Abstract
The Doubly Fed Induction Motor (DFIM) is essential in Wind Energy Conversion Systems (WECS) for efficient wind energy harvesting. Conventional power converters in WECS often result in high Total Harmonic Distortion (THD) in output voltage and current, affecting wind energy economy. This research proposes replacing conventional converters with Modular Multi-level Converters (MMC) due to their scalable topology, low harmonic distortion, high efficiency, and the elimination of DC link capacitors. The MMC is connected in a back-to-back configuration between the rotor of the DFIM and the grid to enable four-quadrant operation. Circulating current in the MMC is minimized using a Modified Deer Hunting Optimization (MDHO) based Fractional Order PID (FOPID) controller and a Mexican Axolotl Optimization (MAO) based FOPID. Capacitor voltage balancing is achieved using Level-Shifting PWM (LSPWM) and Three-Dimensional Space Vector PWM (3D-SVPWM) techniques with voltage sorting algorithms. The impact of these control and modulation techniques on the DFIM is analyzed in terms of reduced THD, and steady state and transient performance. Simulations are conducted in MATLAB/R2022a, and experimental validation is performed using a 7-level 0.5 kW MMC in a Hardware-In-Loop (HIL) setup.
Keywords:
Doubly Fed Induction Motor (DFIM); Modular Multi-level Converter (MMC); Fractional Order PID (FOPID) Controller; Total Harmonic Distortion (THD) Reduction; Wind Energy Conversion System (WECS).
HIGHLIGHTS
Replaced conventional converters with MMC for improved efficiency and low harmonic distortion in WECS.
Applied MDHO and MAO-based FOPID controllers for MMC circulating current minimization.
Utilized LSPWM and 3D-SVPWM techniques for capacitor voltage balancing, enhancing DFIM performance.
INTRODUCTION
As energy demand is increasing day by day, the fossil fuel alone is not enough supply the demand. Moreover they are in extinction in near future. As an alternative, solar energy and wind energy have potential to meet the demand with zero emission. International Energy Agency (IEA) has forecasted that the solar and wind power generation will be doubled by 2028. To yield net zero emission in the year 2050, the wind energy generation should increase 17% of overall energy generation. The power conversion unit associated with wind energy generation has got great attention. The conventional converters suffered from worsen power quality issues in harvesting and integrating wind power to the grid. The Modular Multilevel Converters (MMC) have been replacing conventional converters because of its unique features like scalable in size, reduced THD in output current/voltage, elimination of DC-link capacitors and high efficiency. The following section explains in detail about the significant reviews on research work carried out by pioneer researchers in the area of wind power generation through Double Fed Induction Machines and power converters associated with it.
Various control techniques used for DFIGs such as direct torque control, Vector control and power control methods. The comparison among different control schemes in terms of steady state and transient state parameters, power quality parameters and dynamic response parameters was reported. This study would be helpful to analyze the impact of above mentioned parameters on torque ripple of DFIG [1]. The different control strategies adopted for MMC which was used in Permanent Magnet Synchronous generators (PMSM) and Doubly Fed Induction Generator (DFIG) to control the power quality parameters and power transfer between machine and grid. The comparison results for different control strategies were presented by conducting MATLAB simulation study [2]. A Fuzzy based control technique used to control DC link voltage and Carrier phase disposition technique used to control the capacitor voltage in MMCs used in two conversion stages based DFIG [3].
Optimized the performance of MMC by constructing mathematical model where more than one performance schemes were combining to improve overall performance. It was noted that the fundamental component of average output voltage affected by differential current injection [4]. The PV panels connected to sub-modules of hybrid MMC without involving chopper circuit. The method of injection of zero sequence voltage improved MMC performance under various shading conditions of MMCs [5]. A new MMC topology controlled by ANFIS-Social Ski Driver control technique to enhance the performance and address power quality issues in the transmission line [6]. An emulated Inertia controlled MMC for solar PV system which drastically vanishes sub-module capacitor voltage and it increased the grid inertia without any external devices [7]. A most powerful switching technique for nine-level MMC performance improvement known as Pseudo Random Multi-carrier Pulse width modulation. This scheme improved power quality parameters for the typical value of modulation ranging from 0.1 to 0.9. [8]. A Nearest Level modulation scheme for a novel MMC topology called Modular DC-link Inverter. It resulted in increased output parameters of MMC with reduced THD [9].
A novel technique to detect and locate the fault in MMC with deep-learning used unsupervised learning phase. This method showed effectiveness when MMC connected in 4-terminal HVDC system [10]. A 5-level MMC connected back-back for four quadrant operation of WECS. The carrier based PWM technique improved system performance under steady-state and fault condition of WECS [11]. The fault current mitigation of WECS employed with MMC. It was motioned that DFIG severe grid side fault current mitigated easily by properly designing the arm impedance of MMC [12]. A novel bio-inspired algorithm called Wild Spider Optimization (WSO) used for tuning FOPID controller in reducing differential current circulation between sub-modules of MMCs [13]. A different control technique in controlling the output current and circulating current of MMC. The output current control was implemented in two coordinate system while circulating current control was done in three-coordinate system using Adaptive PI controller [14].
The conventional SVPWM for balancing capacitor voltage where upper arm voltage and lower arm voltage were controlled independently. In this scheme, the direction of load current was chosen rather than Sub-module current direction for better voltage balancing [15]. The sampled average PWM scheme in which the modulating signal generated by taking average of nearest level sub-module voltage. It also reduced zero sequence voltage to null value [16]. The effect of circulating current control and harmonic voltage injection [17]. This issue had been well addressed by multi-objective a new technique to minimize the peak value of arm-current without allowing the capacitor size to increase. It was addressed by ensuring the circulating current phase angle to follow the reference voltage generated [18]. Various sub-modules topologies used in MMC and Its PWM techniques have been reviewed. This review study is carried out a simulation study using PSIM software and the results compared [19].
The gain adjustment of FOPID controller using conventional PSO and ABC algorithms which showed the good dynamic performance in terms of steady state and transient performance [20]. The different control schemes to control switching angle of 21-level MMC to improve performance and power qualities parameters has been implemented [21]. The different switching schemes for reducing THD present in output voltage/current of MMC implemented. The combination of two algorithms namely improved equalization and insertion sorting for balancing capacitor voltage yielded better results [22]. The machine learning techniques to model the power converters which could replicate real time operating parameters of MMC implemented [23]. A 3-phase NPC inverter with hysteresis current controller and 3D-SVPWM controller switching techniques implemented. It was concluded that 3D-SVPWM technique yielded better performance [24]. The simplified form of 3D-SVPWM technique applicable for 3-phase 4-wire MMC showed efficacy while implementing in HIL environment. The calculation time has been reduced comparatively by using curve fitting technique.
A model predictive control scheme has been proposed for MMC used in PMSM drive. It is used to get common-mode voltage reference to counterbalance capacitor voltage in high modulation index region [25]. A modular multilevel matrix converter has been proposed in which a common optimization based control implemented to perform circulating current minimization and speed control of variable speed drive [26]. The WECS with MMC in which reduced switching space vector based modulation technique has been proposed which could maintain second order harmonic circulating current and balanced capacitor voltage in each leg maintained within specific limit [27]. The MMC with hybrid switch combinations such as MOSFET and IGBT used in sub-modules which could reduce conduction losses and switching losses considerably [28].
Research Gap
The conventional power converters in WECS often result in high Total Harmonic Distortion (THD) in output voltage and current. This research proposes replacing conventional converters with Modular Multi-level Converters (MMC) due to their scalable topology, low harmonic distortion, high efficiency, and the elimination of DC link capacitors. As MMC suffers from circulating current issues and unbalanced capacitor voltage, the following methods have been proposed.
-
To minimize the circulating current to greater extend, two gain tuning meta-heuristic algorithms namely; MDHO and MAO are proposed for FOPID controller and implemented.
-
The capacitor voltage balancing of MMC is carried out using level-shifting PWM and 3D-SVPWM technique with Modified capacitor voltage sorting algorithm.
This research work is organized as follows in this paper: MMC and its mode of operation is detailed in section-2, Circulating current minimization using MDHO and MAO algorithm is described in section-3, capacitor voltage balancing using level-shift PWM and 3D-SVPWM is elaborated in section- 4, simulation study using MATLAB/R2023a simulink environment and finally experimental validation and results are discussed in section-5.
MODULAR MULTILEVEL CONVERTER
It is used in medium power to high power applications since it does not require additional DC-link capacitors, individually controllable sub-modules, flexible and scalable, easy fault handling capacity. The generalized modular multilevel converter (MMC) is shown in Figure 1(a). It has separate leg per phase and each leg is having two arms namely; upper and lower arm. The number of sub-modules ‘n’ is designed based on load requirement. In each arm, the inductors L(a,b,c) is provided for reducing circulating current . The floating capacitors are placed in mid-point of sub-module for voltage sharing across the switches. The common DC voltage VDC/2 is connected across mid-point of arm and midpoint of the leg is connected to the load.
Sub-module structure and its operating modes
The sub-modules are basic unit of MMC which decide the output voltage level. Generally they are connected in series both in upper arm and lower arm respectively as depicted in Figure 1 (a). Basically there are five structures of modules namely half-bridge, Full-bride, Clamp double, three-level flying capacitor (FC) and Three-level Neutral Point Clamped (NPC) sub-modules. In which Half-bridge sub-module is generally preferred because it uses minimal number of switches and capacitors. It consists of two switches S1,S2 and two anti-parallel diodes connected across the input capacitor C. The detailed operation of sub-modules is described in Figure 2. diagrammatically. The switching condition and status of input capacitor is given in Table 1.
MINIMIZATION OF CIRCULATING CURRENT
The circulating current flows if there is unbalanced voltage across the sub-modules of MMC. It is to be reduced because it affects the MMC output performance directly. In this proposed work, minimization of circulating current using MDHO and MAO based FOPID controller is implemented as depicted in Figure 3.
The output current of MMI can be mathematically expressed as:
The phase circulating current can be represented in matrix as follows
The Clarke transformation is used to convert three co-ordinates variables into two coordinate variables as given below
The error circulating current between actual value and calculated value is given as
Fractional Order PID controller
There are three parameters to be adjusted in conventional PID controller in which the value of µ and λ are maintained as unity. In case of FOPID controller, there are five to be tuned as mentioned in Figure 4.
Converting the above mentioned equation in s domain equation,
Based on the equation, the PWM signal is generated as given below
Vref,upp j and Vref,low j are generated to control the circulating current. This reference signals generated are applied to either LSPWM controller or 3D-SVPWM controller to balance the capacitor voltage.
Modified Deer Hunting Optimization Algorithm
Conventional optimization technique fails to yield accurate results sometimes because of lack of convergence and it takes longer time to solve non-linear problems. To overcome this issue, the researchers have been developing bio-inspired algorithm to perform optimization faster with fast convergence and give most accurate results. In this context, a deer hunting imitating algorithm has been developed and the deer hunting process is very difficult for the hunters as the deer escapes because of its inherent intelligence [29]. There are two senses in deer namely olfactory sense and visual sense found better which makes it escapes from getting hunted. It also alerts its community by louder sniffing and heavy treading when it feels dangerous environment as it is more sensitive to Ultra-High-Frequency (UHV) sound. The following section elucidates the deer hunting optimization phases.
Initialization:
The predators involved in the hunting process, wind angle and deer’s position angle are initialized in this phase as follows;
P is predator’s population, n-population size.
The wind angle in circular search can be calculated as
λ - is the random value in the range of [0,1] and c is the current iteration.
The best position angle of deer is calculated as
Position update:
The best position of predator to capture the deer at the initial stage is unpredicted as depicted in the Figure 5. There are two best positions assumed in this phase namely pioneer’s position and successor position. From the initial position, the hunter tries to adjust his position though trial and error process. To attack the prey effectively, the angle of visualization of the deer must be calculated in such a way that the deer is unaware of attack. The iteration factor is calculated in each trial based on later position of the hunter. The maximum time is taken in this phase because the position has to settle down its best position.
(i) Position update by leader’s position:
The hunter’s initial position is assumed randomly based on reference work carried out and then the encircling of deer by hunter is calculated as
-are the next position and current position of the hunter, Rsis random value taken in the range of 0 to 2. It is chosen based on wind speed calculation, the co-efficient vectors L and Y are modeled as
imax-is the maximum iteration and C is the random value existing between -1 and 1.
The follower moves forward if and only if the leader gives signal otherwise the follower has to wait in the same position though wind speed is favor to him.
(ii) Position update based on position angle:
The position angle of visualization is expressed as follows
The position angle update is calculated as follows
The new position can be mathematically modeled as
(iii) Position update based on position of successor:
The value of L is chosen as less than or equal to 1 and the same value is applied to hunter’s team. The new potion is written as
- is the position of followers from the current number in the searching team.
This process is continued till the value of L becomes greater than or equal to one. The major drawback of this process is premature convergence and it can be overcome by including Levy Flight Mechanism (LFM).
To control local search mechanism, LFM generates a random walk with the step size w, Levy index ɛ =1.5, generated samples A,B with mean value is 0 and variance is square of σ.
The new position of hunters after including LFM factor, it is expressed as
V is the random variable chosen between 0 and 2, is the position selected from current from current position. The flow chart of MDHO algorithm is shown in Figure 6.
For large-scale systems, the search space may get expanded which leads to low convergence speed. It also affects balancing of exploration phase and exploitation phase significantly for large scale systems. If parameters are not properly tuned in large search space, it gets affected by premature convergence and fails to address local optima. At last, it is essential to have larger memory and high end processors to yield accurate results at faster rate. Hence it is better to hybrid with other meta-heuristic algorithms to yield better results in large-scale systems.
Mexican Axolotl Optimization Algorithm (Mao)
This algorithm is imitating the Mexican Axolotl species which are found in water habitat like lake or deep water shallow. Generally axolotl are capable of regenerate its organs, amputated limbs and other tissues of the body. They also have the capacity of changing its color and size to escape from dangerous environment. The male axolotl will have sexual contact with female of best fatter for reproduction once in a year. They start breeding in warm water in summer of the year. They lay egg in various places of its habitat with capsule to ensure some of them to live for sure without having vision from predators. The proposed algorithm is inspired by the process of entire life cycle of axolotl like birth, regeneration of organs and restoration of tissues, breeding etc. The major advantage of this algorithm is that there is no chance for premature convergence as the entire population is divided into two separate populations namely; male population and female population. This process is carried out in three phases such as transition from its birth to adult in first phase, regeneration of organs and restoration is evolved in second phase and reproduction of new axolotl is taken places in third place. This makes the process to achieve accurate results without premature convergence and minimum number of iterations. The following section describes the MAO algorithm stages.
Initialize the population:
The initial population of axolotl is initialized randomly as given below.
Such that AjεP , 1≤ An≤ Aj, Aj= [Aj1, Aj2, Aj3….Ajn] with mini ≤ Aji ≤ maxi
Classify the population:
The sub-populations are obtained by assigning each individual either as male ‘M ‘population or Female ‘F’ population depending on their sex of axolotl.
Transition from larva to adult:
The best male mest and female fbestsub-population are selected as described below.
The transition probability for male axolotl is calculated as
If p(mj) is less than random number r, then mjn← mjn+(mbest,n-mjn)*λ or else mjn← mini+(maxi-mini)*r and then update mbest. This process of updating of female fbest sup-population is also carried out using same process.
Injury and Restoration:
In this phase, if r ≤ damaged probability for individual male axolotl, mjn← mini+(maxi-mini)*r is updated till r≤ regeneration probability is achieved and then optimized male population omj is updated in each iteration process to update mbest value. The same process is applicable for female axolotl also.
Reproduction and assortment:
The tournament size k is assigned and appropriate male axolotl mj is selected from male population M. Two eggs are obtained in such a way that e1i←mji and e2i←fji if the random number r≤0.5. The fitness of eggs are calculated and then e1,e2,fj, mj are arranged in ascending order. The best female fj is determined and then second best mj is determined. This position update is continued till stopping criterion (required value of gain for FOPID) is reached. The flowchart of MAO algorithm is depicted in Figure 7. The implementation of MDHO is much simpler and easier compared to MAO control algorithm. However MAO will give accurate results which leads to need of processors with high computational capability to run real time parameters. It also includes software integration, up gradation of hardware and training the operating persons etc.
CAPACITOR VOLTAGE BALANCING
Level-Shiting Pwm Technique
It is important to adopt a PWM technique to implement easily to trigger the sub-module switches of MMC. A carrier based PWM technique is one which uses fundamental reference signal compared against high frequency carrier signal to synthesize switching pulses and it is easier to implement with digital logic circuits. It reduced THD content in the output voltage/current and helps in capacitor voltage balancing of MMC along with sorting algorithm. There are two classes of carrier based PWM techniques namely; phase shift PWM in which carrier signals are horizontally disposed and level-shift PWM technique in which carrier signals are vertically disposed. In level-shift PWM itself, there are three types; PD-level shift PWM, POD-level shift PWM and APOD-level shift PWM. Among which PD-level shift PWM performs better in terms of output voltage magnitude and reduced THD in voltage/current.
In this scheme, there are [Number of level (n)-1] carrier signals placed equally in above and below the zero reference line and compared against sinusoidal reference with fundamental frequency as shown in Figure 8. The comparison rules are framed as follows;
-
i. If sinusoidal signal magnitude ≥ carrier signal magnitude, the result is assigned as ‘1’, otherwise it is assigned as ‘0’ for above the zero reference line.
-
ii. If sinusoidal signal magnitude ≥ carrier signal magnitude, the result is assigned as ‘0’, otherwise it is assigned as ‘-1’ for below the zero reference line.
-
iii. The resultant reference signal is addition of results of above mentioned condition. The pulses are derived from these conditions using digital technique.
Three-Dimesional SVPWM Tecnique
Space Vector Pulse Width Modulation (SVPWM) plays an important role in minimization of common mode voltage, elimination of Electro Magnetic Interference problem, optimum usage of DC-link voltage, reducing THD content in output and accurate capacitor voltage balancing. To implement capacitor voltage balancing effectively, it is obvious choice to implement a Three-Dimensional SVPWM (3D-SVPWM) technique as proved by Palanisamy et.al (2021). There is no need for transformation of quantities, easier calculation of switching time, unique switching state in vector space and finally no redundant switching states in 3D-SVPWM technique which makes smooth capacitor voltage balancing in MMC. The implementation of 3D-SVPWM technique is depicted in the Figure 9. The vector states in 3D-space and reference vector selection is shown in Figure 10.
In the actual cube, there exist eight sub-cubes with 27 switching states. The sub-cube can be decomposed into 6 prisms and each one is assigned with 4 switching states in their corner point. There are three steps followed in this technique; i) reference vector tracking in sub-cube located in actual prism ii) reference vector tracking in actual cube contains sub-prisms iii) switching time calculation. The reference vector is resolved into two components namely; offset voltage and two-level voltage and mathematically represented as
The normalized reference vector located inside the prism can be expressed as
The switching time calculation in each prism located in sub-cube of actual 3D-space can be calculated as follows;
Switching time in each
This switching time can be accomplished by sub-cube tracking followed by prism tracking and then integer value estimation to calculate normalized reference vector. Though Level-Shifting PWM (LSPWM) is economically viable as it requires fewer components, Three-Dimensional Space Vector PWM (3D-SVPWM) will be economically feasible as it improves overall system efficiency considering long-term energy saving in large scale WECS.
RESULTS AND DISCUSSION
A 1500VA rating MMC is constructed by using the components listed in the Table 2 where the switches are considered as ideal. The simulation study is carried out in MATLAB/R2023a platform. The switching pulses for sub-module switches are generated by level-shift PWM and 3D-SVPWM technique. First the switching pulses are generated by level-shift PWM applied to the switches. As a result, the output voltage per phase of 305 V with 15.26% THD and output current per phase of 3.51A with 16.23% THD are measured. Second the switching pulses are generated by 3D-SVPWM technique in which output voltage of 329 V with 5.11% THD and output current of 3.58 A with 4.56% THD are measured which is shown in the Figure 11 and Figure 12. The circulating current issues are also addressed by the same switching techniques which are discussed in the following section.
Minimization of circulating current
The unbalance terminal voltage of sub-modules in MMC results into flow of differential current or circulating current. Figure 13 shows the circulating current persisting in the output terminal of MMC with average magnitude of 0.9A with highly oscillating frequency. As it results in many undesirable effects on the DFIM performance, it has to be minimized. The gain adjustment of FOPID controller is done by using MDHO algorithm. It takes 262 iterations to settle down with minimized amplitude and less oscillating frequency at 0.14 seconds as shown in Figure 14. Then gain adjustment is carried out using MAO algorithm which takes 227 iterations to yield reduced amplitude of circulating current and minimum oscillating frequency at 0.102 sec as depicted in Figure 15. The steady-state and transient performance of different control algorithms are compared in Table 3. MAO-based FOPID controller outperforms all conventional and MDHO-based FOPID controllers.
Capacitor voltage balancing of MMC
The maximum capacitor voltage should be equal to source (DC) voltage/ Number of sub-modules. But the usage of conventional PWM techniques can’t maintain this voltage. Hence it is essential to use dedicated PWM techniques along with voltage sorting algorithm to balance the capacitor voltage. It is to be carried out in the following sequence; (i) sorting the capacitor voltage (ii) prediction of arm current direction (iii) sub-module selection (iv) Gate pulse generation. This procedure should be well adopted in any PWM technique chosen for MMC. Figure 16. Shows the measured voltage across capacitors when level-shifting PWM is applied which are highly oscillating in magnitude whereas Figure 17 shows capacitor voltage measured when 3D-SVPWM is applied which are less oscillating in magnitude compared to previous one. Figure 18 depicts the output voltage per phase before applying capacitor voltage technique and it is well balanced with 3D-SVPWM technique as shown in Figure19.
The experimental set-up of 7-level MMC is depicted in Figure 20 along with switching module. The hardware components used in the experimental set-up is listed in table. A high speed IRF840 MOSFET with VDS=500V,ID=8A,RDS=0.85Ω is used in MMC whose operating frequency is 50MHz. The switching pulses are generated in MATLAB/R2023a environment and real time switching pulses are taken through dSPACE-1202 front-end set up. There are voltage and current sensing elements to provide feedback signals to control desk in back end. The input DC voltage after rectification from grid voltage is 330V. When the level-shifting PWM technique is used for generation of switching pulses, the output voltage measured is 302 V with 17.23% THD and output current measured is 3.19A with 15.23% THD. This measurement is carried out by using Tektronix-4 channel MSO with AR22 probe. When 3D-SVPWM switching technique generates pulses, the output voltage is 314 V with 6.23% THD and output current measured is 3.28A with 5.65% THD as shown in Figure 21. The power quality analyzer Fluke-II 438 is used to analyze the THD present in output voltage/current. The circulating current is minimized using MAO-FOPID controller along with 3D-SVPWM technique in experiment as it yield better results in simulation. The circulating current is highly oscillating as depicted in Figure 22(a) with amplitude of 1.8A without tuning the gain of FOPID. However it has been reduced to 0.28A with MAO-based gain tuning algorithm as shown in Figure 22(b). The measurement of circulating current is carried out using mathfunc available in 4-channel Tektronix oscilloscope. The settling time measured for circulating current to settles down at 0.28A is 0.128 seconds. The sorting algorithm has been implemented along with 3D-SVPWM technique for capacitor voltage balancing. However the capacitor voltage is varying from 105 V to 115 V due to the presence of low amplitude circulating persisting in the sub-modules of MMC as shown in Figure 22. The average capacitor voltage is well balanced at 110V. The upper arm and lower capacitor voltage is shown in Figure 23. The performance comparison of different control techniques is given in Table 4.
(a). Output voltage (b). Output current (c). THD analysis of Output voltage (d). THD analysis of Output current
(a.) Circulating current measured before tuningFOPID gain. (b) Circulating current measured after tuning FOPID gain with MAO algorithm
CONCLUSION
The MMC play a vital role in Wind Energy Conversion System (WECS). The main issues of MMC are circulating current and unbalanced capacitor voltage in sub-modules. The circulating current minimization has been carried out using MDHO and MAO gain tuning algorithms. The capacitor voltage balancing of MMC is carried out using level-shifting PWM and 3D-SVPWM technique with modified capacitor voltage sorting algorithm. A detailed simulation study has been carried out using MATLAB/R2023a simulink environment. The results are validated by constructing a 0.5kW seven-level MMC. The MAO gain tuning algorithm outperforms MDHO algorithms which results circulating current is minimized to 0.28A at 0.128 sec. The modified capacitor voltage sorting algorithm is implemented with 3D-SVPWM technique which balances the capacitor voltage at 110V and outperforms level shifting PWM technique. However the capacitor is varying from 105 V to 115 V due to the presence of low amplitude circulating persisting in the sub-modules of MMC. In the future, the performance analysis of DFIM operating in four quadrants with the proposed schemes applied to back to back connected MMC and its impact analysis will be carried out.
Funding:
Acknowledgments:
None
Data Availability Statement:
Not informed the use of data, did not use research data
REFERENCES
-
1 Kumar B, Sandhu KS, Sharma R. Comparative analysis of control schemes for DFIG-based wind energy system. J Inst Eng (India) Ser B. 2021:1-20. doi:10.1016/j.jie.2021.01.001.
» https://doi.org/10.1016/j.jie.2021.01.001. -
2 Vardhan ASS, Sinha UK. Control strategies and performance analysis of doubly fed induction generator for grid-connected wind energy conversion system. Electr Eng. 2023:1-22. doi:10.1016/j.eleeng.2023.01.002.
» https://doi.org/10.1016/j.eleeng.2023.01.002. -
3 Kuchkulla N, Gaddam M, Narasimhulu V. Concert exploration of DFIG grid-integrated MMC using artificial intelligence. Eng Technol Appl Sci Res. 2023;13(4):11466-71. doi:10.1016/j.etar.2023.01.003.
» https://doi.org/10.1016/j.etar.2023.01.003. -
4 Liu Z, Li KJ, Wang J, Liu W, Javid Z. General model of modular multilevel converter for analyzing the steady-state performance optimization. IEEE Trans Ind Electron. 2020;68(2):925-37. doi:10.1109/TIE.2020.01.004.
» https://doi.org/10.1109/TIE.2020.01.004. -
5 Basu TS, Maiti S, Chakraborty C. Performance improvement of PV-fed hybrid modular multilevel converter under partial shading condition. IEEE Trans Ind Electron. 2020;68(10):9652-64. doi:10.1109/TIE.2020.01.005.
» https://doi.org/10.1109/TIE.2020.01.005. -
6 Sharma R, Makwana VH. Enhanced modular multi-level converter-based static synchronous compensator with social ski-driver optimized adaptive neuro-fuzzy inference system controller for power quality enhancement. Electr Eng. 2023:1-21. doi:10.1016/j.eleeng.2023.01.006.
» https://doi.org/10.1016/j.eleeng.2023.01.006. -
7 Sarojini RK, Palanisamy K, De Tuglie E. Emulated inertia control for a modular multi-level converter-based PV system to improve grid inertia. In: 2022 IEEE International Conference on Environment and Electrical Engineering and 2022 IEEE Industrial and Commercial Power Systems Europe (EEEIC/I&CPS Europe); 2022. p. 1-9. doi:10.1109/EEEIC.2022.01.007.
» https://doi.org/10.1109/EEEIC.2022.01.007. -
8 Kaliannan T, Albert JR, Begam DM, Madhumathi P. Power quality improvement in modular multilevel inverter using for different multicarrier PWM. Eur J Electr Eng Comput Sci. 2021;5(2):19-27. doi:10.1016/j.ejeecs.2021.01.008.
» https://doi.org/10.1016/j.ejeecs.2021.01.008. -
9 Kumar AR, Bhaskar MS, Subramaniam U, Almakhles D, Padmanaban S, Nielsen JBH. An improved harmonics mitigation scheme for a modular multilevel converter. IEEE Access. 2019;7:147244-55. doi:10.1109/ACCESS.2019.01.009.
» https://doi.org/10.1109/ACCESS.2019.01.009. -
10 Yang Q, Li J, Santos R, Huang K, Igic P. Intelligent fault detection and location scheme for modular multi-level converter multi-terminal high-voltage direct current. High Volt. 2021;6(1):125-37. doi:10.1016/j.hvol.2021.01.010.
» https://doi.org/10.1016/j.hvol.2021.01.010. -
11 Suresh Kumar LV, Salma U. Modular multi-level converter-based DFIG wind power system with MMC-STATCOM. Int J Ambient Energy. 2020;41(11):1243-51. doi:10.1016/j.ijae.2020.01.011.
» https://doi.org/10.1016/j.ijae.2020.01.011. -
12 De Souza VRF, Barros LS, Costa FB, Junior GPS. Doubly fed induction generator low voltage ride through improvement through modular multilevel converter. IEEE Access. 2022;10:57914-29. doi:10.1109/ACCESS.2022.01.012.
» https://doi.org/10.1109/ACCESS.2022.01.012. -
13 Balamurugan S, Nageswari S. Circulating current control of modular multilevel converter by wild spider foraging optimization-based fractional order proportional integral derivative controller. J Intell Fuzzy Syst. 2021;41(2):4127-47. doi:10.1016/j.jifs.2021.01.013.
» https://doi.org/10.1016/j.jifs.2021.01.013. -
14 Ishfaq M, Uddin W, Zeb K, Khan I, Ul Islam S, Adil Khan M, et al. A new adaptive approach to control circulating and output current of modular multilevel converter. Energies. 2019;12(6):1118. doi:10.1016/j.eners.2019.01.014.
» https://doi.org/10.1016/j.eners.2019.01.014. -
15 Dekka A, Wu B, Zargari NR, Fuentes RL. A space-vector PWM-based voltage-balancing approach with reduced current sensors for modular multilevel converter. IEEE Trans Ind Electron. 2016;63(5):2734-45. doi:10.1109/TIE.2016.01.015.
» https://doi.org/10.1109/TIE.2016.01.015. -
16 Dekka A, Wu B, Zargari NR. A novel modulation scheme and voltage balancing algorithm for modular multilevel converter. IEEE Trans Ind Appl. 2015;52(1):432-43. doi:10.1109/TIA.2015.01.016.
» https://doi.org/10.1109/TIA.2015.01.016. -
17 Lin L, Li A, Xu C, Wang Y. Multi-objective genetic algorithm-based coordinated second-and third-order harmonic voltage injection in modular multilevel converter. IEEE Access. 2020;8:94318-29. doi:10.1109/ACCESS.2020.01.017.
» https://doi.org/10.1109/ACCESS.2020.01.017. -
18 Marimuthu M, Vijayalakshmi S. Symmetric multi-level boost inverter with single DC source using reduced number of switches. Teh Vjesn. 2020;27(5):1585-91. doi:10.17559/TV-20190717065800.
» https://doi.org/10.17559/TV-20190717065800. -
19 Reddy GA, Shukla A. Circulating current optimization control of MMC. IEEE Trans Ind Electron. 2020;68(4):2798-811. doi:10.1109/TIE.2020.01.018.
» https://doi.org/10.1109/TIE.2020.01.018. -
20 Chandrasekaran K, Arthanari R. Fuzzy controlled THD reduction and performance improvement of a PMBLDC motor using MMLI. Teh Vjesn. 2021;28(2):439-46. doi:10.17559/TV-20200529182437.
» https://doi.org/10.17559/TV-20200529182437. -
21 Barros LA, Tanta M, Martins AP, Afonso JL, Pinto JG. Submodule topologies and PWM techniques applied in modular multilevel converters: Review and analysis. In: International Conference on Sustainable Energy for Smart Cities; 2020. p. 111-31. doi:10.1007/978-3-030-45312-1_19.
» https://doi.org/10.1007/978-3-030-45312-1_19. -
22 Demir BE, Demir F. Comparison of metaheuristic optimization algorithms for quadrotor PID controllers. Tech Gaz. 2023;30(4):1096-103. doi:10.17559/TV-20221108150435.
» https://doi.org/10.17559/TV-20221108150435. -
23 Basu A, Mohanty S. Tuning of FOPID (PI λ D μ) Controller for Heating Furnace. Int J Electron Eng Res. 2017;9(9):1415-37. doi:10.1016/j.ijeer.2017.01.020.
» https://doi.org/10.1016/j.ijeer.2017.01.020. -
24 Boukadoum A, Bouguerne A, Bahi T, Djebbar MS, Khechekhouche A. Four-leg inverter based on three-dimensional space vector modulation method for desired output frequency. Tech Gaz. 2024;31(3):688-95. doi:10.17559/TV-20230421000555.
» https://doi.org/10.17559/TV-20230421000555. -
25 Bingul Z, Karahan O. Comparison of PID and FOPID controllers tuned by PSO and ABC algorithms for unstable and integrating systems with time delay. Optim Control Appl Methods. 2018;39(4):1431-51. doi:10.1002/oca.2018.01.021.
» https://doi.org/10.1002/oca.2018.01.021. -
26 Bhavani M, Manoharan PS. A novel 21 level switched capacitor modular multilevel inverter using gray wolf optimization. J Electr Eng Technol. 2022;17(1):283-94. doi:10.1007/s42835-022-00122-w.
» https://doi.org/10.1007/s42835-022-00122-w. -
27 Givi H, Hosseini E, Farjah E. Estimation of batteries voltages and resistances in modular multilevel converter with half-bridge modules using modified PSO algorithm. In: 2021 12th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC); 2021. p. 1-7. doi:10.1109/PEDSTC.2021.01.023.
» https://doi.org/10.1109/PEDSTC.2021.01.023. -
28 Haq S, Biswas SP, Hosain M, Rahman M, Islam M, Jahan S. A modular multilevel converter with an advanced PWM control technique for grid-tied photovoltaic system. Energies. 2021;14(2). doi:10.1016/j.eners.2021.01.024.
» https://doi.org/10.1016/j.eners.2021.01.024.