vol.14 issue2Applications of capillary electrophoresis to the analysis of compounds of clinical, forensic, cosmetological, environmental, nutritional and pharmaceutical importanceDetermination of catecholamines in pharmaceutical formulations using a biosensor modified with a crude extract of fungi laccase (Pleurotus ostreatus) author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

Share


Journal of the Brazilian Chemical Society

Print version ISSN 0103-5053On-line version ISSN 1678-4790

Abstract

BORGES, Daniel L. G.; DIAS, Lúcia F.; VEIGA, Márcia A. M. S. da  and  CURTIUS, Adilson J.. Determination of cadmium in sediments and in sewage sludge by slurry sampling electrothermal atomic absorption spectrometry using iridium as permanent modifier. J. Braz. Chem. Soc. [online]. 2003, vol.14, n.2, pp.291-296. ISSN 1678-4790.  https://doi.org/10.1590/S0103-50532003000200017.

A procedure for the determination of Cd in sediment and sewage sludge as slurries by electrothermal atomic absorption spectrometry is proposed. The slurry, 1 mg mL-1, was prepared by mixing sample ground to a particle size £ 50 mm with 5% v/v nitric acid in an ultrasonic bath. The homogeneity of the slurries was assured by passing a constant flow of argon into the autosampler cup, just before transferring an aliquot to the graphite furnace. Two permanent modifiers deposited on the platform were tested: Ru and Ir. Modifiers in solution were also tested: Pd plus Mg and phosphate alone or plus Mg. The Ir-treated tube was adopted due to its good performance as modifier and also for practical reasons. About 80% of Cd is extracted to the water phase of the slurry. To test the accuracy of the method, three certified materials were analyzed: a marine sediment, a river sediment and a domestic sewage sludge. The concentrations obtained, using calibration against aqueous standards prepared in the same medium as the slurries, are in agreement with the certified values, at a confidence level of 95%, according to the Student-t test. The limit of detection (3s) was 43 ng g-1 in the solid sample and the relative standard deviation for the sediment MESS-2 was 2.3% (n = 10).

Keywords : cadmium, slurry; ET AAS; modifier; sediment; sewage sludge.

        · abstract in Portuguese     · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License