, fixed with 10-0 nylon epineural sutures.

Fabrication of the nerve conduit

The nerve conduit was fabricated from a blend of polycaprolactone (PCL) and bio-based polyurethane (PU) derived from E. oleracea Mart. (açaí) seed polyol, selected for their biocompatibility, biodegradability, and mechanical suitability. PCL was solubilized in dichloromethane and combined with PU synthesized via a two-step reaction using hexamethylene diisocyanate. The mixture underwent rotary spinning at 3,450 rpm, generating fibrous, porous structures wrapped around 0.6-mm catheters to form 2–3 cm tubular scaffolds. Porosity (60–80%) and pore size (20–30 µm) were controlled to mimic the extracellular matrix and promote axonal growth and vascularization.

Physicochemical and mechanical characterization

The conduit was characterized for water absorption, density, porosity, and compressive strength. Water uptake was calculated by comparing sample masses before and after 24-hour immersion in distilled water at 22°C. Apparent density was determined using a calibrated pycnometer. Porosity was quantified via ethanol displacement. Mechanical properties were assessed by compressive testing (ASTM D695-96), applying 40% deformation to 6 × 3-mm cylindrical specimens. The addition of PU enhanced flexibility and mechanical resilience, supporting structural integrity during nerve regeneration.

All surgical procedures were carried out by a single microsurgeon with over 25 years of experience, utilizing a magnified video system14. Anesthesia was induced with intraperitoneal ketamine (70 mg/kg) and xylazine (10 mg/kg)15. After antisepsis of the right thigh, a posterolateral longitudinal incision was made, exposing the sciatic nerve and its branches (common fibular, tibial, sural) at the popliteal fossa.

In all animals, the aponeurotic layer was sutured with 5-0 nylon sutures, and the skin with continuous 6-0 nylon sutures. Lactated Ringer’s solution (5 mL/kg intravenously, via the lateral tail vein using a 26-gauge catheter) was administered postoperatively. No antibiotics or anticoagulants were used. The duration of the surgical procedure was meticulously documented.

Motor function was assessed at four, eight, and 12 weeks postoperatively using the sciatic functional index, based on hind paw print analysis after inkpad walking across an 8.7 × 43-cm track16.

Electrophysiological recordings of the tibial and common peroneal nerves were obtained at 12 weeks post-surgery under anesthesia, in accordance with the standardized protocol of Somensi et al.17.

After electroneuromyography, animals were euthanized via an intraperitoneal overdose of ketamine (500 mg/kg) combined with xylazine (300 mg/kg), in accordance with institutional guidelines and international recommendations for animal research ethics. The right gastrocnemius muscle was carefully dissected and immediately weighed using a calibrated precision scale. The wet muscle mass was recorded in milligrams. Distal segments of the sciatic nerve were fixed in 10% buffered formalin for 24 hours, dehydrated in graded ethanol, cleared in xylene, sectioned at 4 µm, and stained with hematoxylin and eosin. Axonal density was analyzed in 10 randomly selected fields at 400× magnification under light microscopy (Fig. 3).

Figure 3
Histological analysis of distal sciatic nerve regeneration across experimental groups. Hematoxylin and eosin staining, 400x magnification. Black arrows indicate axons surrounded by Schwann cells.

Statistical analysis was performed using BioEstat 5. Data normality was assessed with the Shapiro-Wilk test, followed by one-way analysis of variance (ANOVA) for group comparisons. A significance level of p < 0.05 was adopted. A sample size of eight animals per group was defined based on an estimated effect size (f = 1.33), considering a 20-point difference in SFI, standard deviation of 15, α = 0.05, and power > 80%. This ensured sufficient sensitivity for detecting intergroup differences.

Results

All animals completed the experimental protocol without incident or need for replacement, and no mortality was observed.

Baseline analysis confirmed group homogeneity in body weight (p = 0.0064), ensuring balanced distribution. Muscle mass was significantly greater in the NG group (0.57 ± 0.12 g; p < 0.001), whereas DG (0.14 ± 0.10 g) and BG (0.16 ± 0.03 g) showed marked muscle atrophy. Reconstruction groups—NAG, ANG, and VAG—demonstrated partial preservation of muscle trophism, with no significant differences among them (Table 1).

Table 1
Descriptive analysis of body weight and gastrocnemius muscle preservation across groups * .

Functional recovery: sciatic nerve functional index

SFI analysis revealed marked functional deficits in the early postoperative period, particularly in BG (-81.54 ± 9.55) and DG (-75.76 ± 8.32), both significantly lower than NG (-18.60 ± 7.76). The NAG group showed progressive improvement, reaching -66.34 ± 12.74 by the third month. Notably, ANG exhibited significant functional recovery between the first and third months (p = 0.009), indicating continuous regenerative activity. VAG demonstrated modest improvement (-70.04 ± 10.22 at month 3), but this difference was not statistically significant compared with DG or BG (p = 0.057), suggesting only a trend toward inferior functional outcomes relative to other reconstruction strategies (Table 2).

Table 2
Sciatic Functional Index progression over three months in experimental groups.

Statistical analysis (paired t-test for intragroup comparisons and ANOVA with Tukey’s post-hoc test) showed that only the ANG group demonstrated statistically significant improvement between the first and third postoperative months (p = 0.009). Intragroup comparisons for DG (p = 0.089), BG (p = 0.077), NAG (p = 0.066), and VAG (p = 0.057) did not reach statistical significance. At the second and third months, NAG, DG, and VAG were statistically similar, whereas ANG was the only group with significantly better scores than DG and BG (p = 0.01). No differences were found between DG and BG (p > 0.05).

Electrophysiological analysis

Electrical conduction through the common peroneal nerve was detected only in the reconstructed groups (Tables 3 and 4). The NAG group showed the lowest latency (1.57 ± 0.28 ms) and the highest amplitude (11.08 ± 8.79 mV), with statistically significant differences compared to ANG (2.35 ± 1.06 ms; 7.91 ± 5.52 mV, p = 0.010) and VAG (2.39 ± 0.73 ms; 5.68 ± 2.94 mV, p = 0.018). No significant differences were observed between ANG and VAG.

Table 3
Electrophysiological latency (ms) of the common peroneal and tibial nerves across experimental groups * .
Table 4
Amplitude of stimulus response in the common peroneal and tibial nerves of experimental groups (mV).

The NAG group demonstrated superior performance (latency = 1.35 ± 0.22 ms; amplitude = 15.35 ± 8.50 mV) compared to VAG (2.18 ± 0.86 ms; 3.93 ± 2.41 mV) and ANG (1.42 ± 0.43 ms; 10.24 ± 9.21 mV), with p < 0.01. However, no significant differences were found between NAG and the other reconstructive groups in pairwise comparisons.

No measurable electrical activity was recorded in the DG and BG groups for either nerve.

Amplitude: one-way analysis of variance with Tukey’s post-hoc test

Regarding the common peroneal nerve, NG showed significantly higher amplitude than all other groups. NAG and ANG showed higher amplitudes compared to VAG and BG. No significant differences were detected among reconstructed groups (NAG versus ANG, p = 0.412; ANG versus VAG, p = 0.354; NAG versus VAG, p = 0.278).

About the tibial nerve, NG differed significantly from all other groups. NAG and ANG showed higher amplitudes compared to VAG and BG (p = 0.027 and p = 0.034, respectively). NAG showed higher amplitude than VAG (p = 0.041), while no significant differences were observed between ANG and VAG (p = 0.296) or between ANG and NAG (p = 0.237).

Histomorphometric analysis showed significantly higher axonal density in the NG group (53.2 ± 7.1; p < 0.001). In contrast, DG (8.00 ± 2.1) and BG (7.11 ± 2.1) exhibited markedly reduced axon counts, consistent with regenerative failure (Table 5). Reconstruction groups—NAG (28.1 ± 7.0), ANG (22.2 ± 6.2), and VAG (18.1 ± 5.3) demonstrated significantly higher axonal density than non-reconstructed groups (p < 0.05), with no significant differences among themselves.

Table 5
Myelinated axon count in the distal sciatic nerve by experimental group.

Discussion

This study evaluated an açaí-based biodegradable neurotube and compared it to established methods. Peripheral nerve injuries accompanied by segmental loss pose a significant challenge, particularly when the primary suture is not viable18–20. Although autologous grafting is widely regarded as the gold standard, its inherent limitations have prompted the exploration of alternative solutions.

No mortality or morbidity was observed in any of the experimental groups during the evaluation period. As expected, the autograft groups did not exhibit compatibility-related issues, given that the graft tissue originated from the same organism. The açaí-based neurotube, being the only non-autologous material tested, did not induce systemic toxicity or overt adverse effects, and its biocompatibility was supported by functional, electrophysiological, and histological findings approaching those of autografts in this early-stage model.

Conducted previously, the extant studies6,21–23 have reported an absence of adverse systemic effects with polymer conduits, even in critical defects. This finding underscores the notion that the structure and manufacturing process directly influence the biological response to the implant24–26. In the case of the açaí-conduit, its porous and biomimetic architecture promotes tissue integration without inducing an exacerbated inflammatory response18,19.

However, it is important to note that the present study did not evaluate the in-vivo degradation profile of the conduit. Although the polymeric blend of polycaprolactone and açaí-based polyurethane was selected based on prior biocompatibility and mechanical testing, the timeline of scaffold resorption, nature of biodegradation byproducts, and their interaction with surrounding tissues remain unexplored. Future investigations should address these parameters to clarify the long-term performance and translational viability of the material in clinical scenarios. Consequently, the integration of bioactive materials with adapted manufacturing methodologies can yield an effective regenerative milieu without compromising animal welfare.

Regarding the preservation of muscle mass, while all the operated groups exhibited significant atrophy of the gastrocnemius relative to the NG, the ANG group showed better muscle preservation than DG and VG, and slightly more than AG, though not statistically significant. Previous studies have demonstrated that the integrity of muscle mass serves as a metric for the effectiveness of motor reinnervation, with factors such as the type of conduit, the time of assessment, the animal species, and the extent of nerve damage contributing to this effectiveness12,18,20.

Only the ANG group showed significant SFI improvement over time, indicating progressive axonal regeneration between the initial and third months, suggesting that the neurotube possessed the capacity to facilitate progressive axonal regeneration and enable functional reconnection with the motor plates. This recovery pattern is consistent with the findings observed in studies of chitosan and collagen-based conduits, which have demonstrated the capacity to enhance gait patterns and preserve locomotor functions in rats with critical sciatic nerve defects21. In addition, several studies have demonstrated that biomaterials with porous microarchitecture and bioactive properties not only favor axonal growth but also facilitate integration with adjacent muscle tissue, thereby reducing atrophy and functional deficit20,22,23.

Despite the prevalence and acceptance of venous grafts due to their biocompatibility, their effectiveness can be hindered when utilized without the inside-out technique. This technique exposes the adventitial layer, which is abundant in trophic factors and promotes the migration of Schwann cells23. In this study, the VG group exhibited suboptimal performance with respect to functional and morphological outcomes, a phenomenon that may be associated with the absence of this technical strategy.

Electrophysiological evaluation demonstrated that ANG and AG had superior electrophysiological responses than DG and VG, supporting effective reconduction that the açaí neurotube facilitated functional electrical reconduction. These findings underscore the notion that meticulously designed conduits can nearly reach the benchmark of autografts, particularly when exhibiting anisotropic organization, compatible mechanical strength, and cell support capacity24. Conductive polymer conduits, such as polycaprolactone, chitosan, and analogous biodegradable polymers, have demonstrated a progressive enhancement in electrophysiological parameters, even in lesions with substantial gaps, as reported in previous studies25.

Histomorphometric analysis revealed that AG and ANG exhibited significantly higher axon densities compared to DG and VG, with no statistical difference observed between the two groups. Although lower than the normal group, the number of regenerated axons in the ANG group was consistent with results observed in models with autologous grafts or conduits enriched with stem cells and growth factor26. These findings suggest that the Amazonian neurotube possesses the capacity to facilitate targeted axonal regeneration, even in the absence of additional biological enrichment.

Additionally, only female Wistar rats were used in this study. This choice was based on standardized protocols and prior institutional experience indicating greater procedural consistency and lower rates of territorial aggression among females, which improves reproducibility and animal welfare. Notably, previous studies have demonstrated that female rats may exhibit enhanced regenerative responses following peripheral nerve injury, including increased axonal elongation and accelerated sensory recovery27. Nonetheless, future investigations including both sexes are essential to assess potential sex-related biological differences.

The study presents two main methodological limitations. The 12-week follow-up period may have been insufficient to evaluate late regenerative events, such as functional myelination and neuromuscular reorganization. Furthermore, the absence of immunohistochemical analysis limits insights into cellular mechanisms such as Schwann cell migration and angiogenesis. Immunomarkers like NF-200 and S100 may enhance future analyses of the evaluation of axonal maturation and vascular support, representing a relevant focus for early-phase future investigations28.

These findings highlight the potential of the açaí-based neurotube as a bioengineered alternative for nerve repair. However, additional long-term and mechanistic studies are warranted to confirm its safety and clinical applicability.

Conclusion

The açaí-based neurotube supports peripheral nerve regeneration, showing functional, electrophysiological, and histological outcomes comparable to autografts, without adverse effects.

Acknowledgements

Not applicable.

Research performed at Laboratory of Experimental Surgery, Universidade do Estado do Pará, Belém (PA), Brazil.

Funding

Not applicable.

Data availability statement

The data will be available upon request.

References

  • 1 Arthur-Farraj P, Coleman MP. Lessons from injury: how nerve injury studies reveal basic biological mechanisms and therapeutic opportunities for peripheral nerve diseases. Neurotherapeutics. 2021;18(4):2200–22. https://doi.org/10.1007/s13311-021-01125-3
    » https://doi.org/10.1007/s13311-021-01125-3
  • 2 Ray WZ, Mackinnon SE. Management of nerve gaps: autografts, allografts, nerve transfers, and end-to-side neurorrhaphy. Exp Neurol. 2010;223(1):77–85. https://doi.org/10.1016/j.expneurol.2009.03.031
    » https://doi.org/10.1016/j.expneurol.2009.03.031
  • 3 Kaplan B, Levenberg S. The role of biomaterials in peripheral nerve and spinal cord injury: a review. Int J Mol Sci. 2022;23(3):1244. https://doi.org/10.3390/ijms23031244
    » https://doi.org/10.3390/ijms23031244
  • 4 Braga-Silva J, Becker AS, Leal BLM, Busnello CV. Advances of direct peripheral nerve repair techniques: do we already have enough scientific evidence? Indian J Orthop. 2022;57(1):189–202. https://doi.org/10.1007/s43465-022-00791-5
    » https://doi.org/10.1007/s43465-022-00791-5
  • 5 Zou X, Dong Y, Alhaskawi A, Zhou H, Ezzi SHA, Kota VG, Abdulla MHAH, Abdalbary SA, Lu H, Wang C. Techniques and graft materials for repairing peripheral nerve defects. Front Neurol. 2024;14:1307883. https://doi.org/10.3389/fneur.2023.1307883
    » https://doi.org/10.3389/fneur.2023.1307883
  • 6 Patel NP, Lyon KA, Huang JH. An update–tissue engineered nerve grafts for the repair of peripheral nerve injuries. Neural Regen Res. 2018;13(5):764–74. https://doi.org/10.4103/1673-5374.232458
    » https://doi.org/10.4103/1673-5374.232458
  • 7 Contreras E, Traserra S, Bolívar S, Forés J, Jose-Cunilleras E, García F, Delgado-Martínez I, Holmgren S, Strehl R, Udina E, Navarro X. Repair of long nerve defects with a new decellularized nerve graft in rats and in sheep. Cells. 2022;11(24):4074. https://doi.org/10.3390/cells11244074
    » https://doi.org/10.3390/cells11244074
  • 8 Safa B, Jain S, Desai MJ, Greenberg JA, Niacaris TR, Nydick JA, Leversedge FJ, Megee DM, Zoldos J, Rinker BD, McKee DM, MacKay BJ, Ingari JV, Nesti LJ, Cho M, Valerio IL, Kao DS, El-Sheikh Y, Weber RV, Shores JT, Styron JF, Thayer WP, Przylecki WH, Hoyen HA, Buncke GM. Peripheral nerve repair throughout the body with processed nerve allografts: Results from a large multicenter study. Microsurgery. 2020;40(5):527–37. https://doi.org/10.1002/micr.30574
    » https://doi.org/10.1002/micr.30574
  • 9 Matsuyama T, Mackay M, Midha R. Peripheral nerve repair and grafting techniques: a review. Neurol Med Chir (Tokyo). 2000;40(4):187–99. https://doi.org/10.2176/nmc.40.187
    » https://doi.org/10.2176/nmc.40.187
  • 10 Liao M, Cui Q, Hu Y, Xing J, Wu D, Zheng S, Zhao Y, Yu Y, Sun J, Chai R. Recent advances in the application of MXenes for neural tissue engineering and regeneration. Neural Regen Res. 2024;19(2):258–63. https://doi.org/10.4103/1673-5374.379037
    » https://doi.org/10.4103/1673-5374.379037
  • 11 Lu Q, Zhang F, Cheng W, Gao X, Ding Z, Zhang X, Lu Q, Kaplan DL. Nerve guidance conduits with hierarchical anisotropic architecture for peripheral nerve regeneration. Adv Healthc Mater. 2021;10(14):e2100427. https://doi.org/10.1002/adhm.202100427
    » https://doi.org/10.1002/adhm.202100427
  • 12 Smaniotto PH, Camargo CP, Kubrusly MS, Gemperli R. Comparison of three different strategies to treat sciatic nerve regeneration: an experimental study. Acta Cir Bras. 2022;37(5):e370501. https://doi.org/10.1590/acb370501
    » https://doi.org/10.1590/acb370501
  • 13 Valério A, Araújo PHH, Sayer C. Preparation of poly(urethane-urea) nanoparticles containing açaí oil by miniemulsion polymerization. Polímeros. 2013;23(4):451–5. https://doi.org/10.4322/polimeros.2013.088
    » https://doi.org/10.4322/polimeros.2013.088
  • 14 Barros RSM, Santos DRD, Teixeira RKC, Araújo NP, Somensi DN, Candido AA. Anatomorphometry of the brachial plexus under high-definition system: an experimental study in rats. Acta Cir Bras. 2022;37(2):e370206. https://doi.org/10.1590/acb370206
    » https://doi.org/10.1590/acb370206
  • 15 Santos DRD, Teixeira RKC, Araújo NP, Calvo FC, Duarte TB, Ataíde LAP, Chaves RHF, Barros RSM. A new anesthetic protocol to medullary nerve roots access in rats. Acta Cir Bras. 2021;36(9):e360908. https://doi.org/10.1590/ACB360908
    » https://doi.org/10.1590/ACB360908
  • 16 Teixeira RKC, Calvo FC, Santos DRD, Araújo NP, Tramontin DF, Costa LVPD, Barros RSM. Criteria for assessing peripheral nerve injury. Behavioral and functional assessment in non-operated Wistar rats. Acta Cir Bras. 2020;35(7):e202000702. https://doi.org/10.1590/s0102-865020200070000002
    » https://doi.org/10.1590/s0102-865020200070000002
  • 17 Somensi DN, Teixeira RKC, Feijó DH, Loureiro KD, Valente AL, Carvalho LTF, Calvo FC, Santos DRD, Barros RSM. Does the type of electrode affect the electromyoneurographic parameters in rats? Acta Cir Bras. 2019;34(3):e201900304. https://doi.org/10.1590/s0102-865020190030000004
    » https://doi.org/10.1590/s0102-865020190030000004
  • 18 Gabriel LP, Santos ME, Jardini AL, Bastos GN, Dias CG, Webster TJ, Maciel Filho R. Bio-based polyurethane for tissue engineering applications: How hydroxyapatite nanoparticles influence the structure, thermal and biological behavior of polyurethane composites. Nanomedicine. 2017;13(1):201–8. https://doi.org/10.1016/j.nano.2016.09.008
    » https://doi.org/10.1016/j.nano.2016.09.008
  • 19 Jahangirian H, Azizi S, Rafiee-Moghaddam R, Baratvand B, Webster TJ. Status of plant protein-based green scaffolds for regenerative medicine applications. Biomolecules. 2019;9(10):619. https://doi.org/10.3390/biom9100619
    » https://doi.org/10.3390/biom9100619
  • 20 Mohammadi J, Delaviz H, Mohammadi B, Delaviz H, Rad P. Comparison of repair of peripheral nerve transection in predegenerated muscle with and without a vein graft. BMC Neurol. 2016;16(1):237. https://doi.org/10.1186/s12883-016-0768-z
    » https://doi.org/10.1186/s12883-016-0768-z
  • 21 Crosio A, Fornasari BE, Gambarotta G, Geuna S, Raimondo S, Battiston B, Tos P, Ronchi G. Chitosan tubes enriched with fresh skeletal muscle fibers for delayed repair of peripheral nerve defects. Neural Regen Res. 2019;14(6):1079–84. https://doi.org/10.4103/1673-5374.250628
    » https://doi.org/10.4103/1673-5374.250628
  • 22 Mahalmani V, Sinha S, Prakash A, Medhi B. Translational research: Bridging the gap between preclinical and clinical research. Indian J Pharmacol. 2022;54(6):393–6. https://doi.org/10.4103/ijp.ijp_860_22
    » https://doi.org/10.4103/ijp.ijp_860_22
  • 23 Zhu Y, Peng N, Wang J, Jin Z, Zhu L, Wang Y, Chen S, Hu Y, Zhang T, Song Q, Xie F, Yan L, Li Y, Xiao J, Li X, Jiang B, Peng J, Wang Y, Luo Y. Peripheral nerve defects repaired with autogenous vein grafts filled with platelet-rich plasma and active nerve microtissues and evaluated by novel multimodal ultrasound techniques. Biomater Res. 2022;26(1):24. https://doi.org/10.1186/s40824-022-00264-8
    » https://doi.org/10.1186/s40824-022-00264-8
  • 24 Leibig N, Boyle V, Kraus D, Stark GB, Penna V. Il10 and poly-dl-lactide-ɛ-caprolactone conduits in critical size nerve defect bridging-An experimental study. Microsurgery. 2016;36(5):410–6. https://doi.org/10.1002/micr.22423
    » https://doi.org/10.1002/micr.22423
  • 25 Bosch-Queralt M, Fledrich R, Stassart RM. Schwann cell functions in peripheral nerve development and repair. Neurobiol Dis. 2023;176:105952. https://doi.org/10.1016/j.nbd.2022.105952
    » https://doi.org/10.1016/j.nbd.2022.105952
  • 26 Liu B, Alimi OA, Wang Y, Kong Y, Kuss M, Krishnan MA, Hu G, Xiao Y, Dong J, DiMaio DJ, Duan B. Differentiated mesenchymal stem cells-derived exosomes immobilized in decellularized sciatic nerve hydrogels for peripheral nerve repair. J Control Release. 2024;368:24–41. https://doi.org/10.1016/j.jconrel.2024.02.019
    » https://doi.org/10.1016/j.jconrel.2024.02.019
  • 27 Kovacic U, Zele T, Osredkar J, Sketelj J, Bajrović FF. Sex-related differences in the regeneration of sensory axons and recovery of nociception after peripheral nerve crush in the rat. Exp Neurol. 2004;189(1):94–104. https://doi.org/10.1016/j.expneurol.2004.05.015
    » https://doi.org/10.1016/j.expneurol.2004.05.015
  • 28 Li R, Li D, Wu C, Ye L, Wu Y, Yuan Y, Yang S, Xie L, Mao Y, Jiang T, Li Y, Wang J, Zhang H, Li X, Xiao J. Nerve growth factor activates autophagy in Schwann cells to enhance myelin debris clearance and to expedite nerve regeneration. Theranostics. 2020;10(4):1649–77. https://doi.org/10.7150/thno.40919
    » https://doi.org/10.7150/thno.40919

*

Corresponding author: deivid_ramos45@hotmail.com

Section editor:

Conflict of interest

Nothing to declare.

Publication Dates

  • Publication in this collection
    10 Nov 2025
  • Date of issue
    2025

History

  • Received
    31 May 2025
  • Accepted
    01 Sept 2025
location_on
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia https://actacirbras.com.br/ - São Paulo - SP - Brazil
E-mail: actacirbras@gmail.com
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top