Abstract
This research provides detailed examination of the peak spatial Specific Absorption Rate (psSAR) in different age students in a classroom with wireless computers. This is motivated by the escalating inclusion of electronic devices in educational settings and the necessity to estimate the implications of this on the overall radio-frequency exposure. Two classrooms with posable realistic human models are simulated. One filled with several 7 years old children and another with several 43 years old adult, each using a laptop. The 1 g and 10 g psSAR are calculated for the head, back and hands. The distances between students are varied and the results compared to one student alone. A small free distance between rows (10 cm) produces significant reduction in psSAR (around 13 dB). Results are less sensitives to changes in lateral distance. While the maximum simulated psSAR values are below the recommended limits, it is observed that, in some classroom arrangements, the psSAR can be substantially increased (e.g., up to 26 dB in the back) comparing to just one student with his laptop. One objective of this study is to provide guidelines for the design of safer classrooms in the context of widespread laptop usage.
Index Terms
EMF exposure; Multiple sources in classroom; Specific Absorption Rate; Wireless Communication Systems.
I. INTRODUCTION
In recent years, exposure to RF radiation has become a growing concern due to the widespread use of electronic devices and wireless communication systems [1]. Exposure to electromagnetic fields (EMF) from multiple sources has not been adequately studied, and this is particularly relevant in environments such as classrooms, where several devices can be in use simultaneously. Wireless networks are widely in use in schools and students have access to computers without having to go to laboratories. Many papers have discussed network requirements such as the logistic, system administration and security, or pedagogic issues such as learning enhancement and education strategies. However, very few papers addresses the EMF exposure from wireless laptops (or desktops). This work hypothesized that increasing the desk spacing will reduce the exposure to EMFs.
In the near field, human exposure to EMFs is generally assessed in terms of the Specific Absorption Rate (SAR). It relates the power absorbed (e.g., in watts) to the tissue mass considered (e.g., in kilograms) and it is a measure of the rate at which energy is absorbed by the human body when exposed to an EMF. This is given as a function (1) of the RMS electric field intensity (E), the electric conductivity of the tissue (σ), its volume (V ) and mass density (ρ):
The SAR limit recommended by the International Commission on Non Ionizing Radiation Protection (ICNIRP) is 2 W/Kg estimated in a cube with a mass of 10 g [2] and by the US Federal Communication Commission (FCC) is 1.6 W/Kg, in a cube with 1 g [3], [4]. The peak spatial Specific Absorption Rate (psSAR) is the maximum SAR value estimated in a given volume or mass (e.g., 10 g or 1 g of tissue).
Despite the increasing use of electronic devices leading to exposure to electromagnetic radiation from multiple sources, there is a relative lack of research specifically addressing the analysis of the SAR due to these multiple sources. Much of the existing literature addresses devices using Multiple-Input Multiple-Output (MIMO) technology. References [5]-[13] describe several works including multiple sources. However they do not consider the situation in the classroom, and do not specify the psSAR in different regions of the human body. This work aims to investigate exposure to EMFs from multiple sources in a classroom environment, using electromagnetic simulations to calculate the psSAR in a 7 years old child and in a 43 years old adult realistic models. It is believed that the results of this research can contribute to a better understanding of the potential effects of exposure to EMFs in function of the age and to provide guidelines for the design of safer classrooms.
II. METHODOLOGY
The proposed problem requires representing a classroom in which each student has a wireless laptop in his desk as the main RF sources (the model can be seen in Fig. 1). This is a huge computational problem that requires massive resources in such wise simplification of the model is necessary or desired to allow several simulations to be carried out.
The simulation domain (i.e. the classroom, the furniture and the student bodies) and its discretization (i.e. the mesh), boundary and initial conditions as well as the RF sources and the emitted frequencies are chosen in a compromise between the fidelity of representation and the feasibility of simulations. The sitting arrangement is a classic rows and columns, and the simulations are repeated for different distances between the students, starting at zero cm. This allows us to use the periodic boundary condition. The exposures in other sitting arrangements (such as two columns side by side) are expected to be lower than those in the minimum simulated distances. The lateral distances between the desks (represented by black solid arrows in Fig. 2) are fixed in 40 cm, and the front to back distances (red hollow arrows in Fig. 2) vary from 0 cm to 100 cm. Then, the front to back distances between rows are fixed in 10 cm and the side distances vary from 0 cm to 80 cm. Simulations were performed using the CST Studio Suite®.
A. The Periodic Boundary Condition
The use of a Periodic Boundary Conditions (PBC) reduces the simulation domain to one unit cell including the realistic human model, the desk, the laptop, the chair, the floor and the ceiling. This can be replicated infinitely in the two horizontal directions while in the vertical direction open boundary conditions such as the Perfectly Matched Layer (PML) or Absorbing Boundary Condition (ABC) are used. This reduces the problem size from a whole classroom full of students, to a single student. Since the reflections on the ceiling are very low, we neglected it by placing the PML around ¼ wavelength above the human model (which is around 3.1 cm in the air for 2.45 GHz), significantly reducing the height of the cell (as shown in Fig. 3a from the front perspective and Fig. 3b from the back perspective).
Simulations were also performed with only one student with his laptop and Perfect Matched Layers (PML) in all directions to avoid reflections in order to compare the exposure increase between the student alone and all the students in the classroom.
The use of PBC implies that all the sources are in phase. To investigate the impact of phase correlation between sources on the calculated SAR, a simulation was conducted using a model consisting of nine cells with a spherical homogeneous phantom with 12 cm radius having an electrical conductivity of 0.943 S/m and a relative permittivity of 55.03. Individuals were positioned with a spacing of 60 cm between columns and 77 cm between rows. The notebooks and the antennas are described in item C of this section. The distances between the antennas and the students in a column are 13 cm (to the classmate in the front) and 43 cm (to the student using the notebook). Within a 3x3 unit cell domain, individual simulations with randomly varying phase were performed for each source. Then by postprocessing, the resulting electric field was calculated. After one hundred phase combinations (using uniform distribution functions), the average 1g-psSAR obtained was 25.96 mW/kg (standard deviation of 6.37 mW/kg) and the average 10g-psSAR was 21.07 mW/kg (standard deviation of 5.03 mW/kg). Comparatively, the 1g-psSAR in the case where all sources were in phase was 30.32 mW/kg, while the 10g-psSAR was 25.42 mW/kg. These results are presented in Table I
1g and 10g psSAR for the 3x3 Cell Domain Simulation: 100 Repetitions of Phase Variation and In-Phase Results
To further understand the individual contributions of each source and the impact of their placement, simulations were conducted with single active sources. When the source was positioned 43 cm in front of the student, the resulting 1g-psSAR was 1.08 mW/kg, and the 10g-psSAR was 0.912 mW/kg. Conversely, with the source located 13 cm behind the student, the 1g-psSAR significantly increased to 23.9 mW/kg, and the 10g-psSAR reached 19.6 mW/kg. Finally, simulations performed using a single source within the PBC yielded a 1g-psSAR of 46.9 mW/kg and a 10g-psSAR of 39.8 mW/kg.
These results indicate that the phase correlation between sources did not lead to a significant increase in the calculated ps-SAR, suggesting that the effect of widespread constructive interference may be mitigated by scattering and absorption in the simulated environment.
B. The Unit Cell
The unit cell comprises the realistic model of the student, the furniture and the laptop. Its dimensions vary according to each of the two human models considered. For the two human models the unit cells dimensions are w × d × h. The cell width w and cell depth d parameters for the child were varied according to Table II. The cell widths for both models are the same (since both models use the same desk) but the cell depths for the adult are increased by 7 cm (for larger space between the chair and the desk). The cell height h was fixed at h = 149 cm for the adult and h = 105 cm for the child. Considering the ceiling would imply a significant increase in computer resources. In Table III an h =250 cm cell with ceiling and the h =105 cm cell without ceiling results are compared, showing that the ceiling effect could be neglected, then saving computing time.
The impact of considering or not the ceiling in the model. psSAR for the 7 y-o child with and without ceiling (and fixed 0 cm between rows and columns)
Realistic posable (i.e. articulated) human models were chosen for more precise estimation and in order to assess dosimetry in different tissues. Both models,“Laura 2.0” (used in Fig. 2) and “Child 7Yf” (in Fig. 3), are available with the CST Studio Suite® as well as the dielectric properties of its tissues. The height and weight of the models are 163 cm and 51 kg for the 43 y-o adult woman and 115 cm and 21.7 kg for the 7 y-o girl. The resolution is 1 mm in both models and the number of tissues represented, 44 and 43 respectively. Clothes are neglected.
The furniture was modeled in an extremely simplified way, without any detail and with straight planes, parallel to the mesh axis, to reduce its density. For ergonomic reasons, there is a holder below each laptop. This also allows the laptop lid (Fig. 4a) and then, the antenna inside it (Fig. 4b), to be conveniently parallel to the mesh axis, reducing the meshing complexity and increasing the results reliability. The desks and chairs are made of wood, in which the dielectric constant is 1.65 and the dielectric loss tangent is 0.035. The laptop case is made with ABS (Acrylonitrile Butadiene Styrene), in which the dielectric constant is 2.75 and the dielectric loss tangent is 0.012.
A coarser mesh is desired for computational efficiency as long as it does not impair results accuracy. Then, the minimum number of cells per wavelength was reduced (to 7) as a compromise between the psSAR results convergence and the total mesh size (as shown in Table IV). This value applies to homogeneous regions of the domain. The number of cells per wavelength is higher in other regions to be able to represent the model details.
C. The RF Sources
The psSAR simulation in a classroom should consider the interaction between multiple EMF sources and the matter in the environment. While other sources such as smartphones and routers can be present, for simplicity, only the laptop of each student connected in a Wi-Fi network is considered.
The 2.45 GHz band was chosen for computational reasons. Using the 5 GHz band would have increased the mesh by 10-fold.
According to the IEEE 802.11-2020 Standard, the maximum delivered power is 100 mW. This value is used in the simulations. The simulated signals are continuous waves (CW) at the center of the band or CW modulated by a gaussian pulse to cover the whole band.
For the laptops, a planar antenna, the folded dipole, has been chosen, for meshing simplicity. The FR4 substrate with dielectric constant close to 4.35, loss tangent of 0.025 and 1.6 mm thickness was used. Its dimensions are 52 mm × 27 mm, the width of the feeding 100 Ω coplanar strip lines is 0.45 mm spaced 1.12 mm, and the dipole line width is also 1.12 mm. A matched 100 Ω discrete port was used in the antenna feeding. The laptop with the antenna located in the top of the cover is illustrated in Fig. 4a. The radiation pattern is omnidirectional in the horizontal plane (H-plane, as Fig. 5a shows), which is adequate for Wi-Fi applications. This arrangement also optimizes the signal distribution, since the nulls of the radiation pattern are in the vertical direction (as Fig. 5b shows). The simulated antenna radiation efficiencies are 0.9 and 0.89 when operating isolated and when integrated in the laptop, respectively. This study considered all devices operating at the same time (and in phase, due to the PBC).
Radiation pattern for the antenna when within the laptop. (a) H, horizontal and (b) E, vertical, planes.
III. THE SAR RESULTS
The psSAR averaged on 1 g of tissue (1 g-psSAR) and 10 g of tissue (10 g-psSAR) was calculated for 3 different regions of the body: the head, the back and the hands (as shown in Fig. 6a, Fig. 6b and Fig. 6c, respectively) when varying the distances between rows and the lateral distances between columns for classrooms with 7 y-o students and also for classrooms with adult students. The displacement for narrow distances is smaller to try to observe constructive interference between sources. Fig. 7 illustrate the electric field intensity in two situations. In the Fig. 7a the 7 y-0 student is alone (in this case, the PBC is substituted by the PML in the 4 directions) and in the Fig. 7b the 7 y-o student is in a classroom with 25 cm free distance between rows (12.5 cm behind the chair and 12.5 cm in front of the desk) and 40 cm free side distance between columns which implies in 0.85 m2 (d =0.85m and w =1.0m) per student, which is a compact distribution.
Child model showing the 3 regions for which the psSAR is calculated: (a) the head, (b) the back and (c) the hands.
A. Varying the distance between rows
Table V shows the simulated psSAR results in the three different regions for the adult when the distance between rows is changed and the distance between columns is fixed in 40 cm (except for the last line in which ∞ means one student alone or ∞ distance also between columns).
psSAR for the Adult model as a Function of the Distance Between Rows (and Fixed 40 cm Between Columns*)
Table VI shows the results for the child in the same situation. It is observed that the values are bellow the ICNIRP and FCC recommended limits. The maximum simulated 1 g-psSAR is observed for the back and for the minimum distance between rows. It is 0.418 mW/g, while the recommended limit is 1.6 mW/g.
psSAR for the 7 y-o child as a Function of the Distance Between Rows (and Fixed 40 cm Between Columns*)
Fig. 8a (1 g-psSAR) and Fig. 8b (10 g-psSAR) show the values for the adult model and for different distances between rows normalized to the value for one student alone. Around 10-fold increase at the head, around 26 dB increase at the back that drops to 10 dB after 20 or 25 cm and an increase oscillating between 2-to-3-fold increase at the hands are observed.
Exposure as a function of the free frontal distance between rows for an adult model in the classroom normalized to the value for one student alone: (a) 1 g-psSAR and (b) 10 g-psSAR.
Fig. 9a (1 g-psSAR) and Fig. 9b (10 g-psSAR) show the same normalized values for the 7 y-o child. Around 40-fold increase at the head and the back that drops to around 4-fold after 50 cm and around 3-fold increase at the hands are observed. The psSAR absolute and normalized values are substantially reduced as distances between rows is increased. For distances above 2.5 cm all the results remain more than 10 dB below the recommended limits and for distances above 20 cm the psSAR increase does not exceed 12-fold in all the simulated situations.
Exposure as a function of the free frontal distance between rows for a 7 y-o child in the classroom normalized to the value for one student alone: (a) 1 g-psSAR and (b) 10 g-psSAR.
B. Varying the side distance between columns
Table VII shows the simulated psSAR results in the three different regions for the adult when the side distance between columns is changed and the distance between rows is fixed in 10 cm (except for the last line in which ∞ means one student alone or ∞ distance also between rows). The maximum simulated 1 g-psSAR is observed for 2.5 cm lateral distance instead of that for the zero distance and the value is 0.08 mW/g in the head and 0.12 mW/g in the hands.
psSAR for the Adult model as a Function of the Distance Between Columns (and Fixed 10 cm Between Rows*)
Table VIII shows the results for the child in the same situation. It is observed that the psSAR is less sensitive to the lateral distance increase than to the frontal distance variation and oscillates with values much smaller than the ICNIRP and FCC recommended limits. The psSAR oscillates for the simulated distances.
psSAR for the 7 y-o Child as a Function of the Distance Between Columns (and Fixed 10 cm Between Rows*)
Fig. 10a (1 g-psSAR) and Fig. 10b (10 g-psSAR) show the values normalized to that for one student alone, for the adult model and for different distances between columns. Up to around 10-fold increase at the head and the hands and around 50-fold increase at the back are observed. Despite the decrease observed when changing the frontal distance between rows, the simulated values fluctuate and only a very small decrease is observed for the hands from 40 cm onwards.
Exposure as a function of the free lateral distance between columns (desks) for an adult model in the classroom, normalized to the value for one student alone: (a) 1 g-psSAR and (b) 10 g-psSAR.
Fig. 11a (1 g-psSAR) and Fig. 11b (10 g-psSAR) show the same normalized values for the 7 y-o child. The observed increase at the head oscillates between 6 and 10 times at the head, 3 and 5 times at the hands and 10 and 20 times at the back. Here again the values fluctuates rather than having a decrease when increasing the distance between columns (i.e. the lateral distance between desks).
Exposure as a function of the free lateral distance between columns (desks) for a 7 y-o child in the classroom, normalized to the value for one student alone: (a) 1g-psSAR and (b) 10g-psSAR.
IV. DISCUSSION
The psSAR values obtained in this study, even for the worst case, are below the safety limits recommended by the ICNIRP [2] and IEEE [14]. However, since children can stay in the classrooms for a long time, it is important to observe that long-term exposure to low levels of electromagnetic radiation should also be considered, since they can produce health effects too [1]. Among others, long time exposure can be of serious concern, due to possible biochemical effects not considered in the simulations. Further to that, other EMF sources, such as smartphones, can be used simultaneously in the classrooms and therefore should also be considered in the simulations.
The results shown in this work can contribute to a better understanding of the EMF exposures and to develop improved guidelines for the design of safer classrooms.
V. CONCLUSIONS
The results show that, generally the psSAR decreases as the distance between students’ desks increases, as expected. Increased EMF exposure in the classroom were observed when comparing with one student alone, such as up to 4-fold in the hands, 45-fold in the head and 40-fold in the back/dorsal.
Fluctuations in the psSAR plots can be due to the EMF multipath random combinations in amplitude and phase. Also, it is observed that as the distance is increased, the positions of the psSAR are displaced along the body. For instance, in the head, the psSAR is displaced from one ear to the nose and to the other ear. Simulations show that hot spots position varies, since EMF may be increased or diminished when distance is varied, depending on the EMF phase.
Overall, simulations show that if the distance between the chair and the back desk is increased, then the EMF exposure is reduced. E.g., for 5 cm distance increase, the EMF exposure in the back can be reduced around 63 percent and for 50 cm distance increase, the EMF exposure can be reduced around 90 percent.
In order to reduce the EMF health risks, the authors suggest that wireless communications should be avoided in places where people could stay for long time, such as in the classrooms, libraries, offices, homes, etc., and the devices should then be connected using cables (e. g., ethernet or fiber optic), increasing therefore the bandwidth and reducing energy consumption.
ACKNOWLEDGMENTS
The authors are grateful to Environmental Health Trust and to Prof. Paul Héroux for the support to part of this work. This study was financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - Brasil (CAPES) - Finance Code 001.
REFERENCES
-
[1] I. Belyaev, C. Blackman, K. Chamberlin, A. de Salles, S. Dasdag, C. Fernández, L. Hardell, P. Héroux, E. Kelley, K. Kesari, D. Maisch, E. Mallery-Blythe, R. L. Melnick, A. Miller, J. M. Moskowitz, W. Sun, I. Yakymenko, and International Commission on the Biological Effects of Electromagnetic Fields (ICBE-EMF), “Scientific Evidence Invalidates Health Assumptions Underlying the FCC and ICNIRP Exposure Limit Determinations for Radiofrequency Radiation: Implications for 5G,” Environmental Health, vol. 21, no. 1, pp. 92-116, 2022, DOI: 10.1186/s12940-022-00900-9. [Online]. Available: https://doi.org/10.1186/s12940-022-00900-9
» https://doi.org/10.1186/s12940-022-00900-9.» https://doi.org/10.1186/s12940-022-00900-9 -
[2] International Commission on Non-Ionizing Radiation Protection (ICNIRP), “Guidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz),” Health Physics, vol. 118, no. 5, pp. 483-524, 2020, dOI: 10.1097/HP.0000000000001210. [Online]. Available: https://journals.lww.com/10.1097/HP.0000000000001210
» https://doi.org/10.1097/HP.0000000000001210» https://journals.lww.com/10.1097/HP.0000000000001210 -
[3] Federal Communications Commission, “Proposed Changes in the Commission’s Rules Regarding Human Exposure to Radiofrequency Electromagnetic Fields; Reassessment of Federal Communications Commission Radiofrequency Exposure Limits and Policies,” Federal Communications Commission, Tech. Rep. FCC 19-126, 2019. [Online]. Available: https://docs.fcc.gov/public/attachments/fcc-19-126a1.pdf
» https://docs.fcc.gov/public/attachments/fcc-19-126a1.pdf -
[4] --, “Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields,” Federal Communications Commission, Tech. Rep. OET Bulletin 65, 1997. [Online]. Available: https://transition.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65/oet65.pdf
» https://transition.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65/oet65.pdf -
[5] B. Xu, M. Gustafsson, S. Shi, K. Zhao, Z. Ying, and S. He, “Radio Frequency Exposure Compliance of Multiple Antennas for Cellular Equipment Based on Semidefinite Relaxation,” IEEE Transactions on Electromagnetic Compatibility, vol. 61, no. 2, pp. 327-336, 2019, DOI: 10.1109/TEMC.2018.2832445. [Online]. Available: https://ieeexplore.ieee.org/document/8370684/
» https://doi.org/10.1109/TEMC.2018.2832445.» https://ieeexplore.ieee.org/document/8370684/ -
[6] L. Aberbour, O. Jawad, M. Ramdani, P. Giry, and T. Julien, “Efficient Experimental Assessment of the Specific Absorption Rate (SAR) Induced by MIMO Wireless Communication Devices; Application of Vector Near-Field Measurement System,” in 2018 IEEE Conference on Antenna Measurements & Applications (CAMA), pp. 1-4, 2018, DOI: 10.1109/CAMA.2018.8530621. [Online]. Available: https://ieeexplore.ieee.org/document/8530621/
» https://doi.org/10.1109/CAMA.2018.8530621.» https://ieeexplore.ieee.org/document/8530621/ -
[7] W. Whittow, C. Panagamuwa, B. Derat, and I. Morrow, “Correlation of Specific Absorption Rates in the Human Head Due to Multiple Independent Sources,” in 2009 Loughborough Antennas & Propagation Conference, pp. 405-408, 2009, DOI: 10.1109/LAPC.2009.5352433. [Online]. Available: http://ieeexplore.ieee.org/document/5352433/
» https://doi.org/10.1109/LAPC.2009.5352433.» http://ieeexplore.ieee.org/document/5352433/ -
[8] F. Ghasemifard, B. Xu, D. Colombi, P. Joshi, and C. Tornevik, “Assessment of Combined SAR for Low Power Radio Base Stations with Multiple Antennas,” in 2021 15th European Conference on Antennas and Propagation (EuCAP), pp. 1-4, 2021, DOI: 10.23919/EuCAP51087.2021.9411155. [Online]. Available: https://ieeexplore.ieee.org/document/9411155/
» https://doi.org/10.23919/EuCAP51087.2021.9411155.» https://ieeexplore.ieee.org/document/9411155/ -
[9] Y. Zhou, X. Zhang, and H. Li, “Assessment for the Radio Frequency Exposure Worst Case of Multiple Antennas Based on Particle Swarm Optimization,” in 2020 IEEE International Conference on Advances in Electrical Engineering and Computer Applications( AEECA), pp. 567-571, 2020, DOI: 10.1109/AEECA49918.2020.9213568. [Online]. Available: https://ieeexplore.ieee.org/document/9213568/
» https://doi.org/10.1109/AEECA49918.2020.9213568.» https://ieeexplore.ieee.org/document/9213568/ -
[10] D. T. Le and C. Van Hai, “Analyses on the Maximum Local Specific Absorption Rate of Multiple Antenna Devices in Different Measurement Planes,” in 2015 International Conference on Advanced Technologies for Communications (ATC), pp. 496-500, 2015, DOI: 10.1109/ATC.2015.7388378. [Online]. Available: https://ieeexplore.ieee.org/document/7388378/
» https://doi.org/10.1109/ATC.2015.7388378.» https://ieeexplore.ieee.org/document/7388378/ - [11] T. Kientega, E. Conil, A. Hadjem, A. Gati, E. Richalot, M.-F. Wong, O. Picon, and J. Wiart, “A New Approach to Assess the Specific Absorption Rate Induced by Multiple Plane Waves at 2.1 GHz,” in Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP), pp. 2589-2592, 2011, Electronic ISBN: 978-88-8202-074-3.
-
[12] D. T. Le, L. Hamada, S. Watanabe, and T. Onishi, “A Method in Determination of the Specific Absorption Rate of Multi-Antenna Devices,” in 2014 IEEE Antennas and Propagation Society International Symposium (APSURSI), pp. 1196-1197, 2014, DOI: 10.1109/APS.2014.6904925. [Online]. Available: https://ieeexplore.ieee.org/document/6904925
» https://doi.org/10.1109/APS.2014.6904925.» https://ieeexplore.ieee.org/document/6904925 -
[13] M. Teniou, O. Jawad, S. Pannetrat, and L. Aberbour, “A Fast and Rigorous Assessment of the Specific Absorption Rate (SAR) for MIMO Cellular Equipment Based on Vector Near-Field Measurements,” in 2020 14th European Conference on Antennas and Propagation (EuCAP), pp. 1-5, 2020, DOI: 10.23919/EuCAP48036.2020.9135506. [Online]. Available: https://ieeexplore.ieee.org/document/9135506/
» https://doi.org/10.23919/EuCAP48036.2020.9135506.» https://ieeexplore.ieee.org/document/9135506/ -
[14] “C95.1-2019 - IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz,” Institute of Electrical and Electronics Engineers (IEEE), Tech. Rep. IEEE Std C95.1-2019, 2019, dOI: 10.1109/IEEESTD.2019.8859679. [Online]. Available: https://ieeexplore.ieee.org/document/8859679/
» https://doi.org/10.1109/IEEESTD.2019.8859679» https://ieeexplore.ieee.org/document/8859679/