Effects of aging methods on microleakage of an adhesive system used as a sealant on contaminated surfaces

Efeitos de métodos para envelhecimento na microinfiltração de um sistema adesivo usado como selante em superfícies contaminadas

Abstracts

This study evaluated the effects of aging methods on the microleakage of an adhesive system used for sealing pit and fissure surfaces. After acid etching, the occlusal surfaces of 60 permanent teeth were contaminated with 1mL of human plasma and then sealed with OptiBond dual cure, activated in the ramp mode (Optilux 501). The sample was then divided into eight experimental and a control groups. Aging was performed for 20 days in 5, 37, 55 and 5-55ºC (200 cycles/day) under water contact or not. After subjecting the specimens to the AgNO3 technique, they were sectioned twice. Dye penetration was measured and the mean values were subjected to ANOVA. No group provided hermetic seal against dye penetration, even the control group (without treatment). Significant aging x water interaction effect (p=0.033) was observed. The group without water contact at 5ºC (p=0.015) showed the least dye penetration value. The results led to the main conclusions: 1) all groups showed dye penetration, even the control group; 2) storage teeth at 5ºC on dry condition provided the lowest degree of dye penetration; 3) in the presence of water, the temperature variations seem not to affect the microleakage values.

Dentin-bonding agents; Dental leakage; Pit and fissures sealants


Este estudo avaliou os efeitos de métodos para envelhecimento na microinfiltração de um sistema adesivo usado para selar superfícies oclusais. Após o condicionamento com ácido, as superfícies de 60 dentes permanentes foram contaminadas com 1 mL de plasma e seladas com OptiBond dual cure, ativado pelo Optilux 501, no modo rampa. A amostra foi dividida em oito grupos experimentais e um grupo controle ou imediato O envelhecimento dos espécimes foi realizado por 20 dias a 5, 37, 55 e 5-55°C (200 ciclos/dia) em contato com a água ou não. Após submeter os espécimes à técnica de infiltração com AgNO3, eles foram secionados duas vezes e os valores médios da penetração do corante foram tratados por análise de variância. Nenhum grupo apresentou vedamento hermético na interface, nem mesmo o grupo sem envelhecimento (imediato ou controle). O grupo que permaneceu a 5°C sem contato com a água mostrou o menor grau de penetração (p=0,015) e a interação envelhecimento x água foi significante (p=0,033). Os resultados levam às seguintes conclusões: 1) todos os grupos mostram microinfiltração, inclusive o controle; 2) o grupo mantido a 5ºC sem contato com a água mostrou os menores valores de microinfiltração; 3) em contato com a água, as variações térmicas parecem não afetar o grau de penetração do corante.

Adesivos dentinários; Infiltração marginal; Selantes de fossas e fissuras


ORIGINAL ARTICLES

Effects of aging methods on microleakage of an adhesive system used as a sealant on contaminated surfaces

Efeitos de métodos para envelhecimento na microinfiltração de um sistema adesivo usado como selante em superfícies contaminadas

José Roberto de Oliveira BauerI; Alessandra ReisII; Alessandro Dourado LoguercioII; Lucia Pereira BarrosoIII; Rosa Helena Miranda GrandeIV

IMSc, PhD student, Department of Dental Materials, Dental School, University of São Paulo, SP, Brazil

IIPhD Professor, Department of Dental Materials and Operative Dentistry, University of Oeste de Santa Catarina (UNOESC), Joaçaba, SC, Brazil

IIIPhD, Professor, Department of Statistics, Institute of Mathematics and Statistics, University of São Paulo, SP, Brazil

IVPhD, Associate Professor, Department of Dental Materials, Dental School, University of São Paulo, SP, Brazil

Corresponding address Corresponding address: Rosa Helena Miranda Grande Faculdade de Odontologia Departamento de Materiais Dentários Av. Lineu Prestes, 2227 Cep.:05508-000 - São Paulo Brasil phone/fax: 11-30917840 E-mail: grande@usp.br

ABSTRACT

This study evaluated the effects of aging methods on the microleakage of an adhesive system used for sealing pit and fissure surfaces. After acid etching, the occlusal surfaces of 60 permanent teeth were contaminated with 1mL of human plasma and then sealed with OptiBond dual cure, activated in the ramp mode (Optilux 501). The sample was then divided into eight experimental and a control groups. Aging was performed for 20 days in 5, 37, 55 and 5-55ºC (200 cycles/day) under water contact or not. After subjecting the specimens to the AgNO3 technique, they were sectioned twice. Dye penetration was measured and the mean values were subjected to ANOVA. No group provided hermetic seal against dye penetration, even the control group (without treatment). Significant aging x water interaction effect (p=0.033) was observed. The group without water contact at 5ºC (p=0.015) showed the least dye penetration value. The results led to the main conclusions: 1) all groups showed dye penetration, even the control group; 2) storage teeth at 5ºC on dry condition provided the lowest degree of dye penetration; 3) in the presence of water, the temperature variations seem not to affect the microleakage values.

Uniterms: Dentin-bonding agents; Dental leakage; Pit and fissures sealants.

RESUMO

Este estudo avaliou os efeitos de métodos para envelhecimento na microinfiltração de um sistema adesivo usado para selar superfícies oclusais. Após o condicionamento com ácido, as superfícies de 60 dentes permanentes foram contaminadas com 1 mL de plasma e seladas com OptiBond dual cure, ativado pelo Optilux 501, no modo rampa. A amostra foi dividida em oito grupos experimentais e um grupo controle ou imediato O envelhecimento dos espécimes foi realizado por 20 dias a 5, 37, 55 e 5-55°C (200 ciclos/dia) em contato com a água ou não. Após submeter os espécimes à técnica de infiltração com AgNO3, eles foram secionados duas vezes e os valores médios da penetração do corante foram tratados por análise de variância. Nenhum grupo apresentou vedamento hermético na interface, nem mesmo o grupo sem envelhecimento (imediato ou controle). O grupo que permaneceu a 5°C sem contato com a água mostrou o menor grau de penetração (p=0,015) e a interação envelhecimento x água foi significante (p=0,033). Os resultados levam às seguintes conclusões: 1) todos os grupos mostram microinfiltração, inclusive o controle; 2) o grupo mantido a 5ºC sem contato com a água mostrou os menores valores de microinfiltração; 3) em contato com a água, as variações térmicas parecem não afetar o grau de penetração do corante.

Unitermos: Adesivos dentinários; Infiltração marginal; Selantes de fossas e fissuras.

INTRODUCTION

Whereas clinical trials are the best way to provide valuable information about the performance of dental materials17, they are expensive and time-consuming. Furthermore, it is likely that the products under investigation might be discontinued by the time the study is published.

Microleakage tests are often relied upon predictors of clinical performance for new generation adhesive-restorative approaches and materials. These tests usually include thermal cycling to simulate intraoral conditions1,17, which requires exposure of specimens to water baths set at temperatures that resemble those found in the oral cavity. The rationale behind this is that marginal percolation can be caused by differences in the coefficient of thermal expansion between dental tissues and the restorative material. The polymerization shrinkage, poor bonding of restorative materials to tooth tissues and coefficient of thermal expansion are blamed as the main factors for leakage17. One concern of the thermal cycling regimen is that the temperature variations between 5 and 55°C do not necessarily mean that this is the temperature variation that causes damages to the bonding interfaces11.

Apart from thermal stressing, the presence of water has been generally overlooked in microleakage studies. Bond breakdown may be enabled or facilitated by hydrolysis of the bonding agent and its union with tooth tissue17. It is widely known that water acts as plasticizer of polymers and reduces the marginal integrity of restorations2,3 being a stress-raising factor.

Pit and fissure sealing is a successful clinical procedure to prevent caries development and it is routinely indicated for teeth under caries risk5,12,24,26,28. Sometimes, the success of this technique is dependent on the application of the material during the teeth erupting stages. Under such clinical conditions the use of rubber dam6, to reduce the risk of contamination by saliva, crevicular fluid and/or blood is almost impossible10,15.

Microleakage and partial/total loss of sealants due to salivary contamination are the main concerns regarding their long-term success15. Therefore, adhesive systems have been proposed as an intermediate layer between enamel and sealants for minimizing deleterious effects of non detected moisture contamination, and such combination has being analyzed via in vitro15,16,22 and in vivo8 studies.

A more recent approach indicates the sole use of filled adhesive systems for sealing, mainly when contamination is likely to occur4,13,29. It was observed that OptiBond dual cure29 and OptiBond FL4 showed less microleakage values whether applied on contaminated enamel surfaces or not, compared to two conventional sealants (Delton and Fluroshield) and three adhesive systems (Scotchbond MP, All Bond and SOLO). This result was also maintained even when the specimens were subjected to thermal and/or load cycling4,29. To date, no study has separately addressed the effects of water and temperature changes on the marginal sealing, which was the main objective of the present investigation.

Therefore the objective of this study was to analyze the effects of water contact and aging methods on the marginal sealing of an adhesive system used as a sealant for contaminated condition.

MATERIALS AND METHODS

The Ethics Committee at Dental School, University of São Paulo, approved this study. Sixty caries-free extracted human molars and premolars, free of defects/fractures, were cleaned and immersed in a 10% formaldehyde solution for some days. After that they were stored in distilled water for no longer than 4 months. The roots and cervical region of crowns were embedded in acrylic resin and the teeth were pumiced and rinsed thoroughly with water using an ultrasonic cleaner (Thornton, Inpec Electronics, Vinhedo, SP, Brazil).

After surface conditioning with 32% phosphoric acid for 30 seconds (Uni-etch, Bisco Inc, Schaumburg, IL, USA; batch 9900010368), the sample was contaminated with 1 microliter of human plasma (Pharmaceutical School - University of São Paulo) for 30 seconds, followed by material application, as shown in Table 1. The OptiBond dual cure adhesive (SDS Kerr, Orange, CA, USA; batch 910068, 910A31 and 909D92) was light cured with an Optilux 501 curing unit (Demetron Res. Corp.; Danbury, CT, USA) under ramp mode with light intensity increasing from 100 to 1000 mW/cm2 in a period of 20s. The light intensity was checked using the own light curing unit radiometer.

The specimens were then allocated into the following groups: 1) thermocycling- 4,000 cycles, 200 per day, at 5 and 55ºC with a dwell time of 60 s in water environment; 2) thermocycling- 4,000 cycles, 200 per day, at 5 and 55ºC with a dwell time of 60 s without water contact; 3) storage in distilled water for 20 days at 5ºC (thermocycling duration time); 4) storage without water contact for 20 days at 5ºC; 5) storage in distilled water for 20 days at 37 ºC; 6) storage without water contact for 20 days at 37ºC; 7) storage in distilled water for 20 days at 55ºC; 8) storage without water contact for 20 days at 55ºC; 9) immediate or control group, with no aging treatment. All specimens, except those from the control group, were maintained immersed in water for 24 h. The experimental design is depicted in Figure 1.


The specimens contact with water was avoided by means of an individual custom tray, fabricated for each tooth from a 0.2 mm vacuum-formed soft plastic (Nite White, Discus Dental, LA, CA, USA). The custom tray was then glued to the acrylic resin surface with cyanoacrylate resin Super Bonder (Henkel Ltda., Itapevi, SP, Brazil), in order to avoid water penetration during the aging method and only allow temperature changes within tooth. In order to confirm if the temperature changed during thermocycling, a thermocouple was placed within the pulp chamber in some teeth and they were subjected to the thermocycling procedure, validating the method employed.

Subsequently, the crowns of the specimens from all groups were coated with three layers of nail varnish, except from the area 1 mm away from the adhesive interface, and immersed in a 50% AgNO3 aqueous solution (pH > 7.0) in darkness for 2 hours. Afterwards, they were rinsed off, immersed in a photo-developing solution and exposed to fluorescent light for 8 hours20.

Each specimen was sectioned twice, through the sealed fissure system, with a microtome (Labcut 1010, Extec Co., Enfield, MT, USA) in buccal-to-lingual direction generating 4 cross-sections per tooth that were digitized (ScanJet 4c, HP, Palo Alto, CA, USA) to obtain 600dpi TIFF images. On each cross-section the total linear interface between adhesive and enamel in the buccal and lingual slopes, as well as the extent of the dye penetration were measured (mm) with IMAGELAB (image analysis software developed at FOUSP, Brazil) and expressed as a percentage of the total adhesive interface length. For each tooth, the percentages of dye penetration along the cross-section interfaces were averaged.

An unbalanced ANOVA with empty cells was employed to evaluate the effects of the main effects as well as their interaction with respect to the mean value of leakage18. The significance level considered was 5%.

RESULTS

Table 2 contains the descriptive measurements per group and Figure 2 shows the mean profile plots with the respective standard errors.


The analysis of variance indicated significant aging methods x water interaction (p=0.033). It is worthwhile to note that the significant water x aging interaction suggests that the differences between the overall dye penetrations for the different methods depend on the storage condition (with water contact or not). The main factors, water (p=0.448) and aging (p=0.186), were not statistically significant.

The Tukey test for multiple comparisons was applied to the different combinations of aging methods and water. Eight of the thirty-six comparisons were statistically significant (considering the level of significance as 5%), five of them corresponding to storage at 5ºC with no water. Results of the Tukey test suggested that the overall dye penetration percentage for teeth stored at 5ºC with no water contact is smaller than that for the other methods, which were statistically equivalent. These findings were incorporated into a linear model, which confirmed the above results with statistically significant effect (p=0.015).

Under this approach, the overall dye penetration percentage from the group at 5ºC under no water contact was 15.9 ± 11.0 (mean ± standard error). For the other groups, the overall dye penetration percentage was 44.9 ± 3.7.

The measurements were repeated, some time later, for sixteen specimens and the intra-class correlation coefficient was calculated as a measure of reliability; the result was 0.81, indicating excellent agreement9.

DISCUSSION

The marginal integrity of the tooth/material interface is dependent upon many factors like the physical properties of the material and dental tissue, as well as their interactions with the environment23. It is well accepted that a clean, uncontaminated bonding field is mandatory for achieving effective adhesion to tooth structures5. The shrinkage that occurs as the material polymerize has been considered the main factor for bonding failures and it may lead to leakage around the restoration and subsequent secondary caries17. The linear coefficient of thermal expansion has been noted as other important contributing factor to leakage. However, in a clinical situation, the dimensional change may not be as great as the linear coefficient of the material would predict, once extreme temperatures seem to occur in short periods of time23. The clinical relevance of the linear coefficient has not been clarified yet11 since some time is required for a non uniform temperature body to approach the equilibrium11,23.

The results of many clinical trials and in vitro studies depicted the longevity and effectiveness profile of sealant technique12,15,24, although there are reports showing decreased retention rates over time12,15. The application of hydrophobic materials to acid-etched enamel susceptible to moisture contamination is likely the major cause of reduced retention of fissure sealants6,7,10,13,15. Therefore, the use of hydrophilic adhesive systems to seal fissures, followed15 or not13 by hydrophobic sealants, is of special interest since they could overcome the negative effects of some casual contamination during the bonding process6.

As in previous studies no significant differences between microleakage values for dry and contaminated condition were observed when OptiBond was used4,13,29. Based on that and in the fact that the use of an adhesive system as sealant is proposed in cases where there is risk of contamination, the authors of the present study decided not to use dry enamel condition.

The present results show that aging at 5ºC, without water contact, has an overall dye penetration value of 15.9 ± 11.0%. It is likely that the diffusion coefficient is lowest at 5ºC than at 35ºC and that the mobility of the polymer molecules are reduced25, which in turn may restrict the tracer penetration along polymer/enamel interface, since there is no water contact. Although at 5ºC in a dry condition lower microleakage was observed, it does not clinically simulate the oral environment. All other experimental groups, except the group maintained at 5ºC in a dry condition, showed overall leakages that were statistically similar (44.9 ± 3.7%). This implies that the microleakage degree taken from the control group was statistically similar to the specimens that were thermocycled or stored in one of the aging methods.

For instance, in a previous study29, the microlekage values of three adhesive systems applied for sealing occlusal surfaces after thermal cycling (4,000 times; 5-55ºC) were compared. The authors also kept some specimens in water at 37ºC for 72 hours, as control, to verify the interface integrity after a short storage time (to allow possible water sorption and residual polymerization). Under the control condition, dye penetration was observed for all materials regardless the contamination condition; OptiBond showed less overall leakage (11 ± 5%) than the other adhesives (21 ± 6%). After thermal cycling, OptiBond dual cure continued showing the least overall leakage value (28 ± 6%) than All Bond 2 and Scotchbond MP that showed similar values (38 ± 6%). This clearly indicates that microleakage adversely affected early defective interfaces; however, the overall conclusions were not affected by the thermocycling procedures.

As in the study described above, none of the experimental conditions from the present study achieved an initial complete seal. Therefore, it seems that there is no point in subjecting the specimens to thermal cycling. Apart from the thermal changes, other factors such as water sorption may take place and lead to misinterpretation of microleakage results. The effect of water as a polymer plasticizer has been currently overlooked in microleakage studies11,21 and its effects on thermal cycled specimens should be further evaluated.

The results regarding microleakage coincide with others described in the literature. Neither the storage at a constant temperature or under thermal cycling, nor the dwell period or the number and temperature of cycles seem to significantly affect microleakage11,14,20. No difference in microleakage between thermocycled and non-thermocycled groups were detected; breakdown and leakage have also been identified on non-thermocycled specimens interface19,23,27. The middle-term storage (3 months) and thermal cycling (500x, 10-60ºC) did not enhance the severity of the leakage since the worst values occurred in the immediate group30.

CONCLUSIONS

Considering the experimental design and the limitations of this study regarding a clinical situation simulating a contaminated sealed surface, it was concluded that: 1) all groups showed dye penetration, even the control group; 2) storage teeth at 5ºC on dry condition provided the lowest degree of dye penetration; 3) in the presence of water, variations seem not to affect the microleakage values.

ACKNOWLEDGMENTS

The authors appreciated the assistance of Dr. Moacir Novelli (LIDO - Informatics Laboratory Dedicated to Dentistry). This study was supported by the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq, 300086/01-6).

Received: February 01, 2005

Modification: May 10, 2005

Accepted: September 27, 2005

  • 1- Alani AH, Toh CG. Detection of microleakage around dental restorations: a review. Oper Dent. 1997;22:173-85.
  • 2- Burrow MF, Sato HM, Tagami J. Dentin bonding durability after three years using a dentin bonding agent with and without priming. Dent Mater. 1996;12:302-7.
  • 3- Carrilho MRO, Carvalho RM, Tay FR, Pashley DH. Effects of storage media on mechanical properties of adhesive systems. Am J Dent. 2003;17:104-8.
  • 4- Christino Neto P, Grande RHM, Toloi C, Doy FE, Singer JM. Leakage of adhesive systems used as a sealant in contaminated surfaces [abstract n. 98]. J Dent Res. 2001;80(sp. Issue):1011.
  • 5- Cueto EI, Buonocore MG. Sealing of pits and fissures with an adhesive resin: its use in caries prevention. J Am Dent Assoc. 1967;75:121-8.
  • 6- Dennison JB, Straffon LH, Moore FG. Evaluating tooth eruption on sealant efficacy. J Am Dent Assoc. 1990;121:610-4.
  • 7- Duangthip D, Lussi A. Microleakage and penetration ability of resin sealant versus bonding system when applied following contamination. Pediatr Dent. 2003;25:505-11.
  • 8- Feigal RJ, Musherure P, Gillespie B, Levy-Polack M, Quelhas I, Hebling J. Improved sealant retention with bonding agents: a clinical study of two-bottle and one-bottle systems. J Dent Res. 2000;79:1850-6.
  • 9- Fleiss JL. The design and analysis of clinical experiments. New York: John Wiley and Sons; 1986.
  • 10- Fuks AB, Edeilman E, Biton N, Shapira J. A comparison of the retentive properties of two filled resins used as fissure sealants. ASDC J Dent Child. 1982;49:127-30.
  • 11- Gale MS, Darvel BW. Thermal cycling procedures for laboratory testing of dental restorations. J Dent. 1999;27:89-99.
  • 12- Grande RHM, Singer JM, Myaki I. Retention of pit and fissure sealants on primary molars: effects of tooth age and prophylaxis techniques. J Okayama Dent Soc. 1990:339-43.
  • 13- Grande RHM, Ballester R, Singer JM, Santos JFF. Microleakage of a universal adhesive used as a fissure sealant. Am J Dent. 1998;11:109-13.
  • 14- Gwinnett JA, Tay FR, Pang KM, Wei SH. Comparison of three methods of critical evaluation of microleakage along restorative interfaces. J Prosthet Dent. 1995;74:575-85.
  • 15- Hebling J, Feigal RJ. Use of one-bottle adhesive as an intermediate bonding layer to reduce sealant microleakage on saliva-contaminated enamel. Am J Dent. 2000;13:187-91.
  • 16- Hitt J, Feigal RJ. Use of a bonding agent to reduce sealant sensitivity to moisture contamination: an in vitro study. Pediat Dent. 1992;14:41-6.
  • 17- Li H, Burrow MF, Tyas MJ. The effect of thermocycling regimens on the nanoleakage of dentin bonding systems. Dent Mater. 2002;18:189-96.
  • 18. Neter J, Kutner MH, Nachtshein, CJ, Wasserman W. Applied linear statistical models. 4ed. Chicago: Irwin; 1996.
  • 19- Pahini-Theodoridou S, Tolidis K, Papadogiannis Y. Degree of microleakage of some pit and fissure sealants: an in vitro study. Int J Paediatr Dent. 1996;6:173-6.
  • 20- Pintado MR, Douglas WH. The comparison of microleakage between two different dentin bonding resin systems. Quintessence Int. 1998;19:905-07.
  • 21- Price RB, Dérand T, Andreou P, Murphy D. The effect of two configuration factors, time, and thermal cycling on resin to dentin bond strengths. Biomaterials. 2003;24:1013-21.
  • 22- Rego MA, Araújo MA. Microleakage evaluation of pit and fissure sealants done with different procedures, material, and laser after invasive technique. J Clin Paediatr Dent. 1999;24:63-8.
  • 23- Rossomando KJ, Wendt Jr S. Thermocycling and dwell times in microleakage evaluation for bonded restorations. Dent Mater. 1995;11:47-51.
  • 24- Simonsen RJ. Retention and effectiveness of dental sealant after 15 years. J Am Dent Assoc. 1991;122:34-42.
  • 25- Soles CL, Yee AF. A discussion of the molecular mechanisms of moisture transport in epoxy resins. J Polymer Scien. Part 2, Polymer Physics 2000; 38:792-802.
  • 26-Vehkalahti MM, Solavaara L, Rytomaa I. An eight-year follow-up of the occlusal surfaces of first permanent molars. J Dent Res. 1991;70:1064-7.
  • 27- Xalabarde A, Garcia-Godoy F, Boj JR, Canalda C. Microleakage of fissure sealants after occlusal enameloplasty and thermoclycling. J Clin Pediatr Dent. 1998;22:231-5.
  • 28- Waggoner WF, Siegal M. Pit and fissure sealant application: updating the technique. J Am Dent Assoc. 1996;127:351-61.
  • 29- Witzel MF, Grande RHM, Singer JM. Bonding systems used for sealing: evaluation of microleakage. J Clin Dent. 2000;11:47-52.
  • 30- Yap AUJ, Pearson GJ, Billington RW, Stokes AN. An in vitro microleakage study of three restorative techniques for class II restorations in posterior teeth. Biomaterials. 1996;17:2031-5.
  • Corresponding address:

    Rosa Helena Miranda Grande
    Faculdade de Odontologia
    Departamento de Materiais Dentários
    Av. Lineu Prestes, 2227
    Cep.:05508-000 - São Paulo Brasil
    phone/fax: 11-30917840
    E-mail:
  • Publication Dates

    • Publication in this collection
      20 Jan 2006
    • Date of issue
      Dec 2005

    History

    • Accepted
      27 Sept 2005
    • Reviewed
      10 May 2005
    • Received
      01 Feb 2005
    Faculdade De Odontologia De Bauru - USP Serviço de Biblioteca e Documentação FOB-USP, Al. Dr. Octávio Pinheiro Brisolla 9-75, 17012-901 Bauru SP Brasil, Tel.: +55 14 32358373 - Bauru - SP - Brazil
    E-mail: jaos@usp.br