Acessibilidade / Reportar erro

Post-irradiation vickers microhardness development of novel resin composites

Abstract

The aim of this study was to evaluate the effect of post-irradiation dry aging at different periods of time on Vickers microhardness of some dental composites based on various resin matrices. Sixty four disc-shaped specimens of the resin composites were prepared in a split Teflon mold (8 × 2 mm) and irradiated by Optilux 501 light cure (500 mW.cm-2 for 40 seconds) on their top side. The specimens were aged-dry in dark at 23 and 37 °C for the following storage periods; immediate, 1/2 an hour, 1, 6, 12, 24, 48 and 168 hours. The microhardness values were recorded using a Vickers Hardness Tester at 300 g load for 15 seconds. Results showed that Filtek® P90 and Definite expressed the highest hardness value followed by Tetric Evoceram and then Premise Enamel. At each aging period, all materials demonstrated significant differences between hardness values of top and base surfaces as well as both temperatures examined (P < 0.05). In conclusion, surface hardness developed gradually in most of the materials reaching optimum after 168 hours post-irradiation aging. Dental composites based on silorane and ormocer resin matrices achieved higher Vickers microhardness than those based on dimethacrylates resin.

post-irradiation aging; vickers microhardness; nanohybrid composites; silorane; ormocer


REGULAR ARTICLES

Post-irradiation vickers microhardness development of novel resin composites

Hanadi Yousif Marghalani* * e-mail: hymarghalani@hotmail.com, hanadi.marghalani@gmail.com

Conservative Dental Science Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, KSA 85 Prince Fawaz dist. P.O. Box 35030, Jeddah 21488, Saudi Arabia

ABSTRACT

The aim of this study was to evaluate the effect of post-irradiation dry aging at different periods of time on Vickers microhardness of some dental composites based on various resin matrices. Sixty four disc-shaped specimens of the resin composites were prepared in a split Teflon mold (8 × 2 mm) and irradiated by Optilux 501 light cure (500 mW.cm–2 for 40 seconds) on their top side. The specimens were aged-dry in dark at 23 and 37 °C for the following storage periods; immediate, 1/2 an hour, 1, 6, 12, 24, 48 and 168 hours. The microhardness values were recorded using a Vickers Hardness Tester at 300 g load for 15 seconds. Results showed that Filtek® P90 and Definite expressed the highest hardness value followed by Tetric Evoceram and then Premise Enamel. At each aging period, all materials demonstrated significant differences between hardness values of top and base surfaces as well as both temperatures examined (P < 0.05). In conclusion, surface hardness developed gradually in most of the materials reaching optimum after 168 hours post-irradiation aging. Dental composites based on silorane and ormocer resin matrices achieved higher Vickers microhardness than those based on dimethacrylates resin.

Keywords: post-irradiation aging, vickers microhardness, nanohybrid composites, silorane, ormocer

1. Introduction

Resin composite restorative is rapidly becoming the dental material of choice for conservative and direct applications in esthetic dentistry than the conventional materials. Nowadays, the development of the esthetic dentistry resulted in increasing interest of using resin composites in high stress dental bearing areas. The most important factor that limits their use in these areas is that they are not hard enough to withstand mastication strength. The improvements in the currently available composite materials include the increase of filler content, variations in size, type and morphology of the particles, in addition to changes in the organic matrix1. These changes have conferred better mechanical properties to these materials, thus, allowing them to be used in areas subjected to great masticatory efforts2.

The advent of nanotechnology in field of dentistry is based on production of nanocomposites by improving the filler technology of submicron particle size, modification of organic matrix and silane coupling agent3. The nanotechnology is aimed to improve the physical and mechanical properties of the composite restoratives. Several studies have been focused on the filler content, particle size, and the development of new particles3,4. Many efforts have been undertaken to maximize the clinical performance nanofilled composites5. Ceramic based composites enable to yield good polishability, low wear and high gloss, while composites containing ytterbium trifluoride offer better radiopacity5. Moreover, inclusion of smaller filler particles as nano-size in the final formulation of the composites results in reduction of composite's shrinkage and improving their total mechanical properties4.

Recently, the main focus in the further development of modern restorative composites is targeted on the modification of polymer matrix or fillers aiming at reduction of polymerization shrinkage and stress, increasing the degree of monomers conversion and improving their overall properties. Furthermore, nanotechnology involves several researches on different resin matrices that are mainly based on the development of new monomers. Some of novel resin polymers such as silorane, thiol-ene oligomer, hyperbranched (dendritic) monomers, polyhedral oligomeric silsesquioxanes methacrylate (POSS-MA) and pure ormocer have been developed6-8.

Initial efforts were based on developing monomers or comonomers as epoxies that potentially expand upon polymerization9. However, the newly developed silorane-based composite demonstrated a ring-opening expansion polymerization mechanism which reduces the internal shrinkage stress6. In addition to low polymerization shrinkage that characterizes this composite, it revealed low mutagenic potential, water sorption, solubility and cusp deflection10,11. Apart from the composite based on expanding ring-opening resin during the polymerization process, ormocer, however, is based on inorganic-organic hybrid polymers that are nearly as hard as glass aiming to reduce shrinkage. Ormocer is formed by polycondensation of silicone alkoxide precursors yielding a 3-dimensional Silicone–Oxide-Silicone network of inorganic-organic copolymer which is polymerized by their methacrylate functionality8.

Adequate surface hardness of the resin composites is important to obtain optimum clinical performance of the restoratives in stress dental bearing areas. Hardness is a surface property defined as the resistance of a material to permanent indentation or penetration. The composite's surface hardness and the effect of post-irradiation aging have been studied extensively by many investigators12-14. It has been reported that the hardness of inorganic fillers has a direct effect on the material's hardness15. In general, the increase of particle size increases the strength as well as the surface hardness of composite. Moreover, after polymerization, the solidified polymer matrix that is formed plays a role in hardness development. It has been shown previously that monomers have not participated in polymerization reactions lead to a decrease in hardness16. Therefore, the purpose of this study was to determine the effect of post-irradiation dry aging on Vickers microhardness of some novel composites based on different resin matrices over periods of time after polymerization; at two common temperatures.

2. Materials and Methods

The four resin composites investigated in the present study are tabulated in Table 1. They are two nanohybrid dimethacrylate-based composites: (Tetric evoceram and Premise enamel), one cationic composite (Filtek P90), and one ormocer (Definite).

2.1. Specimen preparation and group organization

Sixty four disc-shaped specimens (8 mm diameter × 2 mm thick) of the resin composites were fabricated in a split Teflon mold at room temperature. The resin composite material was gently packed inside the mold which was rested on a glass plate (76 × 26 × 1 mm Surgipath glass). The upper and lower surfaces of the unpolymerized specimen were covered with thin Mylar strips (KerrHawe Neos Dent, Bioggio, Switzerland). Then another glass plate was compressed carefully on top of the specimen to remove the excess of the material giving a flat surface.

The glass slide was then removed, leaving the Mylar strip, after which the light-curing process was initiated. The resin composites were irradiated by a conventional halogen light curing unit (Optilux® 501, SDS, Kerr, Danbury, CT, USA) at 500 mW.cm–2 for 40 seconds. The polymerization of the disc was carried out on the top side at 0.1 mm against the Mylar strip surface. The power density of the curing light unit was periodically monitored with an external handheld radiometer (Demetron/ Kerr, Danburry, CT, USA).

The hardened specimens were then removed from the mold and lightly finished manually from both sides after the preparation. This finishing procedure was carried out with 1000 grit silicone carbide (SiC) abrasive paper under running-coolant water followed by polishing with 2000 grit SiC paper as well as 5 and 1 µm aluminum oxide slurry pastes for 5 seconds each step. This will allow removal of a weak resin-rich layer giving a smooth-flat testing surface. Afterwards, the examined surface was assessed for any major defects or scratches by stereo-microscope (Meiji® Techno America, San Jose, CA., USA). The specimens were then randomly divided into two groups; the first group was aged-dry in dark bottles at 23 ± 0.5 °C and the second one was aged similarly but inside incubator at 37 ± 0.5 °C. Each of the previous groups was further divided into eight sub-groups according to the following storage (aging) periods; immediate for 5 minutes, 1/2 an hour, 1, 6, 12, 24, 48 and 168 hours (1 week).

2.2. Vickers surface microhardness test

The microhardness values of the upper and lower surfaces were measured with a Vickers micro-Hardness Tester (HMV-2 Shimadzu, Shimadzu® corp., Kyoto, Japan) using a diamond pyramid micro-indenter with a 136° angle between the opposing faces. The test was conducted at room temperature (23 ± 1°C) under a load of 300 g for 15 seconds. The Vickers hardness number (VHN) was obtained with the following Equation 1:

VHN = 1854.4 P/d2 (1)

where P is the applied load in grams (or N = Newton) and d is the average length of the diagonal of indentation measured in mm. Five equally spaced square indentations were randomly made on top as well as base side of each specimen (n = 5 per each side). They were not placed closer than 1mm to either adjacent indentations or to the margin of the specimens. They were measured after dry aging at the above mentioned time-intervals and the average was determined. The readings were recorded immediately after removal of the indenter to minimize the effects of elastic recovery of polymers on the results.

Data were analyzed by SPSS software (Version 11.5, SPSS® Inc., Chicago, Illinois, USA) utilizing two-factor analysis of variance (ANOVA) to determine significant differences between the two independent variables (materials and post-irradiation times) at 0.05 level of significance. If there is a significant interaction between them, one-factor ANOVA and post-hoc multiple comparison Tukey's test were used to detect the differences between the microhardness values within each variable. Independent t-test was used to evaluate the differences in microhardness between the top and base surfaces as well as the two temperatures in each aging group.

3. Results

The Vickers micohardness (VHN) mean and standard deviation values as a function of the post-irradiation aging times for top and base surfaces of the composite specimens at two different temperatures are summarized in Table 2 and displayed graphically in Figure 1 and 2. Two-factor ANOVA revealed high significant differences of the hardness values among the four composites examined and the eight post-irradiation aging periods (p = 0.000). Furthermore, it indicated a high significant interaction between these two independent variables (p = 0.000). Therefore, the VHN of the material was dependent on post-irradiation aging time, thus, one-factor ANOVA was used to analyze the significant differences.



The one-factor ANOVA demonstrated high significant differences between the materials for the micohardness at each aging time examined (p < 0.05) with some exceptions. For example, no significant differences were detected in microhardness on the top surface of Definite and Tetric Evoceram after 6 and 12 hours at 37 °C, and after 168 hours at 23 °C. Furthermore, independent t-test showed high significant differences between micohardness values of top and base surfaces for all the composite materials at 23 and 37 °C (p < 0.05). Moreover, the same test showed high significant differences between micohardness values at the two temperatures tested with some exceptions. At 23 and 37 °C, post-irradiation hardness values of all materials recorded after 24, 48 and 168 hours were higher and statistically different (p < 0.05) from those measured 5 minutes after light curing.

Most of the materials investigated showed the lowest microhardness values (ranged between 27.1 for Premise Enamel at base surface and 53.6 for Filtek® P90 at top surface) when measured immediately after preparation. On the contrary, the highest microhardness values (ranged between 57.1 for Premise Enamel at base surface and 89.4 for Filtek® P90 at top surface) were recorded after 168 hours post-irradiation aging. A gradual development of surface hardness value was observed with Filtek® P90 resin composite reaching optimum after 168 hours post-irradiation aging. The highest hardness peak value was started after 24 hours post-irradiation storage and then it was either maintained constant as in some resin composites (Definite and Premise Enamel at 23 °C) or it was raised more after one week post-irradiation aging as in Filtek® P90 and Tetric Evoceram.

At 37 °C, Filtek® P90 and Definite expressed the highest hardness value followed by Tetric Evoceram and then Premise Enamel which showed the lowest surface microhardness. It was noted that at a relatively high body-temperature (37 °C), the Vickers microhardness values for both top and base surfaces of the specimens were higher than those measured at 23 °C. All samples demonstrated significantly harder top surfaces than base ones (p < 0.05). The hardest top surface was observed in Filtek® P90 followed by Definite when they were aged for 168 hours at 37 °C (89.4 and 81.5, respectively). However, the base surface of Premise Enamel specimens expressed the lowest hardness value (27.1) when they were measured immediately after the preparation at 23 °C.

4. Discussion

Vickers microhardness test was selected for this study because it is relatively a simple technique, very popular and reliable for obtaining the results. Additionally, it is considered by several authors as an indicator for the degree of polymerization of resin materials and used commonly as indirect method to evaluate degree of cure13,14. Surface microhardness is considered as an indicative factor of the mechanical strength of a resin and correlates well to the material's rigidity17. In the current study, all test samples were submitted to the same parameters of light-curing method and initial finishing. Slight finishing and polishing were performed for the specimen's surface after polymerization in order to remove the softer resin-rich layer of material and exposing the hardest one. Removal of this weak superficial layer is essential to produce a relatively stable surface with increasing predictability of developing high surface hardness. In this study, 2 mm specimen's thickness of resin composites may be sufficient to allow favorable depth of cure for light penetration and performing the hardness test. Moreover, dry aging of the specimens were selected because it has been noted that a rapid polymerization and increase of hardness were observed in dry condition and elevated temperature14. This is inconsistent with a previous work18. Hardness measurements were performed at top-irradiated and base-nonirradiated surfaces of the specimens to ensure proper cure of the resin.

Composite-related factors affecting strongly surface hardness of the material include filler particle size, type, morphology, distribution, volume fraction and diluent's concentration. A positive correlation has been established between the hardness and inorganic filler content of resin composites1,2. Composites with harder filler particles and higher filler load exhibit higher surface hardness2. It was found that composites with round filler particles had the highest filler loading, resulting in the highest hardness, while those with irregular-shaped filler particles had intermediate filler loading and hardness19. Additionally, resin composition, type and degree of polymerization significantly affect the hardness of the restorative materials20,21. The polymerizing system and degree of conversion of resin composites may influence the hardness. The correlation between surface hardness and degree of conversion of resin materials has been demonstrated in previous studies21,22. However, the light-related factors that may affect hardness include light intensity, the distance between light-curing guide to the material and exposure time23.

The data of this study revealed that silorane-based (Filtek® P90) and ormocer-based (Definite) composites demonstrated higher VHN than Premise Enamel. Although the later composite is nanohybrid and expressed high filler content in its composition. Premise Enamel showed the lowest surface hardness among the materials examined, which can be attributed to the presence of small filler particles that causes a light scattering, thus, decreasing the effectiveness of the curing light3,5. This is in the contrary with a previous study found that high filler content increases the surface hardness19.

The higher surface hardness of Filtek® P90 and Definite after the post-irradiation aging may be related to their composition. Filtek P90 promoted the highest VHN values which can be attributed to the cationic polymerization reaction. It is characterized by continuous ring-opening expansion initiated at the time of curing and promoted further crosslinking and hardening of the entire matrix24,25. This cationic reaction is initiated by an acidic cation that allows stress relaxation, thereby, reducing polymerization contraction of the composite6,25. The Filtek® P90 composite is characterized by a special resin matrix chemistry that differs from the commonly known dental composites based on dimethacrylate resin. It is made up of silorane resin, which composed mainly of siloxane and oxirane moieties6. This new monomer is capable of being polymerized and continuing the cationic reaction in dark which is called self or dark polymerization26. The dark reaction usually is time dependent and may attribute to the strength and hardness of the material27.

The microhardness recorded immediately after polymerization showed lesser value than that measured after ½ an hour post-irradiation aging period. After the cessation of light irradiation, the surface hardness did not remain steady but continued to raise after ½ an hour reaching high level at 24 and 168 hours. All the materials investigated were significantly harder at 168 hours compared to other aging periods examined. Previous studies revealed a significant improvement in hardness following post-curing13,14,28. Approximately, 75% of the polymerization reaction of resin composites takes place during the first 10 minutes and continues for a period of 24 hours29,30,1. This may explain the slight increase in hardness after 1 day, which is in agreement with previous studies28,31.

Change in the hardness property may reflect the state of curing the material and the continuation of the setting reaction32. The polymerization reaction cannot be considered finished after exposure to light due to the presence of what is called "dark polymerization". This gradual development of surface hardness of the materials may be correlated to a substantial increase in the degree of polymerization or maturation status of the material28. It can be explained by the presence of a temporary excess of free volume of monomers with enough mobility that allows molecules to still interact at lower rates31. It has been reported that the values of resin conversion for most of the commercial dental composites vary from 40-75%33,29. This incomplete conversion resulted from the type of the material and polymerization may yield in 25 to 60% of nonreacted residual monomers. These free monomers can continue the polymerization reaction by increasing temperature34. In this study, it was noted that when the composites aged at body temperature (37 °C), the hardness increases. Therefore, temperature has an influence on the degree of conversion and final polymerization of the composites. This can be explained by the fact that increasing temperature will cause acceleration of the mobility and polymerization rate of remaining free monomers. Previously, it has been shown that surface hardness of dental composites is significantly affected by temperature35,36.

Moreover, high VHN value exhibited by Definite can be explained by its composition which is based on ormocer (organically modified ceramics) composed of inorganic-organic hybrid copolymers that are nearly as hard as glass. It was previously found that larger filler particles of hybrid composite could be a possible consequence of increasing hardness8. A previous result has shown that the ceramic filler produced higher hardness of a composite15. Ormocer-based composite has a Siloxane polymer made up of a multifunctional polycondensate matrix backbone with polymerizable organic units formed by polycondensation8. This reaction yielded 3-D polymeric inorganic condensates forming a complex network made at a nanoscale. The network allows the incorporation of fillers in order to adjust the ormocer's properties8. Therefore, this high-density network of organic matrix together with the presence of hard-glass fillers yielding a hard structure may result into superior surface hardness of the ormocer composite8. This is almost in agreement with Cefaly's study found that Definite-ormocer was significantly hard, but in contradiction with the finding of Manhart37,38.

On the other hand, the nanohybrid Tetric Evoceram composite presented the less hard material compared to Filtek® P90 and Definite. The relatively low filler content and the smaller filler size of this composite may contribute to their low VHN. Tetric Evoceram composite is composed of UDMA resin that may cause a high degree of monomers conversion. The latter can be due to low viscosity of UDMA resin, which increases the mobility of monomers20. It was found that adding TEGDMA to the resin will improve mechanical properties by increasing the molecular mobility and degree of conversion up to 70%39. However, it has been shown that low microhardness associated with higher TEGDMA concentration may be related to its hydrophilicity39. In the contrary, it has been shown previously that nanofilled resin composite gave the highest VHN compared to mirofilled and microhybrid composites. This may be attributed to the presence of small agglomerated or non-agglomerated nanofillers that occupy the spaces between the slightly larger particles resulting in increased filler load in the composite40.

The composite materials showed higher hardness values on the top surface than the base one in all test groups. This can be explained by the higher degree of polymerization that occurs as a result of the closest contact of the light-curing guide to the top surface. When the curing light is applied to composite resin, some of the light rays are absorbed while others are scattered by the composite resulting in reduction or attenuation of light intensity which deceases the effectiveness of cure at the base surface23,32. At the relatively high temperature (37 °C), the base surface of the specimens showed an increase in the microhardness values, which may be attributed to the dark polymerization of the resin.

5. Conclusions

In conclusion, the microhardness of resin composites is influenced by the composition of the resin matrix, temperature and post-irradiation aging. Filtek® P90 based on silorane and Definite based on ormocer resins expressed the highest VHN as compared to nanohybrid composites. Post-irradiation dry aging of silorane-based composite allows gradual development of hardness, which may be attributed to continuous ring-opening reaction known as self or dark polymerization. Definite-ormocer based composite exhibited high VHN due to the presence of unique organically modified ceramics of polycondesate organic-inorganic oligomers.

Received: October 14, 2009;

Revised: November 29, 2009

  • 1. Chung KH and Greener EH. Correlation between degree of conversion, filler concentration and mechanical properties of posterior composite resins. Journal of Oral Rehabilitation 1990; 17(5):487-94.
  • 2. Kim KH, Ong JL and Okuno O. The effect of filler loading and morphology on the mechanical properties of contemporary composites. Journal of Prosthetic Dentistry 2002; 87(6):642-9.
  • 3. Beun S, Glorieux T, Devaux J, Vreven J and Leloup G. Characterization of nanofilled compared to universal and microfilled composites. Dental Materials 2007; 23(1):51-9.
  • 4. Condon JR and Ferracane JL. Reduced polymerization stress through non-bonded nanofiller particles. Biomaterials 2002; 23(18):3807-15.
  • 5. Mitra SB, Wu D and Holmes BN. An application of nanotechnology in advanced dental materials. The Journal of the American Dental Association 2003; 134(10):1382-90.
  • 6. Guggenberger R and Weinmann W. Exploring beyond methacrylates. American Journal of Dentistry 2000; 13(Spec No):82D-4D.
  • 7. Fong H, Dickens SH and Flaim GM. Evaluation of dental restorative composites containing polyhedral oligomeric silsesquioxane methacrylate. Dental Materials 2005; 21(6):520-9.
  • 8. Haas K and Wolter H. Synthesis, properties and applications of inorganic-organic copolymers (ORMOCERs). Current Opinion in Solid State and Materials Science 1999; 4(6):571-80.
  • 9. Bowen RL. Use of epoxy resins in restorative materials. Journal of Dental Research. 1956; 35(3):360-9.
  • 10. Schweikl H, Schmalz G and Weinmann W. Mutagenic activity of structurally related oxiranes and siloranes in Salmonella typhimurium. Mutation Research. 2002; 521(1-2):19-27.
  • 11. Palin WM, Fleming GJ, Nathwani H, Burke FJ and Randall RC. In vitro cuspal deflection and microleakage of maxillary premolars restored with novel low-shrink dental composites. Dental Materials. 2005; 21(4):324-35.
  • 12. Yap AU. Post-irradiation hardness of resin-modified glass ionomer cements and a polyacid-modified composite resin. Journal of Materials Science: Materials in Medicine 1997; 8(7):413-6.
  • 13. Leung R, Fan P and Johnston W. Post-irradiation Polymerization of Visible Light-activated Composite Resin. Journal of Dental Research 1983; 62(3):363-65.
  • 14. Watts DC, Amer OM and Combe EC. Surface hardness development in light-cured composites. Dental Materials 1987; 3(5):265-9.
  • 15. Roy S and Basu B. Hardness properties and microscopic investigation of crack-crystal interaction in SiO(2)-MgO-Al (2)O (3)-K (2)O-B (2)O (3)-F glass ceramic system. Journal of Materials Science: Materials in Medicine 2009; September15.DOI 10.1007/s10856-009-3853-7. Present status: under publication.
  • 16. Hubbezoglu I, Bolayir G, Dogan OM, Dogan A, Ozer A and Bek B. Microhardness evaluation of resin composites polymerized by three different light sources. Dental Materials Journal 2007; 26(6):845-53.
  • 17. Eldiwany M, Powers JM and George LA. Mechanical properties of direct and post-cured composites. American Journal of Dentistry 1993; 6(5):222-4.
  • 18. Greener EH, Greener CS and Moser JB. The hardness of composites as a function of temperature. Journal of Oral Rehabilitation 1984; 11(4):335-40.
  • 19. McCabe JF and Wassell RW. Hardness of model dental composites - the effect of filler volume fraction and silanation. Journal of Materials Science: Materials in Medicine 1999; 10(5):291-4.
  • 20. Reed B, Choi K, Dickens S and Stansbury J. Effect of resin composition on kinetics of dimethacrylate photopolymerization. American Chemistry Society: Polymer Preprints 1997; 38(2):108-9.
  • 21. Pereira SG, Osorio R, Toledano M, Cabrerizo-Vilchez MA, Nunes TG and Kalachandra S. Novel light-cured resins and composites with improved physicochemical properties. Dental Materials 2007; 23(10):1189-98.
  • 22. Ferracane JL. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins. Dental Materials 1985; 1(1):11-4.
  • 23. Lindberg A, Peutzfeldt A and van Dijken JW. Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure. Clinical Oral Investigations 2005; 9(2):71-6.
  • 24. Palin WM, Fleming GJ, Burke FJ, Marquis PM and Randall RC. Monomer conversion versus flexure strength of a novel dental composite. Journal of Dentistry 2003; 31(5):341-51.
  • 25. Palin WM, Fleming GJ, Burke FJ, Marquis PM and Randall RC. The influence of short and medium-term water immersion on the hydrolytic stability of novel low-shrink dental composites. Dental Materials 2005; 21(9):852-63.
  • 26. Decker C, Viet C and Thi H. Photoinitiated cationic polymerization of epoxides. Polymer International 2001; 50(9):986-97.
  • 27. Oréfice RL, Discacciati JAC, Neves AD, Mansur HS and WC J. Material Behaviour In situ evaluation of the polymerization kinetics and corresponding evolution of the mechanical properties of dental composites. Polymer Testing 2003; 22(1):77-81.
  • 28. Pilo R and Cardash HS. Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites. Dental Materials 1992; 8(5):299-304.
  • 29. Eliades GC, Vougiouklakis GJ and Caputo AA. Degree of double bond conversion in light-cured composites. Dental Materials 1987; 3(1):19-25.
  • 30. Ferracane JL and Greener EH. The effect of resin formulation on the degree of conversion and mechanical properties of dental restorative resins. Journal of Biomedical Materials Research 1986; 20(1):121-31.
  • 31. Tarumi H, Imazato S, Ehara A, Kato S, Ebi N and Ebisu S. Post-irradiation polymerization of composites containing bis-GMA and TEGDMA. Dental Materials 1999; 15(4):238-42.
  • 32. Ciccone-Nogueira JC, Borsatto MC, Souza-Zaron WC, Ramos RP and Palma-Dibb RG. Microhardness of composite resins at different depths varying the post-irradiation time. Journal of Applied Oral Science 2007; 15(4):305-9.
  • 33. Chung K and Greener EH. Degree of conversion of seven visible light-cured posterior composites. Journal of Oral Rehabilitation. 1988; 15(6):555-60.
  • 34. Asmussen E. Factors affecting the quantity of remaining double bonds in restorative resin polymers. Scandinavian Journal of Dental Research 1982; 90(6):490-6.
  • 35. Quance SC, Shortall AC, Harrington E and Lumley PJ. Effect of exposure intensity and post-cure temperature storage on hardness of contemporary photo-activated composites. Journal of Dentistry 2001; 29(8):553-60.
  • 36. Hansen E. After-polymerisation of visible light-activated resins: surface hardness vs light source. Scandinavian Journal of Dental research 1983; 91(5):406-10.
  • 37. Cefaly DF, Ferrarezi GA, Tapety CM, Lauris JR and Navarro MF. Microhardness of resin-based materials polymerized with LED and halogen curing units. Brazilian Dental Journal 2005; 16(2):98-102.
  • 38. Manhart J, Kunzelmann KH, Chen HY and Hickel R. Mechanical properties of new composite restorative materials. Journal of Biomedical Materials Research 2000; 53(4):353-61.
  • 39. Asmussen E and Peutzfeldt A. Influence of UEDMA BisGMA and TEGDMA on selected mechanical properties of experimental resin composites. Dental Materials 1998; 14(1):51-6.
  • 40. Hubbezoğlu I, Bolayir G, Doğan OM, Doğan A, Özer A and Bek B. Microhardness evaluation of resin composites polymerized by three different light sources. Dental Material Journal. 2007; 26(6):845-53.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      13 Apr 2010
    • Date of issue
      Mar 2010

    History

    • Received
      14 Oct 2009
    • Accepted
      29 Nov 2009
    ABM, ABC, ABPol UFSCar - Dep. de Engenharia de Materiais, Rod. Washington Luiz, km 235, 13565-905 - São Carlos - SP- Brasil. Tel (55 16) 3351-9487 - São Carlos - SP - Brazil
    E-mail: pessan@ufscar.br