Abstract

SENA, Ana Claudia Borges dos Santos; RIBEIRO, Sérgio Pinto; CONDESSA, Robledo Leal  and  VIEIRA, Sílvia Regina Rios. Expiratory positive airway pressure in postoperative cardiac hemodynamics. Arq. Bras. Cardiol. [online]. 2010, vol.95, n.5, pp.594-599.  Epub Sep 24, 2010. ISSN 0066-782X.  https://doi.org/10.1590/S0066-782X2010005000128.

BACKGROND: Expiratory positive airway pressure (EPAP) is used in after cardiac surgeries. However, its hemodynamic effects have not been clearly studied. OBJECTIVE: To evaluate the hemodynamic changes caused by EPAP in patients after cardiac surgery monitored by Swan-Ganz. METHODS: Patients at the first or second cardiac surgery postoperative period hemodynamically stable with a Swan-Ganz catheter were included in the study. They were assessed at rest and after using 10 cmH2O EPAP at random. The variables studied were: oxygen saturation, heart rate and respiratory rate, mean artery pressures and pulmonary artery mean pressures (MAP and PAMP), central venous pressure (CVP) and pulmonary capillary wedge pressure (PAOP), cardiac output and index, and systemic and pulmonary vascular resistances. Patients were divided into subgroups (with ejection fraction <; 50% or > 50%) and data were compared by t test and ANOVA. RESULTS: Twenty-eight patients were studied (22 men, aged 68 ± 11 years). Comparing the period of rest versus EPAP, the changes observed were: PAOP (11.9 ± 3.8 to 17.1 ± 4.9 mmHg, p < 0.001), PVC (8.7 ± 4.1 to 10.9 ± 4.3 mmHg, p = 0.014), PAMP (21.5 ± 4.2 to 26.5 ± 5.8 mmHg, p < 0.001), MAP (76 ± 10 for 80 ± 10 mmHg, p = 0.035). The other variables showed no significant differences. CONCLUSION: EPAP was well tolerated by patients and the hemodynamic changes found showed an increase in pressure measurements of right and left ventricular filling, as well as mean arterial pressure.

Keywords : Positive pressure respiration; hypertension; cardiac output; facial masks; thoracic surgery.

        · abstract in Portuguese     · text in Portuguese     · English ( pdf ) | Portuguese ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License