The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity’s profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.

Dental cavity preparation; Technology, dental; Ultrasonography; Diamond


O objetivo deste estudo foi avaliar o formato dos preparos cavitários realizados com o sistema CVDentus® utilizando potências variadas do ultra-som. Uma cavidade padronizada foi realizada na face vestibular de 15 incisivos bovinos utilizando as pontas cilíndricas CVDentus® (82142). A amostra foi dividida em 3 grupos: G1 - ultra-som com potência II; G2 - ultra-som com potência III; e G3 - ultra-som com potência IV. Foi utilizada uma máquina padronizadora de preparos cavitários e o ultra-som foi aplicado durante 1 minuto em cada preparo. As cavidades foram seccionadas no centro, permitindo a visualização do perfil cavitário em uma lupa estereoscópica, e esse foi medido em largura e profundidade por meio do programa Leica Qwin. O teste estatístico Kruskal-Wallis (p < 0,05) e o método de Dunn demonstraram diferenças entre os formatos das cavidades produzidas com as potências III e IV. Entretanto, as cavidades realizadas com a potência III apresentaram dimensões semelhantes às da ponta utilizada. Concluiu-se que a potência indicada pelo fabricante (III) é a mais adequada para uso do sistema CVDentus®.

Preparo da cavidade dentária; Tecnologia odontológica; Ultrassonografia; Diamante


ORIGINAL ARTICLES

RESTORATIVE DENTISTRY

Influence of the power level of an ultra-sonic system on dental cavity preparation

Influência do nível de potência de um sistema de ultra-som em preparos cavitários

Érika Botelho JosgrilbergI; Murilo de Sousa GuimarãesI; Cyneu Aguiar PansaniII; Rita de Cássia Loiola CordeiroII

IGraduate Students – Department of Pediatrics, School of Dentistry of Araraquara, São Paulo State University

IIAssociate Professors – Department of Pediatrics, School of Dentistry of Araraquara, São Paulo State University

Corresponding author Corresponding author: Rita de Cássia Loiola Cordeiro Departamento de Clínica Infantil R. Humaitá, 1680 Araraquara - SP - Brazil CEP: 14801-903 E-mail: ritacord@foar.unesp.br

ABSTRACT

The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 – ultrasound with power II; G2 – ultrasound with power III; and G3 – ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity’s profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.

Descriptors: Dental cavity preparation; Technology, dental; Ultrasonography; Diamond.

RESUMO

O objetivo deste estudo foi avaliar o formato dos preparos cavitários realizados com o sistema CVDentus® utilizando potências variadas do ultra-som. Uma cavidade padronizada foi realizada na face vestibular de 15 incisivos bovinos utilizando as pontas cilíndricas CVDentus® (82142). A amostra foi dividida em 3 grupos: G1 – ultra-som com potência II; G2 – ultra-som com potência III; e G3 – ultra-som com potência IV. Foi utilizada uma máquina padronizadora de preparos cavitários e o ultra-som foi aplicado durante 1 minuto em cada preparo. As cavidades foram seccionadas no centro, permitindo a visualização do perfil cavitário em uma lupa estereoscópica, e esse foi medido em largura e profundidade por meio do programa Leica Qwin. O teste estatístico Kruskal-Wallis (p < 0,05) e o método de Dunn demonstraram diferenças entre os formatos das cavidades produzidas com as potências III e IV. Entretanto, as cavidades realizadas com a potência III apresentaram dimensões semelhantes às da ponta utilizada. Concluiu-se que a potência indicada pelo fabricante (III) é a mais adequada para uso do sistema CVDentus®.

Descritores: Preparo da cavidade dentária; Tecnologia odontológica; Ultrassonografia; Diamante.

Introduction

The use of ultrasound in dentistry was first introduced over fifty years ago for the preparation of cavities.2 The instrument was considered efficient for cutting hard dental tissue due to its precise cut, the soft aspect of the cavities obtained and its good tolerance by patients.8 However, some limitations in its use, such as a slow cut, the insufficient removal of tissue or weak materials, the need for constant maintenance and its high cost, have restricted the recommendations for its use and, consequently, it has had a low acceptance by professionals.10

During the years, this technology has been adapted for modern Dentistry needs, introducing water irrigation and adequate drill oscillation. Currently, it is used for endodontic, surgical, TMJ dysfunction, periodontic and other dental treatments, besides its application with the CVDentus® drill.

The CVDentus® system is a new Brazilian technology that is innovating the procedure of dental cavity preparation. The diamond bur is obtained by a chemical deposition of gas over a molybdenum stem, forming a unique diamond stone. This process results in an instrument that presents high durability, structural stability and biocompatibility, without forming dentine residues or contaminating the tooth with metal.1,9,11,13 Its adaptation for ultrasound adds to its advantages, providing improved visibility, low noise and often discarding the need for local anesthesia, promoting more comfort and facilitating the treatment for patients and for the operator.3,13

These tips are available in different shapes, and each one demands an adequate ultrasound power to reach greater effectiveness of cut and durability. However, there is no standardization with regard to the recommended power level for the various ultrasound systems available on the marketplace, thus requiring adaptations for their use. Usually, the power is increased to retain the effectiveness of cut. However, there is a need for professional training for the use of this technology since it operates in a different way than do conventional rotary devices, which seem to cut more quickly, causing a false impression that there is a need to increase the power of the ultrasound.

The aim of this in vitro study was to characterize the effect of the variation in ultrasound power level on dental cavity morphology.

Material and Methods

This study was approved by the Ethics and Research Comittee, School of Dentistry of Araraquara, São Paulo State University (protocol n.71/03).

Fifteen bovine incisors without caries injuries, cracks or anomalies observed by a magnifying glass (10 X) were used in this study. The crowns were divided and embedded in a block-type PVC pipe filled with resin (Ortoclass® - Clássico Ltda., Campo Limpo Paulista, SP, Brazil). Standardization of the crown fragment position in the PVC pipe was made using a glass slide/blade with a mark corresponding to the central region of the tooth, providing the ideal position for the crown in the PVC tube (Figure 1). The samples were then divided into three randomized groups, corresponding to each power level used with the ultrasound equipment (power II, power III and power IV – n = 10). Dental cavity preparations were performed with the CVDentus® system (Clorovale Diamantes - São José dos Campos, SP, Brazil) using a cylindrical drill (model 82142) connected to a Prof I ultrasound equipment (AS Ceramic - Dabi Atlante®, Ribeirão Preto, SP, Brazil) set at power levels II, III or IV, equivalent to 50%, 75% and 100% of the device’s total power.


A standard device, produced exclusively for this type of study, was used for dental cavity preparation;7 the cuts were made with 63 consecutive movements of the bur on the dental surface with a speed of 5.3 mm/s, corresponding to 1 minute of use of the CVDentus® tips (Figure 2A and Figure 2B).


The cavities were sectioned in the middle along the cervical-incisal plane and in their extremities to obtain two plane aspects of cavity profile for adaptation onto the Stereoscopic Magnifying glass (Leica, Carl Zeiss, Jena 16 X, Bensheim, Germany) to allow visualization of the cavity profiles, totaling 10 cavity profiles for each group (n = 10). The images were captured using the Leica Qwin Program (Leica Q550IW, Bensheim, Germany), and two tracings were made corresponding to width and depth of the cavity preparation. The program then gave out the measurements corresponding to width and depth. These measurements were performed twice for each sample, with an interval of one week between each other.

The cavity preparation images were visually analyzed by the examiner and classified according to the position of the pulp wall, and to whether it was finished in dentine, enamel or both.

All values obtained were transferred to the Biostat program, where the Spearman Correlation test was applied for examiner calibration verification. Statistical analysis was performed by the Kolmogorov-Smirnov normality test and the Kruskal-Wallis test (5% significance), to assess possible differences between the groups. The Dunn method was used to assess the difference between the ranks, when necessary.

Results

The results of the Spearman Correlation Test (5% significance) demonstrated that there was no significant differences between the two measurements, allowing the use of the first examination for the continuity of statistical analysis.

Differences in the cutting depths and widths, as demonstrated by the Kruskal-Wallis test, are presented in Table 1.

The Dunn method demonstrated that statistical difference occurred in both the depth and width of the dental cavities when the power levels II vs. IV and III vs. IV were compared (Graph 1).


The cut measurements for each of the experimental conditions are summarized in Table 2.

Visual cavity wall analysis demonstrated that all cavities had only reached the enamel (Figure 3).


Discussion

The association of ultrasound with the CVDentus® bur is not yet used on a daily clinical basis since the use and capabilities of the technique are widely unknown to professionals and researchers. The system may be used for dental cavity preparation, but the use of adequate power is important to provide an efficient cut and greater durability of the instrument.

A different power level for each tip model is recommended by the manufacturer, since each one promotes a different amplification of the ultrasound up to its extremity. For example, the system adapted for fine conical tips requires a power level of 30% due to the intense vibration produced. Although spherical tips are thicker, they exert an impact only at one point, causing great force in the connecting rod, disabling any power greater than 50%. Therefore, when using the system, care is required with regard to the choice of tip design and power level in order to allow greater effectiveness of cut and safety for the procedure.

Indicated power levels for each tip format are in the manual’s instructions for the system. However, some ultrasound devices present power levels that do not coincide with those indicated by the manufacturer.

The aim of this study was to assess the effect of ultrasound power variation on the morphology of the obtained cavity preparation, using a CVDentus® system cylindrical bur. This model was chosen because it is widely used in Pediatric Dentistry. Previous studies have shown that this tip presents great stability when comparing the shape of dental cavities in dentine and enamel.7

According to the manufacturer, the cylindrical tip must be used with 60% of the maximum ultrasound power. The equipment used in this research presented power levels of 25%, 50%, 75% and 100%. As our objective was to evaluate powers above and below the suggested average, we opted to use 50% (Group 1- power II), 75% (Group 2 - power III) and 100% (Group 3 - power IV) of the maximum power.

The methodology used for obtaining dental cavities was performed previously by Lima et al.7 (2006), and measurements were made using the Leica Qwin program. According to the Spearman Correlation test, no differences were observed between the first and second examinations, demonstrating the reliability of the methodology applied.

The Kruskal-Wallis test demonstrated significant differences between the three groups (Table 1). The Dunn method (Graph 1) demonstrated that these differences occurred between the group where power IV was used when compared to powers III and II.

Unexpectedly, this study did not find any statistically significant differences between powers II and III. This result may have occurred due to an absence of variation during the transmission of power or, possibly, because a threshold may exist above which the system becomes more effective.

In addition, the group in which power III was used demonstrated a greater variation in data distribution. A supposed initial trepidation of the ultrasound on the tooth surfaces or a changeable inclination of specimen surfaces observed in the magnifying glass may be the reason for this variability.

When power III was used, the mean cavity width (Table 2) was more similar to the actual diameter of the bur (1.1 mm), thus our study agrees with the manufacturer’s recommendation for the use of this power level for the cylindrical tip. The association of this tip with ultrasound allows the professional to perform precise and consistent dental cavity preparations, since it does not cut beyond its size and can decrease the risk of undesireble damage. To that extent, we agree with Khambay, Walmsley4,5 (2000), who compared ultrasound equipment with conventional rotary instruments and observed that the former cut with more precision.

Wapington et al.14 (1995) compared different power levels of ultrasound used with a standardized load and different formats of conventional tips and observed that, regardless of tip format, an increase in power results in an increase in amplitude of vibration and, consequently, an increase in the cutting ability of the instrument. In this study, we also observed that when power was increased to level IV (100%), the width and depth measurements of the dental cavities were greater when compared to those resulting from the other ultrasound powers (Table 2). When power is increased beyond the ideal, the CVDentus® system may remove chips of substratum, and make cavities that are larger or deeper than desired.

Although it was not the intention of this study to perform other analyses, cracks were observed in some of the samples. However, it is not possible to determine whether these were due to the preparation with the CVDentus® system or from the sectioning of the cavities for attainment of profile cavities for observation in the magnifying glass.

Effectiveness of cut studies show that rotary instruments cut faster than ultrasound.4,6,7,12 However, Khambay, Walmsley4 (2000) suggest that ultrasound cuts in a different manner and that the professional must be trained to use this instrument.

Power variation may cause alterations in cavity preparation size, in vibration and in the amount of noise, causing more discomfort to the patient and shorter tip durability, although, in this study no signs of frangibility or fracture of the bur were observed. Thus, it is important to obtain data regarding the adequate power levels for use with the CVDentus® system.

Ultrasound offers innumerous advantages for dental procedures. Moreover, the characteristics of ultrasound for use in Pediatric dentistry, such as comfort and the production of a noise that is different from that produced by rotary instruments, may contribute to obtain a more favorable behavior of children.

Conclusion

In this study, the dental cavity preparations made with power level IV were statistically different from those made with power levels II and III, suggesting that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.

Acknowledgements

The authors would like to thank Dr. José Sílvio Govone for the statistical advice given, and Dr. Evaldo José Corat for his support.

Received for publication on Dec 07, 2006

Sent for alterations on Jan 31, 2007

Accepted for publication on Mar 26, 2007

  • 1. Borges CFM, Magne P, Pfender E, Heberlein J. Dental diamond burs made with a new technology. J Prosthet Dent. 1999;82(1):73-9.
  • 2. Catuna MC. Sonic energy. A possible dental application. Preliminary report of an ultrasonic cutting method. Ann Dent. 1956;12(100):256-60.
  • 3. Conrado LA, Trava-Airoldi VJ, Corat E, Munin E, Rolim TS. The use of a CVD-Coated diamond bur coupled to an ultrasound handpiece in dental preparation [cited 2004 Oct 29]. Available from: http://www.cvd-diamante.com.br/ref-bibliograficas.htm
  • 4. Khambay BS, Walmsley AD. Investigations into the use of an ultrasonic chisel to cut bone. Part 1: forces applied by clinicians. J Dent. 2000;28(1):31-7.
  • 5. Khambay BS, Walmsley AD. Investigations into the use of an ultrasonic chisel to cut bone. Part 2: cutting ability. J Dent. 2000; 28(1):39-44.
  • 6. Lima LM, Motisuki C, Santos-Pinto L. Análise da efetividade de corte da ponta de diamante CVD em ultra-som e ponta diamantada convencional em alta-rotação [resumo]. Braz Oral Res. 2004;18(Suppl):128.
  • 7. Lima LM, Motisuki C, Santos-Pinto L, Santos-Pinto A, Corat EJ. Cutting characteristics of dental diamond burs made with CVD technology. Braz Oral Res. 2006;20(2):155-61.
  • 8. Postle HH. Ultrasonic cavity preparation. J Prosthet Dent. 1958;8(1):153-60.
  • 9. Silva AP, Menezes MM, Araújo RM. Influência da limpeza e esterilização sobre a capacidade de desgaste de pontas diamantadas. J Bras Clin Odontol Int. 2002;6(33):239-45.
  • 10. Street EV. A critical evaluation of ultrasonics in dentistry. J Prosthet Dent. 1959;9(1):132-41.
  • 11. Valera MC, Ribeiro JF, Trava-Airoldi VJ, Corat EJ, Pena AF, Leite NF. Pontas de diamantes - CVD. RGO. 1996;44(2):104-8.
  • 12. Vieira ASB, Antunes LAA, Maia LC, Santos MPA, Primo LG. Efetividade da abrasão ultra-sônica versus alta rotação: estudo in vitro [resumo]. Braz Oral Res. 2004;18(Suppl):172.
  • 13. Vieira D, Vieira D. Pontas de diamante CVD: início do fim da alta rotação? [Brazilian edition] J Am Dent Assoc. 2002;5:307-13.
  • 14. Wapington M, Blunt L, Walmsley AD, Lumley PJ. Dental hard tissue cutting characteristics of an ultrasonic drill. Int J Mach Tools Manufact. 1995;35(2):339-43.
  • Corresponding author:

    Rita de Cássia Loiola Cordeiro
    Departamento de Clínica Infantil
    R. Humaitá, 1680
    Araraquara - SP - Brazil
    CEP: 14801-903
    E-mail:
  • Publication Dates

    • Publication in this collection
      19 Oct 2009
    • Date of issue
      Dec 2007

    History

    • Reviewed
      31 Jan 2007
    • Received
      07 Dec 2006
    • Accepted
      26 Mar 2007
    Sociedade Brasileira de Pesquisa Odontológica - SBPqO Av. Prof. Lineu Prestes, 2227, 05508-000 São Paulo SP - Brazil, Tel. (55 11) 3044-2393/(55 11) 9-7557-1244 - São Paulo - SP - Brazil
    E-mail: office.bor@ingroup.srv.br