Abstract
This study addresses detection and analysis of incipient faults in synchronous machines by analyzing their internal or external magnetic quantities. The detection, location and classification of these faults still face challenges with current methodologies. Although the work includes analysis through finite element field calculations and experimental results, the main approach is analytical and simplified, generally using monotonic waveforms. Despite the existence of advanced procedures, such as artificial intelligence, in industry it is generally impossible to enforce faults for training or standard setting. The conclusions reached in this work can be applied in the development of guidelines for fault detection and diagnostic processes. The experimental results and those obtained through field calculations using the finite element method, together with the conclusions of studies published by the scientific community, corroborate the carried out analyses. This research aids in detecting, locating, and classifying faults in synchronous machines through magnetic quantities analysis.
Index Terms:
condition monitoring; external magnetic field; fault diagnosis; synchronous machines
I. Introduction
This article presents a simplified theoretical investigation to facilitate the identification and analysis of early-stage faults in Synchronous Generators (SGs). The methodology is applicable for monitoring the condition of the machine by detecting variations in the amplitude history of the harmonic components present in the field, flux, or magnetic induction waveforms. The amplitudes of the frequency components are obtained through Fast Fourier Transform (FFT) analysis, which is widely used. In the conventional approach, the magnetic field is measured by means of internal sensing within the machine. However, the magnetic field can also be evaluated by sensors external to the generator, which is an interesting approach since it is a non-invasive method. The study presented here is applicable to both measurement locations and can be effectively employed in the analysis of other magnetic quantities, whether measured inside or outside the electric machine. In this context, previous studies conducted on this subject have resulted in the development of equipment for the detection of incipient faults, which can be utilized in high-power synchronous generators with a high number of poles, commonly found in hydroelectric plants. The technique and its associated analysis methodology, as discussed in this paper, can also be applied to Synchronous Machines (SM) in general.
The impact of the operating point and the consequences of minor disturbances characteristic of the shaft speed of the Synchronous Generators (SG)s and/or the fundamental frequency of the grid [1] on fault detection, analysis, and typification [2], [3] will not be treated in this paper. In the case of a machine synchronized with the grid, these issues have not been sufficiently addressed in the current literature. Then, the investigation presented here assumes that the data originates from a system capable of obtaining reliable magnetic signatures with high sensitivity to high-frequency harmonic content, typically above 700 Hz. In this paper, the term "magnetic signature" is defined as the result of applying the FFT to the digitized waveforms of the time derivative of the external or internal magnetic field. The derivative nature of the signal results in an amplification of the high-frequency spectral content. It is assumed that the SG operates in a steady state, with no external disturbances.
In the specialized literature, studies on this topic predominantly focus on special-purpose machines subjected to laboratory tests under controlled conditions, in which recognition or training procedures based on the deliberate imposition of defects are employed. The results obtained under such conditions, however, are valid only for this specific machine. In contrast, the condition assessment of machines operating in real industrial environments requires methodologies that dispense training stages, since the intentional introduction of defects is impractical in industrial plants or power generation plants.
In this context, this article's main contribution is to present aspects of the behavioral trends of harmonic component amplitudes in magnetic signature spectra. The objective of this work is to address fundamental issues related to conceptualizing basic behavioral patterns of the spectral components of internal or external magnetic fields, aimed at detecting and analyzing incipient faults. Consequently, beyond fostering relevant discussions in machine condition monitoring, the conclusions support the development of guidelines for detecting, localizing, and classifying incipient faults in synchronous machines (SMs). The article addresses different types of defects, providing an integrated and unified view of the subject. The developments presented are predominantly theoretical and are, in some cases, corroborated by numerical simulations or experimental results.
The article is organized into well-defined stages. Initially, the topic is contextualized within the scope of the existing literature, pointing out relevant references. This literature review is not intended to be exhaustive; rather, it is limited to cite studies that succinctly describe the evolution of international research on the subject - hence the inclusion of works related to induction machines - as well as those that provide theoretical support for contributions closely related to the content proposed herein, including aspects arising from their associations. Subsequently, it is qualitatively demonstrated that the behaviors of magnetic signatures obtained in the air-gap region and externally to the machine, through measurements on an electrical generator, exhibit a high degree of similarity. In a brief section, some aspects of the hardware suitable for monitoring high-power SGs are addressed.
In the following section, within the context of synchronous machine monitoring, the most elementary theoretical aspects associated with the rotating fields produced by the stator and rotor windings are addressed. To support some aspects of the proposed approach, electromagnetic field simulations based on the two-dimensional finite element method (2D FEM) are employed. This establishes the theoretical basis for understanding the behavior of the spectral components of the magnetic field and confirms that the fundamental frequency component of the system corresponds to the mechanical rotational frequency of the machine. Once this aspect is validated, its influence on the frequency spectra is considered in modulation processes. To address this issue, simple analytical models with monotonic characteristics are employed, facilitating the distinction between different fault types through visual assessments of magnetic signatures.
The proposed approach is also supported by the result of a case study involving a fault type that is difficult to detect, locate, and classify through the analysis of anomalies in the magnetic fields external to the machine, as well as by references to experimental results reported in the literature. Finally, prior to the discussion of the results and the presentation of the conclusions, the article includes a dedicated section outlining relevant characteristics to be considered in the development or use of equipment intended for synchronous machine monitoring.
II. Brief Overview and Contextualization of Synchronous Machine Monitoring
This section provides brief contextualization. Studies addressing advanced techniques and developments, such as those employing data science tools, are intentionally not discussed.
Synchronous generators are one of the most important components of power plants and they are generally associated with a system that detects incipient faults for its protection. A traditional, standardized example is real-time monitoring of mechanical vibration using accelerometers and proximeters [4]. This widely used system is invasive, relatively expensive to install and requires machine downtime. However, machine condition assessment using this strategy is already a well-known and standardized procedure, which is not the case of using machine external fields to monitor its condition. Although one of the most important quantities in the operation of a SG is the magnetic field (the converted energy derives from the interaction between the induction and magnetic field quantities, mainly in the air gap region), there are few systems that monitor magnetic quantities available commercially. An example of a commercial system that is widely used in SGs is the equipment from Iris Power company, which monitors changes of the magnetic flux amplitudes originating from the field windings in the air gap region. Its ability to detect faults performance in the rotor windings have been proven. Even though this technique presents some drawbacks because its operation requires to place the sensor inside the generator, leading consequently to stopping the machine and to raise the costs associated with the entire installation process. Nevertheless, it has the intrinsic characteristic of avoiding false positives. Due mainly to its simplicity and effectiveness in assessing faults, this methodology has been readily accepted by the maintenance sector of electricity generating companies. Several studies have been published in the literature on this type of sensing strategy/technique [5]- [11].
Other techniques that have also reported success in detecting faults are proposed in the literature, such as Electrical Signature Analyses (ESA) by monitoring the voltage and/or current of the field and/or armature windings [12], [13]. In high-power and/or high-voltage generators synchronized to the grid, methodologies based on measuring stator voltage or current can be difficult to use and may not be as effective as expected. When current or voltage transducers are required, the spectral content of interest can be inherently filtered out by these devices. Regarding non-invasive methodologies for detecting faults in synchronous machines, recent approaches and studies can be found in the literature, such as in [5], [14]-[18]. In the context of non-invasive methods for monitoring machine magnetic quantities, operating systems for monitoring the external magnetic field of synchronous machines in large industrial plants can still be considered rare today. The maintenance area of power generation plants is unaware of the machine evaluation capabilities using this method, as the analysis is more complex than the methodology presented in [6], for example. In addition, the methodology of monitoring the external magnetic field easily generates false positives [2] and still requires considerable effort to standardize.
The study of the external magnetic field in the coil heads region (fields from end-winding) was first recorded in the 1960s [19] and that of the magnetic field external to the machine housing in the 1970s [7], [20]. The first studies have reported measurements and numerical simulations of the behavior of the field around machines [21]-[23]. The use of external magnetic field monitoring has evolved more in asynchronous motors because it is easier to obtain information due to the nature of the rotating electrical machine, the possibility of verifying it by analyzing the waveforms of the supply current and the importance of its application in industry as a mechanical driving force. For example, the association of slip with the fault influence leads to the appearance of components in the frequency spectrum that make it easier to detect faults when analyzing the spectral composition (magnetic signature) of the electric current or the internal/external magnetic field. However, the theory of magnetic signature monitoring for the asynchronous machine is more complex than that of the SM.
In the SM, the frequencies of the frequency spectrum components are fixed, which is not the case in the asynchronous machine. For induction motors, the probable beginning use of the external magnetic field analysis technique for fault detection is related to the investigations reported in [24]-[26]. This method has gained greater visibility in the last 20 years [5], [27]-[31]. There are also studies reporting the superiority of fault detection using external magnetic flux compared to current monitoring [5]. However, the spectral compositions obtained by both techniques, using the current or the external field, are similar. However, more systematic and fair research is still needed, as the amplitudes of the measured quantities are different and the hardware used also has different characteristics. Another reason for applying the method using external fields to induction motors is due to the size of the machines themselves, which generally have a relatively smaller poles number than large synchronous generators, requiring smaller hardware capacities than those used in machines with many poles and requiring fewer sensors.
There is a lot of research and development on equipment for asynchronous machines using the external magnetic field analysis technique, but there are comparatively few studies on fault detection in SM using this technique. One of the first works is presented in [32], which points out the possibility of detecting electrical faults in the stator and rotor of wound rotor synchronous machines. Reference [32] presents also an analytical calculation approach, obtaining an expression for the magnetic field in air gap as a function of some SG construction parameters, both for the healthy machine and with the inclusion of some defects. The faults studied are short-circuits in the stator or rotor windings and breakage of damping bars. Equations based on the fundamental electrical frequency and machine construction data to determine the possible fault frequencies are proposed for each type of studied fault. In the analysis of the experimental results, the inclusion of the stator turns short-circuit fault causes changes in the amplitudes of the electrical fundamental and its third harmonic, as well as two frequencies related to the stator slots number. The authors also report that the spectral result depends on the external position of the sensor. There is no information on the percentage of the number of short-circuited turns, or whether the fault was a reduction in turns (without a short-circuit), or whether the machine was operating as a generator, or whether it was synchronized to the grid, or whether the operating point was kept constant. It is known that the fault can change the operating point in such a way as to make the detection and analysis process more difficult [2]. For the other type of fault analyzed in [32], a rotor fault with a short-circuit of 12.5% of the rotor winding, the frequency spectrum became denser according to the authors. The frequency component of the electrical fundamental divided by the pole pairs number appears. The behavior of the spectrum for this type of defect is predicted by the equation proposed by the authors. The authors rightly point to this streak as an indicator of a fault in the rotor (it is the rotation frequency and will be discussed later). Teams from the University of Béthune (Laboratoire Systèmes Electrotechniques et Environnement) and the Université Lille Nord of France have published several relevant works on this subject, maintaining the same approach and analysis methodology for 4-pole machines. Reference [33] adds the mechanical vibration technique to the analysis, suggesting that the frequency of 25 Hz (electrical fundamental frequency divided by the pole pairs number) comes from the magnetic force of attraction between the stator and rotor.
Almost simultaneously with the publication of [32], another group of researchers published studies [34], [35] on the behavior of the external magnetic field of SMs. Initially, they presented an alternative method for calculating the external field of permanent magnet motors using Spherical Harmonics associated with Fourier series expansions. With these techniques, the external magnetic field is calculated as a function of the space surrounding the machine. Spherical or Cylindrical Harmonics are the theoretical basis applied in patent [36] developed by the same team. The patent describes a system and its method for monitoring and diagnosing electrical machines by means of the external magnetic field or induction, using magnetometers as sensors. Diagnosis is carried out by comparing measured values of magnetic induction or magnetic field with expected values at one or more points around the machine. Another relevant investigation can be found in [37], which proposes a procedure for detecting, locating and quantifying faults. The method is based on the theory of inverse problems and is somewhat like references [34], [35].
At GRUCAD laboratory of the Federal University of Santa Catarina, research in techniques of detecting faults in electrical machines using external magnetic field was carried out by studies and developments of systems to obtain magnetic field waveforms inside steel sheets and systems for measuring currents using Rogowski's coil [38]-[40]. At the same time, the technique was applied to detect faults in three-phase induction motor rotors, comparing results with measurements of the natural electromechanical frequency spectra of machine from accelerometers [41]. This research has evolved to its application in SGs, resulting in the implementation of two pilot devices, installed in 2015 in a 305 MVA, 56-pole generator at a hydroelectric power plant, and in another 131 MW, 2-pole generator at a thermoelectric power plant. Subsequently, two others industrial equipments were installed in two 305 MVA generators at the same hydroelectric plant. This represents a milestone in the monitoring of high-power SGs, as, to the best of the authors’ knowledge, no similar equipment employing this technique had been installed up to that time. Reference [3] covers fault detection analysis and some details of the hardware of the equipment developed in its first version, including approaches using MEF-2D. A successful detection of an incipient fault in one of the generators monitored at the hydroelectric plant is presented in [2], [3]. They contain some information from a technical report presented at an applied engineering congress of the Brazilian electrical system. The incipient fault in the 305 MVA 56-pole SG occurred in 2018 and was detected by the equipment in its prototype version. To the best of the authors’ knowledge, this is the first reported case of detecting an incipient fault in a large generator at a hydroelectric power plant using external magnetic field anomaly monitoring. The external magnetic field changes initially indicating shaft displacement defect in one part of the machine. The initial hypothesis being that there was a displacement defect in one part of the stator. This hypothesis was based on the knowledge and numerical tools developed at that time. At the same time, a mechanical vibration system was also installed in the generator and has detected a certain degree of anomaly, but not in a sufficiently reliable and conclusive way to stop the machine for maintenance (stopping the machine involves high economic costs). After, during a programmed maintenance process, shaft displacement and rotor unbalance were discovered. Currently, to improve the methodology for monitoring the condition of synchronous generators, theoretical developments, both for change detection systems with low computational cost to be implemented in equipment [2] and algorithms for expert data analysis are carried out. Reference [42] presents the latest version of the equipment installed in the last two SG at the hydroelectric plant. In the context of the methodologies developed at GRUCAD, this article presents the theoretical bases of the developments implemented in the software for detecting, analyzing and diagnosing faults at an early stage by monitoring anomalies in the external magnetic field of SMs in general.
Reference [3] presents a further development of the conclusions reached in [13], [43], [44], and showed that in real machines, due to small asymmetries of magnetic, electrical and/or mechanical/structural origin, the fundamental frequency (for the analysis of faults in rotating machines) of the external magnetic field (or in the air gap) is naturally the mechanical rotation frequency, and not, as commonly adopted, the fundamental frequency of the armature currents (electrical fundamental frequency). According to [43], until its publication in 2008, the presence of additional frequency components below the electrical fundamental frequency had not been widely reported when there are structural asymmetries in the machine. Reference [43] uses the experimental strategy of analyzing the stator current, while reference [13] uses signals obtained from a search coil placed on the SM rotor. These additional frequencies are called sub-harmonics in [13], [43]. In other words, from the point of view of detecting incipient faults using electromagnetic quantities, references [13] and [43] analyze the machine as if the fundamental of the system is still the electrical fundamental. As already mentioned, reference [33] also employs a similar approach and justifies the appearance of the mechanical rotation frequency due to mechanical vibration caused by electromechanical forces. However, reference [43] states that the existence of these frequencies is caused by small asymmetries in the stator windings, and does not provide a clear and evident additional explanation. In fact, these components are direct harmonics of the fundamental of mechanical rotation [3], a fact not sufficiently demonstrated in [13], [43]. However, as [13], [43] rightly states, these components are prime candidates for detecting rotor faults. Also, according to [13], [43], these components must be present in the frequency spectra for fault detection to be possible, and they state that they are always present in real machines, the same conclusion being reached in [3], [44], [45]. In [43] an important conclusion has been reached. In this paper the authors showed that the 30 Hz component (mechanical rotation frequency of the machine studied in [43]) is a candidate for detecting broken bars (damping windings) in the rotor of SMs, and that its amplitude is not affected by abnormal operating conditions, such as unbalanced supply voltages.
The approach in [2], [3], [42], [44], [45] follows a somewhat different theoretical and experimental methodological basis to some references. There are some differences between many works presented in the literature on fault detection in rotating electrical machines. Among them, comparisons between instantaneous spectra with and without the presence of a fault are commonly used in literature. In a different way, analysis of the amplitudes evolution in sequentially manner obtained from frequency spectra (called continued magnetic signature or continuous condition monitoring in [2]) is not commonly used in the research presented in the literature. For various reasons ([2] presents some of them), the approach used in [2], [42], [45] is to analyze the harmonic amplitudes behavior in sequentially updated and stored histories from the external magnetic field time derivative waveforms. There are changes in the frequency spectra due to the magnetic flux distribution inside the machine depending on the operating point. In laboratory tests, it was noted that small variations in the machine temperature also influence the composition of the frequency spectra. The study, methodology and techniques developed at GRUCAD are not yet suitable for dynamic transients, especially for rapid and significant disturbances due to speed and/or load variations.
III. Harmonic Content from Internal and External Measurements
To illustrate the typical frequency spectra behavior of the magnetic field inside and outside the machine, measurements were carried out in the laboratory on the same SM (8 poles, Y+N, 380 V, 10 kVA, with 72 slots in the stator which can operate at 50 Hz or 60 Hz) used in [2], [42]. This machine is part of a bench specially built for the inclusion of incipient faults of electrical or mechanical origin, mechanically driven by a primary direct current machine. Fig. 1 shows harmonic spectra of the time derivative waveforms of the magnetic flux obtained from search-coil sensors around a stator tooth and outside the housing, for the healthy SG synchronized to the grid at the 7 kVA and 0.8 inductive power factor. The harmonics amplitudes are relative to the electrical fundamental amplitude at 60 Hz. The windowing used in the FFT process is rectangular (it is also applied in all the other FFT analysis in this paper). As the same hardware was used to obtain both sensor signals, the background noise levels of the two signals are close. Although the amplitudes are relative to the electrical fundamental amplitude, the harmonic amplitudes above the electrical fundamental obtained from the external measurement are generally lower than the internal ones, which is largely due to the housing electromagnetic attenuation. The orders of the components of interest are all harmonics of the mechanical rotation fundamental. The harmonic content compositions are also similar. However, the external content contains some spurious rays coming from the magnetic field ambient. In analysis processes applied to SMs, these spurious amplitudes are removed by means of an appropriate tracking algorithm keeping only the harmonic content of interest [2]. This example shows that the external spectral content is like the internal spectral content, without any significant loss of information. So far, a context of methodologies for detecting and analyzing incipient faults in SM has been presented. The following section discusses some hardware aspects, while the main contributions of this article are presented subsequently.
IV. Hardware Considerations for SG Monitoring
Although the focus of this article is not on the hardware aspects, for equipment implementations it is important to know that the fundamental frequency of the system is mechanical speed. Therefore, from the perspective of nominal machine speed values, an increase in the number of SM poles leads to a corresponding increase in the degree of hardware quality and capacity requirements. In machines with a low number of poles, waveform analysis is facilitated by a reduction in the number of frequency components of interest, which results in a smaller amount of data for storage and analysis. When the rotation frequency is low (i.e., when the machine has a high number of poles), it is essential to define the spectral resolution with precision (e.g., for a rotation speed of 120 rpm, the spectral resolution must be significantly lower than 2 Hz). Additionally, the sampling rate of the digitization process must be high (e.g., higher than 500 kHz, given that the range of high-frequency components is also crucial for machine analysis, as will be discussed subsequently). These two factors result in increased hardware costs and necessitate the provision of larger storage and processing capacities. In the context of monitoring the condition of electrical machines through the external magnetic field, the amplitude resolution of the A/D converter represents a critical factor, given the very low amplitude of the harmonic components in the signal.
In general, the criticality and quality of the hardware exhibit a direct correlation with the increase of machine poles and an inverse correlation with the decrease of machine housing thickness. The thinner the machine house thickness, the less the internal magnetic field will be attenuated to the external regions close to the machine. Regarding the positioning and sensitivity of sensors and the capacity of the hardware, fields originating from coil heads or busbars may present a challenge in the detection and analysis of specific faults type. This is because the high amplitude of the electrical fundamental frequency in such cases can make it difficult for the acquisition of information present in the low-amplitude spectral content. In many cases, the amplitudes of the fundamental electrical frequency and its odd harmonics are greater than that of other components of the frequency spectrum. This phenomenon can be observed in the frequency spectra of machines in industrial environments, as presented in [2], [42]. The sensors positioning near the highest amplitudes of the electrical fundamental can result in a reduction in sensitivity to the spectral content of interest. Technical details regarding an initial version of an external magnetic field measurement system can be seen in [3] and a subsequent industrial version in [42]. This present article does not discuss hardware issues in depth. However, it is essential to highlight that the measured waveforms quality is key to the successful application of methodologies for the detection, location, and typification of incipient faults proposed here.
V. Theoretical Basis of Spectral Component Behaviors
For the detection of incipient faults in SMs, traditional techniques based on statistical methods [2], as well as approaches based on regression techniques and artificial intelligence [46], have been employed. However, with respect to the classification and localization of different fault types, such techniques, when used in isolation, exhibit inherent limitations or rely on extensive training procedures under multiple fault scenarios.
As previously mentioned, the implementation of such training becomes impractical for machines operating in industrial environments, since the deliberate introduction of faults is not feasible. Alternatively, computational modeling based on field calculations using the Finite Element Method (FEM) may be employed to identify signatures associated with stator and field winding faults [47], as well as static eccentricities [48]. Effectively, an alternative approach would require the availability of a large and representative database of real fault cases, which constitutes a fundamental prerequisite for the effective application of advanced data science tools - a condition that may take more than a decade to be achieved.
Within this context, the present work aims to provide the research community with the essential theoretical foundations associated with harmonic spectrum behavior, together with an analysis of the differential sensitivity of sensors distributed around the machine, with the purpose of identifying generalized patterns of spectral alterations that are characteristic of each investigated fault type. Thus, specifically as the major contribution, basic guidelines are suggested for choosing candidate spectral components and/or frequency regions suitable for detecting incipient faults in monitoring conditions that can facilitate and provide indications for detecting, typifying, and locating the incipient fault in a machine. In this context, the SM is seen here as a signal emitter (signal generator) of magnetic fields to internal or external media. The in-depth investigation is based on the methodology and the analysis results developed and presented mainly in [2], [42], [44], with some information highlighted again here. This approach is simple and succinct enough to guide and provide an understanding of the changes observed in frequency spectra used to detect and analyze incipient faults in real machines.
A. Fundamental component of SM: the mechanical rotation frequency and rotor fault detection
Although the waveforms in SMs are not sinusoidal (e.g., there are windings distributed in slots which generate harmonics - see Fig. 2), sinusoidal waveforms will preferably be used to simplify the analysis and understanding of the spectrum behavior through the amplitudes of the harmonic components that constitute the SMs magnetic signatures. The aim of this approach is to make it easier to understand the complexity of frequency spectra due to non-linearities and multivariable composition. For a real SM analysis, complex tools are required from analytical approaches such as those presented in [13], [33], [35], [43], or numerical simulations [37], [44], or analysis of experimental data with advanced tools such as artificial intelligence, machine learning, deep learning, prediction, and identification. First of all, the physical reason for the appearance in the frequency spectra of the magnetic field (or waveforms of the magnetic field time derivative) of the mechanical rotation fundamental frequency and their harmonics is emphasized. As already mentioned, the appearance of the mechanical rotation fundamental frequency could be attributed to the magnetic induction radial component in the air gap, which induces a force between the rotor and the stator [33]. These induced forces, if based on the electrical fundamental of the machine, are function of the flux density square in the air gap, which would correspond to an induced force fundamental twice the electrical fundamental frequency of the air gap flux density and should excite the natural mechanical vibration modes of the machine [49]. Other researchers have noted, experimentally and through analytical deductions, that the mechanical rotation frequency is observable in the frequency spectrum when faults are present [13], [32], [43], [44].
In additions to induced eddy currents (e.g. currents induced inside the magnetic core sheets), a healthy rotor excitation SM has two magnetic field sources: one in the rotor (1) and another in the stator (2). In (1) and (2), H rp and H sp are the magnetic fields per pole generated, respectively, by the electrical currents in the rotor I r and the stator i s (t). In these equations, N r and N s are the number of windings turns per rotor and stator pole, respectively. In simplified terms, l r and l s are the equivalent mean magnetic paths per pole of the rotor and stator fields, respectively. The magnetic field measured by an external or internal sensor (in the air gap) is composed by the two magnetic fields coming from the stator and rotor currents (and from eddy current fields, which are present, for example, in the damping windings [32] or in supporting hardware, if taken into account) and other fields associated with faults (for example, fields generated by currents induced in stator sheets shorts). Each magnetic field of the main sources (rotor and stator) can be changed by: i) variations in the current pattern (or its distribution) and/or ii) its magnetic path due to variations in the air gap or changes in the local magnetic characteristics of ferromagnetic materials. Neglecting the components of the leaked magnetic fields and those inside the ferromagnetic core materials, which are relatively smaller than those in the air gap, the magnetic field of each main source can be approximated by those in the air gap. Thus, the magnetic inductions in the air gap per pole generated by the rotor B rp and the stator B sp are given by (3) and (4), respectively. The resulting induction per pole in the air gap B pnet can be given by (5) [49]. The modulus of the resulting induction per pole in the air gap B pnet can be calculated using the parallelogram rule (6), where δ rs is the angle between the two vectors B rp and B sp . This is valid only for sinusoidal and monotonic waveform. For waveforms with harmonic content, the resulting induction in the air gap can be obtained using computational methods such as FEM.
In an ideal machine (perfectly healthy and homogeneous), the existence of slots and distributed windings, pole salience, and the non-linearity of ferromagnetic materials cause only the appearance of the odd harmonic content of the electrical fundamental. Thus, in general, the amplitude variations of the odd content in the SM operation are subject to the operating point of the machine through the degree of saturation of the magnetic cores and/or the amplitude of the electric current in the stator, for instance. But if all the waveforms involved were sinusoidal (monotonic), only the fundamental electrical frequency component in the magnetic field frequency spectrum will be present. To show why components appear in the frequency spectrum in addition to the odd content of the electrical fundamental, and to facilitate the theoretical approach, the references [3], [44] considered a waveform of the hypothetical magnetic induction B r (t) generated by the rotor poles at a fixed point in the air gap for an 8-pole no-load SM. For the 8-pole SM, if a defect that causes an asymmetry in the induction waveform is imposed, such as a reduction in the number of active turns in one of the rotor poles, the waveform will be periodic every four electrical cycles, with period T m given by (7), where p is the number of pole pairs in the machine. The relationship between the mechanical frequency f m and the electrical frequency f e is given by (8).
According to the Fourier Series theory, the mechanical rotation period T m becomes the fundamental period of the system, and not the electrical period T e as is commonly considered. This generates the spectral component of the mechanical rotation and its even and odd harmonics (because there will be poles with different magnetic fluxes from the others, with fluxes being redistributed in an inhomogeneous way between adjacent poles). This is why in all real machines there is harmonic content related to mechanical rotation, because there is no perfect electromagnetic homogeneity throughout the machine, even when considered healthy. Although magnetic flux is conservative throughout the machine, there may be points, or regions, where the magnetic flux distribution in the machine will cause a local continuous component. This fact was explored in the distribution of the field outside the machine by [35] and [37]. The methodology of [35] and [37] is not explored in this article due to the nature of the used sensors [3]. In the case of analysis based on experimental data, failure to detect the fundamental mechanical rotation and its harmonics is due to the low sensitivity/quality of the hardware used. Therefore, one way of qualitatively evaluating the hardware used for fault detection is to apply this requirement, i.e., the ability to detect the frequency component of mechanical rotation and its harmonics in a healthy SM. In all the tested SM (in the laboratory and in power generation plants), this harmonic content was present, without exception.
To find a perfect machine representation for the development of the studies, the 2D FEM approach was initially used to illustrate that the mechanical rotation frequency f m becomes the system fundamental frequency [3]. The simulation results presented here improved in quality compared to those published in [3] by increasing the simulation spectral resolution. Therefore, it was necessary to spend more time on the simulation, resulting in computational demands. The complexity of improving the calculations performance and accuracy increases with the reduction in the calculation time steps and the angle of displacement between the fixed and moving parts, as well as with the search for a refined finite element mesh. Obviously, there are imperfections relating to the FEM mesh and typical numerical problems, such as numerical truncation errors. Due to these difficulties inherent in the FEM and its imperfections, background noise in the FFT analysis appears. This background noise has a typical level in the simulations carried out of around −90 dB, as observed in the simulated frequency spectra presented later in this section, in relation to the amplitude of the electrical fundamental (in absolute terms, around thirty thousand times smaller than the amplitude of the fundamental).. The background noise from the numerical simulations is considerably higher than the experimental one using the hardware of the equipment employed in [3], [42]. The experimental background noise is around −120 dB (see Fig. 1). Moreover, the machine needs to be fully simulated so that the defect is well represented in the FFT spectral content of the FFT analysis. In the FEM simulation, the sensor in the air gap region (a probe coil wound on a tooth) is shown in detail in Fig. 2(a). The magnetic flux patterns for the machine operating at no load with and without a fault are shown in Fig. 2(b) and Fig. 2(c), respectively. The simulated fault is the loss of all the coil of a rotor pole.
FEM simulation results: (a) probe in the stator tooth; magnetic flux distribution (b) with fault and (c) without fault.
Fig. 3 shows the induced voltage waveforms in the probe coil and Fig. 4 shows the frequency spectra for the healthy 8-pole SM and without excitation in one of the rotor poles. In the FEM, the core materials were represented by their initial magnetization curves. Visually, the waveform obtained from the sensor for the healthy machine has full-wave and half-wave symmetries, which should only result in the presence of the electrical fundamental and its odd harmonics. As can be seen in Fig. 4, the numerical simulation imperfections also cause the mechanical rotation fundamental and its harmonic content to appear in the simulation of the healthy machine. The waveform of the machine with a rotor defect clearly has a mechanical rotation fundamental of 12.5 Hz (relative to four electrical cycles). In addition to the background noise inherent to the numerical simulation, considerable spectral leakage can also be observed in the simulated frequency spectra.
Induced voltage waveforms of the stator-tooth probe coil for the generator (a) with fault and (b) without fault.
The harmonic components of the mechanical rotation fundamental f m follow the pattern of spectral components defined by (9) [43], which are candidates for fault detection frequencies f d in SMs (k = 1, 2, 3, ...). This pattern was also found in [3] under other theoretical and experimental approaches. Under the aspect of fault detection, the study in [43] was developed on synchronous motors with asymmetries, where the authors present an analytical model of the magnetic induction in the air gap as a function of the permeance density, in a similar way as in [12], [13], [32], [33]. The authors of [43] concluded that when there is an eccentricity on the shaft, frequency components f d [k], which obey (9), can be detected in the armature current waveforms. In the results presented in [43] for the SM operating as a healthy motor, the mechanical rotation fundamental and its harmonics did not appear, but the 5th and 7th harmonic components of the electrical fundamental did. As mentioned, this is the typical behavior of machines due to phenomena such as the non-linearity of ferromagnetic materials and the non-sinusoidal waveforms of the distributed windings (odd harmonic content of the electrical fundamental). Using another approach concerning the SM waveform spectra composition, some of the conclusions of [43] are similar to those obtained later in [3], [42], [44], corroborating the validation of the methodologies used to address the issue. Thus, this simple approach presented here, shows that for machines considered as healthy, even with negligible asymmetries in the rotating field in the air gap, the fundamental frequency of rotation and its harmonics are present in the frequency spectra of the magnetic fields, in addition to the electrical ones (for p = 1, the electrical and mechanical rotation frequencies match [44]).
When applying the fault detection strategy using sensors located at fixed points outside the machine (or inside the machine, as in Fig. 2(a)), the magnetic field produced by the stator windings contains only the electrical fundamental frequency and its odd content, either provided by the machine itself nature and/or by defects; i.e. the waveforms measured/captured are the same/repeated every electrical cycle. With this fixed sensor positioning referenced to the stator, the mechanical fundamental frequency and its harmonic content are only detected due to the imperfection of the rotating magnetic field generated by the rotor. Some conclusions can be drawn with regard to the detection, location and classification of faults: i) from an initial point of view, only rotor faults could be detected; ii) rotor faults are easily detected, as the mechanical fundamental and its harmonic content are altered significantly with the severity of the fault [3]; iii) notably, the mechanical fundamental and its harmonic content are the most altered for rotor faults [3]; iv) to detect rotor faults, it is sufficient to monitor the low frequency components (for p > 1, these are the frequencies below the electrical fundamental) [3]; v) to detect rotor faults, a single sensor is sufficient [3]; vi) to ensure that the fault is in the rotor, more sensors must be used, and the magnetic signatures coming from each sensor are sensitized in a similar way; vi) if a sensor, or part of the sensors, show variations in magnetic signatures that differ from the same pattern, there is a high probability that the fault is not in the rotor excitation/poles; the origin may be from shaft displacement and/or mechanical vibration, or that the location of the sensor gives too much priority to the electrical harmonic content (or the electrical fundamental: e. g., when the sensor is positioned close to the machine bus). In addition to these general guidelines, some characteristics must be taken into account, such as the fact that the rotor magnetic circuit seen by stator is not perfectly homogeneous (such as the differences caused by magnetic anisotropy and/or air gap variations due to inherent and typical vibrations, negligible shaft displacements or constructive inhomogeneities in the rotor poles). Thus, a fault located in the stator can interact with the inhomogeneity of the rotating part, whether severe or slight, resulting in the detecting stator faults possibility. In this case of a stator fault, a sensor (or part of the sensors with similar patterns) will pick up changes in magnetic signatures, i.e., not all the sensors positioned on the circumference of the machine will show the same pattern of changes. Despite this, it is difficult to detect faults in the stator, because the inhomogeneity of the rotating magnetic circuit of a considered healthy rotor has relatively greater effects on the waveforms of the fixed sensors in the stator than disturbances caused by incipient faults in the stator, which by their nature influence the odd components of the electrical fundamental.
However, if there were no imperfections on the rotor, there would be no mechanical rotation fundamental and its harmonic content, making a considerable range of stator fault detection possibilities impossible. In this way, the behavior in patterns of changes contributes to the process of locating the incipient fault (whether it is a rotor or stator fault). For example, if the fault modifies the electromagnetic behavior of the rotor itself, the magnetic signatures coming from all the sensors must necessarily be altered in a similar way, showing the same pattern. These issues will be revisited and explored in greater depth throughout the article. Similarly, despite physical implementation difficulties, if the sensors are placed on the rotor (the sensors would be rotating at synchronous speed), stator faults would be easily detected, as shown by the results presented in [13].
B. The “pseudo-rotating field” generated by the stator windings currents in the matter of fault detection
As is usually the case in real machines, it is assumed that a defect in slots or stator windings will cause a change in one of the poles of a stator phase, in a pair of stator poles, or in a region comprising on a polar pitch pair and its multiples. In addition, the stator winding currents do not actually generate a rotating field so that the same physical pole travels around the entire circumference of the air gap (or the stator), as is the case with the rotor poles. This resulting field generated by the stator winding currents is referred to here as the “pseudo-rotating field”. For example, for p= 2, the amplitude of one of the two north poles of the resulting stator field will travel 90º around the circumference of the air gap, repeating the same path every electrical cycle, i.e., the “pseudo-rotating field” always travels the same arc in the air gap, repeating itself every electrical cycle. Thus, at a point on the stator, the pseudo-rotating field varies its amplitude over time, alternating north and south polarities equally with each electrical cycle, providing there no disturbances in the stator electrical currents and considering a perfect rotor. It should be noted that if and only if the air gap and rotor magnetic circuit are homogeneous, the configuration of the magnetic field generated by the stator windings is the same in every electrical cycle (a sensor placed at a fixed point on the stator will be influenced by the “stator pseudo-rotating magnetic field” in the same way every electrical cycle). The main consequence is that imperfections in the stator do not in themselves cause the mechanical rotation fundamental frequency and its harmonics to appear in waveforms captured by a sensor fixed to the stator (referenced to the stator). In another way of positioning the sensor and in a machine where the magnetic field resulting from the stator has some imperfection, if the sensor were placed in the rotating part (rotor), the waveform obtained through the sensor will have the mechanical rotation fundamental frequency and its harmonic content (as already mentioned, reference [13] made use of this characteristic by positioning a sensor in the rotor). For sensors referenced to the stator, this behavior of the “pseudo-rotating field” has consequences for incipient fault detection processes: in principle, changes in the measured waveforms will only occur in the amplitude of the electrical fundamental and its odd harmonic content. Changes in the amplitude of the electrical fundamental and its odd harmonic content can also occur due to variations in the operating point or the temperature, making analysis difficult and, above all, facilitating the occurrence of false positives.
Under the above considerations, an incipient fault on a rotor pole is easy to detect, as it causes the presence of the mechanical rotation frequency and its harmonics. However, an incipient fault in the stator generally causes changes that are difficult to detect. It should also be borne in mind that the amplitudes of the electrical fundamental and its odd harmonics, up to a certain frequency order, naturally tend to have relatively higher amplitudes than the other components (see Fig. 1). An incipient defect in the stator tends to contribute changes in the amplitudes of this odd electrical harmonic content, which are almost imperceptible compared to the changes that typically come from a synchronous generator with a change in the load point and/or its terminal voltage [2]. To overcome these difficulties when using sensors referenced to the stator, the amplitude modulation theory is applied (phenomenon that typically occurs in an electrical machine) along with the characteristic that the rotating field generated by the rotor is imperfect, for various reasons of constructive origin and the anisotropic characteristics of the materials used (the magnetic circuit of the rotor is not perfectly homogeneous and rotates). Although it was not yet clear at the time that the fundamental frequency of the machine for fault detection was that of mechanical rotation, reference [43] rightly stated that the rotor imperfections make SM fault detection possible. These facts are difficult to prove experimentally, as no perfectly homogeneous machine exists and there are always imperfections present in the rotating field generated by the rotor. One option for the investigation can be performed through numerical FEM simulations, which require high processing capacity, simulation time and highly precise and complex software (the entire machine must be simulated), with calculation and displacement steps so small that it may not be a viable solution. Therefore, sinusoidal waveforms are used here in the analysis. This facilitates the development of the modulation processes involved in the machine, using a simple and comprehensible analytical approach.
VI. Modulation and Fault Detection Process
Even though the adopted modeling approach is simplified, the results presented in the following sections prove to be rich in information, including those arising from modulation processes based on sinusoidal waveforms. An effort is made to analyze and discuss these results to the extent possible, without excessive depth, since the investigation relies, in most cases, on simplified (sinusoidal) waveforms and therefore does not fully capture the complexity of real operating conditions. Accordingly, the analysis of the results is conducted predominantly in a qualitative and visual manner, focusing on the overall behavior of the information associated with harmonic content formation, rather than on detailed quantitative assessments.
Indeed, excessively detailed analyses could lead to inconsistencies and potentially misleading conclusions, given the inherently nonlinear behavior of the machine and the presence of significantly more complex waveforms, which further complicate the interpretation of modulation processes. Moreover, as each machine exhibits distinct characteristics and waveform patterns, addressing highly specific details would hinder the objective of focusing on fundamental and general aspects capable of supporting guidelines for fault detection and diagnosis in condition monitoring applications.
The healthy operating condition is repeatedly presented in the figures as a reference, with the aim of facilitating the visualization of spectral changes, highlighting the differences among operating conditions, and indicating the frequency regions in which the most significant variations are concentrated for each investigated case. Each investigated case presents the waveforms of the analyzed quantities and the corresponding FFT analysis of the magnetic induction waveform, preceded by an analytical modeling of the underlying phenomenon.
A. Modulation process involving rotor rotating field and stator characteristics
In this modeling, the simplifications are taken into account, and the reference is fixed at the stator. It is assumed that the rotor poles produce a waveform of the magnetomotive force F r (healthy) (γ,t) traveling in the air gap, which at a point on the stator is a sinusoidal waveform (10). In this equation, the amplitudes of all the poles are the same (healthy machine), the lag angle α m is referenced to any point on the air gap where the peak F rp of the magnetomotive force of a rotor pole occurs. In order to obtain the waveform of the induction in the air gap, the permeance density of the healthy stator P s (healthy) (γ,t) is defined by (11), where γ is an angle related to the center of a stator tooth, P sm is the mean value portion of the stator permeance density and P ssh (γ,t) is the variable portion of the stator permeance density due to the slots, given by (12), where α ss is a generic lag angle. In (12), P ss is the maximum value of a considered sinusoidal variation of the permeance density caused by the slots. Thus, the portion of the permeance density related to the stator characteristics P s is the sum of the average value (related to the average magnetic value of the air gap) and the portion considered to have a sinusoidal variation due to the existence of the slots. The rotor slot angular frequency ω ss is obtained from (13) when traveling through the air gap at the synchronous speed of mechanical rotation, where N s is the stator slots number.
The simplified air gap induction waveform generated by the rotating field of the rotor referenced to the stator is modeled by (14), resulting in (15) using the previous equations. The first term in (15), related to the permeance density average value, has electrical frequency as its fundamental (representing behavior as if there were no slots). The second term is related to the variation in permeance density due to the stator slots. This second term is an amplitude modulation process. When the machine is operating at steady state, the angular velocities and lag angles in (15) are constant. The phase angles γ, α m and α ss can be assumed to be null without loss of generality [50], i.e., they do not interfere with the spectral content of the waveforms in terms of frequencies and amplitudes if the ferromagnetic materials are homogeneous, linear, and without saturation.
Applying Euler's Formula to represent a cosine function in exponential form, equation (15) can then be written as (16), where A and B are constants, and R(t) is the resulting waveform. R(t) is composed of the rotor magnetomotive force (MMF) F r (healthy) (γ,t), the modulating signal m(t) with angular fundamental frequency ω e , and the waveform of the permeance density P s (healthy) (γ,t). Equation (16) in the time domain can be rewritten as (17) by applying the Fourier transform in the frequency domain. The waveform of the angular frequency permeance density ω ss is the carrier/modulator. In other words, in (17) the first term on the right-hand side contains the spectrum of the magnetomotive force m̂(ω e ) and the second term aggregates the two frequency components m̂(ω ss − ω e ) and m̂(ω ss − ω e ) according to modulation theory. As the aim here is to study the composition and behavior of frequency spectrum components, and there is no concern with absolute values of amplitudes, the signals (waveforms) can be taken in p.u. (per unit). Thus, if the machine is perfect with sinusoidal waveforms, for a sensor referenced to the stator, the resulting waveform R(t) (as shown in Fig. 5 in red) would be composed of the sum of an electrical fundamental signal and a modulated signal. The FFT analysis of this signal shown in Fig. 6 contains the electrical fundamental frequency and the two frequencies resulting from the modulation process. Note that the slot frequency is not present. Thus, through this modulation process, the induction waveform is not monotonic and without the presence of the slot frequency. The characteristics of the machine used in this simulation are 8 poles on the rotor and 72 slots on the stator, operating at 50 Hz.
When there is a small asymmetry in the rotating magnetic field from the rotor, the fundamental frequency of the machine becomes that of mechanical rotation, as discussed above. The modulating signal waveform m(t) of the magnetomotive force produced by the rotor in the air gap will contain the fundamental of mechanical rotation and its harmonics (the electrical fundamental is included in the signal m(t), as well as its typical odd harmonic content if constructive characteristics of a real machine are taken into account, see waveforms in Fig. 3 and their FFT analysis in Fig. 4), so that the entire content of the modulating signal m(t) is shifted to the right and left of the slot frequency ω ss . Thus, the harmonic content of the resulting waveform R̂(ω m ) becomes a function of ω m , as expressed by (18) in the frequency domain, where δ is the unit impulse function, a k and b k are the amplitudes of each frequency component (k = 1,2,3,...).
Simulated waveforms: rotor magnetomotive force; airgap permeance density due to stator slots; resulting modulation waveform; and magnetic induction at a stator-referenced point for the healthy SM.
B. Numerical simulation for rotor faults
For defects in the generation of the rotor magnetomotive force, either due to inhomogeneous construction factors or magnetic anisotropy of the rotor core, all the sensors around the machine must necessarily be sensitized in a similar way (have the same change pattern), in general by changing many of the amplitudes of the frequency spectrum components. This defect type is therefore the easiest to detect, regardless of the use of content analysis from modulation processes. Because, as already mentioned, those below and close to the electrical fundamental frequency tend to have their amplitudes highly modified. In addition, the low-frequency content in real machines is less attenuated by the housing. Equation (19) is used to simulate this fault type using the rotor magnetomotive force F r (fault1) (γ,t) with a sinusoidal waveform. In this simplified modeling, this equation represents an example of this type of defect. The simulated fault causes a reduction of ξ in the amplitude of one of the semicircles of the waveform generated by the faulty rotor F r (fault1) (γ,t), contained in the modulator component m(t) of the modulation process expressed by (16). The time intervals of the rotation period with a change in the waveform of the faulty rotor T r are given by (20). Equation (19) is then applied to (14) to obtain the induction waveform.
Fig. 7 shows the hypothetical induction waveform for this fault type simulated numerically (ξ = 0.01, i.e. a 1% reduction in the amplitude of the faulty pole) for an 8-pole SM, adapting it as if it was a signal acquired by an induction field sensor [3], [42] with the continuous content removed. The influence of the induction waveform coming from the stator excitation is neglected (as if it was operating at no load and disconnected from the grid), with the machine rotating only excited by the rotor, just as in the results presented previously with the FEM. The fault is like the one simulated with the FEM in the results shown in Fig. 2 and Fig. 3 (with ξ = 1.00), although it has a lower intensity (ξ= 0.01). Fig. 7 shows the waveforms for one period of mechanical rotation and Fig. 8 the FFT analysis for the induction waveform. The presence of harmonic components associated with the mechanical rotational frequency is observed, together with the absence of odd-order harmonics of the electrical fundamental frequency. Accordingly, rotor faults do not significantly excite the odd harmonic orders of the electrical fundamental frequency. These results are obtained from numerical simulations of the SM assuming purely sinusoidal waveforms.
Simulated waveforms of the rotor-generated magnetomotive force; airgap permeance density variation due to stator core slots; resulting modulation waveform; and magnetic induction at a stator-referenced point for the no-load SM with a rotor fault.
Fig. 9 shows the FFT analysis for FEM simulations in the healthy (ξ= 0) and faulty ξ= 1.0) conditions. For the faulty case, comparing the result shown in Fig. 4 obtained by FEM simulation with this one using the simple analytical model, there is a visual similarity in the pattern of the FFT analysis. However, there are many component arrangements with higher amplitudes compared to the analytical case in ranges centered on the odd electrical harmonics. In the FFTs of the FEM results, there are odd electrical contents, mainly due to the non-linearity of the ferromagnetic material used in the FEM simulation, with a non-monotonic rotor magnetomotive force waveform. This odd harmonic content of the electrical fundamental belongs to the waveform of the modulating content m(t). For healthy SM, the harmonic blocks tend to have their centers on the odd components of the electrical fundamental (However, the highest amplitude frequency of each block is not necessarily an odd harmonic of the electrical fundamental). By comparing the healthy and faulty cases, it is observed that even-order electrical harmonics tend to exhibit relatively higher amplitudes in the presence of a fault, showing behavior like that reported in Fig. 8, which was numerically obtained using the simplified analytical model. As previously mentioned, the use of spectral content analysis associated with the modulation process is not strictly required for the detection of this type of fault, as can be inferred from the behavior illustrated in Fig. 8 and Fig. 9. In general, this type of fault does not significantly alter the amplitudes of the odd harmonic content of the electrical fundamental frequency, which remains nearly identical even in an extreme case with a missing pole (see Fig. 9), as also concluded from the FFT analysis of the magnetic induction using the simplified analytical model.
FFT analysis of magnetic induction waveforms at a stator tooth for the healthy SM and for the no-load SM with a rotor fault.
FFT analysis of the voltage induced in a stator-tooth probe coil obtained by FEM for the SM operating off-grid at no load, under healthy conditions and with one unexcited rotor pole.
Nevertheless, the fault may induce local variations in the magnetic induction levels within the ferromagnetic material, such that the spectral content may also be modified, thereby complicating the localization and identification of an incipient fault. This important aspect is not addressed in this work.
C. Numerical simulation of a partial stator core fault in a no-load SM with a healthy rotor
An incipient fault in the ferromagnetic core or in the excitation part of the stator does not cause the appearance of mechanical rotation harmonic content, as the changes are local and not rotational. To represent this phenomenon, the waveform of the carrier permeance density with a fault in a stator tooth P s (fault2) (γ,t) given by (21) is applied to (14). The distribution function of the portion of the permeance density due to the slots in the defective stator P ssf (γ,t) is given by (22), where the time plots in the rotation cycles in which there is a defect in the stator T s are described by (23), with ζ being a defect factor (for example, of a degree of dimensional or magnetic inhomogeneity with respect to the other teeth, the null value being the state without a defect) and N sζ being the number of the tooth with inhomogeneity . The simulated defect would be as if a stator tooth has a problem that alters its magnetic permeability. Fig. 10 shows the waveforms for a mechanical rotation period, with ζ= 0.01 (1% inhomogeneity), and Fig. 11 shows the FFT analysis for the magnetic induction waveform resulting from the interaction between the magnetomotive force generated by the rotor windings and the stator permeance density for this fault. Only the harmonic content of the electrical fundamental appears (compare the FFT analyzes for the healthy and faulty cases). Thus, for similar types of faults, the analysis should be monitoring changes in this specific content. The fault will also preferably be detected in sensors close to its location, with different analysis behavior between sensors. This is because the variations in the amplitudes of the spectral components in the sensors around the SM are different, and may not even occur in certain sensors, depending on the size of the machine and the respective location of the sensor in relation to the location of the defect. Experimentally, non-pronounced faults in the stator core are difficult to detect, especially if there is no sensor near the fault location.
D. Numerical simulation of combined rotor pole excitation and partial stator core faults in a no-load SM
To simulate the no-load SM with a faulty rotor and a defect in one stator tooth, the waveform obtained from (14) combined with the rotor magnetomotive force (19) and the stator permeance density (21) are used. Two levels of rotor anomaly severity are simulated: i) ξ= 0.0025 (slight asymmetry, nearly healthy) and ii) ξ= 0.1 (pronounced defect in one pole, reducing amplitude by 10%). For the defect in permeance density, both cases use a value of ζ= 0.05 in (22), representing a 5% decrease in magnetic permeance in a tooth. Fig. 12 presents the waveforms for one mechanical rotation period for the “i” case. Fig. 13 shows the FFT analysis for the magnetic induction waveform with and without the imposed defects. Comparing these waveforms to those shown in Fig. 11, there is, as expected, the appearance of mechanical rotation content. The stator core defect is still evident in the harmonic content of the electrical fundamental. Fig. 14 shows the waveforms for one mechanical rotation period for case “ii” and Fig. 15 the FFT analysis for the magnetic induction waveforms with and without the simulated defects. A rotor defect, as seen in simulated case “ii”, can hide the amplitude changes caused by a stator core defect. Detecting faults in the SM stator core can be greatly limited by significant rotor asymmetries. This theoretical study highlights how the modulation process helps in detecting incipient faults. Stator core faults are most noticeable in spectral regions influenced by modulation, particularly near the slot frequency and its multiples. The rotor defect, which can be readily identified at low frequencies, operates independently of modulation processes, as previously noted. Therefore, a generalization can be applied: low-frequency variations likely suggest rotor defects, while high-frequency variations may indicate stator issues. The stator fault is typically detected by sensors positioned near the fault location, whereas the rotor fault is detected by all sensors.
Simulated waveforms: rotor magnetomotive force; air-gap permeance density variation due to stator core slots; resulting modulation waveform; and stator-tooth magnetic induction for the no-load SM with a stator tooth defect.
FFT analysis of simulated magnetic induction for healthy SM and for SM with a stator tooth defect.
Simulated waveforms: rotor magnetomotive force; airgap permeance density variation due to stator core slots; resulting modulation waveform; and stator-tooth magnetic induction for the no-load SM with defect levels of ξ = 0.0025 and ζ= 0.05.
FFT analysis of the simulated stator-tooth magnetic induction waveform for the healthy case and defective case shown in Fig. 12.
Simulated waveforms: rotor magnetomotive force, variation in permeance density as a function of air gap and stator core slots, waveform resulting from the modulation process and induction waveform at a stator tooth for the SM at no load and defect degrees with ξ = 0.1 and ζ = 0.05.
FFT analysis for magnetic induction at a stator tooth for both healthy and defect cases shown in Fig. 14.
E. Numerical simulations with rotor eccentricity
In the case of a static eccentricity fault, rotor shaft displacement affects the magnetomotive force. Amplitudes increase in regions where the air gap is minimal and decrease where it is maximal [8], in a manner similar to the studies reported in [51], [52]. The harmonic content amplitudes of the waveforms, obtained from sensors positioned perpendicular to the rotor shaft displacement, are expected to exhibit minimal variation when comparing healthy and faulty conditions. Consequently, the results obtained from individual sensors are not expected to behave uniformly.
By employing multiple sensors to compare healthy and faulty scenarios, it becomes possible to determine the direction of the shaft displacement [51]. This is achieved by analyzing the variations - whether increases, decreases, or stability - in the amplitudes associated with sensor positions. The spectral content amplitudes may not behave linearly in a real synchronous machine due to local variations in magnetic induction within the stator core, particularly in regions corresponding to the maximum or minimum air gap. For the identification of this type of fault, it is recommended to analyze the harmonic content associated with the mechanical rotational frequency in the low-frequency range.
In the following subsections, cases involving rotor eccentricity are investigated.
E.1 Numerical simulation with dynamic eccentricity fault
When a dynamic eccentricity fault occurs, the harmonic content of all the sensors is altered in a similar way. To simulate this type of defect, a sinusoidal frequency variation component equal to that of the mechanical rotation is added to the waveform of the permeance density P gde (γ,t), according to (24), where χ is the amplitude of the degree of severity and αχ is the defect phase. Equations (24) and (25) are used in (14), with ξ= 0.01 and χ= .1. Fig. 16 shows the simulated waveforms and Fig. 17 the FFT analysis for the magnetic induction waveform with and without dynamic eccentricity. In this defect, due to the significantly higher amplitude of the electrical fundamental, the mechanical rotation components adjacent to the electrical fundamental are severely altered. There is also the appearance of the odd harmonic content of the electrical fundamental, which did not exist in the content with the no-load SM and rotor fault (see FFT analysis in Fig. 8). This type of fault can preferably be detected by varying the amplitudes of the mechanical rotation components adjacent to the electrical fundamental and its odd harmonics.
Simulated waveforms: rotor magnetomotive force, permeance density variation as a function of the airgap and stator core slots, waveform resulting from the modulation process, and induction waveform of the SM under no-load conditions with dynamic eccentricity.
FFT analysis of the simulated magnetic induction waveforms in a stator tooth for the healthy condition and the fault case, corresponding to Fig. 16.
Reference [2] presents the results of an occurrence of a shaft displacement and rotor unbalance fault in a 56-pole, 60 Hz, 305 MVA generator. In [53], autoencoders were successfully employed among other techniques to detect other harmonics. Subsequently, taking into account the operating point of the machine, detection based on statistical metrics was facilitated [2]. The most prominent amplitude variation detected in the harmonic content occurred for the 302.14 Hz mechanical harmonic, the first mechanical harmonic adjacent to the 300 Hz electrical fifth harmonic (the mechanical fundamental is approximately 2.14 Hz). For a SM with non-sinusoidal waveforms and non-linear materials (see Fig. 3), the fifth electrical harmonic has significant amplitude (see Fig. 4). Reference [2] did not support the reason why the amplitude of the mechanical rotation harmonic adjacent to the fifth electrical harmonic changed the most as the defect worsened. The reason for the change in this harmonic is presented here: dynamic eccentricity/vibration defect. Fig. 18 shows the behavior over time of this harmonic of the amplitude of the 302.14 Hz mechanical harmonic monitored by six sensors distributed around the SM [3]. All the amplitudes obtained from measurements over time increased with the evolution of the incipient fault. Some of the amplitude curves showed greater variations than the others when the machine went from a healthy state to a faulty state, as there was also a displacement of the shaft in one direction. Fig. 19 shows the variations in the amplitudes coming from each sensor for the mechanical rotation frequency. Visually, there is no information on the occurrence of the fault, even though it is a fault related to the rotor. The slight variations in the amplitudes are due to changes in the operating points of the generator synchronized to the electrical bus [2]. This type of fault is complex to detect and analyze when applying the scattered field analysis methodology. As the model used here does not contain the odd electrical harmonic content (the stator MMF is sinusoidal), this type of mechanical defect has altered the mechanical content adjacent to the electrical fundamental in the modeling used in this article. However, this experimental result corroborates the simplified analysis strategy presented here. This simple analysis strategy presented here using numerical simulations has made it easier to understand the complex frequency spectra behavior of this 305 MVA SM, which is non-linear and rich in inherent harmonic content, when it presents this type of defect.
Evolution of the 302.14 Hz frequency amplitudes in a 56-pole, 60 Hz, 305 MVA generator at a power plant, during the development of an incipient shaft displacement fault and rotor unbalance.
E.2 Numerical simulation of dynamic eccentricity with a stator tooth defect
In this numerical simulation of dynamic eccentricity with a stator tooth defect, the rotor poles are considered homogeneous. Thus, as the rotor is perfect, there is no mechanical rotation harmonic content. The analytical model for the case under study is given by (26). The simulated waveforms are presented in Fig. 20, while the FFT analysis for the magnetic induction waveform, with and without dynamic eccentricity and a defect in a stator tooth, is shown in Fig. 21. The electrical fundamental harmonic content is present because a modulation process occurs between the rotor magnetomotive force and the stator permeance density. In this case of a fault with a monotonic characteristic (frequency equal to the machine rotation) of the dynamic variation of the air gap, there is a change in the content of the components adjacent to the electrical fundamental, at 47.5 Hz and 62.5 Hz, due to a modulation process between the electrical fundamental frequency and frequency of the variation of eccentricity. If the defect has more frequency components, there would be an increase in the mechanical rotating frequency content adjacent to the electrical fundamental. In a real SM, there are likely to have effects on the amplitudes of the components adjacent to the electrical odd harmonics.
Evolution of the fundamental mechanical rotation frequency (2.14 Hz) amplitudes in a 56-pole, 60 Hz, 305 MVA generator at a power plant, during the development of an incipient shaft displacement fault and rotor unbalance.
E.3 Numerical simulation of dynamic eccentricity with defects in the stator core and rotor magnetomotive force generation
In this case, the dynamic eccentricity fault of the permeability change of a stator tooth and the pole excitation of the magnetomotive force of the rotor are simulated. The harmonic content is composed by the assembly of the two previous simulation analyses, described earlier in sub-sections E.1 and E.2, and is given by (19) and (26) applied to (14).
Simulated waveforms of the SM under no-load conditions with dynamic eccentricity: rotor magnetomotive force, permeance density variation as a function of the air gap and stator core slots, waveform resulting from the modulation process, and stator tooth induction waveform.
FFT analysis for the simulated magnetic induction waveform in a stator tooth for the fault condition shown in Fig. 20 and for the healthy condition.
Fig. 22 shows the simulated waveforms. Fig. 23 shows the FFT analysis for the magnetic induction waveform with and without dynamic eccentricity, including defects in a stator tooth and in the rotor magnetomotive force. The harmonic spectrum behavior is similar to the case discussed and shown in Fig. 12 and Fig. 13. However, since there is no eccentricity in the case shown in Fig. 12, the amplitudes adjacent to the electrical fundamental (or its odd content in the case of a real SM) are not preferred candidates for detecting or typifying the eccentricity fault. In a spectral content analysis process, if the components adjacent to the electrical fundamental (and its odd harmonics in the case of a real SM) were altered to a greater degree than the behavior of the others, it could be inferred that dynamic eccentricity problems are occurring in the machine. Note that in the studied cases, the eccentricity variation frequency is equal to the mechanical rotation frequency. If there are other frequency components in the eccentricity, the harmonics that are candidates for detection would be shifted by these frequencies in the spectrum, increasing the complexity of analysis and diagnosis.
No-load SM waveforms with dynamic eccentricity, stator tooth defect, and rotor pole excitation fault: rotor magnetomotive force, permeance variation, modulation, and stator tooth induction.
F. Numerical simulation of stator core and rotor pole excitation faults with rotor vibration
In this simulated case of SM with defects in a stator tooth that change its magnetic permeability and in one pole of the rotor magnetomotive force, the characteristic of a randomly vibrating rotor P vbr (γ,t) is added, resulting in the permeance density given by (27). The vibration P vbr (γ,t) is modeled by a type of red noise (noise with higher power density at low frequencies) to approximate possible real cases.
FFT analysis of the simulated stator tooth induction waveform for the fault case shown in Fig. 22 and the healthy condition.
The red noise used is generated by integrating a Gaussian white noise signal [54] with a standard deviation of 1% of the amplitude of the average permeance component (corresponding to the average effective magnetic air gap). Fig. 24 shows the waveforms of the quantities involved in the simulation applying (22) in (27). Fig. 25 shows the FFT analysis for the magnetic induction waveform with and without fault. In the previous cases, the smallest amplitudes of the frequency components arise from numerical noise of about - 330 dB (in real equipment, this would be the combination of ambient background noise and that generated by the instrumentation itself). Here, this bottom level is around −170 dB. In measurement and data analysis equipment [3], when the severity of the vibration is sufficient to cause the lower (background) level to rise in the frequency spectrum, this behavior can be an indicator of this type of defect.
No-load SM waveforms on a stator tooth and rotor pole excitation with rotor vibration: rotor magnetomotive force, permeance variation, modulation waveform, and stator tooth induction.
FFT analysis of the simulated stator tooth induction waveform for the fault case shown in Fig. 24 and the healthy condition.
G. Stator pseudo rotating field modulation with rotor characteristics
If the stator electric currents are purely sinusoidal waveforms, the stator magnetomotive force F s (γ,t), given by (28), for a linear and homogeneous magnetic circuit will also be sinusoidal with a peak value F sp and a generic lag α e . Consequently, the waveforms measured by fixed sensors around the stator would also be sinusoidal. The alterations on the stator are found to be capable of modifying amplitude and phase, without causing an increase in frequency components in the waveforms captured by the sensors. Thus, in a shadow coil within the stator, such as short-circuited turns, the magnetic flux generated by the current induced in these turns will have the same harmonic content as the variable flux within the shadow coil. Consequently, the signal detected by the sensor will be able to show solely changes in amplitude and phase, thereby complicating the detection of the fault. However, as the rotor core rotates, the rotor permeance density seen by the stator P r (γ,t) can be defined according to (29) as a function of parts of the mean air gap P rm and the composition of the saliences P rl (γ,t) with the rotor slots, which are constituted by the damping bars slots and/or the excitation winding slots. In the condition of synchronous rotation of the rotor, the saliences frequency ω sal is calculated according to (30), while the rotor slot frequency ω rs is determined by (33). Thus, even if the F s (γ,t) of the stator is monotonic, the sensors positioned along the outer generator circumference will capture harmonic components other than the electrical fundamental. The SM under consideration in this study has eight salient poles, which are responsible for generating the first and third order harmonic components derived from the modulation process. These components are illustrated in orange in Fig. 26. The SM also has four damping bars installed on each of the rotor poles (four slots per pole), causing an 8f sal carrier frequency to appear (in a real SM, the presence of a harmonic higher density is due to the inhomogeneous construction characteristics of the rotor). The case under consideration involves a defect in the variation of permeance at one of the poles. So, under these conditions, if a variation in permeance is assumed to be located at one of the rotor poles, the fundamental frequency of 2 f sal of waveform P r (γ,t) becomes that of mechanical rotation f m . With the result of the modulation process for this case applying (34), Fig. 27 shows the FFT analysis of the waveform at a fixed point on the stator.
FFT analysis for the magnetic induction waveform at a fixed point on the stator for the healthy SM.
FFT analysis of the magnetic induction waveform at a fixed stator point for the SM with a rotor pole fault.
In the event of a fault in the stator winding, ideally there will be no change in the composition of the frequency spectrum. However, there may be different changes in amplitude and phase in signals coming from sensors positioned in different places outside the machine stator. In fact, the armature currents of large generators synchronized at the busbar are generally monotonic, with negligible harmonic content. Thus, any changes in the amplitudes of the armature currents will be reflected in proportional changes in all the harmonics of the waveform frequency spectra obtained by the sensors around the machine. This is relevant to the fault detection process, because if there are similar changes in most harmonic amplitudes, there is an indication of a possible defect in the stator winding. If, in addition to this, the signals picked up by the sensors distributed outside the stator show different behavior, there are strong indications that the fault is in the stator (such as defects in the windings, variation in the local permeance of the stator, shorting of plates in the stator or other currents in short-circuit paths formed anywhere in the stator).
VII. Discussion and Conclusions
Traditionally, in predictive maintenance processes aimed at condition monitoring to increase asset reliability and availability, synchronous machines in industrial plants have been predominantly monitored by mechanical vibration systems. However, the fundamental interaction occurs between the magnetic field and the magnetic flux density, constituting an essential phenomenon in the energy conversion process. In air, the magnetic flux density is linearly related to the magnetic field through magnetic permeability. Consequently, monitoring the magnetic field in the machine air gap or in the external stray field allows indirect monitoring of the electromechanical energy conversion process and associated anomalies. Accordingly, the magnetic field is one of the most important and representative quantities of the electrical machine; however, it remains scarcely employed in monitoring systems.
To obtain information regarding the magnetic subsystem, two basic sensor positioning configurations may be adopted: mounting on the rotor or mounting at a fixed point on the stator. When referred to the rotor, technical challenges arise in transmitting sensor signals to the processing module. For this reason, due to cost as well as installation considerations, stator-mounted configurations are generally employed. Furthermore, external installation is preferably adopted as a non-invasive approach, providing additional advantages, including ease of installation and maintenance of the monitoring system itself.
When stator measurements capture a rotating field with rotor-originated anomalies, changes in rotor excitation or in the magnetic core tend to affect the sensors distributed around the stator in a similar manner. In the case of excitation winding defects, modifications are particularly observed in the low-order harmonics of the rotational frequency. In contrast, stator-originated faults typically affect only part of the sensors and in a non-uniform manner, promoting changes mainly in the odd harmonics of the electrical fundamental. The sensors response pattern, by itself, provides a relevant indication of the fault location, whether in the stator or in the rotor. By analyzing the regions of amplitude variation in the frequency spectrum, another relevant characteristic - further corroborating the analysis of inter-sensor patterns - can be identified: field excitation faults induce significant changes in the amplitudes of harmonic components, typically associated with the rotational frequency and its low-order harmonics.
One of the primary challenges in detecting incipient stator faults arises from the intrinsic composition of the magnetic field. The odd harmonics of the electrical fundamental frequency inherently exhibit high amplitudes due to the nonlinear behavior of ferromagnetic materials, the dimensional configuration of the poles, and the winding arrangement. As a result, the additional spectral components generated by localized stator defects - typically appearing at frequencies above the fifth harmonic of the fundamental frequency - are physically superimposed on the dominant harmonic components and may therefore remain not able to be identified as different in the magnetic spectrum.
As discussed, the very nature of the underlying electromagnetic phenomena favors the exploitation of modulation processes as a mechanism for evidencing stator-originated defects. One of the contributions of this work was to elucidate the fundamental aspects of modulation processes associated with different fault types and to discuss their implications for the development and analysis of the investigated cases. In this way, the study advances the establishment of general guidelines for improving methodologies for detection, localization, and classification of incipient faults, seeking to avoid the need for training procedures or the use of extensive datasets
The proposed approach was deliberately presented in simplified form, employing monotonic waveforms that do not fully reproduce the complexity observed in real systems. In practice, the quantities involved in modulation processes - including stator and rotor current distributions, nonlinearities and inhomogeneities of ferromagnetic materials, and non-uniform winding distributions - result in waveforms composed of multiple harmonics. Consequently, the waveforms intrinsically associated with the modulation processes in the spectral composition are significantly more complex. This aspect was not explored in the present study and may require future investigations based on numerical field computation methods or experimental analyses combined with advanced data science tools, such as artificial intelligence techniques. Furthermore, the mechanisms analyzed focused on amplitude modulation, although other types of modulation may also be present in synchronous machines. These aspects leave the issues addressed herein open for future research.
Despite the adopted simplifications, the analyses were supported by previously published studies in the literature and, in this work, further substantiated by both the results obtained through the finite element method and the presentation of a real case involving a generator operating in a hydroelectric power plant under incipient fault conditions. The fault detection process proved to be particularly challenging due to the resulting spectral composition, especially because it involved harmonics of relatively high order and low amplitudes, for which an initial approach required the use of advanced signal-processing tools [53]. Owing to the modulation processes, the fault could be identified and was subsequently verified by the power plant maintenance team. At the time, even as the defect evolved, the mechanical vibration-based monitoring system could not confirm its occurrence.
In a signal acquisition and processing flowchart for fault detection/diagnosis, Reference [14] suggests the adoption of certain guidelines for monitoring systems. However, it does not address a detailed theoretical foundation. Based on the investigations presented herein, the problem can be understood more comprehensively, enabling refinement of the proposal in [14], particularly given the limitations of large datasets for training artificial intelligence-based tools and the impracticality of deliberately inserting defects in machines in operation.
Additionally, in applications involving machines in service, it is essential that monitoring processes explicitly consider the operating point and be conducted continuously [2], using accurate spectral tracking systems capable of handling small speed variations and grid frequency fluctuations. Although not explored in this study, such operational influences are recognized as introducing relevant perturbations in magnetic signatures [2].
Through theoretical case studies, this work complements the existing literature by providing a structured interpretation of the spectral composition of magnetic signatures in synchronous machines under both healthy and faulty conditions. Although data analysis tools currently exist for detecting, locating, and classifying incipient faults based on electromagnetic quantities, most rely on training procedures. Such training may be performed in specially designed machines intended for deliberate fault insertion, but not in units operating in power plants or industrial facilities. Moreover, each machine exhibits its own magnetic signature and specific spectral composition for each fault type. It is therefore expected that the analyses and conclusions presented herein will contribute to the advancement and consolidation of more robust condition monitoring strategies applicable to synchronous machines in general.
Acknowledgment
This research was motivated and partially funded within the scope of the R&D program of Engie Brasil Energia and Itá Energética S.A., PD-00403-0057/2023, entitled “Non-invasive Equipment for Fault Detection in Synchronous Generators through External Magnetic Field - Pioneer Batch and Market Introduction,” regulated by ANEEL. This work was also supported by the Brazilian National Council for Scientific and Technological Development (CNPq) and by the Brazilian Federal Agency for Support and Evaluation of Graduate Education (CAPES), Brazil.
References
-
1 R. B. Leandro, A. S. E. Silva, I. C. Decker, and M. N. Agostini, "Identification of the oscillation modes of a large power system using ambient data," Journal of Control, Automation and Electrical Systems, vol. 26, no. 4, pp. 441-453, 2015, doi: 10.1007/s40313-015-0187-1.
» https://doi.org/10.1007/s40313-015-0187-1. -
2 L. O. S. Grillo, C. A. C. Wengerkievicz, N. J. Batistela, P. Kuo-Peng, and L. M. de Freitas, "A method for statistical processing of magnetic field sensor signals for non-invasive condition monitoring of synchronous generators," Sensors, vol. 22, no. 22, pp. 672-681, 2022, doi: 10.3390/s22228631.
» https://doi.org/10.3390/s22228631. -
3 H. F. Santos, M. Rigoni, R. A. Elias, L. A. Feler, C. A. C. Wengerkievicz, N. J. Batistela, N. Sadowski, P. Kuo-Peng, J. P. A. Bastos, and L. M. Freitas, "Non-invasive monitoring system of synchronous generator using external field," Journal of Microwaves, Optoelectronics and Electromagnetic Applications, vol. 16, no. 1, pp. 70-89, 2017, doi: 10.1590/2179-10742017v16i1872.
» https://doi.org/10.1590/2179-10742017v16i1872. - 4 International Organization for Standardization, ISO 20816-5:2018 - Mechanical vibration - Measurement and evaluation of machine vibration - Part 5: Machine sets in hydraulic power generating and pump-storage plants, Geneva, Switzerland: ISO, 2018.
-
5 G.-A. Capolino, R. Romary, H. Henao, and R. Pusca, "State of the art on stray flux analysis in faulted electrical machines," IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD), Athens, Greece, 2019, pp. 181-187, doi: 10.1109/WEMDCD.2019.8887805.
» https://doi.org/10.1109/WEMDCD.2019.8887805. -
6 M. Sasic, S. R. Campbell, and B. Lloyd, "Flux monitoring improvement," IEEE Industry Applications Magazine, vol. 17, no. 5, pp. 66-69, 2011, doi: 10.1109/MIAS.2010.939656.
» https://doi.org/10.1109/MIAS.2010.939656. -
7 D. Howe and P. Hammond, "Examination of the axial flux in stator cores with particular reference to turbogenerators," Institution of Electrical Engineers, vol. 121, no. 12, pp. 1536-1542, 1974, doi: 10.1049/piee.1974.0318.
» https://doi.org/10.1049/piee.1974.0318. -
8 B. A. T. Iamamura, Y. Le Menach, A. Tounzi, N. Sadowski, and E. Guillot, "Study of static and dynamic eccentricities of a synchronous generator using 3-D FEM," IEEE Transactions on Magnetics, vol. 46, no. 8, pp. 3516-3519, 2010, doi: 10.1109/TMAG.2010.2043347.
» https://doi.org/10.1109/TMAG.2010.2043347. -
9 S. Salon, S. Salem, and K. Sivasubramaniam, "Monitoring and diagnostic solutions for wind generators," IEEE Power and Energy Society General Meeting, Detroit, MI, USA, 2011, pp. 1-4, doi: 10.1109/PES.2011.6039907.
» https://doi.org/10.1109/PES.2011.6039907. -
10 H. Wen and M. Cheng, "Unified analysis of induction machine and synchronous machine based on the general airgap field modulation theory," IEEE Transactions on Industrial Electronics, vol. 66, no. 12, pp. 9205-9216, 2019, doi: 10.1109/TIE.2018.2885725.
» https://doi.org/10.1109/TIE.2018.2885725. -
11 I. Sadeghi, H. Ehya, J. Faiz, and A. A. S. Akmal, "Online condition monitoring of large synchronous generator under short circuit fault - a review," IEEE International Conference on Industrial Technology (ICIT), Lyon, France, 2018, pp. 1843-1848, doi: 10.1109/ICIT.2018.8352465.
» https://doi.org/10.1109/ICIT.2018.8352465. -
12 J. Penman and H. Jiang, "The detection of stator and rotor winding short circuits in synchronous generators by analysing excitation current harmonics," International Conference on Opportunities and Advances in Power Generation, Durham, UK, 1996, pp. 137-142, doi: 10.1049/cp:19960135.
» https://doi.org/10.1049/cp:19960135. -
13 P. Neti and S. Nandi, "Stator interturn fault detection of synchronous machines using field current and rotor search-coil voltage signature analysis," IEEE Transactions on Industry Applications, vol. 45, no. 3, pp. 911-920, 2009, doi: 10.1109/TIA.2009.2018905.
» https://doi.org/10.1109/TIA.2009.2018905. -
14 I. Zamudio-Ramirez, R. A. Osornio-Rios, J. A. Antonino-Daviu, H. Razik, and R. Romero-Troncoso, "Magnetic flux analysis for the condition monitoring of electric machines: a review," IEEE Transactions on Industrial Informatics, vol. 18, no. 5, pp. 2895-2908, 2022, doi: 10.1109/TII.2021.3070581.
» https://doi.org/10.1109/TII.2021.3070581. -
15 E. Mazaheri-Tehrani and J. Faiz, "Airgap and stray magnetic flux monitoring techniques for fault diagnosis of electrical machines: an overview," IET Electric Power Applications, vol. 16, no. 3, pp. 277-299, 2022, doi: 10.1049/elp2.12157.
» https://doi.org/10.1049/elp2.12157. -
16 M. Mostafaei and J. Faiz, "An overview of various faults detection methods in synchronous generators," IET Electric Power Applications, vol. 15, no. 4, pp. 391-404, 2021, doi: 10.1049/elp2.12031.
» https://doi.org/10.1049/elp2.12031. -
17 B. Kedjar, A. Merkhouf, and K. Al-Haddad, "Large synchronous machines diagnosis based on air-gap and stray fluxes - an overview," IEEE International Conference on Electrical Machines (ICEM), Gothenburg, Sweden, 2020, pp. 1384-1389, doi: 10.1109/ICEM49940.2020.9270868.
» https://doi.org/10.1109/ICEM49940.2020.9270868. -
18 H. Henao, G.-A. Capolino, M. Fernandez-Cabanas, F. Filippetti, C. Bruzzese, E. Strangas, R. Pusca, J. Estima, M. Riera-Guasp, and S. Hedayati-Kia, "Trends in fault diagnosis for electrical machines: a review of diagnostic techniques," IEEE Industrial Electronics Magazine, vol. 8, no. 2, pp. 31-42, 2014, doi: 10.1109/MIE.2013.2287651.
» https://doi.org/10.1109/MIE.2013.2287651. -
19 C. J. Carpenter, "The application of the method of images to machine end-winding fields," IEE - Part A: Power Engineering, vol. 107, no. 35, pp. 487-500, 1960, doi: 10.1049/pi-a.1960.0109.
» https://doi.org/10.1049/pi-a.1960.0109. -
20 P. J. Tavner, "Contribution to the study of leakage fields at the ends of rotating electrical machines," Institution of Electrical Engineers, vol. 125, no. 12, pp. 1339-1349, 1978, doi: 10.1049/piee.1978.0286.
» https://doi.org/10.1049/piee.1978.0286. -
21 B. Belhoucine, A. Foggia, G. Meunier, B. Belhoucine, M. Besseau, H. Kermorgant, and X. Brunotte, "3D finite element investigation of the magnetic field outside electromagnetic devices," IEEE Transactions on Magnetics, vol. 30, no. 5, pp. 2964-2967, 1994, doi: 10.1109/20.312559.
» https://doi.org/10.1109/20.312559. -
22 G. G. Karady, S. H. Berisha, M. Muralidhar, J. A. Demcko, and M. Samotyj, "Variable speed motor drive generated magnetic fields," IEEE Transactions on Power Delivery, vol. 9, no. 3, pp. 1639-1646, 1994, doi: 10.1109/61.311199.
» https://doi.org/10.1109/61.311199. -
23 G. Le Coat, A. Foggia, J. Bongiraud, and P. Le Thiec, "Electromagnetic signature of induction machines," IEEE Transactions on Energy Conversion, vol. 14, no. 3, pp. 628-632, 1999, doi: 10.1109/60.790926.
» https://doi.org/10.1109/60.790926. -
24 J. Penman, M. N. Dey, A. J. Tait, and W. E. Bryan, "Condition monitoring of electrical drives," IEE Proceedings B - Electric Power Applications, vol. 133, no. 3, pp. 142-148, 1986, doi: 10.1049/ip-b.1986.0019.
» https://doi.org/10.1049/ip-b.1986.0019. -
25 G. B. Kliman, R. A. Koegl, J. Stein, R. D. Endicott, and M. W. Madden, "Noninvasive detection of broken rotor bars in operating induction motors," IEEE Transactions on Energy Conversion, vol. 3, no. 4, pp. 873-879, 1988, doi: 10.1109/60.9364.
» https://doi.org/10.1109/60.9364. -
26 J. Penman, H. G. Sedding, B. A. Lloyd, and W. T. Fink, "Detection and location of interturn short circuits in the stator windings of operating motors," IEEE Transactions on Energy Conversion, vol. 9, no. 4, pp. 652-658, 1994, doi: 10.1109/60.368345.
» https://doi.org/10.1109/60.368345. - 27 G. Pole, Application of magnetic fields to aid the detection and diagnosis of induction motor drive faults, Ph.D. dissertation, Cardiff Metropolitan University, Cardiff, UK, 2009.
-
28 T. Assaf, H. Henao, and G.-A. Capolino, "Simplified axial flux spectrum method to detect incipient stator inter-turn short-circuits in induction machine," IEEE International Symposium on Industrial Electronics (ISIE), Ajaccio, France, 2004, vol. 2, pp. 815-819, doi: 10.1109/ISIE.2004.1571918.
» https://doi.org/10.1109/ISIE.2004.1571918. -
29 A. Yazidi, H. Henao, G. A. Capolino, M. Artioli, F. Filippetti, and D. Casadei, "Flux signature analysis: an alternative method for the fault diagnosis of induction machines," IEEE Russia PowerTech Conference, St. Petersburg, Russia, 2005, pp. 1-6, doi: 10.1109/PTC.2005.4524578.
» https://doi.org/10.1109/PTC.2005.4524578. -
30 A. Ceban, R. Pusca, and R. Romary, "Study of rotor faults in induction motors using external magnetic field analysis," IEEE Transactions on Industrial Electronics, vol. 59, no. 5, pp. 2082-2093, 2012, doi: 10.1109/TIE.2011.2163285.
» https://doi.org/10.1109/TIE.2011.2163285. -
31 J. A. Ramirez-Nunez, J. A. Antonino-Daviu, V. Climente-Alarcón, A. Quijano-López, H. Razik, R. A. Osornio-Rios, and R. de J. Romero-Troncoso, "Evaluation of the detectability of electromechanical faults in induction motors via transient analysis of the stray flux," IEEE Transactions on Industry Applications, vol. 54, no. 5, pp. 4324-4332, 2018, doi: 10.1109/TIA.2018.2843371.
» https://doi.org/10.1109/TIA.2018.2843371. - 32 D. Thailly, R. Romary, J.-P. Lecointe, J.-F. Brudny, and P. Suau, "Synchronous machine diagnosis using an external magnetic flux sensor," International Conference on Electrical Machines (ICEM), Chania, Greece, 2006, pp. 462:1-462:6.
-
33 M. Cuevas, R. Romary, J.-P. Lecointe, and T. Jacq, "Non-invasive detection of rotor short-circuit fault in synchronous machines by analysis of stray magnetic field and frame vibrations," IEEE Transactions on Magnetics, vol. 52, no. 7, pp. 1-4, 2016, doi: 10.1109/TMAG.2016.2514406.
» https://doi.org/10.1109/TMAG.2016.2514406. -
34 J. P. Selvaggi, S. Salon, O.-M. Kwon, and M. V. K. Chari, "Calculating the external magnetic field from permanent magnets in permanent-magnet motors - an alternative method," IEEE Transactions on Magnetics, vol. 40, no. 5, pp. 3278-3285, 2004, doi: 10.1109/TMAG.2004.831653.
» https://doi.org/10.1109/TMAG.2004.831653. -
35 J. P. Selvaggi, S. Salon, O.-M. Kwon, M. V. K. Chari, and M. DeBortoli, "Computation of the external magnetic field, near-field or far-field, from a circular cylindrical magnetic source using toroidal functions," IEEE Transactions on Magnetics, vol. 43, no. 4, pp. 1153-1156, 2007, doi: 10.1109/TMAG.2007.892275.
» https://doi.org/10.1109/TMAG.2007.892275. - 36 M. V. Chari, S. R. Salem, S. Salon, and O.-M. Kwon, "Non-invasive monitoring and diagnosis of electric machines by measuring external flux density," U.S. Patent US7880473B2, 2011.
-
37 V. P. Bui, O. Chadebec, L.-L. Rouve, and J.-L. Coulomb, "Noninvasive fault monitoring of electrical machines by solving the steady-state magnetic inverse problem," IEEE Transactions on Magnetics, vol. 44, no. 6, pp. 1050-1053, 2008, doi: 10.1109/TMAG.2007.916593.
» https://doi.org/10.1109/TMAG.2007.916593. -
38 J. V. Leite, N. Sadowski, P. A. Silva, N. J. Batistela, P. Kuo-Peng, and J. P. A. Bastos, "Modeling magnetic vector hysteresis with play hysterons," IEEE Transactions on Magnetics, vol. 43, no. 4, pp. 1401-1404, 2007, doi: 10.1109/TMAG.2007.891390.
» https://doi.org/10.1109/TMAG.2007.891390. -
39 M. Rigoni, J. S. D. Garcia, A. P. Garcia, P. A. Silva, N. J. Batistela, and P. Kuo-Peng, "Rogowski coil current meters," IEEE Potentials, vol. 27, no. 4, pp. 40-45, 2008, doi: 10.1109/MPOT.2008.924860.
» https://doi.org/10.1109/MPOT.2008.924860. - 40 M. Rigoni, T. L. Santos, N. J. Batistela, N. Sadowski, and P. Kuo-Peng, "A current sensor for use in evaluation of metal oxide surge arrester," Soft Magnetic Materials Conference, Torino, Italy, 2009, pp. M3-10:1-M3-10:1.
-
41 M. Rigoni, N. Sadowski, N. J. Batistela, J. P. A. Bastos, S. L. Nau, and A. Kost, "Detection and analysis of rotor faults in induction motors by the measurement of the stray magnetic flux," Journal of Microwaves, Optoelectronics and Electromagnetic Applications, vol. 11, no. 1, pp. 68-80, 2012, doi: 10.1590/S2179-10742012000100006.
» https://doi.org/10.1590/S2179-10742012000100006. -
42 L. O. S. Grillo, C. A. C. Wengerkievicz, H. F. Santos, N. J. Batistela, P. Kuo-Peng, N. Sadowski, T. K. Matsuo, C. L. D. Souza, L. M. Freitas, and R. J. Nascimento, "Equipment for monitoring synchronous generators condition through external magnetic field waveforms," Journal of Microwaves, Optoelectronics and Electromagnetic Applications, vol. 21, no. 4, pp. 527-548, 2022, doi: 10.1590/2179-10742022v21i4268102.
» https://doi.org/10.1590/2179-10742022v21i4268102. -
43 P. Neti, A. B. Dehkordi, and A. M. Gole, "A new robust method to detect rotor faults in salient-pole synchronous machines using structural asymmetries," IEEE Industry Applications Society Annual Meeting (IAS), Edmonton, Canada, 2008, pp. 1-8, doi: 10.1109/08IAS.2008.22.
» https://doi.org/10.1109/08IAS.2008.22. -
44 H. F. dos Santos, N. Sadowski, N. J. Batistela, and J. P. A. Bastos, "Synchronous generator fault investigation by experimental and finite-element procedures," IEEE Transactions on Magnetics, vol. 52, no. 3, pp. 1-4, 2016, doi: 10.1109/TMAG.2015.2480546.
» https://doi.org/10.1109/TMAG.2015.2480546. - 45 M. Rigoni, N. J. Batistela, N. Sadowski, C. S. P. Gameiro, H. F. Santos, R. A. Elias, P. Kuo-Peng, J. P. A. Bastos, and L. M. Freitas, "System and method for identifying the characteristics of an electric machine," BR Patent BR102015011438-9, 2015. (Portuguese).
- 46 G. G. B. Ferri, L. Tominaga, T. K. Matsuo, G. F. M. Nascimento, L. O. S. Grillo, N. J. Batistela, L. Conte, and L. M. Freitas, “Analysis of short-circuit faults in synchronous generators using external magnetic field data and neural networks,” 1st International Colloquium on Power Generation and Electromechanical Energy Conversion, Dubrovnik, Croatia, 2025, pp. 1-7.
-
47 J. Park, P. N. Harmony, H. Moon and J. Baek, “Electromagnetic signal analysis for electrical fault diagnosis in synchronous generators,” Electronics, vol. 13, no. 15, pp. 3078:1-3078:15, 2024, doi: 10.3390/electronics13153078.
» https://doi.org/10.3390/electronics13153078. -
48 I. Balovnev, “Diagnostics of the technical condition of a synchronous generator using an external magnetic field,” Russian Electrical Engineering, vol. 96, no. 3, pp. 181-184, 2025, doi: 10.3103/S1068371225700233.
» https://doi.org/10.3103/S1068371225700233. - 49 S. L. Nau and S. B. Silveira, "Determination and analysis of causes of induction motor magnetic noise," Applied Computational Electromagnetics Society Journal, vol. 12, pp. 125-131, 1997.
- 50 B. P. Lathi, Linear systems and signals, 2nd ed. New York, NY, USA: Oxford University Press, 2005.
-
51 S. Bernier, A. Merkhouf and K. Al-Haddad, "Diagnosis of multiple defects within large hydroelectric generator using stray flux and air gap (distance and flux) measurements," IEEE Transactions on Industry Applications, vol. 60, no. 6, pp. 8687-8700, 2024, doi: 10.1109/TIA.2024.3441519.
» https://doi.org/10.1109/TIA.2024.3441519. -
52 S. Bernier, A. Merkhouf and K. Al-Haddad, "Stray flux and air gap flux experimental measurement and analysis in large hydro generators," 2023 IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD), Newcastle upon Tyne, United Kingdom, 2023, pp. 1-6, doi: 10.1109/WEMDCD55819.2023.10110944.
» https://doi.org/10.1109/WEMDCD55819.2023.10110944. - 53 M. Hoegen, “Strategies for the detection of variations in the external magnetic field behavior of synchronous generators (Portuguese),” Master’s thesis, Programa de Pós-Graduação em Engenharia Elétrica, Universidade Federal de Santa Catarina, Florianópolis, Brazil, 2021.
- 54 A. B. Carlson and P. B. Crilly, Communication systems: an introduction to signals and noise in electrical communication. New York, NY, USA: McGraw-Hill, 2009.