Open-access Normothermic machine perfusion versus static cold storage for liver transplantation: a systematic review and meta-analysis

ABSTRACT

Purpose:  To compare the effectiveness of normothermic machine perfusion (NMP) with static cold storage (SCS) in preserving transplantable livers, focusing on early postoperative complications.

Methods:  A PRISMA 2020–compliant search of PubMed, Embase, Scopus, Cochrane Library and Web of Science identified comparative studies of NMP versus SCS. Five studies met the criteria (two randomized controlled trials, and three observational cohorts; 630 recipients). Random-effects meta-analysis was performed in RStudio, reporting risk ratio (RR), 95% confidence interval (95%CI), p-value and heterogeneity (I2).

Results:  NMP significantly lowered the incidence of composite early postoperative complications versus SCS (RR = 0.60; 95%CI 0.47–0.75; p < 0.0001), corresponding to a 40% relative risk reduction. Between-study heterogeneity was negligible (I2 = 0 %). Subgroup analyses revealed no significant effect modification by study design (p = 0.75), donation after circulatory death proportion (p = 0.91), preservation duration (p = 0.51), donor age (p = 0.59) or perfusion technique (p = 0.37).

Conclusion:  NMP demonstrates clinically superior graft preservation compared with SCS, consistently reducing early complications after liver transplantation. Adoption of NMP may expand the use of marginal organs and improve post-transplant outcomes.

Key words
Liver Transplantation; Organ Preservation; Perfusion; Reperfusion Injury

Introduction

Liver transplantation remains the definitive treatment for end-stage liver disease. Nevertheless, the persistent scarcity of suitable grafts restricts its wider application. Static cold storage (SCS) is the historical preservation standard, yet it fails to avert ischemia-reperfusion injury—particularly in marginal grafts—, thereby contributing to early allograft dysfunction and ischemic‐type biliary lesions1,2.

Over the past decade, normothermic machine perfusion (NMP) has emerged as a promising strategy to overcome these limitations by maintaining the liver in a metabolically active state ex vivo. Randomized trials and real-world series demonstrate that NMP lowers hepatocellular injury markers, early graft dysfunction and ischemic cholangiopathy when compared with SCS, especially for extended-criteria donors and donation after circulatory death (DCD) grafts3-8.

Nonetheless, several NMP aspects remain under investigation, including optimal perfusion duration, the impact of combined or sequential strategies and the influence of perfusion parameters (oxygen tension and perfusate composition) on mitochondrial function9-13. Experimental data reveal that delayed processing of biopsies after NMP—under hypothermic conditions exceeding four hours—impairs assessment of mitochondrial respiration, underscoring the need for standardized viability protocols14.

Finally, cost-effectiveness and logistic feasibility are pivotal for widespread adoption. Although NMP entails higher upfront expenditure, economic modelling suggests that its incorporation may be justified owing to reduced graft discard rates and improved long-term outcomes—considerations highly relevant to contemporary transplant practice15.

Methods

Eligibility criteria

Randomized controlled trials (RCTs) and observational cohorts comparing NMP with SCS in adult liver transplantation were eligible. Pre-clinical studies, case series, single-case reports and narrative reviews were excluded.

Information sources and search strategy

A comprehensive search of MEDLINE, Embase, Scopus and Web of Science (inception to January 4, 2025) was performed. Reference lists of relevant systematic reviews were screened manually for additional records.

Study selection

All records were imported into reference-management software. Two reviewers independently screened titles/abstracts and full texts; disagreements were resolved by consensus or third-party adjudication (Fig. 1).

Figure 1
PRISMA flow diagram.

Data extraction

Two reviewers independently extracted study characteristics, participant details, interventions, and outcomes. Corresponding authors were contacted for clarification or missing data when required.

Risk-of-bias assessment

RCTs were appraised with Cochrane RoB 2.0, and observational studies with ROBINS-I. Discrepancies were resolved by discussion.

Data synthesis and statistical analysis

Dichotomous outcomes were pooled using the Mantel–Haenszel method under a random-effects model. Heterogeneity was quantified via I2 and τ2. Pre-specified subgroup analyses and meta-regressions explored potential effect modifiers. Two-sided p < 0.05 denoted statistical significance. Analyses were conducted in R 4.2.2 (metafor package).

Results

Overall characteristics and pooled analysis

Five studies encompassing 630 recipients (318 NMP, 312 SCS) met the inclusion criteria. NMP reduced adverse events by ≈ 40 % (risk ratio [RR] = 0.60; 95% confidence interval [95%CI] 0.47–0.75; p < 0.0001) (Fig. 2 and Table 1).

Table 1
Characteristics of the included studies.
Figure 2
Forest plot of the primary meta-analysis.

Heterogeneity was negligible (I2 = 0%; τ2 = 0), indicating a consistent treatment effect.

Subgroup analyses

Effect estimates were comparable between RCTs and observational cohorts, albeit with wider confidence intervals for cohorts. Continuous meta-regression identified no significant influence of DCD proportion, preservation time, donor age, NMP modality (in-transit versus back-to-base) or proportion of chronic indications (Table 2 and Fig. 3).

Figure 3
Bubble plots illustrating meta-regressions.
Table 2
Subgroup and meta-regression summary.

Sensitivity analysis

Leave-one-out analysis confirmed the robustness of the pooled effect; no individual study exerted disproportionate influence (Fig. 4).

Figure 4
Leave-one-out influence analysis.

Publication bias

The funnel plot was symmetrical, and Egger’s test was non-significant (p = 0.2854), suggesting a low likelihood of publication bias (Fig. 5).

Figure 5
Funnel plot assessing publication bias.

Discussion

This synthesis reinforces that NMP significantly enhances graft viability, reducing early dysfunction and ischemic biliary injury relative to SCS6,8,16,17. Benefit remained consistent across donor age strata, preservation times and varying DCD proportions.

Normothermic preservation likely preserves mitochondrial integrity and hepatic energetic homeostasis—critical determinants of post-transplant recovery9-13. Experimental observations stress the need for standardized protocols when assessing mitochondrial respiration, as biopsy-processing delays can obscure true graft viability14.

From an economic standpoint, modelling studies indicate that, despite higher upfront costs, NMP may be cost-effective by decreasing organ discard and improving long-term outcomes. Logistic hurdles—device availability and staff training—persist but are steadily being overcome in high-volume centers.

Limitations

The restricted number of studies, methodological heterogeneity among observational cohorts, and variability in outcome definitions limit generalizability. Large, multicenter RCTs with extended follow-up are warranted to assess survival impact and real-world cost implications across diverse healthcare systems.

Conclusion

NMP markedly reduces adverse events compared with SCS and represents a promising strategy to expand the donor pool and optimize graft function. Current evidence supports considering NMP the new standard for hepatic preservation, particularly for marginal or DCD grafts. Future research should address long-term outcomes, protocol standardization and economic-operational analyses.

Acknowledgements

Not applicable.

Research performed at Medical School, Universidade Federal do Acre, Rio Branco (AC), Brazil.

Funding

Not applicable.

Declaration of use of artificial intelligence tools

The authors declare that artificial intelligence tools were used, specifically Claude (Anthropic), to check spelling and formatting.

Data availability statement

All data are presented in the article.

References

  • 1 Gilbo N, Catalano G, Salizzoni M, Romagnoli R. Liver graft preconditioning, preservation and reconditioning. Dig Liver Dis. 2016;48(11):1265–74. https://doi.org/10.1016/j.dld.2016.06.031
    » https://doi.org/10.1016/j.dld.2016.06.031
  • 2 Harada N, Yoshizumi T, Mori M. Current review of machine perfusion in liver transplantation from the Japanese perspective. Surg Today. 2022;52(3):359–68. https://doi.org/10.1007/s00595-021-02265-x
    » https://doi.org/10.1007/s00595-021-02265-x
  • 3 Jayant K, Reccia I, Shapiro AMJ. Normothermic ex-vivo liver perfusion: where do we stand and where to reach? Expert Rev Gastroenterol Hepatol. 2018;12(10):1045–58. https://doi.org/10.1080/17474124.2018.1505499
    » https://doi.org/10.1080/17474124.2018.1505499
  • 4 Nasralla D, Coussios CC, Mergental H, Akhtar MZ, Butler AJ, Ceresa CDL, Chiocchia V, Dutton SJ, García-Valdecasas JC, Heaton N, Imber C, Jassem W, Jochmans I, Karani J, Knight SR, Kocabayoglu P, Malagò M, Mirza D, Morris PJ, Pallan A, Paul A, Pavel M, Perera MTPR, Pirenne J; Consortium for Organ Preservation in Europe. A randomized trial of normothermic preservation in liver transplantation. Nature. 2018;557(7703):50–6. https://doi.org/10.1038/s41586-018-0047-9
    » https://doi.org/10.1038/s41586-018-0047-9
  • 5 Chapman WC, Barbas AS, D’Alessandro AM, Vianna R, Kubal CA, Abt P, Sonnenday C, Barth R, Alvarez-Casas J, Yersiz H, Eckhoff D, Cannon R, Genyk Y, Sher L, Singer A, Feng S, Roll G, Cohen A, Doyle MB, Sudan DL, Al-Adra D, Khan A, Subramanian V, Abraham N, Olthoff K, Tekin A, Berg L, Coussios C, Morris C, Randle L, Friend P, Knechtle SJ. Normothermic machine perfusion of donor livers for transplantation in the United States: a randomized controlled trial. Ann Surg. 2023;278(5):e912–21. https://doi.org/10.1097/SLA.0000000000005934
    » https://doi.org/10.1097/SLA.0000000000005934
  • 6 Fodor M, Cardini B, Peter W, Weissenbacher A, Oberhuber R, Hautz T, Otarashvili G, Margreiter C, Maglione M, Resch T, Krendl F, Meszaros AT, Bogensperger C, Gasteiger S, Messner F, Henninger B, Zoller H, Tilg H, Öfner D, Schneeberger S. Static cold storage compared with normothermic machine perfusion of the liver. Br J Surg. 2021;108(9):1082–9. https://doi.org/10.1093/bjs/znab118
    » https://doi.org/10.1093/bjs/znab118
  • 7 Gaurav R, Butler AJ, Kosmoliaptsis V, Mumford L, Fear C, Swift L, Fedotovs A, Upponi S, Khwaja S, Richards J, Allison M, Watson CJE. Liver transplantation outcomes from controlled circulatory death donors: SCS vs in situ NRP vs ex situ NMP. Ann Surg. 2022;275(6):1156–64. https://doi.org/10.1097/SLA.0000000000005428
    » https://doi.org/10.1097/SLA.0000000000005428
  • 8 Croome KP, Subramanian V, Mathur AK, Aqel B, Mao SA, Clendenon JN, Perry DK, Dhanireddy K, Taner CB. Outcomes of DCD liver transplant using sequential normothermic regional perfusion and normothermic machine perfusion or NRP alone versus static cold storage. Transplantation. 2024;109(7):1184–90. https://doi.org/10.1097/TP.0000000000005301
    » https://doi.org/10.1097/TP.0000000000005301
  • 9 Jaber F, Abuelazm M, Soliman Y, Madi M, Abusuilik H, Amin AM, Saeed A, Gowaily I, Abdelazeem B, Rana A, Qureshi K, Lee TH, Cholankeril G. Machine perfusion strategies in liver transplantation: a systematic review and network meta-analysis. Liver Transpl. 2025;31(5):596–615. https://doi.org/10.1097/LVT.0000000000000567
    » https://doi.org/10.1097/LVT.0000000000000567
  • 10 Hoyer DP, Paul A, Luer S, Reis H, Efferz P, Minor T. End-ischemic reconditioning of liver allografts: Controlling the rewarming. Liver Transpl. 2016;22(9):1223–30. https://doi.org/10.1002/lt.24515
    » https://doi.org/10.1002/lt.24515
  • 11 Horváth T, Jász DK, Baráth B, Poles MZ, Boros M, Hartmann P. Mitochondrial consequences of organ preservation techniques during liver transplantation. Int J Mol Sci. 2021;22(6):2816. https://doi.org/10.3390/ijms22062816
    » https://doi.org/10.3390/ijms22062816
  • 12 Haque O, Pendexter CA, Wilks BT, Hafiz EOA, Markmann JF, Uygun K, Yeh H, Tessier SN. The effect of blood cells retained in rat livers during static cold storage on viability outcomes during normothermic machine perfusion. Sci Rep. 2021;11(1):23128. https://doi.org/10.1038/s41598-021-02417-6
    » https://doi.org/10.1038/s41598-021-02417-6
  • 13 van Leeuwen OB, de Vries Y, Fujiyoshi M, Nijsten MWN, Ubbink R, Pelgrim GJ, Werner MJM, Reyntjens KMEM, van den Berg AP, de Boer MT, de Kleine RHJ, Lisman T, de Meijer VE, Porte RJ. Transplantation of high-risk donor livers after ex situ resuscitation and assessment using combined hypo- and normothermic machine perfusion. Ann Surg. 2019;270(5):906–14. https://doi.org/10.1097/SLA.0000000000003540
    » https://doi.org/10.1097/SLA.0000000000003540
  • 14 Hofmann J, Kofler A, Schartner M, Buch ML, Hermann M, Zelger B, Öfner D, Oberhuber R, Hautz T, Schneeberger S, Meszaros AT. Assessment of mitochondrial respiration during hypothermic storage of liver biopsies following NMP. Transpl Int. 2024;37:12787. https://doi.org/10.3389/ti.2024.12787
    » https://doi.org/10.3389/ti.2024.12787
  • 15 Handley TJ, Arnow KD, Melcher ML. Despite increasing costs, perfusion machines expand the donor pool of livers and could save lives. J Surg Res. 2023;283:42–51. https://doi.org/10.1016/j.jss.2022.10.002
    » https://doi.org/10.1016/j.jss.2022.10.002
  • 16 Ibeabuchi T, Li E, Bittermann T, Mahmud N, Abt PL. Can ex-situ normothermic perfusion improve graft survival compared to static cold storage among DCD liver allografts? Liver Transpl. 2023;29(9):952–60. https://doi.org/10.1097/LVT.0000000000000143
    » https://doi.org/10.1097/LVT.0000000000000143
  • 17 Bral M, Dajani K, Izquierdo DL, Bigam D, Kneteman N, Ceresa CDL, Friend PJ, Shapiro AMJ. A back-to-base experience of human normothermic ex situ liver perfusion: does the chill kill? Liver Transpl. 2019;25(6):848–58. https://doi.org/10.1002/lt.25464
    » https://doi.org/10.1002/lt.25464
  • 18 Markmann JF, Abouljoud MS, Ghobrial RM, Bhati CS, Pelletier SJ, Lu AD, Ottmann S, Klair T, Eymard C, Roll GR, Magliocca J, Pruett TL, Reyes J, Black SM, Marsh CL, Schnickel G, Kinkhabwala M, Florman SS, Merani S, Demetris AJ, Kimura S, Rizzari M, Saharia A, Levy M, Agarwal A, Cigarroa FG, Eason JD, Syed S, Washburn WK, Parekh J, Moon J, Maskin A, Yeh H, Vagefi PA, MacConmara MP. Impact of portable normothermic blood-based machine perfusion on outcomes of liver transplant: the OCS Liver PROTECT randomized clinical trial. JAMA Surg. 2022;157(3):189–98. https://doi.org/10.1001/jamasurg.2021.6781
    » https://doi.org/10.1001/jamasurg.2021.6781
  • 19 Ghinolfi D, Rreka E, De Tata V, Franzini M, Pezzati D, Fierabracci V, Masini M, Cacciatoinsilla A, Bindi ML, Marselli L, Mazzotti V, Morganti R, Marchetti P, Biancofiore G, Campani D, Paolicchi A, De Simone P. Pilot, open, randomized, prospective trial for normothermic machine perfusion evaluation in liver transplantation from older donors. Liver Transpl. 2019;25(3):436–49. https://doi.org/10.1002/lt.25362
    » https://doi.org/10.1002/lt.25362

*

Corresponding author: miguelvalente001@gmail.com

Section editor:

Conflict of interest

Nothing to declare.

Publication Dates

  • Publication in this collection
    11 Sept 2026
  • Date of issue
    2026

History

  • Received
    28 July 2025
  • Accepted
    26 July 2026
location_on
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia https://actacirbras.com.br/ - São Paulo - SP - Brazil
E-mail: actacirbras@gmail.com
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo