Open-access A Prosthetic Dysfunction Earlier Than Expected

Heart Valve Prosthesis; General Surgery; Thrombosis; Pannus

Próteses Valvulares Cardíacas; Cirurgia Geral; Trombose; Pannus

Heart Valve Prosthesis; General Surgery; Thrombosis; Pannus

Próteses Valvulares Cardíacas; Cirurgia Geral; Trombose; Pannus

Prosthetic Heart Valves, despite their improvements over the last few decades, can be subject to complications and dysfunction. Mechanical prosthetic valves have an expected lifespan of approximately 10 to 20 years, with many lasting longer. For biological valves, the lifespan is generally shorter (5 to 15 years). However, the durability varies according to individual factors, valve type, and patient health. Although their greater durability, Mechanical Heart Valves are more pro-thrombotic than biological valves, and their dysfunction may be associated, for example, with thrombotic events and the formation of pannus .1 Pannus is an inflammatory tissue composed of inflammatory cells, fibroblasts, and blood vessels, and its presence can lead to dysfunction or other complications such as valve obstruction or endocarditis. The prevalence of pannus in cardiac valve prostheses varies depending on several factors, such as the type of prosthesis (biological or mechanical) and the patients’ clinical conditions. It is estimated that the formation of pannus occurs in about 1% to 5% of patients with valve prostheses, although it may be more common in biological ones. The annual rate of thrombus formation can reach 5.7-8%, being higher in tricuspid and mitral valve prostheses.1 , 2 A multimodality-based approach can provide useful data for differential diagnosis, complementing clinical assessment and offering an appropriate and optimized therapeutic approach. Valve dysfunction, in case of delayed diagnosis, can progress to cardiogenic shock.1 Valvular dysfunctions can be structural (valve dysfunction due to changes related to the valve itself) or non-structural (dysfunctions not related to the valve resulting in stenosis or regurgitation, which include the formation of pannus ), which arises from the accumulation of fibrous tissue in the valve, causing its dysfunction. It forms less frequently than thrombi and its risk is higher in the mitral position compared to the tricuspid.2

The authors present a case of mechanical mitral valve prosthesis dysfunction due to pannus . A Caucasian 43 years-old woman, with dyslipidaemia and hypertension with a history of infectious endocarditis of the mitral valve in 04/2022, presented with signs of infectious infiltration of both leaflets and severe mitral regurgitation. At this point, a cycle of antibiotic therapy was performed with ampicillin and flucloxacillin, with no agent being isolated (neither in blood cultures nor microbiological examination of the explanted valve). A double-disc mechanical valve prosthesis was implanted in the mitral position. The patients were hypocoagulated with a vitamin K antagonist (warfarin, with target INR levels of 2.5-3.5) and discharged from the hospital for outpatient follow-up.

About a year after the intervention, she reported fatigue with moderate exertion. The INR value was 4.56, with adequate hypocoagulation in previous evaluations. A transthoracic echocardiogram was performed showing signs of prosthesis obstruction (transprosthetic mean gradient of 8 mmHg), due to a fixed disc in a closed position, and preserved Left Ventricular Ejection Fraction (58%). Faced with an abnormally high gradient, fluoroscopy was performed to assess valve function. Fluoroscopy, despite not being able to distinguish whether the valve dysfunction is due to pannus or thrombus, is extremely important because it allows us to understand that the valve movement is anomalous.3 Fluoroscopy was performed confirming immobility of one of the discs ( Figure 1 ). The histological examination of the surgical material was compatible with pannus .

Figure 1
– Fluoroscopy with evidence of immobility of one of the discs of the mitral valve prosthesis (arrows).

Pannus formation is usually indolent, occurring several years later. In this case, the authors present a case in which pannus formation occurred with significant obstruction shortly after surgery. In the case of hemodynamically significant pannus , the only therapeutic choice is surgery, and a differential diagnosis with thrombosis must be made. In this case, although the INR was at supra-therapeutic values, it was not expected that a pannus dysfunction would occur so early. The timely mechanism evaluation and its contextualization are essential, in order to personalize and optimize potential interventions. The use of an integrated strategy (clinical, laboratory, and imaging) is essential for the adequate guidance of these complex cases.

References

  • 1 Jiménez CES, Papolos AI, Kenigsberg BB, Ben-Dor I, Satler LF, Waksman R, et al. Management of Mechanical Prosthetic Heart Valve Thrombosis: JACC Review Topic of the Week. J Am Coll Cardiol. 2023;81(21):2115-27. doi: 10.1016/j.jacc.2023.03.412.
    » https://doi.org/10.1016/j.jacc.2023.03.412
  • 2 Lancellotti P, Pibarot P, Chambers J, Edvardsen T, Delgado V, Dulgheru R, et al. Recommendations for the Imaging Assessment of Prosthetic Heart Valves: A Report from the European Association of Cardiovascular Imaging Endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2016;17(6):589-90. doi: 10.1093/ehjci/jew025.
    » https://doi.org/10.1093/ehjci/jew025
  • 3 Faraj R, Diallo TH, Dib H, Sarsari M, Diafarou R, Zarzur J, et al. Mechanical Prosthetic Mitral Valve Obstruction: Pannus or Thrombus? A Case Report. Radiol Case Rep. 2023;18(8):2685-8. doi: 10.1016/j.radcr.2023.05.016.
    » https://doi.org/10.1016/j.radcr.2023.05.016

Study Association:

This study is not associated with any thesis or dissertation work.

Ethics Approval and Consent to Participate:

This article does not contain any studies with human participants or animals performed by any of the authors.

Sources of Funding:

There were no external funding sources for this study.

Mailing Address:

Mariana Ribas Laranjeira • Unidade Local de Saúde Gaia/Espinho. R. Conceição Fernandes, S/N. Postal Code: 4434-502. Vila Nova de Gaia – Portugal E-mail: mariribaslaranjeira@gmail.com

Potential Conflict of Interest:

No potential conflict of interest relevant to this article was reported.

Editor responsible for the review:

Andrea Vilela

Publication Dates

  • Publication in this collection
    20 Oct 2025
  • Date of issue
    2025

History

  • Received
    8 Aug 2024
  • Reviewed
    18 Oct 2024
  • Accepted
    7 Dec 2024
location_on
Departamento de Imagem Cardiovascular da Sociedade Brasileira de Cardiolodia (DIC/SBC) Av. Marechal Câmara, 160, 3º andar, Sala: 330 - Centro. CEP: 20020-907. , Telefone: +55 (21) 3478-2700 - Rio de Janeiro - RJ - Brazil
E-mail: abcimaging@cardiol.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo