Abstract
Purpose This study aims to establish a comprehensive protocol for assessing the morphometric parameters of the cervical vertebral canal using Magnetic Resonance Imaging (MRI) and to evaluate the interobserver reliability of these measurements.
Methods A descriptive study was conducted to evaluate the diameter and area of the cervical vertebral canal through MRI scans of 20 patients. Two independent observers performed the measurements, and interobserver reliability was assessed using Intraclass Correlation Coefficients (ICC).
Results The study detailed an effective method for evaluating both the diameter and area of the cervical vertebral canal, demonstrating excellent interobserver reproducibility for diameter measurements (ICC > 0.969) and good reproducibility for area measurements (ICC > 0.893).
Conclusion This protocol provides a standardized approach for measuring the cervical vertebral canal parameters, enhancing the evaluation of stenosis, and supporting precise clinical decision-making. The protocol is clear, reproducible, and adaptable for use in other research settings and clinical practices.
Keywords
Spinal stenosis; Cervical vertebrae; Magnetic resonance imaging; Standardization; Interobserver reliability
Introduction
Symptoms related to cervical spine disorders are among the most common musculoskeletal complaints worldwide and represent the fourth leading cause of disability. This highlights a major public health issue, as reported by Cohen1 and the 2017 Global Burden of Disease study, which estimated that neck pain affected approximately 288.7 million people.2
A major cause of neck pain is cervical spondylotic myelopathy, a degenerative condition frequently linked to spinal canal narrowing in the elderly.3 This narrowing may result from intervertebral disc herniation, osteophyte formation, or ossification of the posterior longitudinal ligament, leading to progressive spinal cord compression, ischemia, and functional impairment.
The correlation between spinal canal diameter and spinal cord compression is well-established.4-6 A reduced canal size, whether due to degenerative changes or congenital stenosis, increases the risk of myelopathy.7 The Torg-Pavlov ratio has been widely used to assess canal narrowing,8 but with broader access to Magnetic Resonance Imaging (MRI), morphometric evaluation has shifted toward MRI-based methods.9,10 Among MRI sequences, T2-weighted imaging is preferred for its ability to depict disc morphology and nucleus pulposus hydration.11
Some researchers have developed MRI-based classifications to standardize assessment of degenerative changes in the cervical spine and relate them to symptoms.12 Many studies analyze cervical vertebral canal dimensions to establish normative data,13-15 but often lack detailed measurement methods, which may explain result variability.9 Due to this inconsistency, a uniform standard for cervical stenosis evaluation is needed. This study proposes a step-by-step protocol to assess cervical canal parameters, aiming to standardize methods and improve clinical outcomes.
Methods
This descriptive study utilized Magnetic Resonance Imaging (MRI) to analyze the cervical spine and was approved by the Research Ethics Committee under protocol number 6.622.602 (CAAE: 72,726,723.1.0000.5440). This study was conducted using a secondary database composed of fully anonymized information with no individual identifiers; therefore, informed consent from participants does not apply. The study followed the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines for reporting observational research. To select the MRIs, scans from twenty patients who underwent cervical spine MRI at a specialized imaging center between January 2022 and December 2024 were randomly chosen. The two observers performed the measurements independently and were blinded to each other’s results. The patients were aged between 20 and 80-years and included both male and female participants. Examinations were excluded if they revealed fractures, tumors, infections, prior surgeries, malformations, or if the MRI protocol was not properly followed.
The final sample comprised 20 patients (11 females, 9 males) aged between 20- and 80-years (mean age: 47.3 ± 16.6 years). A sample size of 20 was chosen based on recommendations for reliability studies targeting an ICC > 0.90.16 This size is considered adequate to detect high interobserver agreement with two independent observers.
Imaging procedure
Magnetic resonance images were acquired using a 1.5T scanner (Signa; GE Medical Systems, Milwaukee, Wisconsin). Sagittal T2-weighted images were obtained using the Fast Spin Echo (FSE) sequence with the following specifications: Field of View (FOV) 24×24 cm, Repetition Time (TR) 2617 ms, Echo Time (TE) 118 ms, and slice thickness of 3 mm with a matrix of 320×224. Additionally, axial T2-weighted images were acquired with a FOV of 18×18 cm, TR of 896 ms, TE of 14 ms, and slice thickness of 3 mm with a matrix of 256×192.
All MRI evaluations were conducted on the same computer using Carestream Vue Motion software, version 12.1.5.1156 (software release year 2020), which provides advanced visualization, analysis, and management tools for medical images. Carestream allows high-resolution viewing and includes automated measurement and annotation tools that assist in consistent quantitative analysis. The platform also facilitates side-by-side image comparisons, allowing comprehensive evaluation of multiple conditions simultaneously.
After the initial image analysis by the senior researcher, a second researcher re-evaluated the same images using the same computer and software to ensure consistency and reliability in interobserver analysis. This approach was intentionally adopted to minimize technical variability and to isolate interobserver reliability related specifically to the measurement protocol, rather than differences in hardware or software platforms.
Measurements were performed from C3 to C7, as these levels are most commonly affected by cervical stenosis and provide reliable anatomical landmarks for reproducible measurements.
1. Vertebral Canal Diameter: Measured as the distance from the midpoint of the posterior vertebral body wall to the posterior structures (lamina/ligamentum flavum).
2. Vertebral Canal Area: Bounded anteriorly by the intervertebral disc and vertebral body, posteriorly by the laminae and ligamentum flavum, and laterally by the neural foramina and lateral masses. Axial measurements were taken at the mid-vertebral level, defined as the slice showing the largest cross-sectional area of each vertebral body.
This standardized methodology was designed to ensure measurement accuracy and enhance the robustness of the study findings.
Statistical analysis
Interobserver reliability of the measurement data obtained from MRIs was assessed using the Intraclass Correlation Coefficient (ICC) with a two-way mixed-effects model for absolute agreement, single measures. For ICC interpretation, the authors followed the guidelines by Koo and Li17: ICC values less than 0.50 indicate poor reproducibility, between 0.50 and 0.75 indicate moderate reproducibility, between 0.75 and 0.90 indicate good reproducibility, and values above 0.90 indicate excellent reproducibility.
Additionally, the authors employed the paired Student's t-test to compare the average values of measurements (diameters and areas) between Researcher 1 and Researcher 2 to check for statistically significant differences. All statistical analyses were performed using SPSS (version 25; IBM Corporation) at a significance level of 0.05.
Results
Sagittal evaluation
The first step involved positioning the images on the screen, with the T2-weighted sagittal view on the left and the T2-weighted axial view on the right. The authors adjusted the pixel magnification to 300% and positioned the image at the most central slice relative to the axial view (Fig. 1).
Sagittal (A) and axial (B) T2-weighted MRI images of the cervical spine demonstrating the anatomical landmarks used for cervical canal measurements. The posterior vertebral body wall is marked by an asterisk (*), the midpoint by a dot (.), and the ligamentum flavum by an arrow.
Automatic color correction was applied to ensure consistency, and the screen measurement tool was selected. The superior endplate was delineated, followed by the measurement of the vertebra's posterior wall (Fig. 2A). From this measurement, the Midpoint (MP) of the posterior wall was identified (Fig. 2B). A perpendicular line was then drawn from this midpoint to the posterior structures (ligamentum flavum/lamina), determining the vertebral canal diameter at that vertebral level (Fig. 2C). These steps were repeated from C3 to C7 (Fig. 2D), with the vertebral canal diameter at each level recorded in millimeters and documented in a spreadsheet.
Images illustrating the steps of superior endplate delineation and measurement of the vertebra's posterior wall (A), Midpoint (MP) identification of the posterior wall (B), determination of vertebral canal diameter at a vertebral level (C), and across all studied levels (D).
Axial evaluation
After selecting the axial image (Fig. 3B), a blue line was placed at the center of the sagittal slice to simultaneously identify the vertebral level to be assessed in the sagittal slice (Fig. 3A). The screen was aligned at the midpoint of each vertebra, and the freehand measurement tool was selected.
Upon selecting the axial image (B), a blue line is automatically displayed (A), positioned at the center of the sagittal diameter of the vertebral canal (A). Using the cursor, the area of the vertebral canal is outlined and measured in mm2 (C).
Using the cursor, the area of the vertebral canal was traced, and the measurement obtained in mm2 was entered into the spreadsheet (Fig. 3C). This process allowed us to obtain the vertebral canal area for segments C3 to C7.
Intraclass correlation coefficient (ICC)
The ICC analysis for diameters from C3 to C7 using sagittal evaluation showed excellent values for all studied levels, ranging from 0.969 to 0.995 (Table 1). Meanwhile, the ICC analysis for the vertebral canal area from C3 to C7 demonstrated results ranging from good to excellent, with values between 0.893 at level C6 and 0.956 at level C3 (Table 2).
Student’s t-test
Based on the paired t-test, using a significance level of 0.05, there was no statistical evidence of significant differences between measurements taken by Researcher 1 and Researcher 2 for any of the variables analyzed (diameters and areas from C3 to C7) (Table 3). All p-values were substantially greater than 0.05, suggesting that any observed differences between the mean values of the two observers are likely due to chance or sample variability.
Comparison of cervical canal diameter and area measurements between two independent observers using paired Student’s t-test.
The results presented in Table 3 further support the reliability of the measurements taken by both researchers, as no statistically significant differences were observed between their values. This indicates good reproducibility of the data, which is essential for the validity of the study. The consistency in measurements also contributes to the robustness of subsequent analyses, ensuring that any variations observed across the sample are more likely due to anatomical differences rather than measurement bias.
Discussion
This study aimed to present a detailed, reproducible MRI method for measuring cervical vertebral canal morphometry to support standardized cervical stenosis assessment and improve diagnosis. Interobserver reliability analysis showed excellent to good reproducibility for canal diameter and area measurements, with high ICC values (> 0.893) and no significant differences between observers (Student’s t-test).
The high ICC values for vertebral diameters (> 0.969) indicate consistent and accurate measurements across observers, emphasizing the need for standardization. The ICC values for cervical diameter (> 0.969) are comparable to or higher than those reported in previous studies.9 This high value likely reflects the benefit of the present detailed, standardized measurement protocol. Canal area measurements showed slightly lower but still good to excellent reproducibility, with the method effectively minimizing interobserver variability despite the complexity of delineating the area. This reliability is essential for clinical use and comparison with similar studies.
Although no statistically significant differences were observed between observers, interobserver reliability was primarily demonstrated by the high ICC values, which represent the main outcome of this study. This result suggests that the detailed methodology and researcher training successfully eliminated interobserver bias, ensuring the validity and consistency of the data obtained. Such reproducibility is vital for accurate interpretation of the morphometric parameters of the cervical vertebral canal and for making sound clinical decisions.
Developmental cervical canal stenosis is commonly defined based on MRI morphometric parameters, typically identified when the anteroposterior canal diameter is below 12‒14 mm.9,10 The T2-weighted sagittal sequence is widely used for the evaluation of cervical canal stenosis, justifying its use in the present study.11
Due to the lack of detailed methods for measuring cervical vertebral canal morphometry, this study provides a clear, reproducible protocol easily adopted by other centers and clinical practice.18-20 Using widely available imaging software and detailed steps, the method supports standardizing cervical stenosis evaluation and improving patient care. Overall, these findings emphasize the importance of standardized measurements and interobserver reliability for research and clinical use.
This study has some limitations. The relatively small sample size (n = 20), while sufficient for interobserver reliability analysis, limits the generalizability of the findings. In addition, this was a single-center study, and all measurements were performed using the same imaging workstation, which may have inflated ICC values compared to real-world settings where different monitors and software are used. Future studies should correlate the measurements obtained with this protocol to clinical outcomes (e.g., mJOA scores) to validate diagnostic thresholds for cervical canal stenosis.
Conclusion
This study successfully achieved the primary objective of establishing a detailed and reproducible protocol for measuring the morphometric parameters of the cervical vertebral canal in MRI examinations, validated through rigorous interobserver reliability analysis.
Ethical compliance statement
All authors declare that they have no conflicts of interest related to this study.
Ethics approval
This study was approved by the Research Ethics Committee of the Hospital das Clínicas, Ribeirão Preto Medical School, University of São Paulo (Opinion no. 6,622,602; CAAE: 72726723.1.0000.5440).
Funding
Data availability
All data generated or analyzed during this study are included in this published article.
Acknowledgments
The authors thank the University of São Paulo (USP) for institutional support and the Coordination for the Improvement of Higher Education Personnel for financial support. The authors also acknowledge the valuable contributions of the study supervisors, co-supervisors, and collaborators.
References
- 1 Cohen S.P. Epidemiology, diagnosis, and treatment of neck pain. Mayo Clin Proc. 2015;90(2):284-299.
-
2 GBD 2017 Disease and Injury Incidence and Prevalence Collaborators. Global Burden of Disease Study 2017. Seattle (US): Institute for Health Metrics and Evaluation (IHME); 2018 [cited 2025 Jul 4]. Available from: http://www.healthdata.org
» http://www.healthdata.org - 3 Wolf B.S., Khilnani M., Malis L. The sagittal diameter of the bony cervical spinal canal and its significance in cervical spondylosis. J Mount Sinai Hosp N Y. 1956;23(3):283-92.
- 4 Kessler J. Congenital narrowing of the cervical spinal canal. J Neurol Neurosurg Psychiatry. 1975;38(12):1218-1224.
- 5 Sasaki T., Kadoya S., Iizuka H. Roentgenological study of the sagittal diameter of the cervical spinal canal in normal adult Japanese. Neurol Med Chir (Tokyo). 1998;38(2):83-89.
- 6 Yoshida M., Otani K., Shimizu K., Nakamura T. Indication and clinical results of laminoplasty for cervical myelopathy caused by disc herniation with developmental canal stenosis. Spine (Phila Pa 1976). 1998;23(22):2391-2397.
- 7 Meskhi K.T., Vorona B.N. Minimally invasive fusion in patients with multilevel cervical spinal stenosis: case report and literature review. Burdenko’s J Neurosurg. 2019;83(2):109.
- 8 Pavlov H., Torg J.S., Robie B., Jahre C. Cervical spinal stenosis: determination with vertebral body ratio method. Radiology. 1987;164(3):771-775.
- 9 Ulbrich E.J., Schraner C., Boesch C., Hodler J., Anderson S.E. Normative MR cervical spinal canal dimensions. Radiology. 2014;271(1):172-182.
- 10 Kato F., Yukawa Y., Suda K., Yamagata M., Ueta T. Normal morphology, age-related changes and abnormal findings of the cervical spine. Part II: magnetic resonance imaging of over 1200 asymptomatic subjects. Eur Spine J. 2012;21(8):1499-1507.
- 11 Farshad-Amacker N.A., Hughes T., Herzog R.J. MR imaging of degenerative disc disease. Eur J Radiol. 2015;84(9):1768-1776.
- 12 Rüegg T.B., Aebli N., Winklhofer S., Ferguson S.J., Boszczyk B.M., Ulrich N.H. The diagnostic value of magnetic resonance imaging measurements for assessing cervical spinal canal stenosis. J Neurosurg Spine. 2015;22(3):230-6.
- 13 Chen I.H., Liao K.K., Shen W.Y. Measurement of cervical canal sagittal diameter in Chinese males with cervical spondylotic myelopathy. Zhonghua Yi Xue Za Zhi. 1994;54(2):105-10.
- 14 Lee H.M., Kim N.H., Kim H.J., Chung I.H. Mid-sagittal canal diameter and vertebral body/canal ratio of the cervical spine in Koreans. Yonsei Med J. 1994;35(4):446.
- 15 Pawar K.A., Meena R.K., Rohilla R., Malhotra R. Roentgenographic and computerized tomography based morphometric analysis of cervical spinal canal diameters to establish normative measurements in an Indian population. J Clin Orthop Trauma. 2017;8(2):185-190.
- 16 Walter S.D., Eliasziw M., Donner A. Sample size and optimal designs for reliability studies. Stat Med.1998;17(1):101-110.
- 17 Koo T.K., Li M.Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155-163.
- 18 Fehlings M.G., Tetreault L.A., Riew K.D., Middleton J.W., Aarabi B., Arnold P.M., et al. A clinical practice guideline for the management of patients with acute spinal cord injury: recommendations on the type and timing of anticoagulant thromboprophylaxis. J Neurosurg Spine. 2015;14(3):303-304.
- 19 Stillman M.D., Capron M., Alexander M., Di Giusto M.L., Kim H., Montanez J., et al. Health care utilization and barriers experienced by individuals with spinal cord injury. Spinal Cord. 2020;58(5):588-97.