Acessibilidade / Reportar erro

Late auditory event-related evoked potential (P300) in Down's syndrome patients

Abstracts

Down syndrome is caused by a trisomy of chromosome 21 and is associated with central auditory processing deficit, learning disability and, probably, early-onset Alzheimer's disease. AIM: to evaluate the latencies and amplitudes of evoked late auditory potential related to P300 events and their changes in young adults with Down's syndrome. MATERIALS AND METHODS: Prospective case study. P300 test latency and amplitudes were evaluated in 17 individuals with Down's syndrome and 34 healthy individuals. RESULTS The P300 latency (N1, P2, N2 and P3) was longer and the N2-P3 amplitude was lower in individuals with Down syndrome when compared to those in the control group. CONCLUSION: In young adults with Down syndrome, N1, P2, N2 and P3 latencies of late auditory evoked potential related to P300 events were prolonged, and N2 - P3 amplitudes were significantly reduced, suggesting integration impairment between the auditory association area and cortical and subcortical areas of the central nervous system.

down syndrome; p300; event-related potentials


A síndrome de Down é causada pela trissomia do cromossomo 21 e está associada com alteração do processamento auditivo, distúrbio de aprendizagem e, provavelmente, início precoce de Doença de Alzheimer. OBJETIVO: Avaliar as latências e amplitudes do potencial evocado auditivo tardio relacionado a eventos (P300) e suas alterações em indivíduos jovens adultos com síndrome de Down. MATERIAL E MÉTODO: Estudo de caso prospectivo. Latências e amplitudes do P300 foram avaliadas em 17 indivíduos com síndrome de Down e 34 indivíduos sadios. RESULTADOS: Foram identificadas latências do P300 (N1, P2, N2 e P3) prolongadas e amplitude N2 - P3 diminuída nos indivíduos com síndrome de Down quando comparados ao grupo controle. CONCLUSÃO: Em indivíduos jovens adultos com síndrome de Down ocorre aumento das latências N1, P2, N2 e P3, e diminuição significativa da amplitude N2-P3 do potencial evocado auditivo tardio relacionado a eventos (P300), sugerindo prejuízo da integração da área de associação auditiva com as áreas corticais e subcorticais do sistema nervoso central.

envelhecimento; potencial evocado p300; síndrome de down


ORIGINAL ARTICLE

Late auditory event-related evoked potential (P300) in Down's syndrome patients

Carla Patrícia Hernandez Alves Ribeiro CésarI; Heloisa Helena CaovillaII; Mário Sérgio Lei MunhozIII; Maurício Malavasi GanançaIV

IDoctorate in the science of communication disorders, Sao Paulo Federal University, Paulista Medical School. Professor and coordinator of the speech therapy course at the Sao Paulo Methodist University. São Paulo Methodist University

IISpeech therapist; doctoral degree; associate professor of the otology and otoneurology discipline at the Sao Paulo Federal University, Paulista Medical School. São Paulo Methodist University

IIIPhysician, otorhinolaryngologist, doctoral degree. Associate professor of the otology and otoneurology discipline at the Sao Paulo Federal University, Paulista Medical School. São Paulo Methodist University

IVPhysician, otorhinolaryngologist, doctoral degree. Full professor of the Sao Paulo Federal University, Paulista Medical School. Professor of the master's degree program on vestibular rehabilitation and social inclusion of the Sao Paulo Bandeirante University. São Paulo Methodist University

Send correspondence to

SUMMARY

Down syndrome is caused by a trisomy of chromosome 21 and is associated with central auditory processing deficit, learning disability and, probably, early-onset Alzheimer's disease.

AIM: to evaluate the latencies and amplitudes of evoked late auditory potential related to P300 events and their changes in young adults with Down's syndrome.

MATERIALS E METHODS: Prospective case study. P300 test latency and amplitudes were evaluated in 17 individuals with Down's syndrome and 34 healthy individuals.

RESULTS: The P300 latency (N1, P2, N2 and P3) was longer and the N2-P3 amplitude was lower in individuals with Down syndrome when compared to those in the control group.

CONCLUSION: In young adults with Down syndrome, N1, P2, N2 and P3 latencies of late auditory evoked potential related to P300 events were prolonged, and N2 - P3 amplitudes were significantly reduced, suggesting integration impairment between the auditory association area and cortical and subcortical areas of the central nervous system.

Keywords: down syndrome, p300, event-related potentials.

INTRODUCTION

Langdon Down described Down's syndrome, or the chromosome 21 trisomy, over a century ago; it is considered the most common genetic cause of mental retardation.1 The typical chromosomal changes in this syndrome comprise a homogeneous group2 that makes it easy to understand the findings. Diffuse injury or dysfunction in certain central areas,3 failure in habituation mechanisms,4 poor central inhibition of afferent stimuli,5 or cognition disorders6 may give rise to decreased brain electrical activity in Down's syndrome.

The long latency event-related evoked potential (P300) is associated with cognition;7 it is generated when a random infrequent stimulus is detected among a series of frequent stimuli.7-9 The parameters assessed are latency and amplitude. Latency varies according to an individual's difficulty in discriminating a rare tones among frequent stimuli; amplitude varies according to the improbability of the stimulus.8 Waves N2 and P3 are the most important because they represent physiological phenomena associated with memory and learning mental events.10 Wave N2 is associated with decision-making or discrimination of stimuli;11 absent N2 and P3 waves suggest more severe involvement, such as pre-senile or senile dementia.12

Increased P3 latency and decreased P3 amplitude4-5,13,14-17 have been identified in Down's syndrome. Increased latency appears to be associated with sensory and cognitive deficiencies in information processing, in particular by delaying the categorization of auditory information, and may be due to differences in the brain's ability to organize and respond in Down's syndrome.14

Increased P3 latency and decreased P3 amplitude, seen in healthy ageing individual,18-19 have been found at an earlier age - about 20 years earlier15,20 - in patients with Down's syndrome. A line of theory considers the possibility of an Alzheimer's type pre-senile dementia in subjects with Down's syndrome, underlining the importance of P300 to investigate the triad: ageing/Down's syndrome/Alzheimer's disease.13

The lack of Brazilian papers on the use of P300 in Down's syndrome motivated this study.

The purpose of this study was to assess late event-related auditory evoked potentials (P300) in young adults with Down's syndrome.

MATERIALS AND METHODS

The Institutional Review Board of the institution in which the investigation was carried out approved this study (number 181/96).

We undertook a prospective study comprising subjects aged from 18 to 39 years with a diagnosis of Down's syndrome. These patients were referred from a specialized institution on this condition; their parents or caretakers gave their free permission for each patient to participate. There were 17 subjects (10 male and seven female). Parents or caretakers of the subjects were informed of the study procedures and signed a free informed consent form for P300 to be done on the patients.

The control group consisted of healthy subjects with no neurological or auditory complaints and no history of (or suspected history of) first degree family members with dementia. The control group comprised 34 subjects (20 male and 14 female) aged from 18 to 39 years. This group had twice the number of patients in the Down's syndrome group, to increase test reliability.

Subjects in both groups were asked to refrain from stressful physical and mental activities before undergoing the auditory P300 testing. Those that did not follow this instruction or that slept during the procedure were excluded from the sample.

The Nicolet Compact Auditory (Nicolet Biomedical Instruments) ran the P300 program with the following parameters: pure tone stimulus, frequent tone (EF) at 750 Hz, and rare tone (ER) at 2,000 Hz; binaural presentation mode; 70 dBHL intensity with 700 ms intervals between tones; and a 4/1 proportion for randomly presenting EF/ER (odd ball paradigm). Electrodes were placed on Cz (A1 and A2) and Pz (A1 and A2). TDH-39 earphones were used. About 300 stimuli were presented.

Testing took place in an acoustically isolated and semi-darkened silent room; patients were comfortably seated on a reclining seat with head support. The skin and scalp were cleaned with an abrasive paste (OMNI), after which electrolytic gel was placed between the skin and electrodes to increase conductivity. Electrodes were fixed with microporeT plaster on the frontal (Fpz), vertical (Cz) and parietal (Pz) regions, and left ear (A1) and right ear (A2) lobules, according to the 10-20 international standard.21 The electrodes were connected to a preamplifier, in turn connected to the subject's clothes. Electrode polarity was positive in Cz and Pz, and negative in A1 and A2 (interlinked with a jumper). The electrical impedance was less than 5 KOhms in each derivation, and less than 3 KOhms between two different derivations throughout the procedure.

Electroencephalogram waves were amplified 10,000 times; the bandwidth ranged from 1 to 30 Hz; the sensitivity was about 50mv. Artifacts were rejected by an internal circuit in the device that excluded all recordings with potentials over 45mv from the mediation process. Testing was interrupted if artifacts surpassed 20% of the presented stimuli, and the patient was asked to avoid muscle tension, and eye and body movements; after a 5-minute rest period, the test was restarted.

Study subjects were asked to remain alert and relaxed for testing. They had to raise their hands or a flag gently only for rare tones to demonstrate tone discrimination and attentiveness. At the beginning of the test some of the subjects with Down's syndrome required new instructions, as they raised their hands or the flag and did not bring it down afterwards; the test was restarted only after it was fully understood.

Each procedure lasted about thirty minutes: 15 minutes were required for preparing and placing the electrodes, data entry, and checking the impedance; 3 minutes were needed for the pre-test phase, during which the examiner identified rare tones with each subject until he or she could perform it alone; the test itself took from seven to 10 minutes.

Waves N1, P2, N2 and P3 had, respectively, negative-positive-negative-positive polarities, and were recorded and replicated when frequent and rare tones were presented. N1 and P2 were marked on the frequent tones, and N1, N2 and P3 were marked on rare tones. Latency was measured at the maximum deflection point in each wave, and amplitude was measured between the maximum N1 and P2, and N2 and P3 deflection points. Peaks with the highest deflection or waves that were best duplicated were measured in double, triple or multiple peak waves.22

P300 component latency and amplitude values were tabulated for the control group and the Down syndrome group. The mean latencies and amplitudes in each group were compared and related with gender. The Mann-Whitney test, used for comparing independent samples, was applied for the statistical analysis. The significance level was 5%. Significant data were marked with an asterisk.

RESULTS

There were 51 subjects aged from 18 to 39 years; 30 were male and 21 were female. All were able to perform the test without difficulty.

Table 1 shows N1, P2, N2 and P3 latency values and N1-P2 and N2-P3 amplitude values for 17 subjects with Down's syndrome. Table 2 shows N1, P2, N2 and P3 latency values and N1-P2 and N2-P3 amplitude values of 34 controls.

Tables 3 and 4 show the influence of gender on N1, P2, N2 and P3 latency values and N1-P2 and N2-P3 amplitude values of 17 with Down's syndrome and of controls. The Mann-Whitney test, at a 5% significance level, revealed no statistically significant gender differences.

Table 5 shows a comparison of N1, P2, N2 and P3 mean latencies between both groups. The Down's syndrome group showed a statistically significant increase in N1, P2, N2 and P3 latencies compared to controls.

Table 6 shows a comparison of mean N1-P2 and N2-P3 amplitudes in 17 subjects with Down's syndrome and 34 controls. A statistically significant difference was found in N2-P3 amplitudes, which were lower in the Down's syndrome group compared to controls.

DISCUSSION

In this study, P300 was easy to apply and interpret in subjects with Down's syndrome. All study and control subjects avoided physical activities and stressful mental work before undertaking the auditory P300 test; we were careful to exclude from the sample the subjects that did not follow the instructions, or that were fatigued, inattentive, or that slept during the procedure. The parameters that were assessed were N1, P2, N2 and P3 latencies and N1-P2 and N2-P3 amplitudes. Of 17 subjects with Down's syndrome, 12 (70.6%) showed one or more abnormalities in N2 and P3 latencies and/or N1-P2 and N2-P3 amplitudes. We found delayed N2 latency in 29.4% of cases, delayed N2 and P3 latencies in 23.5%, delayed P3 latency in 5.9%, delayed N2 latency and increased N1-P2 amplitude in 5.9%, and absent N2 and P3 components in 5.9%, compared with the results of healthy subjects23 using the same procedure of raising one's hand upon hearing a rare tone.

We found that N1, P2, N2 and P3 latencies were higher in the Down's syndrome group, which concurred with other studies.5-6,16 The difference of the mean P3 latency between subjects with Down's syndrome and controls was 71 ms, suggesting that the estimated mean age of Down's syndrome subjects would be 96 years,22 which contrasts with their mean reported chronological age (25 years). The literature we reviewed suggested that the P300 test would demonstrate the effects of human ageing,18 observed in a slowing of the stimulus assessment process and decreased selective attention ability;24 P3 latency increases by about one millisecond a year throughout life.22 As the P3 latency is elevated in healthy elderly subjects19 and in Down's syndrome subjects,5,13 we assumed that the early ageing hypothesis17 that is reported in the literature could be applied to our study group. However, the elevation in P3 latency we found might also be related only with sensory and cognitive information processing deficiencies, which would delay categorization of auditory information, and which may have been attributed to differences in the ability of the brain of Down's syndrome subjects to organize information and respond.14

N1-P2 amplitudes were similar in subjects with Down's syndrome and controls, while N2-P3 amplitude was lower in the Down's syndrome group. These results concur with other findings in the literature.16-17 As amplitude decreases with ageing in healthy subjects,18-19 our findings in some subjects with Down's syndrome led us to hypothesize the possibility of early ageing, compared to controls, and point to the neurological and cognitive losses in our study sample. Decreased N2-P3 amplitude might suggest that few fibers are conducting the stimuli, indicating that there might be loss of auditory attentiveness25 and poor cognition.7

Altered P300 latencies and amplitudes may be justified in different theoretical perspectives; there might be failure in cortical habituatioin,4-6 a decreased number of nervous fibers for conducting auditory stimuli,25 the cognitive disorder itself,7 or the possibility of Alzheimer's disease in individuals with Down's syndrome.16

Identifying altered P300 latencies and amplitudes in subjects with Down's syndrome demonstrates the importance of this procedure, suggesting that surveys to monitor the progression of these cases could be undertaken to clarify the behavior of mentally retarded individuals without Down's syndrome, of individuals with Alzheimer's disease, of individuals with neuroendocrine disorders, and of healthy individuals.

CONCLUSION

In young adults with Down's syndrome N1, P2, N2 and P3 latencies were elevated and N2-P3 amplitudes were decreased in the event-related long-latency auditory evoked potential (P300), suggesting loss of integration in the auditory association area with cortical and subcortical areas of the central nervous system.

REFERENCES

  • 1. Thase ME. Longevity and mortality in Down's syndrome. J Ment Defic Res. 1982;26(Pt 3):177-92.
  • 2. Dustman RE, Beck EC. The visually evoked potential in twins. Electroenceph. Clin Neurophysiol. 1965;19:570-5.
  • 3. Duncan-Johnson CC, Donchin E. The P300 component of the event-related brain potential as an index of information processing. Biol Psychol. 1982;14(1-2):1-52.
  • 4. Schafer EW, Peeke HVS. Down syndrome individuals fail to habituate cortical evoked potentials. Am J Ment Defic. 1982;87(3):332-7.
  • 5. Callner DA, Dustman RE, Madsen JA, Schenkenberg T, Beck EC. Life span changes in the averaged evoked responses of Down's syndrome and nonretarded persons. Am J Ment Defic. 1978;82(4):398-405.
  • 6. Dustman RE, Callner DA. Cortical evoked responses and response decrement in nonretarded and Down's syndrome individuals. Am J Ment Defic. 1979;83(4):391-7.
  • 7. Sutton NK, Braren M, Zubin J, John ER. Evoked potential correlates of stimulus uncestanty. Science. 1965;150:1187-8.
  • 8. Picton TW. The P300 wave of the human event-related potential. J Clin Neurophysiol. 1992;9:456-79.
  • 9. Polich J. P300 clinical utility and control of variability. J Clin Neurophysiol. 1998;15:14-33.
  • 10. Hillyard SA, Kutas M. Eletrophysiology of cognitive processing. Ann Rev Psychol. 1983;34:33-61.
  • 11. Iragui V.J, Kutas M, Mitchiner MR, Hillyard SA. Effects of aging of event-related brain potentials and reaction times in an auditory oddball task. Psychophisiol. 1993;30:10-22.
  • 12. Desmedt JE. P300 in serial tasks: an essential postdecision closure mechanisms. Prog Brain Res. 1981;54:682-6.
  • 13. Vieregge P, Verleger R, Schulze-Rava H, Kömpf D. Late cognitive event-related potentials in adult Down's syndrome. Biol Psychiatry. 1992;32(12):1118- 34.
  • 14. Lincoln AJ, Courchesne E, Kilman BA, Galambos R.Neuropsychological correlates of information-processing by children with Down syndrome. Am J Ment Defic. 1985;89(4):403-14.
  • 15. Blackwood DH, St Clair DM, Muir WJ, Oliver CJ, Dickens P. The development of Alzheimers disease in Downs syndrome assessed by auditory event-related potentials. J Ment Defic Res. 1988;32(Pt 6):439-53.
  • 16. Muir WJ, Squire I, Blackwood DH, Speight MD, St Clair DM, Oliver C, Dickens P. Auditory P300 response in the assessment of Alzheimers disease in Downs syndrome: a 2-year follow-up study. J Ment Defic Res. 1988;32(Pt 6):455-63.
  • 17. St Clair DM, Blackwood DHR. Premature senility in Down's Syndrome (letters). Lancet 1985;2(8445):34.
  • 18. Goodin DS, Squires KC, Henderson BH, Starr A. Age-related variations in evoked potentials to auditory stimuli in normal human subjects. Electroencephalogr Clin Neurophysiol. 1978;44(4):447-58.
  • 19. Pfefferbaum A, Ford JM, Wenegrat BG, Roth WT, Kopell BS. Clinical application of the P3 component of event-related potentials I: Normal ageing. Electroenceph Clin Neurophysiol. 1984;59:85-103.
  • 20. St Clair D, Blackwood D, Muir W. P300 abnormality in schizophrenic subtypes. J Psychiatr Res. 1989;23(1):49-55.
  • 21. Jasper HH. Report of the committee on methods of clinical examination in eletroencephalography. Eletroencephalogr Clin Neurophysiol. 1958;10:370-5.
  • 22. Musiek FE, Baran JA, Pinheiro ML. Neuroaudiology case studies. San Diego: Singular; 1994.p.279.
  • 23. César CPHAR, Munhoz MSL. O P300 auditivo em jovens e adultos saudáveis com uma nova proposta de resposta: levantar a mão. Acta AWHO. 1999;18(1):32-7.
  • 24. Kugler CFA, Taghavy A, Platt D. The event-related P300 potential analysis of cognitive human brain aging a review. Gerontol. 1993;39:280-303.
  • 25. Timsit-Berthier M, Gerono A. Manuel d'interprétation dês potentiels evoques endogènes (P300 et VCN). Liège: Mardaga; 1998.p.64.
  • Endereço para correspondência:
    R. Dom Jaime de Barros Câmara 1000
    Bairro Planalto São Bernardo do Campo SP
  • Publication Dates

    • Publication in this collection
      31 May 2010
    • Date of issue
      Apr 2010

    History

    • Received
      13 Jan 2009
    • Accepted
      01 Dec 2009
    Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Sede da Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico Facial, Av. Indianópolia, 1287, 04063-002 São Paulo/SP Brasil, Tel.: (0xx11) 5053-7500, Fax: (0xx11) 5053-7512 - São Paulo - SP - Brazil
    E-mail: revista@aborlccf.org.br