Open-access Optimization of Electrocoagulation Parameters in a Continuous-Flow Cell with Iron Electrodes for the Treatment of Domestic Wastewater

Abstract

The direct discharge of Mollendo wastewater into the sea alters the marine ecosystem because it contains 99.9% of water and 0.1% suspended, colloidal and dissolved solids, which carry microorganisms, heavy metals and organic and inorganic pollutants. Therefore, the objective of this study was to optimize the parameters of the electrocoagulation process in a continuous-flow cell using iron electrodes to treat urban wastewater. The influence of applied voltage and operating flow rate on the removal of chemical oxygen demand (COD) was analyzed using response surface methodology (RSM) for process modeling and optimization. Additionally, the operating cost was determined based on energy consumption and electrode wear. The results showed that both variables significantly influenced the system efficiency. The optimization model predicted optimal conditions of a flow rate of 20 mL s-1 and a voltage of 9.5 V, with an estimated COD removal of 97%. This behavior was attributed to the anodic oxidation of Fe and the in situ generation of Fe2+ species, which promote the formation of hydroxides with high adsorption capacity and colloidal neutralization. Furthermore, the system had an operating cost of 0.481 USD per m3 of treated water and a sludge analysis was performed by X-ray fluorescence (XRF).

Keywords:
electrocoagulation; domestic wastewater; continuous flow; chemical oxygen demand; iron electrodes; response surface methodology


Introduction

One of the main challenges facing the world today is ensuring access to safe drinking water for the population, as well as properly treating wastewater before it is discharged into a receiving body of water.1 Furthermore, the direct discharge of domestic effluents with high concentrations of organic matter degrades aquatic ecosystems and poses a threat to health and the environment.2,3

Marine pollution is a global problem caused by the influx of urban, industrial, and agricultural waste, which negatively affects the goods and services provided by the sea, such as fisheries and tourism.4 Furthermore, the coastline of Peru is one of the most productive fishing areas in the world due to the current system and nutrient-rich upwelling, that enable the development of marine populations and constitute the hydrobiological resources of the pelagic ecosystem, in which the anchovy is the primary species.5

Conventional methods for treating this wastewater include activated sludge processes, oxidation ponds, biological filtration systems, anaerobic digesters, and others, which, despite their effectiveness, require a great deal of space and a long time to achieve purification.6,7 Other methods that can be applied include ionic flotation, coagulation/flocculation, adsorption, ion exchange, membrane techniques, among others.8,9 However, electrocoagulation is already used at industrial scale10 up to 10 L min-1 and is capable of removing even the smallest colloidal particles.11 Electrocoagulation (EC) is a water treatment technology that combines the principles of conventional coagulation, flotation, and electrochemistry.12 This technology has been established as an efficient alternative for water and wastewater treatment due to its high capacity to remove suspended solids, eliminate heavy metals, and destabilize emulsions, thereby facilitating the separation of contaminants present in the water.13

Compared to conventional chemical coagulation processes, EC offers advantages such as lower reagent consumption, low sludge generation, operational simplicity, and greater efficiency in contaminant removal.14 Consequently, this technology has attracted growing interest in wastewater treatment due to its efficiency, sustainability, and potential to reduce treatment costs.15

Furthermore, continuous EC offers advantages over batch EC due to its greater operational and economic efficiency, as it reduces treatment times and energy consumption, operates without interruptions, and ensures a constant supply of coagulant ions.16

In this context, the district of Mollendo, located in the Arequipa region of Peru, with a population of approximately 25,000,17 faces a problem associated with the lack of a domestic wastewater treatment plants; as a result, the wastewater is discharged with a chemical oxygen demand (COD) concentration of 670 mg L-1, a value that exceeds the maximum permissible limit (LMP)18 for effluents from domestic wastewater treatment plants in Peru (200 mg L-1) and the environmental quality standard (ECA) for marine-coastal ecosystems (10 mg L-1).19 This situation poses a risk to coastal biodiversity and public health, given the recreational and tourist importance of the beaches of Mollendo.20

EC involves applying electric current to sacrificial electrodes, typically made of iron. When these electrodes come into contact with contaminated water and an electric current is applied, anodic dissolution occurs, generating in situ coagulant species that promote colloidal destabilization, the oxidation of organic compounds, and solid-liquid separation.21,22 Although metallic electrodes exhibit removal capacities of 95% for organic matter, 94% for colloids, and 94% for total suspended solids,23,24 iron electrodes achieve higher removal percentages of 86% for heavy metals, 95% for organic compounds, and 97% for oils and greases under neutral or alkaline pH conditions and moderate current densities, with the formation of denser flocs and more compact sludge that facilitate separation and waste management in electrocoagulation systems.25,26 Furthermore, iron behaves more stably because it oxidizes to insoluble forms. At pH 8, in alkaline media, Fe2+ is oxidized and precipitates, adsorbing pollutants, with low sludge production during the reaction.27,28

The mechanism of EC involves an oxidation-reduction reaction: at the anode, the metal is released into the medium, while at the cathode, water is reduced, producing hydrogen gas and hydroxyl species.29,30 The reactions can be represented as follows:31

(1) A n o d e : Fe ( s ) → Fe 2 + ( ac ) + 2 e -
(2) Cathode: 2 H 2 O ( l ) + 2 e - → H 2 ( g ) + 2 OH ( ac ) -

The FeII and hydroxide ions form Fe(OH)2:32

(3) Fe 2 + ( ac ) + 2 OH ( ac ) - → Fe ( OH ) 2

As observed in Figure 1, Fe(OH)2 has a green color and is oxidized to yellow Fe(OH)3.

Figure 1
Formation and oxidation of Fe(OH)2 during the electrocoagulation process using iron electrodes.

The hydroxylated species formed, Fe(OH)2 and Fe(OH)3, have an amorphous structure and a high surface area, acting through mechanisms of adsorption, charge neutralization, and coagulation.

In this study, system efficiency was evaluated using COD reduction and the response surface methodology (RSM) to optimize the parameters of the electrocoagulation process in a continuous-flow cell for treating municipal wastewater. In addition, the operating cost was evaluated based on electrical energy and sacrificial electrode consumption, expressed in USD per m3 of treated water.

Experimental

Domestic wastewater was sampled in the coastal area of the city of Mollendo, located in the Arequipa region of Peru. A composite sample was collected at the main discharge points along the coastline, specifically at La Aguadita and El Muelle beaches, in accordance with the National Protocol for Monitoring the Quality of Surface Water Resources approved by the National Water Authority of Peru (ANA).33

Effluent characterization

The initial characterization of the effluent is presented in Table 1, showing a high pollutant load, primarily associated with organic matter and suspended solids. The COD concentration was 670 ± 5 mg L-1, the concentration of oils and fats was 61 ± 3 mg L-1, the total suspended solids concentration was 329 ± 5 mg L-1, and the concentration of thermotolerant coliforms 9.5 × 106 MPN (most probable number) per 100 mL, exceeding the maximum permissible limits established in Supreme Decree No. 003-2010-MINAM, Peru.18 In contrast, the pH (7.00 ± 0.02) and temperature (26 ± 2 °C) remained within the permissible ranges.

Table 1
Physicochemical and microbiological characterization of the domestic wastewater used in the electrocoagulation experiments

The in situ physicochemical characterization included the determination of pH, electrical conductivity, and temperature using a field-deployable multiparameter meter (Hanna HI98196, Italy), while turbidity was determined using a portable turbidimeter (VELP TB1, Italy). The collected samples were then stored and transported to the laboratory under refrigerated conditions at 4 °C to prevent physicochemical and microbiological alterations prior to analysis.

The oil and fat content was quantified using the Soxhlet extraction method (method 5520D), while COD was analyzed using the closed-reflux colorimetric method (method 5220D), in accordance with the procedures established in the Standard Methods for the Examination of Water and Wastewater,33 An ultraviolet-visible (UV-Vis) spectrophotometer (Techcomp S1010/S1020) was used for the COD analysis. All reagents used were of analytical grade (Pro Analysis).

Fecal coliforms were determined using the most probable number (MPN) method, in accordance with standard microbiological procedures.33 The results were expressed as MPN per 100 mL.

Continuous-flow EC cell

The rectangular reactor was constructed of acrylic material and measured 23 cm in height, 28.5 cm in length, and 19 cm in width, with a usable volume of 7 L. The system consisted of three functional sections: electrocoagulation, sedimentation, and an outlet zone. The reactor was equipped with six iron electrodes (Figure 2), arranged as three anodes and three cathodes, each 0.1 cm thick and with an effective area of 0.0221 m2 per electrode. The electrodes were connected to a variable-voltage direct-current power supply (0-90 V) via high-capacity cables (2/0 American Wire Gauge, AWG) and conductive rods.

Figure 2
Schematic diagram of the continuous-flow electrocoagulation cell system.

Experimental procedure

Among the most influential variables in a continuous-flow cell are the flow rate (Q) and applied voltage (V).34 The flow rate is related to the hydraulic retention time (HRT), which represents the time the wastewater remains in the reactor and therefore determines the period available for coagulant species generation, contaminant interaction, floc formation and growth, and subsequent separation. The HRT can be expressed as:35,36

(4) HRT = vol Q

where vol corresponds to the effective cell volume (mL) and Q to the operating flow rate (mL s-1). Furthermore, the applied voltage controls the current density of the system, regulating the rate of anodic dissolution and the generation of Fe2+ coagulant species.37 Likewise, m is the mass electrode dissolution and can be estimated using Faraday’s law.38

(5) m = I × t × M z × F

where I is the electric current (A), t is the operating time (s), M is the molar mass of the metal (g mol-1), z is the number of electrons transferred, and F is is the Faraday constant (96485 C mol-1).

Experimental design

For each experimental run, 7 L of wastewater were pumped through the reactor using a peristaltic pump under continuous-flow conditions. Three operating flow rates (20, 30, and 40 mL s-1) were evaluated, since flow rates above 10 mL s-1 have been reported as effective for COD removal in continuous-flow EC systems,34 along with applied voltage levels (7, 10, and 13 V) because previous studies39 reported higher COD removal at 7 V; however, very high voltages can increase temperature and energy consumption.

The response variable was COD removal, while the independent factors were applied voltage and flow rate. The interelectrode distance was kept constant at 1.5 cm, and the initial pH was adjusted to 7.0. The generated sludge was allowed to settle for 20 min, and the treated effluent was discharged from the clarification tank through an outlet valve.

The system behavior was analyzed using a 32 experimental design, with Q and V as independent variables. The experimental matrix and the average COD removal values obtained are presented in Table 2. The optimization and statistical evaluation procedures were performed using Statgraphics Centurion 19-X64, version 19.1.2.40

Table 2
Experimental design matrix and COD removal efficiency obtained at different flow rates and applied voltages

Removal efficiency was evaluated by comparing the COD at the system inlet and outlet, calculated using equation 6:41

(6) COD = ( COD i - COD f ) COD i × 100

where CODi and CODf represent the initial and final COD concentrations, respectively, expressed in mg L-1.

The mathematical model representing the process was obtained, and the optimization and statistical analyses were performed using Statgraphics Centurion 19-X64 software.

Energy consumption and economic analysis

In this study, the operating cost of the process (Cop) was estimated as the sum of the cost of electricity consumption (Cenergy) and the cost of metal electrode consumption (Celectrode), with both terms calculated based on the volume of treated water.42,43

(7) C op = C energy + C electrode

The cost of energy consumption was calculated based on the electrical operating conditions of the system, taking into account the applied voltage (V), the electric current (I), the treatment time (t), and the volume of treated wastewater (vol). In addition, the unit cost of electricity (B) was used to estimate the energy cost per unit volume, according to equation 8.44

(8) C energy = V × I × t × B vol

On the other hand, the cost associated with electrode consumption was estimated by considering the loss of metal mass during the process, calculated using equation 9.45

(9) C electrode = m × A vol

where A corresponds to the cost of the electrode metal (USD kg-1), m is the mass of dissolved electrode, and vol is the volume of treated water (m3).

Results and Discussion

Figure 3 shows COD removal under the different operating conditions.

Figure 3
COD removal efficiency obtained at different flow rates (20, 30 and 40 mL s-1) and applied voltages (7, 10, and 13 V) in the continuous-flow electrocoagulation process.

At a flow rate of 20 mL s-1, COD removal remained at 97% for all the evaluated voltages; this indicates that at this flow rate, the amount of coagulant generated at the low voltage of 7 V is sufficient to remove organic matter from the effluent. This behavior is associated with a more controlled anodic dissolution of iron, favoring the generation of Fe(OH)2 and flocs.46 These species agglomerate organic compounds,47-49 which contributes to the removal of pollutants.

Regarding the flow rates of 30 and 40 mL s-1, the organic matter removal efficiency decreased. This behavior is consistent with the findings reported by Abbasi et al.,50 who noted that an excessive increase in current density leads to accelerated hydrogen bubble formation, a reduction in bubble size, and turbulent dispersion of the flocs, thereby limiting their stability and contaminant capture efficiency.

Furthermore, at high flow rates, the contact time between the coagulants and the organic matter is insufficient for adsorption, flocculation, and sedimentation process.35 In this context, an increase in flow rate intensifies this effect by reducing effective contact between the generated metal hydroxides and the dissolved organic compounds, leading to premature floc saturation.51

According to Faraday’s law, the amount of coagulant generated in an electrocoagulation reactor depends directly on the applied current density and the hydraulic retention time. Therefore, longer HRT favor formation of coagulant hydroxides, which results in improved COD removal.47,52

Optimization of parameters

Based on the experimental results, a quadratic model was fitted to describe COD removal as a function of the variables evaluated. The statistical analysis of the effects is presented in the Pareto chart (Figure 4).

Figure 4
Standardized Pareto chart for the percentage of COD removal. (-) Indicates that lower values of flow rate and voltage favor higher COD removal efficiencies within the evaluated range, whereas (+) indicates the opposite effect.

The Pareto chart shows that flow rate (A) and voltage (B) had the greatest influence on COD removal, with both being statistically significant (p = 0.0001). Likewise, the interaction between the two variables (AB) was significant, indicating that the effect of voltage depends on the hydrodynamic regime imposed by the flow rate, and vice versa. This interaction shows a negative influence, and the mathematical model also indicates a negative effect within the operating ranges; as flow rate and voltage increase, as well as their interaction, COD removal decreases, whereas at low flow rates, voltage has no effect on removal.

In addition, process optimization requires a balance between the coagulant generation rate, which depends on voltage, and the effective contact time and turbulent mixing, which depend on the flow rate.

The negative influence of flow rate can be attributed to the fact that an increase in flow rate increases turbulence and decreases the contact time between the flocs and the organic matter, thereby limiting the formation, growth, and action of the metal hydroxides generated during electrocoagulation. On the other hand, increasing the voltage promotes the generation of coagulant species through the anodic dissolution of iron, therefore high potentials affect floc stability, thereby reducing process efficiency.

The optimization performed using the mathematical model predicted that the optimal operating conditions correspond to a flow rate of 20 mL s-1 and a voltage of 9.5 V, achieving an estimated COD removal of 97%. At that point, the coagulants generated in situ promote the formation of mononuclear and polynuclear complexes of Fe(OH)3. Roa-Morales et al.53 suggest that potentials close to 10 V optimize coagulant production without incurring excessive energy losses due to Joule heating or electrode passivation.

The flow rate of 20 mL s-1 allows the formation of coagulants with high adsorption capacity, facilitating the destabilization of colloidal organic matter particles, whose aggregation is promoted by the low turbulence in the flow regime. These conditions help maximize the efficiency of the electrocoagulation process. Compared to previous studies, the 97% removal predicted by the model exceeds that reported by Chen and co-workers,54 who obtained efficiencies close to 85% in a continuous reactor operating at similar current densities, attributing this limitation to the lower HRT of their system.

The mathematical model obtained to describe the percentage of COD removal is:

(10) Removal COD = 82.6452 + 0.619833 × Q + 2.50519 × voltage + 0.00231667 × Q 2 - 0.112833 × Q × voltage - 0.0131481 × voltage 2

The predictive power of the model is evidenced by a coefficient of determination (R2) of 99.88% and an adjusted R2 of 99.70%. These values indicate that the model not only explains virtually all the observed variability but also has a high capacity for generalization, minimizing the risk of overfitting due to irrelevant variables. The minimal difference between R2 and the adjusted R2 confirms the accuracy of the selected factors (Q and V) in predicting the performance of the continuous-flow cell.

Sludge analysis by XRF

Under optimal system operating conditions, sludge containing organic matter (COD) and inorganic contaminants was generated. Table 3 shows the elemental characterization of the sludge, performed using a Vanta M portable XRF, which revealed a matrix dominated by iron (47.64% by weight), due to the anodic dissolution of the electrode and the subsequent formation of ferric oxyhydroxides responsible for electrochemical coagulation.

Table 3
Elemental composition of the sludge generated under the optimal electrocoagulation conditions

In addition, concentrations of magnesium, silicon, aluminum, and calcium were 9.60, 6.33, 4.13, and 10.5 g kg-1, respectively, suggesting the coprecipitation and adsorption of mineral species originally present in the wastewater. The presence of sulfur and phosphorus, at concentrations of 7.94 and 1.51 g kg-1, respectively, indicates the capture of sulfate and phosphate compounds by the ferric flocs. Furthermore, trace metals such as chromium 0.6 g kg-1 and cobalt 1.6 g kg-1, were detected, demonstrating the ability of the system to immobilize potentially toxic metals through coprecipitation and surface adsorption onto amorphous Fe(OH)3.

Operating cost

The operating costs of the continuous-flow electrocoagulation process were estimated by considering energy consumption and iron electrode consumption, calculated based on experimental values for a voltage of 9.5 V, a current 6 A, an operating time 15 min, and a treated volume 7 L. Energy consumption was 0.0143 kWh, equivalent to a cost of 0.00224 USD for 7 L, while iron electrode consumption represented an approximate cost of 0.00113 USD. Overall, the total operating cost was 0.00337 USD for 7 L, which corresponds to 0.481 USD per m3 of treated water.

Conclusions

The results demonstrated that continuous-flow electrocoagulation using iron electrodes is an efficient alternative for removing oxidizable organic matter from domestic wastewater in coastal areas, reducing COD to levels that comply with the applicable maximum permissible limit (LMP). Statistical analysis showed that flow rate, associated with the HRT, and the applied voltage were the factors with the greatest influence on process efficiency. Optimization using the response surface model predicted an optimal flow rate of 20 mL s-1 and a voltage of 9.5 V, with an estimated COD removal of 97%. These conditions favor the generation of iron coagulant species and provide sufficient contact time for the destabilization and removal of organic matter. Finally, the process had an estimated operating cost of 0.481 USD per m3 of treated water.

Acknowledgments

The authors would like to thank UNSA for funding this research (UNSA INVESTIGA, grant IBA-IB-32-2020-UNSA).

Data Availability Statement

The data are available upon request from the authors.

References

  • 1 Macedo, H. E.; Lehner, B.; Nicell, J.; Grill, G.; Li, J.; Limtong, A.; Shakya, R.; Earth Syst. Sci. Data 2022, 14, 559. [Crossref]
    » Crossref
  • 2 Wołowicz, A.; Munir, H. M. S.; Sci. Total Environ. 2025, 958, 177948. [Crossref]
    » Crossref
  • 3 Lin, L.; Yang, H.; Xu, X.; Front. Environ. Sci. 2022, 10, 880246. [Crossref]
    » Crossref
  • 4 Le, V. G.; Nguyen, H. L.; Nguyen, M. K.; Lin, C.; Hung, N. T. Q.; Khedulkar, A. P.; Hue, N. K.; Trang, P. T. T.; Mungray, A. K.; Nguyen, D. D.; Environ. Chem. Lett. 2024, 22, 1257. [Crossref]
    » Crossref
  • 5 Salvatteci, R.; Gutierrez, D.; Field, D.; Sifeddine, A.; Ortlieb, L.; Caquineau, S.; Baumgartner, T.; Ferreira, V.; Bertrand, A.; Prog. Oceanogr. 2019, 176, 102114. [Crossref]
    » Crossref
  • 6 Shamshad, J.; Rehman, R. U.; Environ. Sci.: Adv. 2025, 4, 189. [Crossref]
    » Crossref
  • 7 Koul, B.; Yadav, D.; Singh, S.; Kumar, M.; Song, M.; Water 2022, 14, 3542. [Crossref]
    » Crossref
  • 8 Bassa, B. B.; Parikh, S. P.; Patel, S. R.; Sustainable Chem. One World 2026, 10, 100222. [Crossref]
    » Crossref
  • 9 Ayach, J.; El Malti, W.; Duma, L.; Lalevée, J.; Al Ajami, M.; Hamad, H.; Hijazi, A.; Polymers 2024, 16, 1959. [Crossref]
    » Crossref
  • 10 Al-Qodah, Z.; AL-Rajabi, M. M.; Al Amayreh, H. H.; Assirey, E.; Bani-Melhem, K.; Water 2025, 17, 2351. [Crossref]
    » Crossref
  • 11 Naldi, N.; Hazmi, A.; Desmiarti, R.; Emeraldi, P.; Andalas J. Electr. Electron. Eng. Technol. 2025, 5, 38. [Crossref]
    » Crossref
  • 12 Kim, T.; Phu, C.; Nguyen, P. L.; Viet, T.; Phung, B.; iScience 2025, 28, 111965. [Crossref]
    » Crossref
  • 13 Abbas, S. H.; Ali, W. H.; Am. J. Eng. Res. 2018, 7, 74. [Link] accessed in September 2026
    » Link
  • 14 Al-Qodah, Z.; Al-Shannag, M.; Hudaib, B.; Bani-Salameh, W.; Shawagfeh, A.; Assirey, E.; Case Stud. Chem. Environ. Eng. 2025, 11, 101183. [Crossref]
    » Crossref
  • 15 Rakhmania; Kamyab, H.; Yuzir, M. A.; Abdullah, N.; Quan, L. M.; Riyadi, F. A.; Marzouki, R.; Sustainability 2022, 14, 1985. [Crossref]
    » Crossref
  • 16 Companhia, B. J. F.; Scalize, P. S.; Environ. Sci. Pollut. Res. 2025, 32, 22163. [Crossref]
    » Crossref
  • 17 City Population; Mollendo (Islay, Region de Arequipa, Peru), Estadísticas de Población, Gráficos, Mapa, Ubicación, Clima, 2017. [Link] accessed in September 2026
    » Link
  • 18 Ministerio del Ambiente, Decreto Supremo No. 003-2010-MINAM, de 17 de marzo de 2010, Aprueban Límites Máximos Permisibles para los efluentes de Plantas de Tratamiento Residuales Domésticas o Municipales; Plataforma del Estado Peruano, Lima, Peru, 2010. [Link] accessed in September 2026
    » Link
  • 19 Ministerio del Ambiente, Decreto Supremo No. 002-2008-MINAM, de 31 de julio de 2007, Aprueban los Estándares Nacionales de Calidad Ambiental para Agua; Plataforma del Estado Peruano, Lima, Peru, 2007. [Link] accessed in September 2026
    » Link
  • 20 Robledo Ardila, P. A.; Álvarez Alonso, R.; Durán Valsero, J. J.; Morales García, R.; Árcega Cabrera, F.; Lamas Cosío, E.; Durán Laforet, S.; Environ. Sci. Pollut. Res. 2023, 30, 16852. [Crossref]
    » Crossref
  • 21 Garcia-Segura, S.; Eiband, M. M. S. G.; de Melo, J. V.; Martínez Huitle, C. A.; J. Electroanal. Chem. 2017, 801, 267. [Crossref]
    » Crossref
  • 22 Shahedi, A.; Darban, A. K.; Taghipour, F.; Jamshidi-Zanjani, A.; Curr. Opin. Electrochem. 2020, 22, 154. [Crossref]
    » Crossref
  • 23 Sudrajat, A. A.; Murniati, A.; Hardian, A.; J. Chem. Environ. 2025, 4, 27. [Crossref]
    » Crossref
  • 24 Namoussi, S.; Merbouh, C.; Kabriti, M.; Nahli, A.; Naamane, A.; Chlaida, M.; Iounes, N.; J. Ecol. Eng. 2022, 23, 183. [Crossref]
    » Crossref
  • 25 Singh, S.; Chaubey, A.; Kumar, A.; Kumar, A.; Int. J. Res. Appl. Sci. Eng. Technol. 2025, 13, 164. [Crossref]
    » Crossref
  • 26 Xu, L.; Xu, X.; Cao, G.; Liu, S.; Duan, Z.; Song, S.; Song, M.; Zhang, M.; J. Environ. Manage. 2018, 218, 129. [Crossref]
    » Crossref
  • 27 Tegladza, I. D.; Xu, Q.; Xu, K.; Lv, G.; Lu, J.; Process Saf. Environ. Prot. 2021, 146, 169. [Crossref]
    » Crossref
  • 28 Safira, R.; Elghali, A.; Benzaazoua, M.; Coudert, L.; Rosa, E.; Neculita, C. M.; J. Environ. Manage. 2024, 370, 122767. [Crossref]
    » Crossref
  • 29 Abbass, R. F.; Amooey, A. A.; AlJaberi, F. Y.; Results Chem. 2024, 9, 101613. [Crossref]
    » Crossref
  • 30 Olajire, A. A.; Chem. Eng. J. Adv. 2020, 4, 100049. [Crossref]
    » Crossref
  • 31 Moneer, A. A.; El Nemr, A. In Non-Conventional Textile Waste Water Treatment; El Nemr, A., ed.; Nova Science Publishers: New York, USA, 2012, p. 161.
  • 32 Qiu, A.; Qian, A.; Liao, P.; Xie, S.; Sep. Purif. Technol. 2025, 354, 129224. [Crossref]
    » Crossref
  • 33 Autoridad Nacional del Agua (ANA); Resolución Jefatural No. 010-2016-ANA, de 11 de enero de 2016, Protocolo Nacional para el Monitoreo de la Calidad de los Recursos Hídricos Superficiales; Plataforma del Estado Peruano, Lima, Peru, 2016 [Link] accessed in September 2026; Standard Methods Committee of the American Public Health Association, American Water Works Association, and Water Environment Federation In Standard Methods for the Examination of Water and Wastewater, 24th ed.; Lipps, W. C.; Braun-Howland, E. B.; Baxter, T. E., eds.; American Public Health Association: Washington, DC, USA, 2023.
    » Link
  • 34 Mehralian, M.; Ehrampoush, M. H.; Ebrahimi, A. A.; Dalvand, A.; Appl. Water Sci. 2023, 13, 162. [Crossref]
    » Crossref
  • 35 Kobya, M.; Gengec, E.; Demirbas, E.; Chem. Eng. Process. 2016, 101, 87. [Crossref]
    » Crossref
  • 36 Kobya, M.; Omwene, P. I.; Ukundimana, Z.; J. Environ. Chem. Eng. 2020, 8, 103526. [Crossref]
    » Crossref
  • 37 Quispe-Ramos, K.; Melgar-Izaguirre, E.; Rivera-Rodríguez, J.; Gutiérrez-Cuba, C.; Carrasco-Venegas, L.; Rodriguez-Aburto, C.; Ramos-Balcázar, Y.; Pilco-Nuñez, A.; Appl. Sci. 2025, 15, 10452. [Crossref]
    » Crossref
  • 38 Gasmi, A.; Ibrahimi, S.; Elboughdiri, N.; Tekaya, M. A.; Ghernaout, D.; Hannachi, A.; Mesloub, A.; Ayadi, B.; Kolsi, L.; ACS Omega 2022, 7, 22456. [Crossref]
    » Crossref
  • 39 Terrones-Díaz, K. L.; Segura-Vera, S. S.; Huerta-Chombo, G. L.; Sustainability 2025, 17, 7803. [Crossref]
    » Crossref
  • 40 Statgraphics Centurion 19-X64, version 19.1.2; Statgraphics Technologies, Inc., The Plains, VA, USA, 2020.
  • 41 Asefaw, K. T.; Asaithambi, P.; Tegegn, M.; Appl. Water Sci. 2024, 14, 54. [Crossref]
    » Crossref
  • 42 Sadaf, S.; Roy, H.; Fariha, A.; Rahman, T. U.; Tasnim, N.; Jahan, N.; Sokan-Adeaga, A. A.; Safwat, S. M.; Islam, M. S.; J. Water Process Eng. 2024, 62, 105409. [Crossref]
    » Crossref
  • 43 Ebba, M.; Asaithambi, P.; Alemayehu, E.; Appl. Water Sci. 2021, 11, 175. [Crossref]
    » Crossref
  • 44 Patel, S. R.; Pathan, M.; Nayak, M. G.; Parikh, S. P.; Rajaraman, T. S.; Ambegaonkar, N. J.; Trivedi, J. B.; Results Eng. 2024, 22, 102361. [Crossref]
    » Crossref
  • 45 Garg, K. K.; Prasad, B.; J. Environ. Chem. Eng. 2016, 4, 178. [Crossref]
    » Crossref
  • 46 Villon, A. E.; Romero, W. R.; Tecnia 2019, 29, 19. [Crossref]
    » Crossref
  • 47 Othmani, A.; Kadier, A.; Singh, R.; Igwegbe, C. A.; Bouzid, M.; Aquatar, M. O.; Khanday, W. A.; Bote, M. E.; Damiri, F.; Gökkuş, Ö.; Sher, F.; Environ. Res. 2022, 215, 114294. [Crossref]
    » Crossref
  • 48 Hakizimana, J. N.; Najid, N.; Gourich, B.; Vial, C.; Stiriba, Y.; Naja, J.; Chem. Eng. Sci. 2017, 404, 530. [Crossref]
    » Crossref
  • 49 Hakizimana, J. N.; Gourich, B.; Chafi, M.; Stiriba, Y.; Vial, C.; Drogui, P.; Naja, J.; Desalination 2017, 404, 1. [Crossref]
    » Crossref
  • 50 Abbasi, S.; Mirghorayshi, M.; Zinadini, S.; Zinatizadeh, A. A.; Process Saf. Environ. Prot. 2020, 134, 323. [Crossref]
    » Crossref
  • 51 Ogedey, A.; Oguz, E.; Environ. Sci. Pollut. Res. 2024, 31, 11243. [Crossref]
    » Crossref
  • 52 Safari, S.; Aghdam, M. A.; Kariminia, H. R.; Int. J. Environ. Sci. Technol. 2016, 13, 231. [Crossref]
    » Crossref
  • 53 Roa-Morales, G.; Barrera-Díaz, C.; Balderas-Hernández, P.; Zaldumbide-Ortiz, F.; Reyes Perez, H.; Bilyeu, B.; J. Mex. Chem. Soc. 2014, 58, 362. [Link] accessed in September 2026
    » Link
  • 54 Hu, R.; Liu, Y.; Zhu, G.; Chen, C.; Hantoko, D.; Yan, M.; J. Water Process Eng. 2022, 45, 102462. [Crossref]
    » Crossref

Editor handled this article:

Cristiane Luísa Jost (Associate)

Publication Dates

  • Publication in this collection
    26 Oct 2026
  • Date of issue
    2026

History

  • Received
    06 July 2026
  • Accepted
    18 Sept 2026
  • Published
    13 Oct 2026
location_on
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo