Acessibilidade / Reportar erro

Internal carotid artery aneurysm mimicking normal-tension glaucoma

Aneurisma de carótida interna simulando glaucoma de pressão normal

ABSTRACT

Differentiating glaucomatous from nonglaucomatous optic disc cupping remains challenging. We present a case of a 48-year-old woman with an internal carotid aneurysm of approximately 3.5 mm × 6.5 mm that mimicked normal-tension glaucoma. The patient had a 2-year history of low vision acuity in her left eye and frontal oppressive headache. Owing to the carotid aneurysm, she developed an asymmetric vertical cup-to-disc ratio above 0.2, and marked inferotemporal neuronal rim loss and pallor of the residual rim were noted in the left disc. She also developed a visual field defect with an arcuate scotoma in the left eye. The patient was referred to a neurosurgeon and underwent endovascular aneurysm occlusion. This case highlights the diagnostic importance of recognizing that many neurological defects remain underdiagnosed.

Keywords:
Glaucoma/diagnosis; Carotid artery, internal; Ophthalmic artery/pathology; Aneurysm/diagnosis; Visual field; Differential diagnosis

Conselho Brasileiro de Oftalmologia Rua Casa do Ator, 1117 - cj.21, 04546-004 São Paulo SP Brazil, Tel: 55 11 - 3266-4000, Fax: 55 11- 3171-0953 - São Paulo - SP - Brazil
E-mail: abo@cbo.com.br