Effects of different levels of end-expiratory pressure on hemodynamic, respiratory mechanics and systemic stress response during laparoscopic cholecystectomy

Abstract

Objective:

General anesthesia causes reduction of functional residual capacity. And this decrease can lead to atelectasis and intrapulmonary shunting in the lung. In this study we want to evaluate the effects of 5 and 10 cmH2O PEEP levels on gas exchange, hemodynamic, respiratory mechanics and systemic stress response in laparoscopic cholecystectomy.

Methods:

American Society of Anesthesiologist I-II physical status 43 patients scheduled for laparoscopic cholecystectomy were randomly selected to receive external PEEP of 5 cmH2O (PEEP 5 group) or 10 cmH2O PEEP (PEEP 10 group) during pneumoperitoneum. Basal hemodynamic parameters were recorded, and arterial blood gases (ABG) and blood sampling were done for cortisol, insulin and glucose level estimations to assess the systemic stress response before induction of anesthesia. Thirty minutes after the pneumoperitoneum, the respiratory and hemodynamic parameters were recorded again and ABG and sampling for cortisol, insulin, and glucose levels were repeated. Lastly hemodynamic parameters were recorded; ABG analysis and sampling for stress response levels were taken after 60 minutes from extubation.

Results:

There were no statistical differences between the two groups about hemodynamic and respiratory parameters except mean airway pressure (P mean). P mean, compliance and PaO2; pH values were higher in 'PEEP 10 group'. Also, PaCO2 values were lower in 'PEEP 10 group'. No differences were observed between insulin and lactic acid levels in the two groups. But postoperative cortisol level was significantly lower in 'PEEP 10 group'.

Conclusion:

Ventilation with 10 cmH2O PEEP increases compliance and oxygenation, does not cause hemodynamic and respiratory complications and reduces the postoperative stress response.

KEYWORDS
PEEP; Hemodynamic; Respiratory mechanics and stress response

Resumo

Objetivo:

A anestesia geral causa a redução da capacidade residual funcional e essa diminuição pode levar à atelectasia pulmonar e ao shunt intrapulmonar. Neste estudo pretendemos avaliar os efeitos de níveis de 5 e 10 cmH2O de pressão expiratória final positiva (PEEP) sobre as trocas gasosas, a hemodinâmica, a mecânica respiratória e a resposta ao estresse sistêmico em colecistectomia laparoscópica.

Método:

Foram selecionados aleatoriamente 43 pacientes, estado físico ASA I-II, agendados para colecistectomia laparoscópica, para receber PEEP a 5 cmH2O (grupo PEEP-5) ou PEEP de 10 cmH2O (grupo PEEP-10) durante o pneumoperitônio. Os parâmetros hemodinâmicos foram registrados, gasometria arterial e coleta de sangue foram feitas para estimativa dos níveis de cortisol, insulina e glicose para avaliar a resposta ao estresse sistêmico antes da indução anestésica. Trinta minutos após o pneumoperitônio, os parâmetros hemodinâmicos e respiratórios foram registrados novamente e gasometria e amostragem para os níveis de cortisol, insulina e glicose foram repetidos. E os últimos parâmetros hemodinâmicos foram registrados, análise e amostragem de gasometria para os níveis de resposta ao estresse foram feitas após 60 minutos da extubação.

Resultados:

Não houve diferença estatística entre dois grupos quanto aos parâmetros hemodinâmicos e respiratórios, exceto pressão média das vias aéreas (Pmédia). Os valores de Pmédia, complacência, PaO2 e do pH foram maiores no grupo PEEP-10. Também os valores de PaCO2 foram menores no grupo PEEP-10. Não foram observadas quaisquer diferenças entre os níveis de insulina e de ácido láctico nos dois grupos. Porém, o nível de cortisol no pós-operatório foi significativamente menor no grupo PEEP-10.

Conclusão:

Ventilação com PEEP de 10 cmH2O aumenta a complacência e a oxigenação, não causa hemodinâmica e complicações respiratórias e reduz a resposta ao estresse no pós-operatório.

PALAVRAS-CHAVE
PEEP; Hemodinâmica; Mecânica respiratória e resposta ao estresse

Introduction

General anesthesia causes reduction of functional residual capacity (FRC) due to decreased inspiratory muscle tone, increased abdominal pressure and altered thoracic volume.11 Meninger D, Byhahn C, Westphal K. Positive end-expiratory pressure improves arterial oxygenation during prolonged pneumoperitoneum. Acta Anaesthesiol Scand. 2005;49:778-83. Changing the erect position to the supine position causes a loss of about 20% FRC, and induction of anesthesia causes a further loss of 10%.22 Lumb AB, Nunn JF. Respiratory function and ribcage contribution to ventilation in body position commonly used during anesthesia. Anesth Analg. 1991;73:422-6. Also, the increased abdominal pressure during laparoscopic procedures results in additional loss of FRC. This decrease in FRC can lead to atelectasis and formation of intrapulmonary shunting in the depended lung regions.33 Hardman JG, Artkenhead AR. Estimating alveolar dead space from the alveolar to end-tidal CO2 gradient: a modeling analysis. Anesth Analg. 2003;97:1845-51. Perioperative atelectasis affects gas exchange and is accepted as a major cause for development of postoperative hypoxia.44 Hedenstierna G, Edmark L. The effects of anesthesia and muscle paralysis on the respiratory system. Intensive Care Med. 2005;31:1327-35. Ventilation with lower tidal volume and application of positive end-expiratory pressure (PEEP) improve outcome in acute respiratory distress syndrome (ARDS) and has become a routine strategy for the treatment of the patient with ARDS.55 Petrucci N, De Feo C. Lung protective strategy for the acute respiratory distress syndrome. Cochrane Database Syst Rev. 2013;2:CD003844. However, recent meta-analyses have sustained that ventilation during general anesthesia with lower tidal volumes and PEEP can also benefit patients without ARDS.66 Serpa Neto A, Cardoso SO, Manetta JA, et al. Association between use of lung-protective ventilation with lower tidal volumes and clinical outcomes among patients without acute respiratory distress syndrome: a meta-analysis. JAMA. 2012;308:1651-9. Also, application of PEEP has been shown to be effective in preventing atelectasis during anesthesia. PEEP is a frequently employed strategy in anesthesiology, but it has capacity to harm as well as to yield beneficial outcomes.77 Terragni PP, Rosboch G, Tealdi A, et al. Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome. Am J Respir Crit Care Med. 2007;175:160-6. Depending on the PEEP level, a decrease in cardiac output (CO) can be induced through increased intrathoracic pressure (ITP) and reduced ventricular preload and systemic venous return pressure gradient.88 Russo A, Marana E, Viviani D, et al. Diastolic function: the influence of pneumoperitoneum and Trendelenburg positioning during laparoscopic hysterectomy. Eur J Anaesthesiol. 2009;26:923-7.

This study was undertaken to evaluate the effects of different PEEP levels on gas exchange, hemodynamics and stress response in the settings of increased intra-abdominal pressure (IAP) created by CO2 pneumoperitoneum for laparoscopic cholecystectomy.

Methods

This prospective randomized study was conducted with the approval of the institute's research and ethics committee and after obtaining written informed consent from 43 patients, aged 18-65 years and of American Society of Anesthesiologist (ASA) I-II physical status, scheduled for laparoscopic cholecystectomy. Patients with morbid obesity (BMI more than 30 kg m-2) or history of diabetes mellitus, endocrine, respiratory, cardiopulmonary and cerebrovascular diseases were excluded from the study. Also, only the cases admitted to the theater until 11:00 A.M. were included in this study. The patients were randomly selected, by opening sealed envelopes, to receive either external PEEP of 5 cmH2O (PEEP 5 group, n = 20) or external PEEP of 10 cmH2O (PEEP 10 group, n = 23) during pneumoperitoneum.

In the operating theater, baseline electrocardiogram (ECG), heart rate (HR), systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP), hemoglobin oxygen saturation (SpO2) and end-tidal carbon dioxide (ETCO2) were recorded using a multiparameter monitor. Baseline arterial blood gases (ABG) were measured and blood sampling was done for cortisol, insulin and glucose level estimations to assess the systemic stress response. Anesthesia was induced by 2 mg kg-1 propofol, 2 µg kg-1 fentanyl citrate, and 0.6 mg kg-1 rocuronium bromide. Anesthesia was maintained with 1.0 MAC of sevoflurane in a mixture of 50% oxygen and air and the ventilator was set with 8 mL kg-1 tidal volume calculated using the predicted body weight and 12 min respiratory rate with an I:E ratio of 1:2 at fresh gas flow 1 L min-1. The 'PEEP 5 group' received 5 cmH2O PEEP, and the 'PEEP 10 group' received 10 cmH2O PEEP level. Before pneumoperitoneum, HR, MAP, ETCO2, P peak, P plato, and P mean were recorded. Pneumoperitoneum was created by CO2 insufflation and IAP was set to be maintained at 14 mm Hg-1 by means of an automatic insufflator. Thirty minutes after the pneumoperitoneum, the respiratory and hemodynamic parameters were recorded again and ABG and sampling for cortisol, insulin, glucose levels were repeated. Anesthesia was maintained until the end of surgery, neuromuscular blockade was antagonized with sugammadex and tracheal extubation was carried out when the patient was fully awake. Recording of hemodynamic parameters and ABG, and sampling for cortisol, insulin, glucose levels were repeated for the last time at 60 min after extubation.

Statistical analysis

Windows program SPSS 15.0 was used for the statistical analysis of the results. Descriptive statistics were given in terms of numbers and percentages for categorical variables, and in terms of the mean, standard deviation and the median for the numerical variables. Comparison of two independent groups of variables was carried out using the Student t test when meeting the normal distribution criteria, or by the Mann-Whitney U test when these criteria were not met. Relationship between numerical variables was assessed by means of the Spearman Correlation Analysis. The differences between categorical variables were evaluated by the Chi-square analysis. Statistical α (alpha) significance level was accepted with the p-value below 0.05.

Results

Physical characteristics and demographic parameters of the two patient groups were closely comparable. Also, there were no statistically significant differences between the two groups with respect to the hemodynamic parameters (HR, SAP, DAP, and MAP) and the respiratory parameters of P peak and P plato levels. But the mean airway pressure (P mean) and compliance levels were statistically higher in PEEP 10 group before and during the pneumoperitoneum time (Table 1).

Table 1
Before and during the pneumoperitoneum time.

The mean ETCO2 levels were same for the two groups. Although no differences were observed in the PaO2 values between the two groups preoperatively and in the postoperative period, the values were higher in the 'PEEP 10 group' over the duration of pneumoperitoneum (Table 2, Fig. 1). Before pneumoperitoneum and during pneumoperitoneum time, PaCO2 values were lower in 'PEEP 10 group' (Table 1, Fig. 2). Mean pH values of the 'PEEP 10 group' were higher than those of the 'PEEP 5 group' (p < 0.01) (Table 2, Fig. 3). Postoperative mean cortisol level of the 'PEEP 10 group' was significantly lower than that of the other group (p < 0.001) (Table 2, Fig. 4). No differences were observed between the insulin and lactic acid levels the two groups. Preoperative glucose level of the 'PEEP 10 group' was higher than that of the 'PEEP 5 group' (p < 0.05) (Table 2, Fig. 5).

Table 2
Over the duration of pneumoperitoneum.
Figure 1
Changes in PaO2 levels (PaO2 1, preoperative time; PaO2 2, peroperative time; PaO2 3, postoperative time).
Figure 2
Changes in PaCO2 levels (PaCO2 1, preoperative time; PaCO2 2, peroperative time; PaCO2 3, postoperative time).
Figure 3
Changes in pH levels (pH 1, preoperative time; pH 2, peroperative time; pH 3, postoperative time).
Figure 4
Changes in cortisol levels (Cortisol 1, preoperative time; Cortisol 2, peroperative time; Cortisol 3, postoperative time cortisol values).
Figure 5
Changes in glucose levels (Glucose 1, preoperative time; Glucose 2, peroperative time; Glucose 3, postoperative time values).

Discussion

This study aimed to demonstrate the effects of the application of 5 cmH2O PEEP versus 10 cmH2O PEEP during pneumoperitoneum in laparoscopic abdominal surgery on any improvement on oxygenation and compliance, prevention of atelectasis and the differences in changes in the respiratory, hemodynamic parameters and the systemic stress response.

Recent reports have demonstrated that application of PEEP during general anesthesia, especially for laparoscopic surgery, improves compliance and oxygenation.99 Karsten J, Luepschen H, Grossherr M, et al. Effect of PEEP on regional ventilation during laparoscopic surgery monitored by electrical impedance tomography. Acta Anaesthesiol Scand. 2011;55:878-86. In a study to evaluate the effect on cerebral oxygen saturation of 0 cmH2O PEEP and of 10 cmH2O PEEP application during laparoscopic cholecystectomy, Hyun et al. concluded that 10 cmH2O PEEP usage saved cerebral oxygen saturation without adverse effects on hemodynamic stability.1010 Hyun JK, Sun KP, Kyung CL, et al. High positive end-expiratory pressure preserves cerebral oxygen saturation during laparoscopic cholecystectomy under propofol anesthesia. Surg Endosc. 2013;27:415-20. In another study, employing 14, 8 and 14 mm Hg-1 IAP pressure, respectively, on groups given 0, 5 and 10 cmH2O PEEP, they observed that application of PEEP at the corresponding IAP helped maintain CO2 elimination and improved oxygenation without hemodynamic disturbance.1111 Pankaj K, Yamini S, Ravishankar M, et al. Cardiorespiratory effects of balancing PEEP with intra-abdominal pressure during laparoscopic cholecystectomy. Surg Laparosc Endosc Percutan Tech. 2014;24:232-9. Furthermore, the review by the Cochrane Collaboration group on postoperative mortality and pulmonary complications with and without use of PEEP has suggested, albeit inconclusively, that PEEP improves postoperative atelectasis and oxygenation.1212 Fabiona TB, Aldemar AC, Celio FS. Postoperative end-expiratory pressure (PEEP) during anaesthesia for prevention of mortality and postoperative pulmonary complications. Cochrane Database Syst Rev. 2014. Art. No: CD007922.

On the other hand, the PROVHILO trial with 900 cases of open abdominal surgery under general anesthesia with 8 mL kg-1 tidal volume and recruitment, using either 2 cmH2O PEEP or 12 cmH2O PEEP, did not demonstrate significant differences between the two groups with respect to postoperative pulmonary complications despite the higher preoperative oxygenation values in the 12 cmH2O PEEP group, and the greater need of oxygenation by the 2 cmH2O PEEP group. They concluded that elevated PEEP and recruitment maneuver in open abdominal surgery did not protect against pulmonary complications and mortality, and defended the ventilation strategy without low tidal volume, low level PEEP and recruitment.1313 The PROVE Network Investigators for the Clinical Trial Network of the European Society of Anaesthesiology. High versus low positive end-expiratory pressure during general anaesthesia for open abdominal surgery (PROVHILO trial): a multicenter randomised controlled trial. Lancet. 2014;384:495-503.

When levels of 0, 5, 10 and 15 cmH2O PEEP were applied in cardiac surgery, it was reported that as the PEEP level was increased, respiratory system total resistance and elastic recoil were decreased; oxygenation and CO2 elimination increased; dead space and shunting were decreased; arterial oxygen content, oxygen consumption and the oxygen extraction rate were increased despite the progressive reduction in the cardiac index; and no differences in the mean arterial blood pressure was demonstrable between the different PEEP groups. It was concluded that although application of PEEP above the 10 cmH2O PEEP level increased oxygenation, it should be cautiously applied especially in patients with marginal cardiac function due to contractility disturbances or hypovolemia.1414 Auler JOC, Carmona MJC, Barbas CV, et al. The effects of positive end-expiratory pressure on respiratory system mechanics and hemodynamics in postoperative cardiac surgery patients. Braz J Med Biol Res. 2000;33:31-42. Daniel et al., after evaluating the effects of 5, 8 and 10 cmH2O PEEP applications on the duration of mechanical ventilation after coronary artery bypass grafting surgery, reported a significantly shortened ventilation time in the 10 cmH2O PEEP group.1515 Daniel LB, Vinicius JSN, Thiago EPB, et al. Effects of positive end-expiratory pressure on mechanical ventilation duration after coronary artery bypass grafting: a randomized clinical trial. Ann Thorac Cardiovasc Surg. 2014;20:773-7. Karsten et al. evaluated regional ventilation using electrical impedance tomography on 32 patients undergoing laparoscopic cholecystectomy either with 0 (zero) cmH2O PEEP (the ZEEP application) or 10 cmH2O PEEP. They reported that recruitment maneuver and 10 cmH2O PEEP application in laparoscopic surgery improved oxygenation and corrected compliance.99 Karsten J, Luepschen H, Grossherr M, et al. Effect of PEEP on regional ventilation during laparoscopic surgery monitored by electrical impedance tomography. Acta Anaesthesiol Scand. 2011;55:878-86. The same group of authors investigated the effects of 0, 3, 5, 7 and 10 cmH2O PEEP application during robot-assisted laparoscopic radical prostate surgery on the hemodynamic and respiratory parameters. They reported that HR and MAP values did not vary with the PEEP level, but the PaO2 level was significantly low in the ZEEP group of patients and most elevated in the 10 cmH2O PEEP group. One patient in the 10 PEEP group had subcutaneous emphysema resolved after cessation of the insufflation. They concluded that application of 7 cmH2O PEEP resulted in significant oxygenation augmentation without excessive peak airway pressure or depression of hemodynamic parameters during prolonged laparoscopic surgery.1616 Hee JL, Kyo SK, Ji SJ, et al. Optimal positive end-expiratory pressure during robot-assisted laparoscopic radical prostatectomy. Korean J Anesthesiol. 2013;65:244-50.

In our study, we observed that during the pneumoperitoneum period, PaO2, compliance, P mean, and pH levels were higher in the 10 cmH2O PEEP group as compared to the 5 cmH2O PEEP group. Although 5 cmH2O PEEP preserved oxygenation during pneumoperitoneum, 10 cmH2O PEEP produced a significant improvement in oxygenation. Similar observations were made by Andrea et al. during laparoscopic gynecological surgery. PEEP application resulted in recruitment in the alveoli, improving cardiac and pulmonary functions and thereby improving oxygenation, enhancing CO2 washout and inhibition of the vasoconstrictor reflex.

It was argued that while 5 cmH2O of PEEP acted as a shield against the negative cardiopulmonary effects induced by pneumoperitoneum, 10 cmH2O of PEEP actually improved the effects.1717 Andrea R, Enrico DS, Alessandro S, et al. Positive end-expiratory pressure during laparoscopy: cardiac and respiratory effects. J Clin Anesth. 2013;25:314-20. Although the most common complications of high PEEP application are observed in the hemodynamic parameters, especially in hypovolemic patients, on including respiratory effects such as barotrauma, we did not encounter hemodynamic or respiratory complications in our series of patients. In patients undergoing laparoscopic inguinal hernia surgery with application of 8 mL kg-1 tidal volume with 0, 5 and 10 cmH2O PEEP, end-expiratory lung volume (EELV), measured with the nitrogen wash-out/wash-in method using electrical impedance tomography, was increased during application of 10 cmH2O PEEP which also homogenized ventilation distribution.1818 Julien B, Cecilia M, Philippe JC, et al. Impact of extraperitoneal dioxide carbon insufflation on respiratory function in anesthetized adults: a preliminary study using electrical impedance tomography and wash-out/wash-in technic. Anesth Pain Med. 2015;5:e22845.

We observed, when evaluating the effects of 5 and 10 cmH2O PEEP application on the systemic stress response, that preoperative blood glucose levels, although significantly elevated, were still within the physiological limits in the 10 cmH2O PEEP group, while the cortisol level was significantly lower in postoperative time and the insulin level was unmodified as compared to the 5 cmH2O PEEP group. We could not find another study in the literature on the effects of PEEP level on the systemic stress response parameters to be able to make direct comparisons on the results.

However, in studies evaluating the inflammatory response, it was found out that PEEP was beneficial at high inspiratory pressure and caused some stress, but imposed only moderate stress at low inspiratory pressure.1919 Meier T, Lange A, Papenberg H, et al. Pulmonary cytokine responses during mechanical ventilation of noninjured lungs with and without end-expiratory pressure. Anesth Analg. 2008;107:1265-75. Weingarten et al. compared the effects of 'low tidal volume with high (12 cmH2O) PEEP' application versus 'high tidal volume with ZEEP (0 cmH2O PEEP) application' on the systemic inflammatory response parameters IL-6 and IL-8, and found no differences between the two groups. But the perioperative oxygenation of the 'low tidal volume and 12 cmH2O PEEP' group was increased and lung mechanics were much better.2020 Weingarten TN, Whalen FX, Warner DO, et al. Comparison of two ventilator strategies in elderly patients undergoing major abdominal surgery. Br J Anaesth. 2010;104:16-22. In our study, the observation of low postoperative cortisol levels with 10 cmH2O PEEP application may be related to better peroperative oxygenation and compliance.

Conclusion

We believe that during laparoscopic cholecystectomy surgery, ventilation with 10 cmH2O PEEP increases compliance and oxygenation does not cause hemodynamic and respiratory complications and reduces the postoperative stress response with this study.

References

  • 1
    Meninger D, Byhahn C, Westphal K. Positive end-expiratory pressure improves arterial oxygenation during prolonged pneumoperitoneum. Acta Anaesthesiol Scand. 2005;49:778-83.
  • 2
    Lumb AB, Nunn JF. Respiratory function and ribcage contribution to ventilation in body position commonly used during anesthesia. Anesth Analg. 1991;73:422-6.
  • 3
    Hardman JG, Artkenhead AR. Estimating alveolar dead space from the alveolar to end-tidal CO2 gradient: a modeling analysis. Anesth Analg. 2003;97:1845-51.
  • 4
    Hedenstierna G, Edmark L. The effects of anesthesia and muscle paralysis on the respiratory system. Intensive Care Med. 2005;31:1327-35.
  • 5
    Petrucci N, De Feo C. Lung protective strategy for the acute respiratory distress syndrome. Cochrane Database Syst Rev. 2013;2:CD003844.
  • 6
    Serpa Neto A, Cardoso SO, Manetta JA, et al. Association between use of lung-protective ventilation with lower tidal volumes and clinical outcomes among patients without acute respiratory distress syndrome: a meta-analysis. JAMA. 2012;308:1651-9.
  • 7
    Terragni PP, Rosboch G, Tealdi A, et al. Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome. Am J Respir Crit Care Med. 2007;175:160-6.
  • 8
    Russo A, Marana E, Viviani D, et al. Diastolic function: the influence of pneumoperitoneum and Trendelenburg positioning during laparoscopic hysterectomy. Eur J Anaesthesiol. 2009;26:923-7.
  • 9
    Karsten J, Luepschen H, Grossherr M, et al. Effect of PEEP on regional ventilation during laparoscopic surgery monitored by electrical impedance tomography. Acta Anaesthesiol Scand. 2011;55:878-86.
  • 10
    Hyun JK, Sun KP, Kyung CL, et al. High positive end-expiratory pressure preserves cerebral oxygen saturation during laparoscopic cholecystectomy under propofol anesthesia. Surg Endosc. 2013;27:415-20.
  • 11
    Pankaj K, Yamini S, Ravishankar M, et al. Cardiorespiratory effects of balancing PEEP with intra-abdominal pressure during laparoscopic cholecystectomy. Surg Laparosc Endosc Percutan Tech. 2014;24:232-9.
  • 12
    Fabiona TB, Aldemar AC, Celio FS. Postoperative end-expiratory pressure (PEEP) during anaesthesia for prevention of mortality and postoperative pulmonary complications. Cochrane Database Syst Rev. 2014. Art. No: CD007922.
  • 13
    The PROVE Network Investigators for the Clinical Trial Network of the European Society of Anaesthesiology. High versus low positive end-expiratory pressure during general anaesthesia for open abdominal surgery (PROVHILO trial): a multicenter randomised controlled trial. Lancet. 2014;384:495-503.
  • 14
    Auler JOC, Carmona MJC, Barbas CV, et al. The effects of positive end-expiratory pressure on respiratory system mechanics and hemodynamics in postoperative cardiac surgery patients. Braz J Med Biol Res. 2000;33:31-42.
  • 15
    Daniel LB, Vinicius JSN, Thiago EPB, et al. Effects of positive end-expiratory pressure on mechanical ventilation duration after coronary artery bypass grafting: a randomized clinical trial. Ann Thorac Cardiovasc Surg. 2014;20:773-7.
  • 16
    Hee JL, Kyo SK, Ji SJ, et al. Optimal positive end-expiratory pressure during robot-assisted laparoscopic radical prostatectomy. Korean J Anesthesiol. 2013;65:244-50.
  • 17
    Andrea R, Enrico DS, Alessandro S, et al. Positive end-expiratory pressure during laparoscopy: cardiac and respiratory effects. J Clin Anesth. 2013;25:314-20.
  • 18
    Julien B, Cecilia M, Philippe JC, et al. Impact of extraperitoneal dioxide carbon insufflation on respiratory function in anesthetized adults: a preliminary study using electrical impedance tomography and wash-out/wash-in technic. Anesth Pain Med. 2015;5:e22845.
  • 19
    Meier T, Lange A, Papenberg H, et al. Pulmonary cytokine responses during mechanical ventilation of noninjured lungs with and without end-expiratory pressure. Anesth Analg. 2008;107:1265-75.
  • 20
    Weingarten TN, Whalen FX, Warner DO, et al. Comparison of two ventilator strategies in elderly patients undergoing major abdominal surgery. Br J Anaesth. 2010;104:16-22.

Publication Dates

  • Publication in this collection
    Jan-Feb 2017

History

  • Received
    9 June 2015
  • Accepted
    17 Aug 2015
Sociedade Brasileira de Anestesiologia R. Professor Alfredo Gomes, 36, 22251-080 Botafogo RJ Brasil, Tel: +55 21 2537-8100, Fax: +55 21 2537-8188 - Campinas - SP - Brazil
E-mail: bjan@sbahq.org