Previous descontamination of the medical surgical materials: study of the efficiency of chemical disinfectants and water and soap

In this experimental study we compared the previous descontamination efficacy of the medical surgical materials by the use of chemical disinfectants and the mechanical cleaning with water and soap, as well as verified the organic material interference in these procedures. To carry out this study, we used surgical pincers under contamination with: Staphylococcus aureus ATCC-6538, Salmonella cholerae suis ATCC-10708, and Pseudomonas aeruginosa ATCC-15442 in presence and absence of organic matter (fetal bovine serum). The following treatments: glutaraldehyde 2%, sodium hypochlorite 1%, hydrogen peroxide 6%, alcohol 70% and the mechanical cleaning with water and soap were compared with eight repetitions in a total of 480 observations. In the described conditions, the disinfectants had a good efficacy in the previous descontamination of the medical surgical materials and a less inativation by the organic material. The mechanical cleaning with water and soap showed a reduction of the microrganism to safe levels, considered adequate for previous descontamination.

nosocomial infection; previous descontamination