Accessibility / Report Error
Brazilian Oral Research, Volume: 22, Issue: 1, Published: 2008
  • The BOR is changing its submission instruction Editorial

    Rode, Sigmar de Mello
  • Physicochemical characterization of two deproteinized bovine xenografts Biochemistry

    Accorsi-Mendonça, Thais; Conz, Márcio Baltazar; Barros, Teresa Cristina; Sena, Lídia Ágata de; Soares, Glória de Almeida; Granjeiro, José Mauro

    Abstract in English:

    Calcium phosphate salts, or more specifically hydroxyapatite, are products of great interest in the fields of medical and dental science due to their biocompatibility and osteoconduction property. Deproteinized xenografts are primarily constituted of natural apatites, sintered or not. Variations in the industrial process may affect physicochemical properties and, therefore, the biological outcome. The purpose of this work was to characterize the physical and chemical properties of deproteinized xenogenic biomaterials, Bio-Oss (Geistlich Biomaterials, Wolhuser, Switzerland) and Gen-Ox (Baumer S.A., Brazil), widely used as bone grafts. Scanning electron microscopy, infrared region spectroscopy, X-ray diffraction, thermogravimetry and degradation analysis were conducted. The results show that both materials presented porous granules, composed of crystalline hydroxyapatite without apparent presence of other phases. Bio-Oss presented greater dissolution in Tris-HCl than Gen-Ox in the degradation test, possibly due to the low crystallinity and the presence of organic residues. In conclusion, both commercial materials are hydroxyapatite compounds, Bio-Oss being less crystalline than Gen-Ox and, therefore, more prone to degradation.
  • Assessment in vitro of brushing on dental surface roughness alteration by laser interferometry Dental Materials

    Azevedo, Alessandra Miranda de; Panzeri, Heitor; Prado, Célio Jesus do; De-Mello, José Daniel Biasoli; Soares, Carlos José; Fernandes-Neto, Alfredo Julio

    Abstract in English:

    Noncarious cervical lesions (NCCLs) are considered to be of multifactorial origin, normally associated with inadequate brushing. This study assessed the influence in vitro of simulated brushing on NCCL formation. Fifteen human premolars were submitted to brushing in the cementoenamel junction region, using hard-, medium- and soft-bristled brushes associated with a toothpaste of medium abrasiveness under a 200 g load, at a speed of 356 rpm for 100 minutes. The surface topography of the region was analyzed before and after brushing, by means of a laser interferometer, using "cut-off" values of 0.25 and considering roughness values in mm. The initial roughness (mm) results for dentin (D / bristle consistency: 1 - soft, 2 - medium and 3 - hard) were as follows: (D1) 1.25 ± 0.45; (D2) 1.12 ± 0.44; (D3) 1.05 ± 0.41. For enamel (E / bristle consistency: 1 - soft, 2 - medium and 3 - hard), the initial results were: (E1) 1.18 ± 0.35; (E2) 1.32 ± 0.25; (E3) 1.50 ± 0.38. After brushing, the following were the values for dentin: (D1) 2.32 ± 1.99; (D2) 3.30 ± 0.96; (D3) Over 500. For enamel, the values after brushing were: (E1) 1.37 ± 0.31; (E2) 2.15 ± 0.90; (E3) 1.22 ± 0.47. Based on the results of the ANOVA and Tukey statistical analyses (a = .05) it was concluded that soft, medium and hard brushes are not capable of abrading enamel, whereas dentin showed changes in surface roughness by the action of medium- and hard-bristled brushes.
  • Evaluation of the risk of a stripping perforation with gates-glidden drills: serial versus crown-down sequences Endodontics

    Coutinho-Filho, Tauby; De-Deus, Gustavo; Gurgel-Filho, Eduardo Diogo; Rocha-Lima, Ana Carolina; Dias, Katia Regina Cervantes; Barbosa, Carlos Augusto

    Abstract in English:

    The aim of this study was to evaluate the remaining dentine/cementum thickness using Gates-Glidden burs in serial and crown-down sequences and to observe which of the two sequences is the safest for preparing mesial roots of molars. Thirty-six left and right human mandibular first molars were selected. Standard access cavities were made and initially explored with Flexofiles sizes 10 and 15 until the tip was visible at the apex. The teeth were embedded in a muffle specially developed for this study using a PVC tube with two parallel metal rods in its lid. Each tooth-block was sectioned 3 mm apically to the furcation using a low-speed saw with a diamond disc. The tooth-block was examined under a microscope and an initial image was captured by a digital video system with 8 X and 12 X magnifications. Finally, the tooth-blocks were reassembled in the muffle so that the canals could be instrumented. After instrumentation the area of each mesial canal as well as the smallest distance to the root furcation were measured again. The mesio-buccal canals (crown-down order) and the mesio-lingual canals (serial sequence) presented an average area of 0.46 ± 0.16 mm² and 0.88 ± 0.27 mm² (P < 0.01), respectively. The mean values of the smallest distance to the furcation for the mesio-buccal and mesio-lingual canals were 0.66 ± 0.19 mm and 0.39 ± 0.13 mm (P < 0.01), respectively. The remaining dentine/cementum thickness using Gates-Glidden burs was greater in the crown-down sequence than in the serial sequence.
  • The effect of endodontic materials on the optical density of dyes used in marginal leakage studies Endodontics

    Kubo, Claudio Hideki; Valera, Marcia Carneiro; Gomes, Ana Paula Martins; Mancini, Maria Nadir Gasparoto; Camargo, Carlos Henrique Ribeiro

    Abstract in English:

    The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5%). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2% rhodamine B and the MTA-Pro Root cement presented different OD values in all 2% rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.
  • Prevalence of bruxism and emotional stress and the association between them in Brazilian police officers Epidemiology

    Carvalho, Andréa Lúcia de Almeida; Cury, Altair Antoninha Del Bel; Garcia, Renata Cunha Matheus Rodrigues

    Abstract in English:

    This study aimed to assess the prevalence of bruxism and emotional stress in Brazilian police officers, due to exposure to stressful situations, and to assess the relationship between the type of work done by a police officer and the presence of bruxism and emotional stress. A cross-sectional study was conducted at the Military Police of the State of São Paulo, Campinas, SP, Brazil. The final sample included 394 male police officers (mean age = 35.5 years). Bruxism was diagnosed by the presence of aligned dental wear facets associated with the presence of one of the following signs or symptoms: self-report of tooth-grinding, painful sensitivity of the masseter and temporal muscles, discomfort in the jaw musculature upon waking. The Stress Symptoms Inventory (SSI) was applied to evaluate emotional stress. The type of work done by the police was classified as organizational or operational, the latter being assumed as the more stressful since it exposes the police officer to life risk. The results showed a prevalence of bruxism of 50.2% and a prevalence of emotional stress of 45.7%. The Chi-square test indicated an association between stress and bruxism (P < .05). No significant association was found between emotional stress and type of work (P = .382) or between bruxism and work activity (P = .611). It could be concluded that emotional stress was associated with bruxism, independently of the type of work done by police officers.
  • Relationship between oral health and its impact on quality of life among adolescents Epidemiology

    Biazevic, Maria Gabriela Haye; Rissotto, Renata Regina; Michel-Crosato, Edgard; Mendes, Leila Amorim; Mendes, Maria Odete Amorim

    Abstract in English:

    The aim of this study was to assess oral health status and its relationship with quality of life. A household population, cross-sectional study was carried out; participants were between 15 and 17 years of age (n = 247) and were examined by two calibrated dentists. Socio-economic status was classified according to ANEP-ABIPEME criteria. Clinical examinations to observe DMFT, CPI and Dean indices were performed as per WHO criteria. The Significant Caries Index (SiC) was used to evaluate polarization of the occurrence of caries among participants of the tercile with higher DMF-T. The OHIP instrument was used to measure quality of life. The Spearman and Mann-Whitney tests were used for assessing correlations (5% significance level). Examinations were carried out in 117 (47.37%) females and in 130 (52.63%) males. Of the examined participants, 45.75% were classified as belonging to socio-economic class C. Caries occurrence was observed in 218 subjects (88.26%); the mean DMFT was 5.40. The SiC index was 9.97. Almost half (47.77%) of the participants examined did not present sextants affected by periodontal disease. Of the participants examined, 80.16% presented absence of fluorosis. The mean OHIP was 3.95. The following correlations were observed: a positive and statistically significant correlation between the highest score in the OHIP and decayed teeth; a positive correlation with threshold significance between OHIP and DMFT; an inverse correlation between intact teeth and OHIP; and a positive and non statistically significant correlation between SiC and OHIP (correlation coefficient = 0.13, p = 0.245). Association between the mean OHIP and the terciles was not significant (p = 0.146); there were also no associations between periodontal condition and OHIP nor were there associations between the presence of fluorosis and mean OHIP.
  • In vivo qualitative analysis of the biocompatibility of different cyanoacrylate-based adhesives Oral Pathology

    Moretti Neto, Rafael Tobias; Mello, Isabel; Moretti, Ana Beatriz da Silveira; Robazza, Carlos Roberto Colombo; Pereira, Alessandro Antônio Costa

    Abstract in English:

    Cyanocrylates have been widely used in the medical and dental fields for several years. In Dentistry, cyanoacrylates have been used for suturing, pulp capping, as retrofilling material in endodontic surgeries, and as cervical plug for pulpless teeth bleaching. The biocompatibility of these adhesives has been the topic of many researches and subcutaneous implantation is an effective methodology for these studies. The present study evaluated the biocompatibility of three different cyanoacrylate-based adhesives. Thirty-six Wistar rats were used, divided into four groups of 9 animals each: A (control) - distilled water, B - cyanoacrylate ester (Super Bonder), C - n-butyl-cyanoacrylate (Histoacryl) and D - alpha-cyanoacrylate (Three Bond). The materials were dispensed in sponges of polyvinyl chloride, the animals were incised and the sponges were inserted in the subcutaneous tissue and sutured. Each group was sub-divided according to the time of sacrifice of the animals: 7, 21 and 45 days. Subjective analysis of the histologic material showed that all groups presented some degree of irritability, but the inflammatory reaction decreased with the experimental time in all groups. Group D showed an inflammatory reaction which was closer to that of the control group and was considered to have good biocompatibility. Groups B and C were similar and presented more aggressive inflammatory reactions when compared to the control group. Based on the results, it was concluded that alpha-cyanoacrylate (Three Bond) was the most biocompatible adhesive because it caused the lowest levels of inflammation.
  • Facial dimensions, bite force and masticatory muscle thickness in preschool children with functional posterior crossbite Orthodontics

    Castelo, Paula Midori; Bonjardim, Leonardo Rigoldi; Pereira, Luciano José; Gavião, Maria Beatriz Duarte

    Abstract in English:

    Posterior crossbite may affect craniofacial growth and development. Thus, this study aimed to associate facial dimensions (by standardized frontal photographs) to masseter and anterior portion of the temporal muscle thickness (by ultrasonography) and maximal bilateral bite force in 49 children with deciduous and early mixed dentitions. They were distributed in four groups: deciduous-normal occlusion (DNO, n = 15), deciduous-crossbite (DCB, n = 10), mixed-normal occlusion (MNO, n = 13) and mixed-crossbite (MCB, n = 11). Anterior facial height (AFH), bizygomatic width (FWB), and intergonial width (FWI) were determined and associated with muscle thickness and bite force, applying Pearson’s coefficients and multiple logistic regression, with age, gender, body weight and height as the covariates. FWB and FWI were correlated positively with the masseter thickness, whereas AFH/FWB and AFH/FWI ratios had negative correlation, except in the DNO group. The correlation between AFH/FWB and bite force in the MCB group was significantly negative. A higher AFH/FWB in MNO and MCB led to a significantly higher probability for functional crossbite development. In the studied sample, it was observed that children in the early mixed dentition with a long-face trend showed lower bite force and higher probability to present functional posterior crossbite, without significant influence of the covariates.
  • Streptococcus mutans counts in plaque adjacent to orthodontic brackets bonded with resin-modified glass ionomer cement or resin-based composite Orthodontics

    Mota, Solange Machado; Enoki, Carla; Ito, Izabel Yoko; Elias, Ana Maria; Matsumoto, Mírian Aiko Nakane

    Abstract in English:

    This study investigated the number of Streptococcus mutans CFU (colony forming units) in the saliva and plaque adjacent to orthodontic brackets bonded with a glass ionomer cement - GIC (Fuji Ortho) or a resin-based composite - RC (Concise). Twenty male and female patients, aged 12 to 20 years, participated in the study. Saliva was collected before and after placement of appliances. Plaque was collected from areas adjacent to brackets and saliva was again collected on the 15th, 30th, and 45th day after placement. On the 30th day, 0.4% stannous fluoride gel was applied for 4 minutes. No significant modification in the number of Streptococcus mutans CFU in saliva was observed after placement of the fixed orthodontic appliances. On the 15th day, the percentage of Streptococcus mutans CFU in plaque was statistically lower in sites adjacent to GIC-bonded brackets (mean = 0.365) than in those adjacent to RC-bonded brackets (mean = 0.935). No evidence was found of a contribution of GIC to the reduction of CFU in plaque after the 15th day. Topical application of stannous fluoride gel on the 30th day reduced the number of CFU in saliva, but not in plaque. This study suggests that the antimicrobial activity of GIC occurs only in the initial phase and is not responsible for a long-term anticariogenic property.
  • Evaluation of mandibular range of motion in Brazilian children and its correlation to age, height, weight, and gender Pediatric Dentistry

    Sousa, Letícia Mêlo de; Nagamine, Harumi Martins; Chaves, Thaís Cristina; Grossi, Débora Bevilaqua; Regalo, Simone Cecílio Hallak; Oliveira, Anamaria Siriani de

    Abstract in English:

    This study aimed to measure the active mandibular range of motion (ROM) (mouth opening: MO; right and left lateral movements: RL and LL; protrusion: P) in Brazilian children of both genders and of various ages, weights, and heights, and to establish correlations among such variables. Study subjects (n = 303) were healthy boys and girls, with ages ranging between 6 and 14 years, who were regular students of a public school in the state of São Paulo. Analysis of variance and intra-class correlation coefficients were considered significant for p < 0.05. Weak significant correlations were observed between mandibular ROM and age, height, and weight. No statistically significant differences (p > 0.05) were observed regarding mandibular ROM between gender groups. Mean mandibular ROM values showed significant increases (p < 0.05) in relation to age, height, and weight, except for RL (p > 0.05), in the studied age range. Significantly smaller (p < 0.05) mean mandibular ROM values were observed for the intervals of 6 and 7 years of age, 1.15-1.35 m, and 17.30-26.50 kg, in relation to the other ranges. Nonetheless, no differences were observed among mean mandibular ROM values in the ranges 8 to 12-14 years, 1.36-1.75 m, and 47-85 kg. Thus, it is suggested that weight, height, and age variables be considered when obtaining mandibular ROM values, particularly in children aged 6 to 7 years, measuring 1.15-1.35 m, and weighing between 17.3-46.5 kg.
  • The influence of residual salivary fluoride from dentifrice on enamel erosion: an in situ study Pediatric Dentistry

    Magalhães, Ana Carolina; Rios, Daniela; Martinhon, Cleide Cristina Rodrigues; Delbem, Alberto Carlos Botazzo; Buzalaf, Marília Afonso Rabelo; Machado, Maria Aparecida de Andrade Moreira

    Abstract in English:

    The objective of this study was to assess the salivary residual effect of fluoride dentifrice on human enamel subjected to an erosive challenge. This crossover in situ study was performed in two phases (A and B), involving ten volunteers. In each phase, they wore acrylic palatal appliances, each containing 3 human enamel blocks, during 7 days. The blocks were subjected to erosion by immersion of the appliances in a cola drink for 5 minutes, 4 times a day. Dentifrice was used to brush the volunteers’ teeth, 4 times a day, during 1 minute, before the appliance was replaced into the mouth. In phases A and B the dentifrices used had the same formulation, except for the absence (PD) or presence (FD) of fluoride, respectively. Enamel alterations were determined using profilometry, microhardness (%SMHC), acid- and alkali-soluble F analysis. The data were tested using ANOVA (p < 0.05). The concentrations (mean ± SD) of alkali- and acid-soluble F (µgF/cm²) were, respectively, PD: 1.27ª ± 0.70/2.24A ± 0.36 and FD: 1.49ª ± 0.44/2.24A ± 0.67 (p > 0.05). The mean wear values (± SD, µm) were PD: 3.63ª ± 1.54 and FD: 3.54ª ± 0.90 (p > 0.05). The mean %SMHC values (± SD) were PD: 89.63ª ± 4.73 and FD: 87.28ª ± 4.01 (p > 0.05). Thus, we concluded that the residual fluoride from the fluoride-containing dentifrice did not protect enamel against erosion.
  • Periodontal condition in patients with rheumatoid arthritis Periodontics

    Ishi, Eduardo de Paula; Bertolo, Manoel Barros; Rossa Jr., Carlos; Kirkwood, Keith Lough; Onofre, Mirian Aparecida

    Abstract in English:

    The purpose of this clinical study was to investigate if periodontal disease and rheumatoid arthritis (RA) are associated. The study included 39 RA patients (test group) and 22 age- and gender-matched healthy individuals (control group). Questionnaires on general and oral health were applied and a complete periodontal exam, including visible plaque, marginal bleeding, attachment loss (AL) and number of teeth present, was also performed by a single calibrated examiner. Diabetes mellitus patients and smokers were excluded. RA patients had fewer teeth, higher prevalence of sites presenting dental plaque and a higher frequency of sites with advanced attachment loss. Although the prevalence of dental plaque was higher in the test group (Chi-square test, p = 0.0006), the percentage of sites showing gingival bleeding was not different (Fisher’s exact test, p > 0.05). Based on our results, we suggest that there is an association between periodontal disease and RA.
  • Image quality in partially erased DenOptix® storage phosphor plates Radiology

    Lopes, Sérgio Lúcio Pereira de Castro; Cruz, Adriana Dibo da; Ferreira, Rívea Inês; Bóscolo, Frab Norberto; Almeida, Solange Maria de

    Abstract in English:

    This study aimed at investigating the effect of the partial erasing of DenOptix® system storage phosphor plates on the image quality of digital radiographs. Standardized digital radiographs were acquired of a phantom mandible, using size 2 intraoral DenOptix® storage phosphor plates (n = 10). Subsequently, the active areas of the plates were placed in a viewing box with a constant light intensity of 1,700 lux for 130 seconds to achieve complete erasing (control plate), as well as for 0, 5, 10, 15, 20, 25, 34, 66, and 98 seconds, to compose the experimental group of partially erased plates. The same exposure settings were repeated using the control and experimental plates, which were scanned at a resolution of 300 dpi. Five radiologists independently examined the pairs of digital radiographs obtained with the control and partially erased plates, in random order, and indicated the best image for oral diagnosis. Cochran-Mantel-Haenszel’s chi-square test, at a significance level of 5%, was used to compare the percentages of superior quality images in each combination of control and partially erased plates, subjectively assessed. No significant differences were found between radiographic images acquired with control and partially erased plates, except for the combination of 0 second (30%) versus 130 seconds (70%), p = 0.0047. It can be concluded that, under adequate light intensity conditions, erasing intraoral DenOptix® storage phosphor plates may require time intervals of as little as 5 seconds.
  • Flexural and diametral tensile strength of composite resins Restorative Dentistry

    Della Bona, Álvaro; Benetti, Paula; Borba, Márcia; Cecchetti, Dileta

    Abstract in English:

    This study evaluated the flexural strength (sf) and the diametral tensile strength (st) of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk), following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm) specimens (n = 10) were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10) were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000) recording the fracture load (N). Strength values (MPa) were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05). The mean and standard deviation values (MPa) were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05), which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined.
  • Spectrophotometric assessment of the effects of 10% carbamide peroxide on enamel translucency Restorative Dentistry

    Vieira, Glauco Fioranelli; Arakaki, Yuri; Caneppele, Taciana Marco Ferraz

    Abstract in English:

    Tooth shade results from the interaction between enamel color, enamel translucency and dentine color. A change in any of these parameters will change a tooth’s color. The objective of this study was to evaluate the changes occurring in enamel translucency during a tooth whitening process. Fourteen human tooth enamel fragments, with a mean thickness of 0.96 mm (± 0.3 mm), were subjected to a bleaching agent (10% carbamide peroxide) 8 hours per day for 28 days. The enamel fragment translucency was measured by a computer controlled spectrophotometer before and after the bleaching agent applications in accordance with ANSI Z80.3-1986 - American National Standard for Ophthalmics - nonprescription sunglasses and fashion eyewear-requirements. The measurements were statistically compared by the Mann-Whitney non-parametric test. A decrease was observed in the translucency of all specimens and, consequently, there was a decrease in transmittance values for all samples. It was observed that the bleaching procedure significantly changes the enamel translucency, making it more opaque.
Sociedade Brasileira de Pesquisa Odontológica - SBPqO Av. Prof. Lineu Prestes, 2227, 05508-000 São Paulo SP - Brazil, Tel. (55 11) 3044-2393/(55 11) 9-7557-1244 - São Paulo - SP - Brazil
E-mail: office.bor@ingroup.srv.br