Acessibilidade / Reportar erro

Cross-cultural adaptation to Portuguese of tools for assessing the nutritional status of patients on dialysis

Abstracts

Introduction:

The 7 point subjective global assessment (7p-SGA) and the malnutrition inflammation score (MIS) are tools commonly applied for the assessment of nutritional status in dialyzed patients. Both were developed in English and require translation to Portuguese to be applied in Brazil. The cross-cultural equivalence process ensures semantic and measurement equivalence of a translated tool.

Objective:

To perform the cross-cultural adaptation to Portuguese of the 7p-SGA and MIS.

Methods:

Semantic equivalence was performed by the back-translation method and by assessing the degree of similarity between the original instrument and that back-translated from Portuguese to English (Back-translation). The assessment of the equivalence measurement was made by evaluating the intern reliability (Cronbach's α) and interobserver reliability (two observers). One-hundred and one elderly patients on hemodialysis (HD) were included.

Results:

Both instruments showed a high degree of semantic similarity with results close to the maximum value (7p-SGA 96.8 ± 7.8 and MIS 99.6 ± 1.4). The intern consistency showed a Cronbach's α value for 7p-SGA of 0.72 and of 0.53 for MIS. The interobserver reproducibility of 7p-SGA was moderate (intraclass coefficient [ICC] = 0.74 [95% CI: 0.58; 0.84]), while for MIS was strong (ICC = 0.88 [95% CI: 0.81; 0.93]).

Conclusion:

The 7p-SGA and MIS translated into Portuguese can be applied for assessing the nutritional status of elderly patients on HD. Studies testing the applicability of these instruments in adult patients on HD and in peritoneal dialysis should yet be performed.

dialysis; malnutrition; nutrition assessment


Introdução:

A avaliação global subjetiva de 7 pontos (AGS-7p) e o malnutrition inflammation score (MIS) constituem métodos de avaliação nutricional comumente empregados em pacientes em diálise. Ambos foram desenvolvidos na língua inglesa, de forma que é necessária a tradução para o português. O processo de adaptação transcultural garante a equivalência semântica e de mensuração de instrumentos traduzidos.

Objetivo:

Realizar a adaptação transcultural para o português da AGS-7p e do MIS.

Métodos:

A equivalência semântica foi feita pelo método da retrotradução e pela avaliação do grau de similaridade entre o instrumento original em inglês e o retraduzido do português para o inglês (retrotradução). A avaliação da equivalência de mensuração foi feita pela medida de confiabilidade interna (α de Cronbach) e pela reprodutibilidade interavaliador (dois avaliadores). Para tanto, 101 pacientes idosos em hemodiálise (HD) foram avaliados.

Resultados:

Ambos os instrumentos apresentaram alto grau de similaridade semântica e próximo ao valor máximo (AGS-7p 96,8 ± 7,8 e MIS 99,6 ± 1,4). A consistência interna apresentou valor de α de Cronbach para a AGS-7p de 0,72 e para o MIS de 0,53. A reprodutibilidade interavaliador da AGS-7p foi moderada e para e do MIS foi forte (coeficiente intraclasse = 0,74 [95% IC: 0,58; 0,84] e 0,88 [95% IC: 0,81; 0,93], respectivamente).

Conclusão:

A AGS-7p e MIS traduzidos para o português estão aptos para o emprego em pacientes idosos em HD. Estudos que testem a aplicabilidade dessas versões em pacientes adultos em HD e em diálise peritoneal devem ser feitos.

avaliação nutricional; desnutrição; diálise


Introduction

Nutritional status assessment is important in the care of patients with chronic kidney disease (CKD). International treatment guides for patients with CKD as the National Kidney Foundation/Clinical Practices Guidelines for Chronic Kidney Disease (Nutrition) (Nutrition K/DOQI),11. Clinical practice guidelines for nutrition in chronic renal failure. K/DOQI, National Kidney Foundation. Am J Kidney Dis 2000;35:S1-140. the European Best Practice Guidelines in Nutrition (EBPG),22. Fouque D, Vennegoor M, ter Wee P, Wanner C, Basci A, Canaud B, et al. EBPG guideline on nutrition. Nephrol Dial Transplant 2007;22:ii45-87. DOI: http://dx.doi.org/10.1093/ndt/gfm020
http://dx.doi.org/10.1093/ndt/gfm020...
as well as the Nutritional Therapy Guidelines for Hemodialysis Patients of the Brazilian Society of Parenteral and Enteral Nutrition (SBNPE),33. Martins C, Cuppari L, Avesani C, Gusmão MG. Terapia Nutricional para Pacientes em Hemodiálise Crônica. In: Projeto Diretrizes da AMB/SBNPE/Nutrologia. São Paulo: Associação Médica Brasileira; 2011.p.1-10. recommend the use of objective and subjective methods to assess nutritional status, in order to obtain a more accurate nutritional diagnosis.

The most used objective methods to assess the nutritional status of CKD patients in clinical practice include anthropometry, bioelectrical impedance, handgrip strength, feed intake data and laboratorial tests.11. Clinical practice guidelines for nutrition in chronic renal failure. K/DOQI, National Kidney Foundation. Am J Kidney Dis 2000;35:S1-140.

2. Fouque D, Vennegoor M, ter Wee P, Wanner C, Basci A, Canaud B, et al. EBPG guideline on nutrition. Nephrol Dial Transplant 2007;22:ii45-87. DOI: http://dx.doi.org/10.1093/ndt/gfm020
http://dx.doi.org/10.1093/ndt/gfm020...
-33. Martins C, Cuppari L, Avesani C, Gusmão MG. Terapia Nutricional para Pacientes em Hemodiálise Crônica. In: Projeto Diretrizes da AMB/SBNPE/Nutrologia. São Paulo: Associação Médica Brasileira; 2011.p.1-10. With respect to the combined methods for assessing nutritional status, Subjective Global Assessment (SGA) and the Malnutrition and Inflammation Score (MIS) are the most commonly used subjective instruments in this group of patients.44. Steiber AL, Kalantar-Zadeh K, Secker D, McCarthy M, Sehgal A, McCann L. Subjective Global Assessment in chronic kidney disease: a review. J Ren Nutr 2004;14:191-200. DOI: http://dx.doi.org/10.1016/S1051-2276(04)00139-6
http://dx.doi.org/10.1016/S1051-2276(04)...

SGA is considered an instrument that encompasses subjective and objective aspects of the physical and clinical history of the patient and can be applied by any properly trained health care professional.44. Steiber AL, Kalantar-Zadeh K, Secker D, McCarthy M, Sehgal A, McCann L. Subjective Global Assessment in chronic kidney disease: a review. J Ren Nutr 2004;14:191-200. DOI: http://dx.doi.org/10.1016/S1051-2276(04)00139-6
http://dx.doi.org/10.1016/S1051-2276(04)...
This tool is recommended by the Nutrition-K/DOQI, the EBPG and the SBNPE for the nutritional assessment of patients in dialysis.11. Clinical practice guidelines for nutrition in chronic renal failure. K/DOQI, National Kidney Foundation. Am J Kidney Dis 2000;35:S1-140.

2. Fouque D, Vennegoor M, ter Wee P, Wanner C, Basci A, Canaud B, et al. EBPG guideline on nutrition. Nephrol Dial Transplant 2007;22:ii45-87. DOI: http://dx.doi.org/10.1093/ndt/gfm020
http://dx.doi.org/10.1093/ndt/gfm020...
-33. Martins C, Cuppari L, Avesani C, Gusmão MG. Terapia Nutricional para Pacientes em Hemodiálise Crônica. In: Projeto Diretrizes da AMB/SBNPE/Nutrologia. São Paulo: Associação Médica Brasileira; 2011.p.1-10. SGA was originally developed by Detsky et al.,55. Detsky AS, Baker JP, Mendelson RA, Wolman SL, Wesson DE, Jeejeebhoy KN. Evaluating the accuracy of nutritional assessment techniques applied to hospitalized patients: methodology and comparisons. JPEN J Parenter Enteral Nutr 1984;8:153-9. DOI: http://dx.doi.org/10.1177/0148607184008002153
http://dx.doi.org/10.1177/01486071840080...
in 1984, with the aim of assessing the nutritional status of surgical patients. According to the final outcome of the instrument, nutritional status is classified as: (A) Well Nourished; (B) Mildly to Moderately Malnourished, or (C) Severely Malnourished. Since then, this instrument has been redesigned by researchers in diverse populations with the goal to increase its reproducibility and predictive value.66. Barbosa-Silva MCG, Barros AJD. Avaliação nutricional subjetiva: Parte 2 - Revisão de suas adaptações e utilizações nas diversas especialidades clínicas. Arq Gastroenterol 2002;39:248-52.

The first SGA validation for patients on hemodialysis (HD) and peritoneal dialysis (PD) was performed by Enia et al.,77. Enia G, Sicuso C, Alati G, Zoccali C. Subjective global assessment of nutrition in dialysis patients. Nephrol Dial Transplant 1993;8:1094-8. in 1993, demonstrating that patients with protein energy malnutrition (PEM) diagnosed by SGA had lower values of albumin, low body fat content, short arm muscle circumference and low protein intake when compared to well-nourished patients. Subsequently, a multicenter study involving patients on PD proposed an expansion to the nutritional status classification scale of the original SGA (A, B and C) to 7 points (SGA-7p), in which the lower the number of points, the greater the degree of malnutrition. The results showed a strong association between nutritional status deterioration and increased mortality, in which a 1-point reduction in the SGA-7p was associated with a 25% increase in mortality likelihood.88. Adequacy of dialysis and nutrition in continuous peritoneal dialysis: association with clinical outcomes. Canada-USA (CANUSA) Peritoneal Dialysis Study Group. J Am Soc Nephrol 1996;7:198-207.

In 2007, the SGA-7p has been validated for patients on HD by Steiber et al.,99. Steiber A, Leon JB, Secker D, McCarthy M, McCann L, Serra M, et al. Multicenter study of the validity and reliability of subjective global assessment in the hemodialysis population. J Ren Nutr 2007;17:336-42. DOI: http://dx.doi.org/10.1053/j.jrn.2007.05.004
http://dx.doi.org/10.1053/j.jrn.2007.05....
through concurrent validation with objective measures of nutritional status. In another study, also using the SGA-7p, it was shown that patients on dialysis (HD and PD) classified as malnourished had a higher mortality risk.1010. de Mutsert R, Grootendorst DC, Boeschoten EW, Brandts H, van Manen JG, Krediet RT, et al. Subjective global assessment of nutritional status is strongly associated with mortality in chronic dialysis patients. Am J Clin Nutr 2009;89:787-93. PMID: 19144733 DOI: http://dx.doi.org/10.3945/ajcn.2008.26970
http://dx.doi.org/10.3945/ajcn.2008.2697...
After these studies, several others have employed SGA-7p to assess the nutritional status of patients with CKD.1111. Vero LM, Byham-Gray L, Parrott JS, Steiber AL. Use of the subjective global assessment to predict health-related quality of life in chronic kidney disease stage 5 patients on maintenance hemodialysis. J Ren Nutr 2013;23:141-7. DOI: http://dx.doi.org/10.1053/j.jrn.2012.03.003
http://dx.doi.org/10.1053/j.jrn.2012.03....

12. Tsai HJ, Tsai AC, Hung SY, Chang MY. Comparing the predictive ability of population-specific Mini-Nutritional Assessment with Subjective Global Assessment for Taiwanese patients with hemodialysis: a cross-sectional study. Int J Nurs Stud 2011;48:326-32. PMID: 20817182 DOI: http://dx.doi.org/10.1016/j.ijnurstu.2010.07.015
http://dx.doi.org/10.1016/j.ijnurstu.201...
-1313. de Mutsert R, Grootendorst DC, Indemans F, Boeschoten EW, Krediet RT, Dekker FW; Netherlands Cooperative Study on the Adequacy of Dialysis-II Study Group. Association between serum albumin and mortality in dialysis patients is partly explained by inflammation, and not by malnutrition. J Ren Nutr 2009;19:127-35. DOI: http://dx.doi.org/10.1053/j.jrn.2008.08.003
http://dx.doi.org/10.1053/j.jrn.2008.08....

In 2001, Kalantar-Zadeh et al.1414. Kalantar-Zadeh K, Kopple JD, Block G, Humphreys MH. A malnutrition-inflammation score is correlated with morbidity and mortality in maintenance hemodialysis patients. Am J Kidney Dis 2001;38:1251-63. PMID: 11728958 DOI: http://dx.doi.org/10.1053/ajkd.2001.29222
http://dx.doi.org/10.1053/ajkd.2001.2922...
modified the original SGA and proposed a modified version called dialysis malnutrition score which subsequently gave rise to the malnutrition inflammation score (MIS). The MIS is a tool that results in a score between 0 and 30 points, in which 70% of the issues are common to the SGA and the rest are objective components such as albumin, total iron binding capacity (TIBC) and body mass index (BMI). In MIS, the higher the score, the worse the nutritional status. In studies including HD patients, it was shown that values indicative of malnutrition were associated with increased risk of hospitalizations and mortality.1414. Kalantar-Zadeh K, Kopple JD, Block G, Humphreys MH. A malnutrition-inflammation score is correlated with morbidity and mortality in maintenance hemodialysis patients. Am J Kidney Dis 2001;38:1251-63. PMID: 11728958 DOI: http://dx.doi.org/10.1053/ajkd.2001.29222
http://dx.doi.org/10.1053/ajkd.2001.2922...

A particularity of SGA-7p and the MIS is that, although they are widely used and having been validated for patients for HD, they are originally available in English. Thus, to use it in our country, it would be necessary to make a cultural adaptation of the instrument, including its careful translation into Portuguese. Such approach is important, since the simple translation into a foreign language can compromise the quality of the translated instrument.1515. Reichenheim ME, Moraes CL. Operationalizing the cross-cultural adaptation of epidemiological measurement instruments. Rev Saude Publica 2007;41:665-73.

The cross-cultural term adaptation is a process that first includes the stages of translation and cultural adaptation of an instrument for use in another country, so that the original and translated instruments have semantic equivalence.1616. Beaton DE, Bombardier C, Guillemin F, Ferraz MB. Guidelines for the process of cross-cultural adaptation of self-report measures. Spine (Phila Pa 1976) 2000;25:3186-91. DOI: http://dx.doi.org/10.1097/00007632-200012150-00014
http://dx.doi.org/10.1097/00007632-20001...
This initial step is the basis for assessing the equivalence measurement, another stage of cultural adaptation, which involves evaluating the reliability and validity of the translated instrument.1515. Reichenheim ME, Moraes CL. Operationalizing the cross-cultural adaptation of epidemiological measurement instruments. Rev Saude Publica 2007;41:665-73. Thus, the process of cultural adaptation seeks, above all, that the translated instrument produces an effect similar to the original so that it can be used safely in another culture.

Thus, if we consider that the SGA-7p and MIS are important tools for assessing the nutritional status of patients with CKD and that they have not gone through a process of cultural adaptation, this study aims to carry out a cross-cultural adaptation of the English language into Portuguese for these two instruments.

Patients and Methods

This study is observational and sectional, inserted into a larger research project that aims to assess the nutritional status of elderly patients on chronic HD. For the present study, our sample had 101 patients on chronic HD treatment from 5 dialysis centers in the city of Rio de Janeiro. The eligibility criteria include: age > 60 years, HD treatment lasting for more than 3 months under dialysis three times per week on alternate days, with each session lasting 3-4 hours. Elderly institutionalized individuals; wheelchair patients with amputated limbs; patients with cancer, human immunodeficiency virus (HIV) syndrome, Alzheimer's and Parkinson's disease were not included. This project was approved by the Ethics in Research Committee of the State University of Rio de Janeiro and all participants signed a Consent Form.

The process of cultural adaptation was performed by means of semantic equivalence and measurement equivalence,1717. Herdman M, Fox-Rushby J, Badia X. A model of equivalence in the cultural adaptation of HRQoL instruments: the universalist approach. Qual Life Res 1998;7:323-35.,1818. Hilton A, Skrutkowski M. Translating instruments into other languages: development and testing processes. Cancer Nurs 2002;25:1-7. DOI: http://dx.doi.org/10.1097/00002820200202000-00001
http://dx.doi.org/10.1097/00002820200202...
as illustrated in Figure 1.

Figure 1
Transcultural adaptation process by semantic and measurement equivalence

Semantic equivalence

The first phase of the process was the translation of the SGA-7p and the MIS from English into Portuguese using the back-translation method.1818. Hilton A, Skrutkowski M. Translating instruments into other languages: development and testing processes. Cancer Nurs 2002;25:1-7. DOI: http://dx.doi.org/10.1097/00002820200202000-00001
http://dx.doi.org/10.1097/00002820200202...
Therefore, two native Portuguese speaking dietitians who were also fluent in English (CMA and MAK) independently translated the SGA-7p and the MIS from English into Portuguese. The original SGA-7p and MIS models were available for review on the subject.44. Steiber AL, Kalantar-Zadeh K, Secker D, McCarthy M, Sehgal A, McCann L. Subjective Global Assessment in chronic kidney disease: a review. J Ren Nutr 2004;14:191-200. DOI: http://dx.doi.org/10.1016/S1051-2276(04)00139-6
http://dx.doi.org/10.1016/S1051-2276(04)...
Subsequently, the two versions translated into Portuguese of each instrument were analyzed by two other dietitians (RFL and JC) and they generated a Portuguese synthesis of each instrument. In the second phase, the summary version in Portuguese was retranslated into English by a native bilingual Brazilian who was an English teacher (RB). In the third phase, we tested the degree of similarity of the versions in which a native English speaking dietitian (AS) compared the original English version with the back-translated version of the Portuguese into English. For this, we used a specific form to assess aspects of semantic equivalence based on the referential (denotative) and general (connotative) meaning of the words. For referential meaning, we used visual analogue scales (VAS)1919. Streiner DL, Nornan GR. Health measurement scales. A practical guide to their development and use. 3rd ed. New York: Oxford University Press; 2003. as response option. In this scale, the equivalence between pairs of issues is continuously evaluated on a scale of 0 to 100. To assess the general meaning, we used a differential scale with four levels of discrete responses (unchanged, slightly altered, greatly altered and completely altered) of all the questions contained in the instruments (7 questions in the SGA-7p and 12 questions in the MIS).

After completion of this step, we conducted a pre-test with 10 elderly patients in HD in order to assess whether the translated instruments were easily understood by the examiners (dietitians) and the interviewees (patients). There was no difficulty in applying the tools in Portuguese by both parties.

To implement the instruments we used a three-session training. The first session consisted of a theoretical training on the questions of clinical assessment and physical examination. Later there was a practical training in which the dietitian examiners watched the dietitian responsible for training applying the instrument to five patients who were part of the sample from another research protocol, also conducted with elderly patients on HD. In the third session, the trainees applied the instruments under the supervision of a trainer dietitian. This training was conducted over a period of a week at the Interdisciplinary Nutritional Status Assessment Laboratory of (LIAN) of the Institute of Nutrition (INU) of the UERJ. The steps of semantic equivalence of the process are illustrated in Figure 2.

Figure 2
Translation; back translation; assessing the degree of similarity between the questionnaires; training and pre-testing. * Portuguese native language; ** English native language.

Measurement equivalence

Was assessed the measurement equivalence by measuring the reliability of the instruments translated into Portuguese. A measure of reliability is based on the internal consistency and inter-and intraexaminer reproducibility. In the present study, the interexaminer reproducibility was carried out by two dietitians who applied the SGA-7p and MIS instruments on the same day independently in 54 patients. We did not assess the intraexaminer reliability in this study.

Anthropometric measurements

Body weight (kg; electronic scale, Filizola®, up to 150 kg) and height (m; stadiometer attached to the electronic scale) were evaluated as described by Lohman et al.2020. Lohman TG. Advances in body composition assessment. Champaign: Human Kinetics; 1992. after the HD session. We calculated the BMI (current weight in kilograms divided by their height in meters squared) using the cutoff points proposed by the World Health Organization (WHO).2121. Obesity: preventing and managing the global epidemic. Report of a WHO consultation. World Health Organ Tech Rep Ser 2000;894:i-xii. PMID: 11234459

Laboratory analysis

We dosed: Serum urea, albumin (bromocresol green colorimetric method) and TIBC. For albumin, we used the normal range > 3.8 g/dL, as proposed by Fouque et al.2222. Fouque D, Kalantar-Zadeh K, Kopple J, Cano N, Chauveau P, Cuppari L, et al. A proposed nomenclature and diagnostic criteria for protein-energy wasting in acute and chronic kidney disease. Kidney Int 2008;73:391-8. DOI: http://dx.doi.org/10.1038/sj.ki.5002585
http://dx.doi.org/10.1038/sj.ki.5002585...
To calculate urea Kt/V we used the Daugirdas II2323. Daugirdas JT. Second generation logarithmic estimates of single-pool variable volume Kt/V: an analysis of error. J Am Soc Nephrol 1993;4:1205-13. equation from the midweek dialysis. Urea Kt/V values > 1.2 were considered indicative of good efficiency dialysis.2424. NKF-K/DOQI: NKF-K/DOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access. Am J Kidney Dis 2006;48:S1-321.

Statistical analysis

The data are presented as mean ± standard deviation or median and interquartile limits depending on the distribution of the variable. The variable distribution was tested by the Kurtosis test. For measurement equivalence, we employed the reliability testing that assessed SGA-7p and MIS internal consistency and interexaminer reliability. For internal consistency assessment we used the α Cronbach coefficient following Nunnally & Bernstein2525. Nunnally J, Bernstein I. Psychometric theory. 3rd ed. New York: McGraw-Hill; 1994. decision criteria, in which it considers a coefficient value of α ≥ 0.70 and the α Cronbach coefficient values were considered adequate as we eliminated each item from the instruments. The percentage value of increasing or decreasing the α coefficient vis-à-vis the removal of each item from the instrument had to be substantial (> 10%).2626. Reichenheim ME, Moraes CL. Qualidade dos instrumentos epidemiológicos. In: Almeida-Filho N, Barreto M. Epidemiologia e Saúde - Fundamentos, métodos e aplicações. Rio de Janeiro: Guanabara Koogan; 2011.p.150-64. The interexaminer reliability was evaluated by the intraclass correlation (ICC), following the decision criteria established by Shrout2727. Shrout PE. Measurement reliability and agreement in psychiatry. Stat Methods Med Res 1998;7:301-17.: ≤ 0.1: absent; > 0.1-0.4: weak; > 0.4-0.6: mild; > 0.6-0.8: moderate; > 0.8-1.0: strong. Statistical tests were performed using the SPSS version 18.0 for Windows (SPSS, Inc., Chicago, USA). Values of p < 0.05 were considered significant.

Results

101 patients in HD were evaluated, 75.2% (n = 76) were males aged 70.8 ± 7.0 years with HD duration of 2.3 (1.0, 5.3) years. Regarding comorbidities, hypertension (70.2%, n = 71) and diabetes mellitus (29%, n = 29) were the most frequent. The average BMI was 25.5 ± 4.9 kg/m2, indicating overweight, and 53.5% (n = 54) had a BMI < 25 kg/m2; 33.7% (n = 34) BMI ≥ 25 kg/m2 and < 30 kg/m2 and 12.8% (n = 13) BMI ≥ 30 kg/m2. Regarding laboratory parameters, there was a good dialysis adequacy (Kt/V = 1.5 ± 0.43) and reduced plasma albumin (3.7 ± 0.4 g/dL). Figure 3 describes the distribution of scores obtained by SGA-7p and MIS. There was a higher patient concentration in the range of 5 to 6 points for SGA-7p and from 6 to 8 and 11 points to MIS.

Figure 3
Nutritional status score distribution assessed by the 7-point Subjective Global Assessment (SGA-7p) and by the Malnutrition and Inflammation Score (MIS) (n = 101).

Semantic equivalence

The results from the Portuguese version (translated) of the instruments SGA-7p and MIS are depicted on Charts 1 and 2.

Chart 1
Final summarized portuguese version of the 7-point subjective global assessment (SGA-7p).
Chart 2
Final summarized version in Portuguese of the malnutrition and inflammation score (MIS)

The degree of similarity test between the original instrument in English and the one translated back into English showed a high degree of similarity of the referential meaning for both SGA-7p and the MIS, since the value obtained was close to the maximum score of 100 points (SGA-7p = 96.8 ± 7.8 points and MIS = 99.6 ± 1.4 points). As to the general meaning similarity, we noticed that of the seven questions contained in the instrument, six were found to be unchanged and only one was slightly altered. For the MIS, all the 12 questions of the instrument were considered unchanged.

Measurement equivalence

Reliability

As described on Table 1, we calculated the Cronbach α coefficient values for the SGA-7p and the MIS of the entire instrument, as well as the coefficient when excluding each item alone from the instrument. We also calculated the item-total correlation, which measures the degree of association of the item with the total scale. The Cronbach's α coefficient was obtained from the use of the SGA-7p and MIS in the 101 patients included in the study.

Table 1
Internal consistency of the 7-point subjective global assessment and malnutrition inflammation score (n = 101)

With respect to the SGA-7p, the Cronbach's α coefficient was satisfactory. The α coefficient estimates showed a slight improvement in the result upon excluding one item alone from the body weight history. The Cronbach's α percentage change upon excluding one of the items was within the expected values (Table 1).

For MIS, the total Cronbach α coefficient value was below the satisfactory value. The α coefficient estimates upon excluding one item from the scale showed better results with the removal of the items: change in body weight and gastrointestinal symptoms. The Cronbach's α percentage of change as we excluded one of the items came to be outside the expected range (> 10% or < 10%) for items: change in body weight, functional capacity, physical examination of body fat and muscle mass (Table 1).

With respect to interexaminer reproducibility (Table 2) for the SGA-7p, the ICC was indicative of moderate reproducibility and, for MIS the ICC was indicative of a strong reproducibility. With respect to the reproducibility values assessed for each item of the instruments, we noticed that on the SGA-7p, items with interexaminer moderate to strong reproducibility were body weight history, gastrointestinal symptoms, functional capacity, comorbidity and physical exam of body fat. For MIS they were: body weight change, gastrointestinal symptoms, comorbidities and functional capacity, which showed moderate to strong interexaminer reproducibility. We did not assess the interexaminer reproducibility of the MIS objective items (BMI, albumin and TIBIC), since these are not subject to interexaminer variability.

Table 2
Seven-point subjective global assessment and malnutrition inflammation score interexaminer reproducibility analysis.

Discussion

This study refers to the cultural adaptation from English into Portuguese of two methods used for assessing nutritional status, SGA-7p and MIS. These methods have been widely used in CKD patients on HD, both in clinical practice and in clinical and epidemiological trials.99. Steiber A, Leon JB, Secker D, McCarthy M, McCann L, Serra M, et al. Multicenter study of the validity and reliability of subjective global assessment in the hemodialysis population. J Ren Nutr 2007;17:336-42. DOI: http://dx.doi.org/10.1053/j.jrn.2007.05.004
http://dx.doi.org/10.1053/j.jrn.2007.05....

10. de Mutsert R, Grootendorst DC, Boeschoten EW, Brandts H, van Manen JG, Krediet RT, et al. Subjective global assessment of nutritional status is strongly associated with mortality in chronic dialysis patients. Am J Clin Nutr 2009;89:787-93. PMID: 19144733 DOI: http://dx.doi.org/10.3945/ajcn.2008.26970
http://dx.doi.org/10.3945/ajcn.2008.2697...

11. Vero LM, Byham-Gray L, Parrott JS, Steiber AL. Use of the subjective global assessment to predict health-related quality of life in chronic kidney disease stage 5 patients on maintenance hemodialysis. J Ren Nutr 2013;23:141-7. DOI: http://dx.doi.org/10.1053/j.jrn.2012.03.003
http://dx.doi.org/10.1053/j.jrn.2012.03....
-1212. Tsai HJ, Tsai AC, Hung SY, Chang MY. Comparing the predictive ability of population-specific Mini-Nutritional Assessment with Subjective Global Assessment for Taiwanese patients with hemodialysis: a cross-sectional study. Int J Nurs Stud 2011;48:326-32. PMID: 20817182 DOI: http://dx.doi.org/10.1016/j.ijnurstu.2010.07.015
http://dx.doi.org/10.1016/j.ijnurstu.201...
,2828. Yamada K, Furuya R, Takita T, Maruyama Y, Yamaguchi Y, Ohkawa S, et al. Simplified nutritional screening tools for patients on maintenance hemodialysis. Am J Clin Nutr 2008;87:106-13. PMID: 18175743

29. Jones CH, Wolfenden RC, Wells LM. Is subjective global assessment a reliable measure of nutritional status in hemodialysis? J Ren Nutr 2004;14:26-30.
-3030. Rambod M, Bross R, Zitterkoph J, Benner D, Pithia J, Colman S, et al. Association of Malnutrition-Inflammation Score with quality of life and mortality in hemodialysis patients: a 5-year prospective cohort study. Am J Kidney Dis 2009;53:298-309. DOI: http://dx.doi.org/10.1053/j.ajkd.2008.09.018
http://dx.doi.org/10.1053/j.ajkd.2008.09...
In Brazil, these instruments have been used in a smaller scale, possibly due to the lack of validation of these translations into Portuguese. Thus, the relevance of this study in presenting results that contribute to clinical practice and research regarding the evaluation of nutritional status in patients with CKD.

The Portuguese versions of the SGA-7p and the MIS presented in this paper were obtained by the back-translation method, which ensures the semantic quality of the translated instrument.1616. Beaton DE, Bombardier C, Guillemin F, Ferraz MB. Guidelines for the process of cross-cultural adaptation of self-report measures. Spine (Phila Pa 1976) 2000;25:3186-91. DOI: http://dx.doi.org/10.1097/00007632-200012150-00014
http://dx.doi.org/10.1097/00007632-20001...

17. Herdman M, Fox-Rushby J, Badia X. A model of equivalence in the cultural adaptation of HRQoL instruments: the universalist approach. Qual Life Res 1998;7:323-35.
-1818. Hilton A, Skrutkowski M. Translating instruments into other languages: development and testing processes. Cancer Nurs 2002;25:1-7. DOI: http://dx.doi.org/10.1097/00002820200202000-00001
http://dx.doi.org/10.1097/00002820200202...
As shown, both SGA-7p and MIS were semantically equivalent, having presented a high degree of similarity vis-à-vis the total and referential meanings between the original version and the one back-translated into English. Other studies in the general population which underwent back-translation were considered well translated with degree of similarity rates matching those found in our study.3131.Moraes CL, Reichenheim ME. Cross-cultural measurement equivalence of the Revised Conflict Tactics Scales (CTS2) Portuguese version used to identify violence within couples. Cad Saude Publica 2002;18:783-96. DOI: http://dx.doi.org/10.1590/S0102-311X2002000300027
http://dx.doi.org/10.1590/S0102-311X2002...
,3232.Duarte PS, Miyazaki MC, Ciconelli RM, Sesso R. Translation and cultural adaptation of the quality of life assessment instrument for chronic renal patients (KDQOL-SF). Rev Assoc Med Bras 2003;49:375-81. PMID: 14963588 DOI: http://dx.doi.org/10.1590/S0104-42302003000400027
http://dx.doi.org/10.1590/S0104-42302003...
Thus, the translated instruments presented hereby are suitable for use in Brazil.

In our study, we noticed that the Portuguese version of the SGA-7p and MIS showed different internal consistencies. The SGA-7p obtained a Cronbach α coefficient greater than that of the MIS, indicative of adequate internal consistency (α> 0.70). Moreover, on the SGA-7p the assessment of the association between the outcomes of each item composing the instrument with the end result denoted homogeneity of items. This finding is confirmed by the reduced value of the percentage of change in total α by excluding some item (< 10%). In other words, there was no item with greater importance than others to the overall result of SGA-7p. As for the MIS, the Cronbach α did not indicate satisfactory internal consistency (α < 0.70). Indeed, the individual removal of some items from the instrument distanced significantly the total α (> 10%). This difference of internal consistency between the SGA-7p and the MIS may be due to the way with which the final score of each instrument is given. In the SGA-7p, the final score results from the value that prevails on all items, so that there is greater examiner involvement in the final score. In the MIS, the final score comes from the sum of scores from each item, thus reducing examiner participation. Furthermore, in the SGA-7p all items including the final score may be worth from 1 to 7 points, whereas in the MIS, each item can vary from 0 to 3 and the final results vary between 0 and 30. This wider score range may also have contributed to the worse MIS internal consistency. However, we cannot say whether this finding is due to the translation of the instruments or a characteristic of those instruments, since the original SGA-7p and MIS studies do not describe internal consistency data.99. Steiber A, Leon JB, Secker D, McCarthy M, McCann L, Serra M, et al. Multicenter study of the validity and reliability of subjective global assessment in the hemodialysis population. J Ren Nutr 2007;17:336-42. DOI: http://dx.doi.org/10.1053/j.jrn.2007.05.004
http://dx.doi.org/10.1053/j.jrn.2007.05....

10. de Mutsert R, Grootendorst DC, Boeschoten EW, Brandts H, van Manen JG, Krediet RT, et al. Subjective global assessment of nutritional status is strongly associated with mortality in chronic dialysis patients. Am J Clin Nutr 2009;89:787-93. PMID: 19144733 DOI: http://dx.doi.org/10.3945/ajcn.2008.26970
http://dx.doi.org/10.3945/ajcn.2008.2697...

11. Vero LM, Byham-Gray L, Parrott JS, Steiber AL. Use of the subjective global assessment to predict health-related quality of life in chronic kidney disease stage 5 patients on maintenance hemodialysis. J Ren Nutr 2013;23:141-7. DOI: http://dx.doi.org/10.1053/j.jrn.2012.03.003
http://dx.doi.org/10.1053/j.jrn.2012.03....

12. Tsai HJ, Tsai AC, Hung SY, Chang MY. Comparing the predictive ability of population-specific Mini-Nutritional Assessment with Subjective Global Assessment for Taiwanese patients with hemodialysis: a cross-sectional study. Int J Nurs Stud 2011;48:326-32. PMID: 20817182 DOI: http://dx.doi.org/10.1016/j.ijnurstu.2010.07.015
http://dx.doi.org/10.1016/j.ijnurstu.201...

13. de Mutsert R, Grootendorst DC, Indemans F, Boeschoten EW, Krediet RT, Dekker FW; Netherlands Cooperative Study on the Adequacy of Dialysis-II Study Group. Association between serum albumin and mortality in dialysis patients is partly explained by inflammation, and not by malnutrition. J Ren Nutr 2009;19:127-35. DOI: http://dx.doi.org/10.1053/j.jrn.2008.08.003
http://dx.doi.org/10.1053/j.jrn.2008.08....
-1414. Kalantar-Zadeh K, Kopple JD, Block G, Humphreys MH. A malnutrition-inflammation score is correlated with morbidity and mortality in maintenance hemodialysis patients. Am J Kidney Dis 2001;38:1251-63. PMID: 11728958 DOI: http://dx.doi.org/10.1053/ajkd.2001.29222
http://dx.doi.org/10.1053/ajkd.2001.2922...

Regarding the interexaminer reproducibility, we noticed a moderate reproducibility for the SGA-7p. This result was similar to that found in other studies involving patients with CKD.99. Steiber A, Leon JB, Secker D, McCarthy M, McCann L, Serra M, et al. Multicenter study of the validity and reliability of subjective global assessment in the hemodialysis population. J Ren Nutr 2007;17:336-42. DOI: http://dx.doi.org/10.1053/j.jrn.2007.05.004
http://dx.doi.org/10.1053/j.jrn.2007.05....
,3333.Visser M, van den Heuvel E, Deurenberg P. Prediction equations for the estimation of body composition in the elderly using anthropometric data. Br J Nutr 1994;71:823-33. DOI: http://dx.doi.org/10.1079/BJN19940189
http://dx.doi.org/10.1079/BJN19940189...
However, a study carried out including cancer patients in our country, assessed SGA's intraexaminer reproducibility generated by the patient. The auconsistency between the SGA-7p and the MIS maythors reported a high reproducibility (kappa test 0.78, p < 0.001).3434. Duarte Bonini Campos JA, Dias do Prado C. Cross-cultural adaptation of the Portuguese version of the Patient-Generated Subjective Global Assessment. Nutr Hosp 2012;27:583-9. For MIS, interexaminer reproducibility was strong, a result contrary to that of another study including patients on HD, which found moderate interexaminer reproducibility (kappa 0.68, CI 0.52-0.72).3535.Beberashvili I, Azar A, Sinuani I, Kadoshi H, Shapiro G, Feldman L, et al. Comparison analysis of nutritional scores for serial monitoring of nutritional status in hemodialysis patients. Clin J Am Soc Nephrol 2013;8:443-51. DOI: http://dx.doi.org/10.2215/CJN.04980512
http://dx.doi.org/10.2215/CJN.04980512...
Since the SGA-7p operates in a more subjective decision mode than the MIS, the best reproducibility found in the MIS could arise from the same scoring format.

A limitation of our study is the fact that it involved only elderly patients (> 60 years), not representing the general population in HD. On the other hand, the semantic equivalence of the AGS-7p and MIS translation process is independent of the age range studied. The internal consistency results, which were evaluated in elderly on HD, deserves to be further investigated both in the group of elderly patients on PD, as well as in adults in both dialysis modalities. However, it is expected that the results obtained in elderly recur in adults.

Conclusion

In conclusion, the SGA-7p and MIS translated into Portuguese can be used in elderly patients on HD. We still need other studies that test the applicability of these versions translated into Portuguese in a group of patients with different ages and on PD.

  • Carlos Chagas Filho Foundation for Research Support of the State of Rio de Janeiro (FAPERJ) (E-26/111.653/2010 and E-26/103.209/2011).

Acknowledgment

The authors thank Juliana Cordeiro Dias Rodrigues and Fernando Lamarca for having actively contributed in the data collection process for this study; and Ana Lúcia Pereira, for her support in contacting patients in one of the dialysis clinic where the study was developed.

Referências

  • 1
    Clinical practice guidelines for nutrition in chronic renal failure. K/DOQI, National Kidney Foundation. Am J Kidney Dis 2000;35:S1-140.
  • 2
    Fouque D, Vennegoor M, ter Wee P, Wanner C, Basci A, Canaud B, et al. EBPG guideline on nutrition. Nephrol Dial Transplant 2007;22:ii45-87. DOI: http://dx.doi.org/10.1093/ndt/gfm020
    » http://dx.doi.org/10.1093/ndt/gfm020
  • 3
    Martins C, Cuppari L, Avesani C, Gusmão MG. Terapia Nutricional para Pacientes em Hemodiálise Crônica. In: Projeto Diretrizes da AMB/SBNPE/Nutrologia. São Paulo: Associação Médica Brasileira; 2011.p.1-10.
  • 4
    Steiber AL, Kalantar-Zadeh K, Secker D, McCarthy M, Sehgal A, McCann L. Subjective Global Assessment in chronic kidney disease: a review. J Ren Nutr 2004;14:191-200. DOI: http://dx.doi.org/10.1016/S1051-2276(04)00139-6
    » http://dx.doi.org/10.1016/S1051-2276(04)00139-6
  • 5
    Detsky AS, Baker JP, Mendelson RA, Wolman SL, Wesson DE, Jeejeebhoy KN. Evaluating the accuracy of nutritional assessment techniques applied to hospitalized patients: methodology and comparisons. JPEN J Parenter Enteral Nutr 1984;8:153-9. DOI: http://dx.doi.org/10.1177/0148607184008002153
    » http://dx.doi.org/10.1177/0148607184008002153
  • 6
    Barbosa-Silva MCG, Barros AJD. Avaliação nutricional subjetiva: Parte 2 - Revisão de suas adaptações e utilizações nas diversas especialidades clínicas. Arq Gastroenterol 2002;39:248-52.
  • 7
    Enia G, Sicuso C, Alati G, Zoccali C. Subjective global assessment of nutrition in dialysis patients. Nephrol Dial Transplant 1993;8:1094-8.
  • 8
    Adequacy of dialysis and nutrition in continuous peritoneal dialysis: association with clinical outcomes. Canada-USA (CANUSA) Peritoneal Dialysis Study Group. J Am Soc Nephrol 1996;7:198-207.
  • 9
    Steiber A, Leon JB, Secker D, McCarthy M, McCann L, Serra M, et al. Multicenter study of the validity and reliability of subjective global assessment in the hemodialysis population. J Ren Nutr 2007;17:336-42. DOI: http://dx.doi.org/10.1053/j.jrn.2007.05.004
    » http://dx.doi.org/10.1053/j.jrn.2007.05.004
  • 10
    de Mutsert R, Grootendorst DC, Boeschoten EW, Brandts H, van Manen JG, Krediet RT, et al. Subjective global assessment of nutritional status is strongly associated with mortality in chronic dialysis patients. Am J Clin Nutr 2009;89:787-93. PMID: 19144733 DOI: http://dx.doi.org/10.3945/ajcn.2008.26970
    » http://dx.doi.org/10.3945/ajcn.2008.26970
  • 11
    Vero LM, Byham-Gray L, Parrott JS, Steiber AL. Use of the subjective global assessment to predict health-related quality of life in chronic kidney disease stage 5 patients on maintenance hemodialysis. J Ren Nutr 2013;23:141-7. DOI: http://dx.doi.org/10.1053/j.jrn.2012.03.003
    » http://dx.doi.org/10.1053/j.jrn.2012.03.003
  • 12
    Tsai HJ, Tsai AC, Hung SY, Chang MY. Comparing the predictive ability of population-specific Mini-Nutritional Assessment with Subjective Global Assessment for Taiwanese patients with hemodialysis: a cross-sectional study. Int J Nurs Stud 2011;48:326-32. PMID: 20817182 DOI: http://dx.doi.org/10.1016/j.ijnurstu.2010.07.015
    » http://dx.doi.org/10.1016/j.ijnurstu.2010.07.015
  • 13
    de Mutsert R, Grootendorst DC, Indemans F, Boeschoten EW, Krediet RT, Dekker FW; Netherlands Cooperative Study on the Adequacy of Dialysis-II Study Group. Association between serum albumin and mortality in dialysis patients is partly explained by inflammation, and not by malnutrition. J Ren Nutr 2009;19:127-35. DOI: http://dx.doi.org/10.1053/j.jrn.2008.08.003
    » http://dx.doi.org/10.1053/j.jrn.2008.08.003
  • 14
    Kalantar-Zadeh K, Kopple JD, Block G, Humphreys MH. A malnutrition-inflammation score is correlated with morbidity and mortality in maintenance hemodialysis patients. Am J Kidney Dis 2001;38:1251-63. PMID: 11728958 DOI: http://dx.doi.org/10.1053/ajkd.2001.29222
    » http://dx.doi.org/10.1053/ajkd.2001.29222
  • 15
    Reichenheim ME, Moraes CL. Operationalizing the cross-cultural adaptation of epidemiological measurement instruments. Rev Saude Publica 2007;41:665-73.
  • 16
    Beaton DE, Bombardier C, Guillemin F, Ferraz MB. Guidelines for the process of cross-cultural adaptation of self-report measures. Spine (Phila Pa 1976) 2000;25:3186-91. DOI: http://dx.doi.org/10.1097/00007632-200012150-00014
    » http://dx.doi.org/10.1097/00007632-200012150-00014
  • 17
    Herdman M, Fox-Rushby J, Badia X. A model of equivalence in the cultural adaptation of HRQoL instruments: the universalist approach. Qual Life Res 1998;7:323-35.
  • 18
    Hilton A, Skrutkowski M. Translating instruments into other languages: development and testing processes. Cancer Nurs 2002;25:1-7. DOI: http://dx.doi.org/10.1097/00002820200202000-00001
    » http://dx.doi.org/10.1097/00002820200202000-00001
  • 19
    Streiner DL, Nornan GR. Health measurement scales. A practical guide to their development and use. 3rd ed. New York: Oxford University Press; 2003.
  • 20
    Lohman TG. Advances in body composition assessment. Champaign: Human Kinetics; 1992.
  • 21
    Obesity: preventing and managing the global epidemic. Report of a WHO consultation. World Health Organ Tech Rep Ser 2000;894:i-xii. PMID: 11234459
  • 22
    Fouque D, Kalantar-Zadeh K, Kopple J, Cano N, Chauveau P, Cuppari L, et al. A proposed nomenclature and diagnostic criteria for protein-energy wasting in acute and chronic kidney disease. Kidney Int 2008;73:391-8. DOI: http://dx.doi.org/10.1038/sj.ki.5002585
    » http://dx.doi.org/10.1038/sj.ki.5002585
  • 23
    Daugirdas JT. Second generation logarithmic estimates of single-pool variable volume Kt/V: an analysis of error. J Am Soc Nephrol 1993;4:1205-13.
  • 24
    NKF-K/DOQI: NKF-K/DOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access. Am J Kidney Dis 2006;48:S1-321.
  • 25
    Nunnally J, Bernstein I. Psychometric theory. 3rd ed. New York: McGraw-Hill; 1994.
  • 26
    Reichenheim ME, Moraes CL. Qualidade dos instrumentos epidemiológicos. In: Almeida-Filho N, Barreto M. Epidemiologia e Saúde - Fundamentos, métodos e aplicações. Rio de Janeiro: Guanabara Koogan; 2011.p.150-64.
  • 27
    Shrout PE. Measurement reliability and agreement in psychiatry. Stat Methods Med Res 1998;7:301-17.
  • 28
    Yamada K, Furuya R, Takita T, Maruyama Y, Yamaguchi Y, Ohkawa S, et al. Simplified nutritional screening tools for patients on maintenance hemodialysis. Am J Clin Nutr 2008;87:106-13. PMID: 18175743
  • 29
    Jones CH, Wolfenden RC, Wells LM. Is subjective global assessment a reliable measure of nutritional status in hemodialysis? J Ren Nutr 2004;14:26-30.
  • 30
    Rambod M, Bross R, Zitterkoph J, Benner D, Pithia J, Colman S, et al. Association of Malnutrition-Inflammation Score with quality of life and mortality in hemodialysis patients: a 5-year prospective cohort study. Am J Kidney Dis 2009;53:298-309. DOI: http://dx.doi.org/10.1053/j.ajkd.2008.09.018
    » http://dx.doi.org/10.1053/j.ajkd.2008.09.018
  • 31
    Moraes CL, Reichenheim ME. Cross-cultural measurement equivalence of the Revised Conflict Tactics Scales (CTS2) Portuguese version used to identify violence within couples. Cad Saude Publica 2002;18:783-96. DOI: http://dx.doi.org/10.1590/S0102-311X2002000300027
    » http://dx.doi.org/10.1590/S0102-311X2002000300027
  • 32
    Duarte PS, Miyazaki MC, Ciconelli RM, Sesso R. Translation and cultural adaptation of the quality of life assessment instrument for chronic renal patients (KDQOL-SF). Rev Assoc Med Bras 2003;49:375-81. PMID: 14963588 DOI: http://dx.doi.org/10.1590/S0104-42302003000400027
    » http://dx.doi.org/10.1590/S0104-42302003000400027
  • 33
    Visser M, van den Heuvel E, Deurenberg P. Prediction equations for the estimation of body composition in the elderly using anthropometric data. Br J Nutr 1994;71:823-33. DOI: http://dx.doi.org/10.1079/BJN19940189
    » http://dx.doi.org/10.1079/BJN19940189
  • 34
    Duarte Bonini Campos JA, Dias do Prado C. Cross-cultural adaptation of the Portuguese version of the Patient-Generated Subjective Global Assessment. Nutr Hosp 2012;27:583-9.
  • 35
    Beberashvili I, Azar A, Sinuani I, Kadoshi H, Shapiro G, Feldman L, et al. Comparison analysis of nutritional scores for serial monitoring of nutritional status in hemodialysis patients. Clin J Am Soc Nephrol 2013;8:443-51. DOI: http://dx.doi.org/10.2215/CJN.04980512
    » http://dx.doi.org/10.2215/CJN.04980512

Publication Dates

  • Publication in this collection
    Apr-Jun 2014

History

  • Received
    30 Jan 2014
  • Accepted
    26 Feb 2014
Sociedade Brasileira de Nefrologia Rua Machado Bittencourt, 205 - 5ºandar - conj. 53 - Vila Clementino - CEP:04044-000 - São Paulo SP, Telefones: (11) 5579-1242/5579-6937, Fax (11) 5573-6000 - São Paulo - SP - Brazil
E-mail: bjnephrology@gmail.com