Abstract
This study describes a method for the simultaneous parabens (PBs) quantification in 100 urine volunteers residing in Southern Brazil, using a three-step solid-phase extraction (SPE) with hydrophilic-lipophilic balance (HLB®) sorbent, with subsequent analysis by liquid chromatography-tandem mass spectrometry (LC/MS-MS). This validated approach simplifies the standard five-step SPE process by eliminating the conditioning and equilibration steps. Target analytes included methylparaben (MeP), ethylparaben (EtP), propylparaben (PrP) and butylparaben (BuP). Urine samples (1 mL) were hydrolyzed with β-glucuronidase acid solution, mixed with deuterated internal standards, and subjected to SPE. Analysis was performed using an UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm), with a 6.5-min chromatographic run. Intra-assay precision was 2.8-11.6%, inter-assay precision was 0.7-7.1%, and accuracy was 94.8-111.8%. Extraction yields varied from 92.31-109.4%, with matrix effects ranging from -13.7 to -2.8. PBs were measured in all urine samples. A concerning proportion of 3% of the individuals exceeded the recommended acceptable daily intake (ADI) for PrP, indicating a potential health risk (hazard quotient ≥ 1.0). These findings provide valuable insights into human exposure to PBs in Southern Brazil, highlighting the need for further research to assess potential health risks.
Keywords:
parabens; SPE; urine; hair; biomonitoring; human exposure; HLB®; risk assessment; LC-MS/MS
Introduction
Parabens (PBs), alkyl esters of 4-hydroxybenzoic acid, are widely used as antimicrobial preservatives in cosmetics, sunscreens, food products, and pharmaceutical preparations.1 Human exposure to PBs primarily occurs through dermal absorption, ingestion, and inhalation.2 The most common PBs with a linear alkyl chain as the substituent are methylparaben (MeP), ethylparaben (EtP), propylparaben (PrP), and butylparaben (BuP).3 Public concern regarding PBs exposure has increased as studies have linked these compounds to various endocrine-related diseases, including reproductive disorders, hormone-dependent cancers, obesity, diabetes, and neurodevelopmental disorders.4,5 PBs have also been shown to negatively affect sperm quality6 and fertility.7 The estrogenic potential of PBs generally increases with alkyl chain length, though dermal absorption tends to decrease as the chain lengthens.2
In Europe, only MeP and EtP are permitted as preservatives in food.8 For cosmetic products, MeP and EtP are allowed up to a concentration of 0.4%, or up to 0.8% in mixtures, while PrP and BuP are permitted up to 0.14% each.9 In the United States, the Food and Drug Administration (FDA) requires does not impose specific quantitative limits on most ingredients, such as PBs, in cosmetics and food products.10 In Brazil, MeP, EtP, PrP, BuP, hexamidine diparaben (HexDip) and hexamidine paraben (HexP) are permitted as preservatives in cosmetics and personal care products, with individual limits of 0.14% and a combined limit of 0.8%.11 However, PrP is prohibited in Brazilian food products.11
Exposure to PBs is widespread, and numerous biomonitoring studies have been conducted worldwide.12-22 In Brazil, just a few studies have been performed.23-27 PB biomonitoring studies typically use urine samples, which enable the calculation of estimated daily intakes (EDI) and allow comparison with established safety thresholds.13,15,22,28 This approach provides valuable data on exposure levels and potential health risks for populations exposed to these chemicals.21,28-31 Urine, being a non-invasive biological matrix that is readily available in large quantities and reflects recent exposure is particularly suitable for PB biomonitoring studies.7,19,32,33 This is especially relevant given that PB metabolites are often present in urine at higher concentrations and for longer durations than blood samples.34 On the other hand, hair testing for PBs has also been explored in a few studies.16,35-39 Hair testing offers a valuable complement to urine analysis, providing several advantages. Notably, hair analysis allows for a longer temporal window of exposure assessment (weeks to months) and involves different mechanisms of biomarker incorporation, enabling the assessment of chronic exposure.40 However, the nature and quality of information obtained from each matrix (hair and urine) can differ significantly due to their unique characteristics.41
Sample preparation of urine for PB quantification requires effective clean-up and concentration to achieve the necessary selectivity and sensitivity in liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods.32,42 Solid-phase extraction (SPE) is commonly used for this purpose, particularly with hydrophilic-lipophilic balance (HLB®) sorbents.43 The standard SPE procedure typically includes five stages: conditioning, equilibration, sample loading, washing, and elution.44 Recently, an SPE procedure using HLB® sorbent for multianalyte determination in human plasma was reported, in which the conditioning and equilibration steps were omitted.45 Omitting these steps results in a faster procedure and reduced solvent consumption, which is especially advantageous in biomonitoring studies that often require processing a large number of samples. Notably, to date, there is no description of a simplified, three-step SPE procedure specifically for the determination of PBs in urine.
In this study, we aimed to develop and validate an innovative analytical method for the simultaneous determination of MeP, EtP, PrP, and BuP in urine. The method employs a simplified, three-step SPE procedure using HLB® sorbent, followed by LC-MS/MS analysis. Additionally, the validated method was applied to biomonitoring and risk assessment in a Brazilian cohort of volunteers, also allowing the comparison of urine and hair levels of PBs to better understand the frequency of detection, variability, and chronicity due to their product consumption.
Experimental
Chemical, reagents and solutions
Reference samples of EtP and BuP were supplied by Chem Service (West Chester, USA), while reference samples of MeP and PrP were purchased from Sigma-Aldrich (St. Louis, USA). The isotope-labeled internal standards (IS) MeP-d4, EtP-d4, PrP-d4, and BuP-d9 were obtained from Toronto Research Chemicals (North York, Canada). Acetic acid, acetone, acetonitrile, ammonium formate, β-glucuronidase (≥ 100,000 units mL-1) from Helix pomatia, dansyl chloride, methanol, sodium acetate, sodium bicarbonate, sodium dodecyl sulfate (SDS), sodium hydroxide, and formic acid were also purchased from Sigma-Aldrich. Ethyl acetate was supplied by Honeywell (Morris Plains, USA), and activated charcoal was obtained from Dinâmica Química (Indaiatuba, Brazil). Oasis HLB® (60 mg, 3 mL) SPE cartridges were sourced from Waters Technologies (Milford, USA). Ultra-pure deionized water was supplied by a Milli-Q Reference system from Millipore (Billerica, MA, USA). Syringe filters with polytetrafluoroethylene (PTFE) membranes (0.22 µm) were purchased from Nova Analítica (São Paulo, Brazil). Reagents, calibrators, and quality control samples (QC) for the determination of creatinine was purchased from Bioclin (Belo Horizonte, Brazil).
Stock solutions of the target compounds were prepared at 1 mg mL-1 by dissolving the powders in methanol. Stock solutions of the IS were prepared at 100 μg mL-1 in methanol. Both analyte and IS stock solutions were stored at -20 °C. Methanolic working solutions of the analytes were prepared at concentrations of 40; 120; 200; 400; 1,000; 2,000; 4,000; 6,000; 8,000; 12,000, and 16,000 ng mL-1. The methanolic working solution of the IS contained the isotopically labelled internal standards at a concentration of 100 μg mL-1. The working IS solution contained MeP-d4, EtP-d4, PrP-d4, and BuP-d9 at 200 ng mL-1 all dissolved in methanol. Calibration and QC samples were obtained by diluting the analyte working solution with blank urine (1:20, v v-1).
A sodium acetate buffer (1 M, pH 4.5) was prepared by dissolving 0.82 g of sodium acetate in 10 mL of ultrapure water, and the pH was adjusted to 4.5 with acetic acid. The sodium bicarbonate buffer (10 mM, pH 10.5) was prepared by dissolving 0.42 g of sodium bicarbonate in 50 mL of ultrapure water, and the pH was adjusted to 10.5 using a 1 M aqueous solution of sodium hydroxide. A solution of SDS 0.1% (m v-1) was prepared in ultrapure water. An acetic acid solution 1.5% (v v-1) was prepared extemporaneously by adding 1 mL of acetic acid to 9 mL of ultrapure water, followed by transferring 6 mL of this diluted solution to another flask and completing the volume to 34 mL with ultrapure water. Mobile phase A consisted of ultrapure water, and mobile phase B consisted of methanol. The SPE washing mixture was prepared by mixing ultrapure water and acetic acid in a 99.5:0.5 (v v-1) ratio. The SPE wash solution was prepared by diluting 50 µL of acetic acid to 10 mL with ultrapure water.
Blank urine preparation and sample storage
Blank urine samples used for method validation were treated with activated charcoal to remove baseline PB concentrations.46 The cleaning process involved transferring the urine into polypropylene tubes containing activated charcoal (60 mg mL-1), homogenizing the mixture for one hour, and then centrifuging at 14,000 rpm for 5 min. The supernatant was collected into a separate tube. This process was repeated three times. The treated blank urine samples were stored in polypropylene tubes and frozen at −80 ºC.
Sample preparation
Urine samples were subjected to enzymatic hydrolysis to measure total PB concentrations. Aliquots of 1 mL of urine were mixed with 10 μL of β-glucuronidase solution, 300 μL of 1 M sodium acetate buffer (pH 4.5), and 25 μL of the working IS followed by vortex-mixing for 1 min. The samples were incubated at 37 ºC for 12 h. Subsequently, the samples were acidified with 200 μL of formic acid, centrifuged for 5 min at 3,000 rpm, and loaded onto an OASIS HLB® SPE cartridge (60 mg 3 mL-1). The cartridge was then washed with 1 mL of 0.5% acetic acid and vacuum-dried for 5 min. Elution was performed twice with 1 mL of acetonitrile. After washing, the eluates were dried using a vacuum centrifuge at 60 ºC. Dried extracts were reconstituted with 150 μL of a 90:10 (v v-1) water-methanol mixture. Finally, the reconstituted extracts were centrifuged (12,200 rpm, 10 min) and filtered using a PTFE syringe filter. Aliquots of 5 µL were injected into the LC-MS/MS system. Urinary creatinine concentration was measured using a modified Jaffé method in an open-channel automatic chemical analyzer Bioclin 2000 Premium (Mindray, China).47
LC-MS/MS analysis
The analyses were performed using an Acquity UPLC I-Class chromatography system coupled with a Xevo TQ-S micro triple quadrupole mass spectrometer, both from Waters (Milford, USA). Chromatographic separation was achieved using an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm), also supplied by Waters, maintained at 45 °C. The autosampler temperature was set to 10 °C. A constant flow rate of 0.4 mL min-1 was applied with the following gradient: the initial condition was 95% mobile phase A, which decreased linearly to 5% over 2.2 min, holding until 3.5 min. The gradient then returned to the initial condition at 3.51 min. The total run time was 6.5 min. The electrospray ionization source was operated in negative ionization mode, with a capillary voltage of 3 kV. The desolvation temperature and gas flow was set to 500 °C and 1000 L h-1, respectively. Dwell time was 0.02 s. The source temperature was set to 150 °C. Compound-specific acquisition parameters are presented in Table 1.
Method validation
The method was validated following the bioanalytical method validation guidelines of the Food and Drug Administration.48
Selectivity
Blank urine samples from six different volunteers were processed following the extraction protocol above to check for the presence of chromatographic peaks that could interfere with the detection of analytes. An interference was considered present if a peak area ratio greater than 20% of the peak area ratio observed at the lower limit of quantification (LLOQ) was found at the retention time of any of the analytes.48
Linearity
Linearity was evaluated by analyzing calibration samples at concentrations of 2, 10, 20, 50, 100, 200, 400, and 800 ng mL-1 for all target analytes, processed over five different days. Calibration curves were established by correlating the nominal concentration of each calibrator with the corresponding peak area ratio of the target compound to the correspondent IS. Linear regression was applied for all compounds, using a weighting factor of 1/x2. The calibration curves were considered acceptable if the correlation coefficients (r) exceeded 0.99 and the back-calculated concentrations of the calibrators were within ± 15% of their nominal values.48
Precision and accuracy
Precision and accuracy were evaluated by measuring concentrations of QC samples at low (QCL), medium (QCM), and high (QCH) concentrations. QCL, QCM, and QCH samples had concentrations of 6, 35, and 150 ng mL-1, respectively, for all compounds. The QC samples were analyzed in quintuplicate on three separate days. Within- and between-assay precision were calculated using analysis of variance (ANOVA) and expressed as the percent coefficient of variation (CV, ion percentage). The acceptance criteria for precision were CV within ± 15%. Accuracy was defined as the percentage of the nominal concentration represented by the concentration obtained from the calibration curve. Mean values within ±15% of the theoretical value were considered acceptable.48
Lower limit of quantification
The lower limit of quantification (LLOQ) was determined by analyzing a quality to better understand the frequency of detection, variability, and chronicity due to their product consumption and thawed at room temperature before analysis. Area ratios were obtained after triplicate analysis of each QC level following each cycle and were compared to those obtained from fresh samples. The maximum acceptable variation from the fresh samples was ± 15%.48
Matrix effect and extraction yield
Matrix effect (ME) and extraction yield (EY) were estimated by a post-extraction spike method, based on the analysis of three series (A, B, and C) of QC samples (QCL and QCH).49 The tests were carried out in triplicate, using blank urine samples from six different volunteers. The A series was comprised of analyte solutions and IS in the mobile phase at concentrations equivalent to 100% EY. The B series was made up of blank extracts, reconstituted with the solution of the A series. The set C were QCL and QCH samples, processed as described above. ME was calculated as the percentage of reduction or increase of the peak area ratios of the analytes in post-extraction enriched controls (B) compared to solutions (A), which is expressed as ME (%) = [100 − (B/A)]. The EY was calculated by comparing the peak areas of samples from sets C and B using the formula EY = C/B.49
Dilution integrity
Dilution integrity was assessed by extracting urine samples containing the analytes at a concentration of 30000 ng mL-1 in triplicate, which were then diluted 50 times with blank urine. This diluted quality QC sample had a target concentration of 600 ng mL-1. Accuracy and precision of this diluted QC were calculated after quintuplicate analysis over three different days, as described above, using the same acceptance criteria.48
Determination of PBs in hair
Hair samples were washed sequentially with ultrapure water, aqueous SDS solution (0.1%, m/v), and ultrapure water, each for 5 min in an ultrasonic bath. Another wash was performed by incubating the hair sample with a mixture of dichloromethane/methanol (1:1, v/v) in an ultrasonic bath for 30 min, with supernatants discarded after centrifugation (15000 rpm, 5 min). This procedure was repeated three times. Afterward, the washed sample was dried at room temperature and cut into small pieces (2-3 mm) with stainless steel scissors. An aliquot of 50 mg of the hair sample was incubated with 1 mL of 1.5% acetic acid at 38 °C for 12 h. After acidic hydrolysis, the hair samples were cooled to room temperature and centrifuged at 15,000 rpm for 5 min. Then, 800 µL of the supernatant were mixed with the IS solution of deuterated analogues and two liquid-liquid extraction cycles were performed with 1 mL of ethyl acetate. The organic extracts were evaporated to dryness, and 50 µL of 100 mM sodium bicarbonate buffer and 50 µL of dansyl chloride in acetone (1 mg mL-1) were added to the dry residues for derivatization. Aliquots of 10 µL were injected into the same LC-MS/MS system used for the analysis of urine samples. Chromatographic separation employed an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) from Waters. The column was maintained at 40 °C, and the samples were kept at 10 °C. The mobile phase flow rate was 350 µL min-1. Two mobile phases were used for the analysis: the first (A) was ultra-purified water with 0.1% formic acid, and the second (B) was methanol with 0.1% formic acid. The initial gradient was 10% of phase B, increasing to 95% in 1.9 min, holding at 95% until 3.6 min, and then returning to the initial condition at 3.7 min. The total run time was 5.5 min. The electrospray ionization source was operated in positive ionization mode, with a capillary voltage of 3.0 kV. The desolvation temperature and gas flow were set to 500 °C and 1000 L h-1, respectively. The source temperature was set to 150 °C. Dwell time was 0.02 s. Compound-specific acquisition parameters are presented in Table 2. The assay fulfilled validation guidelines acceptance criteria, with a linear range of 2 to 10000 ng g-1, precision of 1.60 to 9.09% (intra-day) and 1.68 to 8.75% (inter-day), accuracy of 100.71 to 108.58%, and matrix effects of −9.43 to 9.62%. Over the curve dilution was evaluated using 10 mg hair samples with QCH concentration, with precision of 3.58 to 6.25% (intra-day) and 6.36 to 8.81% (inter-day), and accuracy of 102.13 to 107.26 %. Samples with concentration higher than the upper limit of quantification (ULOQ) were reanalyzed using 10 mg of hair and results were multiplied by 5.
Retention times (tR) and mass spectrometric acquisition parameters of the target compounds as dansyl derivatives as employed in the hair analysis
Volunteer sample and data collection
Urine samples were collected from 100 healthy adult volunteers (96 females and 4 males), aged 17-57, living in Brazilian cities from the State of Rio Grande do Sul (Novo Hamburgo and São Leopoldo, which are typical medium-sized cities, and Porto Alegre), from September 2023 to May 2024. Urine samples were collected randomly during the daytime into 50 mL polypropylene (PP) tubes and then transported to the laboratory for PBs quantification. Volunteers also provided hair samples within 30 min of urine collection. Hair was cut from the posterior vertex as close to the scalp as possible. Only the first proximal centimeter was subsequently analyzed to represent exposure in the month prior to sampling. Collected hair was wrapped in aluminum foil and stored at room temperature until analysis. Urine samples were stored at -80 °C in darkness until analysis. In addition to providing samples, volunteers completed a questionnaire that included questions about sex, age, height, weight, diet (regular or healthy), skin color, hair color, and profession as supplementary data. The frequency of cosmetic use was also recorded. The urine samples collected were not discriminated against in selecting individuals, ensuring data preservation, confidentiality, and anonymity. The project was approved by the institutional review board of Universidade Feevale (number 6.024.337). All participants provided written consent to participate in the study.
Estimated daily intake (EDI) and hazard quotient calculation
The EDI was calculated using equation 1, based on the measured concentrations (C) of PBs13,50 and was subsequently compared with the exposure limits established by the Joint FAO/WHO Expert Committee on Food Additives (JECFA)51 and the European Food Safety Authority (EFSA).52 For the EDI calculation, a daily urinary output (Vurine) of 1.60 L was assumed.53 The fraction of each PB excreted in urine (Fue) was used in these calculations, with values of 0.17, 0.14, 0.10, and 0.06 for MeP, EtP, PrP, and BuP, respectively.33,54 Individual body weight was also considered. Hazard quotient (HQ) values were then estimated by dividing the EDI by the tolerable daily intake (TDI) of the compound, as shown in equation 2.13 These authorities established a TDI of 10,000 μg kg-1 day-1 for combined exposure to MeP and EtP,9 based on no-observed-adverse-effect levels (NOAELs) of 1,000,000 μg kg-1 day-1 for each compound, as identified in long-term toxicity studies and evaluations of sex hormone levels and male reproductive organs in juvenile rats.6,9,55 For the PBs with no official health-based threshold value, we used a conservative NOEL of 20 μg kg-1 day-1, derived for PrP and BuP based upon a NOAEL of 2 mg kg-1 day-1 with an uncertainty factor of 100.9
where, EDI is estimated daily intakes, Fue is the fraction of each PB excreted in urine; V is the volume, TDI is tolerable daily intake and HQ is hazard quotient.To assess the HQ, the risk classification criteria were applied as previously described.55 According to these criteria, an HQ ≤ 0.01 indicates an insignificant risk, where adverse effects are unlikely; an HQ between 0.01 and 0.10 suggests minimal risk; an HQ from 0.10 to 1.0 indicates medium risk; and an HQ ≥ 1.0 signifies high risk.9,52,56
To evaluate the potential cumulative effects resulting from simultaneous exposure to multiple PBs, a cumulative risk assessment was conducted using the hazard index (HI) approach, where the HI is calculated as the sum of the individual HQs for each compound (equation 3). If HI ≥ 1.0, is a potential cumulative health risk and further investigation is needed; and HQ ≤ 1 indicates no significant cumulative risk.33,57,58
The hazard index (HI) is the sum of the risk quotients of each PB (∑HQs).
Statistical analysis
Statistical analyses were performed with SPSS (SPSS Statistics V29.0) (Chicago, USA) with p-values < 0.05 considered significant. A descriptive analysis of all the variables was performed. Absolute frequencies and percentages described qualitative variables. The Kolmogorov-Smirnov test was performed to determine the normality of quantitative data. Quantitative variables were summarized by their median, percentiles and range. The Kruskal-Wallis or Mann-Whitney tests were used to compare PBs concentrations in urine, daily intake, HQ and age across different cosmetic exposure frequency and hair colors. The Spearman correlation test was employed to explore correlations between PBs levels in urine and hair. Categorical variables were associated by the Chi-square test.
Results and Discussion
Sample preparation and analytical conditions
SPE is commonly used to extract low-concentration PBs from human urine, increasing detectability and matrix effects. Offline SPE or online SPE techniques are normally used for the extraction of PBs from urine samples.32,42 Usually, the extraction of these compounds used to be achieved using non-polar retention mechanism.32 Table 3 provides an overview of SPE-LC-MS/MS methods for this determination, based on publications available in the PubMed, Scopus and SciELO database from the year 2005 to 2024. Studies providing detailed methodological information on SPE extraction from urine and analyzing the same PBs were selected. A simultaneous search for “paraben,” “urine,” “liquid chromatography,” and “SPE” yielded 12 publications. After excluding irrelevant studies, we retained six publications for evaluation. Reported sample volumes ranged from 0.1 to 4 mL. A key challenge in developing and validating an assay for PBs in human urine is their ubiquitous presence. Most of the studies summarized in Table 3 used synthetic urine as a blank for preparing calibration and QC samples. While convenient, synthetic urine does not capture the complexity of human urine. In this study, we repeatedly treated volunteer urine samples with activated charcoal to obtain a blank matrix, yielding no measurable PB peaks with our method. Before SPE extraction, samples underwent enzymatic hydrolysis to enable determination of the total urinary PB content, encompassing both free and conjugated species. Enzymatic hydrolysis with β-glucuronidase from Helix pomatia was used to deconjugate phase II metabolites, specifically glucuronide conjugates, thus allowing the measurement of total PB concentrations in urine.18,63 A hydrolysis time of 12 h at 37 °C yielded higher PB peak areas compared to the longer hydrolysis times reported in previous studies taking until 16 h.12,62 Hydrolyzed urine samples were acidified to halt glucuronidase activity and to enhance PB retention on the SPE sorbent through reversed-phase mechanisms.
SPE-LC-MS/MS based methods and their corresponding sample preparation protocol for the determination of PBs in human urine
HLB® sorbents have been previously used for PB extraction from urine. These reported methods followed the usual SPE protocol, including conditioning, equilibration, sample application, washing, and elution steps.43 Recently, the use of SPE with HLB® sorbent without the conditioning and equilibration steps was reported for the determination of multiple drugs in plasma, resulting in a faster procedure and reduced solvent consumption.45 In this study, we describe the first application of a simplified, three-step SPE procedure for extracting PBs from human urine using an HLB® sorbent. This streamlined approach resulted in a faster procedure and reduced solvent consumption. Specifically, we used only 2 mL of acetonitrile per extraction, which is significantly less than the 4 to 20 mL used in other studies summarized in Table 3. The developed sample preparation method was optimized to reduce the use of toxic solvents, minimize waste and environmental impact, limit human exposure, and preserve analytical performance without the need for derivatization.64,65 Notably, the simplified procedure utilized a low sample volume (1 mL) and achieved high EY ranging from 92.31 to 109.4%, with minimal ME (−13.7-2.8%), as shown in Table 4. In contrast, it was reported significant ME, with a 50% signal suppression for most compounds62 and studies that used the same amount of urine as our study had lower EY (63-109%) and ME (−8-33%).60 A small injection volume of 5 μL was used on the LC-MS/MS system, consistent with other studies (5-10 μL)61,62,66 and lower than others (20 μL).32
General method validation parameters for PBs determination: precision, accuracy, EY, ME and stability
The analytical run time was 6.5 min per sample, significantly faster than in other studies summarized in Table 3, which reported run times of 14 to 40 min. Retention times were 3.70, 4.16, 4.41, and 4.58 min for MeP, EtP, PrP, and BuP, respectively, and 3.68, 4.15, 4.40, and 4.57 min for the internal standards MeP-d4, EtP-d4, PrP-d4, and BuP-d9 (Figure 1).
Ion chromatograms showing the quantification transitions for a urine extract at 2 ng mL-1 (QCLLOQ). (a) MeP (1), EtP (2), PrP (3), and BuP (4) with retention times of 3.70, 4.16, 4.41, and 4.58 min, respectively. (b) Internal standards MeP-d4 (1), EtP-d4 (2), PrP-d4 (3), and BuP-d9 (4) with retention times of 3.68, 4.15, 4.40, and 4.57 min, respectively.
Method validation
Linearity was acceptable for the evaluated analytes, with concentration ranges of 2 to 800 ng mL-1 for all target compounds, using 1 (x2)-1 weighted linear regression. All calibration curves showed r values greater than 0.99, with back-calculated calibrator concentrations within 85-115% of nominal values. Table 4 presents a summary of the validation parameters. Precision and accuracy for all compounds were within the acceptance ranges. For MeP, intra-assay precision ranged from 3.3 to 10.4%, inter-assay precision ranged from 1.1 to 5.1%, and accuracy was between 100.3 and 106.9%. For EtP, intra-assay precision ranged from 3.1 to 11.6%, inter-assay precision ranged from 1.9 to 4.8%, and accuracy ranged from 94.8 to 108.0%. For PrP, intra-assay precision ranged from 4.19 to 6.35%, inter-assay precision ranged from 1.20 to 3.52%, and accuracy ranged from 99.2 to 107.4%. For BuP, intra-assay precision ranged from 2.8 to 6.1%, inter-assay precision ranged from 0.7 to 7.1%, and accuracy ranged from 96.5 to 104.6%. All these values were within acceptance limits.48
The stability of PBs in urine samples was evaluated after two freezing and thawing cycles at −20 ºC for 14 days (Table 4). The variations for MeP were 97.6-103.3%, for EtP 98-102.9%, for PrP 84.2-95.1%, and for BuP 92.9-101.1%. Based on these data, the analytes were stable under these conditions, with no differences greater than 15% compared to the concentrations determined before the first freezing. No carryover effects were observed following the injection of a QCH sample, as no measurable PB peak area was detected in subsequent blank injections. Dilution integrity was assessed by diluting a QCH urine sample (50-fold) that was more concentrated than the highest calibrator (Table 5). The diluted samples showed acceptable accuracy: 102.71, 105.26, 100.23, and 104.42% for MeP, EtP, PrP, and BuP, respectively. The CV% for replicated samples ranged from 1.01 to 5.13%. Given these acceptable results, samples with concentrations above the ULOQ were diluted with blank urine and reanalyzed.
Method application
The method was applied to urine samples collected at the Integrated Center of Health Specialties at Universidade Feevale, an institution with a female predominance. Urine samples were collected from 100 healthy adult volunteers (96 women and 4 men), residing in the southern Brazilian cities of Novo Hamburgo, São Leopoldo, and Porto Alegre (Table S1, Supplementary Information (SI) section). The distribution between sexes represents the typical population of health sciences students and faculty members at the education institution where sampling was performed. Thus, the study essentially focuses on evaluating female exposure to PBs, with the male sample representing a small portion of the total sample. Descriptive characteristics and analyses of the volunteers are presented in Table 6. The group of volunteers analyzed in this study is characterized as urban, with a median age of 27 years (17-57 years).
The urinary and hair concentrations measured for all PBs are reported in Table 7. No adjustment for creatinine was made in PB concentrations, as creatinine concentrations were within the normal range. Furthermore, creatinine concentration depends not only on urinary excretion volume (urine dilution factor) but also on lean body mass.67 Therefore, this adjustment may introduce bias in exposure calculations and risk assessments.
All parameters, except for EtP in urine samples (concentration p = 0.77, EDI p = 0.98), demonstrated non-normal distributions for MeP, PrP, and BuP.
Urine samples revealed PB levels above the LLOQ in 98% of cases for MeP (2.14-815.03 ng mL-1), 34% for PrP (2.01-138.19 ng mL-1), 11% for EtP (2.15-6.23 ng mL-1), and 1% for BuP (2.92 ng mL-1). Similar findings were reported in a study using data from the U.S. National Health and Nutrition Examination Survey (NHANES) 2005-2006, which highlighted widespread PB exposure among the American population. In that study,60 MeP concentrations ranged from 1 to 7.30 ng mL-1, PrP from 0.2 to 7.21 ng mL-1, EtP from 1.0 to 1.11 ng mL-1, and BuP from 0.2 to 1.24 ng mL-1, with detection rates of 99.1% for MeP and 92.7% for PrP. Similarly, a 2011 biomonitoring study of healthy Danish men reported detection rates of 98% for both MeP and PrP, 80% for EtP, and 83% for BuP.32 In Brazil, there is a significant lack of information regarding human exposure to PBs through biomonitoring data. However, high levels of MeP, PrP, EtP and BuP have been detected in baby wipes25 and in aquatic ecosystems of southern Brazil.27 This highlights the importance of long-term monitoring to assess the potential health impacts of PBs and develop effective strategies for risk mitigation.
These high detection rates, especially for MeP and PrP, may be attributed to their widespread use in personal care products and food.59 In our study, only 2% of urine samples exceeded the ULOQ for MeP. In hair samples, 16, 11, 7, and 4% of samples exceeded the ULOQ for PrP, MeP, EtP, and BuP, respectively (Table S1, SI section). All samples with concentrations above the ULOQ were diluted and reanalyzed.
The PBs urine concentrations in the samples with quantifiable levels had a median of 15.63 ng mL-1 for MeP and interquartile range (IQR) (IQR 6.60-33.93); 13.02 ng mL-1 for PrP (IQR 4.84-24.03); for BuP just one sample was quantified (no IQR values) and for EtP 3.96-1.46 (mean-standard deviation (SD)). Biomonitoring studies of a demographically diverse group of 100 male and female adults from the USA reported median urinary concentrations of 43.9 ng mL-1 for MeP (IQR 14.6-180.0); 1 ng mL-1 for EtP (IQR < LOD-6.9), 9.1 ng mL-1 for PrP (IQR 1.9-49.2) and 0.5 ng mL-1 for BuP (IQR < LOD-3.3).18 MeP was the most frequently quantified PB in biomonitoring studies, with elevated levels reported across diverse populations. These include a mother-child cohort in Greece (median: 4.01 ng mL-1),68 healthy Danish men (median: 17.7 ng mL-1),32 and a mixed-gender population aged 2-87 years from nine countries: Korea (median: 112 ng mL-1), China (median: 10.1 ng mL-1), Japan (median: 8.65 ng mL-1), Saudi Arabia (median: 6.80 ng mL-1), India (median: 6.28 ng mL-1), USA (median: 4.23 ng mL-1), Kuwait (median: 4.03 ng mL-1), Greece (median: 4.01 ng mL-1), and Vietnam (median: 2.92 ng mL-1).19 These studies, conducted between 2006 and 2018, were influenced by the most recent regulations established by EFSA9 which remain in effect today.
In Brazil, Rocha et al.26 determined the concentrations of 40 endocrine disruptors (EDs) in the urine of 300 children aged 6 to 14, applying advanced data mining techniques to identify co-exposure profiles and their association with a biomarker of oxidative deoxyribonucleic acid (DNA) damage (8-OHdG). PBs were detected in over 50% of the analyzed urine samples, with MeP present in all samples, and mean concentrations of MeP (43.1 ng mL-1), PrP (3.12 ng mL-1), and EtP (0.19 ng mL-1). Recently, they addressed co-exposure to BPA, PBs (MeP and EtP), and dichlorophenols, concluding that it is associated with DNA damage in children. Combined toxicological assessment of EDs can be a practical method for assessing the hazards of combined and coexisting chemicals in the environment.69 A limiting factor in our study was the lack of analysis of combined EDs.
International data indicate comparable patterns of multi-exposure to bisphenols and PBs in children, though mean concentrations vary markedly across regions due to differences in regulation and product use.21,70 In South America, evidence is limited and methodologically inconsistent.71 Regulatory frameworks also diverge: the European Union enforces maximum limits for MeP and PrP and bans certain longer-chain PBs based on Scientific Committee on Consumer Safety (SCCS) assessments;72,73 Brazil’s 2024 ANVISA resolution (RDC 907/2024) updated prohibited/restricted substance lists without a general ban;11 Canada revised SCCS in Cosmetic Ingredient Hotlist (2024-2025),74 and the USA expanded oversight under the Modernization of Cosmetics Regulation Act (2022), though without federal prohibition.48
Data on PB quantification in urine, along with personal information, frequency of product use, EDI for MeP, EtP, PrP, and BuP, and HQ for MeP, EtP, and PrP, are presented on Tables S1 and S2 (SI section). A significant portion (96%) of the volunteers reported the use of three or more personal care products. Additionally, 92% of these volunteers indicated the use of three or more different products on at least three days per week. The most frequently used products were deodorants (99%), perfumes (94%), and creams (92%). In 2% of the samples, PB concentrations exceeded the ULOQ; these cases involved the use of more than three personal care products on at least three days per week, with deodorant being the most used product among these samples. Furthermore, 3% of the samples exhibited a HQ > 1, suggesting a potential health risk. These cases also involved the use of more than three personal care products on at least three days per week, with sunscreens and leave-on cosmetics being the most frequently used products. The cumulative risk assessment, performed using the HI, yielded results consistent with the individual risk evaluations. Three volunteers exhibited HI values of 2.02, 1.21, and 1.23, exceeding the threshold of concern and indicating potential health risks, warranting further investigation. For all remaining participants, the cumulative risk was not considered significant.
Cumulative exposure to PBs in individuals exceeding safety thresholds (HQ > 1) may contribute to greater long-term health risks. This does not imply a diagnosis of intoxication or disease but rather reflects a statistically significant increase in the likelihood of adverse outcomes, including metabolic and cardiovascular diseases,75,76 cancer,31,77 oxidative DNA damage,78,79 and mortality,80 with implications for epidemiological surveillance, product regulation, and public health strategies.81
PB exposure in vulnerable populations, including pregnant women, children and young people, has been linked to multiple potential adverse effects as supported by recent evidence.82-84 Specifically, children may be vulnerable to the impact of PBs due to age-related differences in physiology, anatomy, behavior, and toxicokinetics,85,86 as well as an increased susceptibility to disruptions in hormonal homeostasis, potentially affecting sex steroid hormone receptor activity.87 A study based on data from the U.S. National Health and Nutrition Examination Survey (NHANES) 2013-2016 evaluated 1,179 children aged 6 to 19 years. Exposure to MeP and PrP was generally associated with lower levels of total testosterone, free androgen index, and the testosterone-to-estradiol ratio, and with higher levels of sex hormone-binding globulin (SHBG), which may reduce the availability of biologically active sex hormones. These associations were more pronounced among pubertal compared to prepubertal children.84 On the other hand, results in a young men study suggest that urinary PBs may not adversely impact reproductive function,88 and have no association with total testosterone in children and adolescents,89 but further research is needed to confirm these findings in other male populations. Furthermore, exposure to PBs during pregnancy has been associated with potential risks to both maternal and fetal health through placental transfer.90 Reported alterations include increased maternal blood pressure and a heightened risk of gestational hypertension,91 fetal growth restriction,92 oxidative stress,82 hormonal and inflammatory changes,93 as well as possible metabolic impacts.94
Following current guidelines and recommended precautions, 3% of volunteers with HQ > 1 were advised to minimize cumulative exposure, particularly from cosmetic products. While the prevailing consensus indicates that the isolated use of PBs in cosmetics at regulated concentrations does not constitute a significant health risk, concurrent and excessive use of multiple products containing these preservatives may raise systemic exposure to levels linked to adverse outcomes, including estrogenic activity and detrimental effects on skin cells.95
The median EDI was 2.3 (IQR: 0.95-4.48), 0.71 (IQR: 0.48-1.14), 3.04 (IQR: 1.03-6.37), and 1.35 μg kg-1 day-1 for MeP, EtP, PrP, and BuP, respectively. A study on Chinese university students reported higher median EDI values of 25.9, 1.61, and 3.82 μg kg-1 day-1 for MeP, EtP, and PrP, respectively, with a combined EDI for all PBs of 382 μg kg-1 day-1, which is still below the acceptable daily intake (ADI) of 10 μg kg-1 day-1.96 Biomonitoring studies on PBs in countries like the USA, various Asian nations, and Greece, have revealed median EDI values for ∑MeP+EtP ranged from 0.62 to 34.2 μg kg-1 day-1, well below the ADI. For PrP, EDI values ranged from 0.02 to 15.5 μg kg-1 day-1,19 nearing the ADI threshold. However, EDI estimated from PB urine concentrations of samples from China and Korea showed EDI values of 111-174 μg kg-1 day-1 and 157-167 μg kg-1 day-1, respectively, exceeding the recommended ADI. These findings suggest potential health risks from PB exposure, particularly for PrP among some individuals in Asian countries19 like the levels observed in this Brazilian study.
Among the 100 volunteers a concerning of 3% (1.217-2.01) had HQ ≥ 1.0 (EDI risk) for PrP. 52.9% were at medium risk (0.10-1.0) for PrP, while 38.2% and 1.83% were at minimum risk (0.01-0.10) for PrP and ∑MeP+EtP, respectively. The only measurable BuP sample presented minimal risk. 89.9% of urine samples had HQ ≤ 0.01 (insignificant risk). All risk-classified individuals were above the PrP exposure limit (20 mg kg-1 day-1). Volunteers < LOQ were classified as HQ ≤ 0.01 where adverse effects are unlikely. Studies found that 0.9% of Chinese adult men had HQ > 1 driven by PrP.97 Similarly, an analysis of the German Environmental Specimen Bank from 1995 to 2012, involving male and female volunteers aged 20-30, revealed that 8.4% exhibited HQ > 1 due to the PrP levels, while ∑MeP+EtP levels resulted in HQ < 1.54 Additionally, an evaluation of urine samples from Chinese university students showed HQ < 1 for MeP, EtP, and PrP.65 A study of children in Spain also indicated that ΣMeP+EtP exposure posed low concern, with HQ < 1.21 Therefore, high daily exposure to PBs warrants attention. Given that personal care products are the primary source of PB exposure, regulations on these products have a direct impact on overall PB exposure and daily intake in both the general population and product users. However, it remains uncertain to what extent these measures will reduce exposure and whether this reduction will consistently achieve HQ < 1 for the general population.54
Hair testing could be valuable to evaluate long term exposure to environmental toxicants.40,41 Striped and colored hair were evident in 47% of the samples. Urinary concentrations of MeP (EDI and HQ) were significantly higher in individuals with blonde hair compared to those with dark hair (p < 0.05). Median MeP concentration in blonde hair was 26.93 ng g-1 (IQR 13.0-43.6 ng g-1) whereas in dark hair the median concentration was 14.98 ng g-1 (IQR 5.36-28 ng g-1). Significant differences were observed in the EDI for MeP and the combined EDI of ΣMeP+EtP between volunteers with blonde and dark hair. Specifically, the EDI for MeP was higher in volunteers with blonde hair (median: 4.29 μg kg-1 day-1; interquartile range [IQR]: 2.04-6.63) compared to those with dark hair (median: 2.11 μg kg-1 day-1; IQR: 0.65-3.44). Similarly, the EDI of ΣMeP+EtP was higher in blonde-haired volunteers (median: 4.71 μg kg-1 day-1; IQR: 3.12-10.54) than in dark-haired volunteers (median: 2.4 μg kg-1 day-1; IQR: 0.78-6.08). Additionally, the HQ of ΣMeP+EtP was higher in volunteers with blonde hair (median: 0.0004; IQR: 0.0002-0.0007) compared to those with dark hair (median: 0.0002; IQR: 0.00006-0.0003). The comparison of MeP concentration, EDI, and HQ according to hair color is presented in Figure 2. Significant positive correlations were observed between urinary and hair concentrations: MeP in urine versus PrP in hair (r = 0.260, p < 0.05), EDI for EtP in urine versus PrP in hair (r = 0.633, p < 0.05), and HQ for ΣMeP+EtP in urine versus PrP in hair (r = 0.245, p < 0.05). Additional correlations were noted between MeP in urine versus PrP in urine (r = 0.357, p < 0.05), EDI for MeP in urine versus HQ for PrP in urine (r = 0.538, p < 0.01), EDI for PrP in urine versus HQ for ΣMeP+EtP in urine (r = 0.496, p < 0.01), MeP in urine versus HQ for PrP in urine (r = 0.373, p < 0.05), EDI for MeP in urine versus EDI for PrP in urine (r = 0.264, p < 0.01). This study suggests that urine and hair provide different and complementary information due to their different time detection windows, being hair (months) and urine (hours).40 The limited number of participants with blond hair (n = 23) in the present study precludes investigation of the potential influence of confounding factors such as personal care product use patterns, socioeconomic status, or age. In the Spearman correlation analysis conducted by Hines et al.,98 no association was found between urinary PB concentrations and hair color.98 The findings of Appenzeller et al.99 suggest that the incorporation of basic drugs from the blood would be enhanced by electrostatic interactions with the carboxyl groups of melanin, although neutral drugs would be less affected by hair pigmentation. PBs are well formulated because they have a nearly neutral pH (effective between pH 4.5-7.5)98 and therefore would be little affected by pigmentation.
Urinary concentrations of MeP (EDI and HQ) were significantly higher in individuals with blonde hair (n = 23) compared to those with dark hair (n = 75) (p < 0.05). (a) MeP; (b) EDI for MeP; (c) HQ for ∑MeP+EtP; (d) EDI for ∑MeP+EtP.
These findings are consistent with previous reports showing positive correlations between MeP and PrP in foodstuffs,99 indoor dust30 and personal care products.100
Therefore, the presented results provide relevant initial evidence for evaluating the applicability and reproducibility of the method in future research, as well as guiding broader investigations in more diverse populations. However, this study presents certain limitations regarding the biomonitoring of exposure. The sample was obtained by convenience and consisted exclusively of students and members of the academic community from a single university, and therefore is not representative of the general population. Furthermore, the study population was predominantly female, which may be associated with lifestyle habits and exposure patterns that differ from those of the male population. Nevertheless, this study aimed to evaluate the applicability and robustness of the method for urinary biomonitoring analysis. Among the 100 participants, PrP was quantified in 34% of the samples, and only 3% presented a hazard quotient (HQ) > 1, indicating a potential health risk and limiting the feasibility of more detailed statistical comparisons across subgroups. These cases also involved the use of more than three personal care products on at least three days per week, with sunscreens and leave-on cosmetics being the most frequently used products.
We consider the results valid within the scope of the study, as they provide relevant initial evidence for evaluating the applicability and reproducibility of the method in future research, as well as guiding broader investigations in more diverse populations
Conclusions
In this study, we validated a highly sensitive method utilizing a rapid, simplified three-step SPE with no need for cartridge preconditioning, using HLB® sorbent, followed by LC-MS/MS. The method demonstrated excellent linearity, recovery, and reproducibility. The SPE procedure also provided significant advantages, including reduced solvent consumption and fewer extraction steps, thereby minimizing analyst exposure to hazardous chemicals. For the first time, this study provides data on the simultaneous quantification of four PBs in urine samples from 100 individuals residing in Southern Brazil. The median EDI was 2.3, 0.71, 3.04, and 1.35 μg kg-1 day-1 for MeP, EtP, PrP, and BuP, respectively. The findings suggest that PB exposure in this population is generally within safe limits, except for three volunteers whose HQ for PrP exceeded 1.0. Notably, MeP (EDI and HQ) concentrations in urine were significantly higher in individuals with blonde hair. Additionally, significant positive correlations were observed between PB levels in urine and hair.
Supplementary Information
Supplementary information is available free of charge at http://jbcs.sbq.org.br as a PDF file.
Data Availability Statement
All data are available in the text.
Acknowledgments
Loredo, C. D. was the recipient of a graduate scholarship from Capes. Linden, R. is recipient of a research scholarship from Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq, Brazil).
References
-
1 Abbas, S.; Greige-Gerges, H.; Karam, N.; Piet, M. H.; Netter, P.; Magdalou, J.; Drug Metab. Pharmacokinet. 2010, 25, 568. [Crossref]
» [Crossref] -
2 Shin, M. Y.; Choi, J. W.; Lee, S.; Kim, S.; Kho, Y.; Choi, K.; Kim, S.; Chemosphere 2023, 310, 136689. [Crossref]
» [Crossref] -
3 Nowak, K.; Ratajczak-Wrona, W.; Górska, M.; Jabłońska, E.; Mol. Cell. Endocrinol. 2018, 463, 238. [Crossref]
» [Crossref] -
4 Barkoski, J. M.; Busgang, S. A.; Bixby, M.; Bennett, D.; Schmidt, R. J.; Barr, D. B.; Panuwet, P.; Gennings, C.; Hertz-Picciotto, I.; Environ. Res. 2019, 179, 13. [Crossref]
» [Crossref] -
5 Tung, C. J.; Chen, M. H.; Lin, C. C.; Chen, P. C.; Environ. Int. 2024, 179, 108671. [Crossref]
» [Crossref] -
6 Oishi, S.; Arch. Toxicol. 2002, 76, 423. [Crossref]
» [Crossref] -
7 Smarr, M. M.; Sundaram, R.; Honda, M.; Kannan, K.; Buck Louis, G. M.; Environ. Health Perspect. 2017, 125, 730. [Crossref]
» [Crossref] -
8 European Commission (EU); Commission Regulation of 18 September 2014 of the European Parliament and of the Council on Cosmetic Products (Text with EEA relevance), https://eur-lex.europa.eu/eli/reg/2014/1004/oj, accessed in September 2025.
» https://eur-lex.europa.eu/eli/reg/2014/1004/oj -
9 EFSA Journal; Opinion of the Scientific Panel on Food Additives, Flavourings, Processing Aids and Materials in Contact with Food (AFC) Related to para Hydroxybenzoates (E 214-219), https://efsa.onlinelibrary.wiley.com/doi/epdf/10.2903/j.efsa.2004.83, accessed in September 2025.
» https://efsa.onlinelibrary.wiley.com/doi/epdf/10.2903/j.efsa.2004.83 -
10 U.S. Food and Drug Administration (FDA); Cosmetic Ingredients, https://www.fda.gov/cosmetics/cosmetic-products-ingredients/cosmetic-ingredients, accessed in September 2025.
» https://www.fda.gov/cosmetics/cosmetic-products-ingredients/cosmetic-ingredients -
11 Agência Nacional de Vigilância Sanitária (ANVISA); Resolução da Diretoria Colegiada (RDC) 528/2021, Dispõe sobre a Lista de Substâncias de Ação Conservante Permitidas para Produtos de Higiene Pessoal, Cosméticos e Perfumes e Internaliza a Resolução GMC MERCOSUL No. 35/20; https://anvisalegis.datalegis.net/action/UrlPublicasAction.php?acao=abrirAtoPublico#_ato=00000528&sgl_tipo=RDC&sgl_orgao=RDC/DC/ANVISA/MS&vlr_ano=2021&seq_ato=000&cod_modulo=134&cod_menu=1696, accessed in September 2025.
» https://anvisalegis.datalegis.net/action/UrlPublicasAction.php?acao=abrirAtoPublico#_ato=00000528&sgl_tipo=RDC&sgl_orgao=RDC/DC/ANVISA/MS&vlr_ano=2021&seq_ato=000&cod_modulo=134&cod_menu=1696 -
12 Dewalque, L.; Pirard, C.; Charlier, C.; BioMed. Res. Int. 2014, 2014, 166. [Crossref]
» [Crossref] -
13 Strømmen, K.; Lyche, J. L.; Moltu, S. J.; Müller, M. H. B.; Blakstad, E. W.; Brække, K.; Sakhi, A. K.; Thomsen, C.; Nakstad, B.; Rønnestad, A. E.; Drevon, C. A.; Iversen, P. O.; Chemosphere 2022, 309, 106876. [Crossref]
» [Crossref] -
14 Genuis, S. J.; Birkholz, D.; Curtis, L.; Sandau, C.; ISRN Toxicol. 2013, 2013, 1. [Crossref]
» [Crossref] -
15 Wang, Y.; Li, G.; Zhu, Q.; Liao, C.; Sci. Total Environ. 2021, 786, 147485. [Crossref]
» [Crossref] -
16 Martín, J.; Santos, J. L.; Aparicio, I.; Alonso, E.; Anal. Chim. Acta 2016, 945, 95. [Crossref]
» [Crossref] -
17 Darbre, P. D.; Aljarrah, A.; Miller, W. R.; Coldham, N. G.; Sauer, M. J.; Pope, G. S.; J. Appl. Toxicol. 2004, 24, 5. [Crossref]
» [Crossref] -
18 Ye, X.; Bishop, A. M.; Reidy, J. A.; Needham, L. L.; Calafat, A. M.; Environ. Health Perspect. 2006, 114, 1843. [Crossref]
» [Crossref] -
19 Honda, M.; Robinson, M.; Kannan, K.; Chemosphere 2018, 201, 13. [Crossref]
» [Crossref] -
20 Correia-Sá, L.; Kasper-Sonnenberg, M.; Schütze, A.; Pälmke, C.; Norberto, S.; Calhau, C.; Domingues, V. F.; Koch, H. M.; Environ. Sci. Pollut. Res. 2017, 24, 27502. [Crossref]
» [Crossref] -
21 Dualde, P.; León, N.; Sanchis, Y.; Corpas-Burgos, F.; Fernández, S. F.; Hernández, C. S.; Saez, G.; Pérez-Zafra, E.; Mora-Herranz, A.; Pardo, O.; Coscollà, C.; López, A.; Yusà, V.; Int. J. Environ. Res. Public Health 2021, 18, 8909. [Crossref]
» [Crossref] -
22 Murawski, A.; Tschersich, C.; Rucic, E.; Schwedler, G.; Moos, R. K.; Kasper-Sonnenberg, M.; Brüning, T.; Koch, H. M.; Kolossa-Gehring, M.; Environ. Res. 2021, 194, 110502. [Crossref]
» [Crossref] -
23 Ramos, T. S.; Gonçalves, K. B.; Marciano, L. P. A.; Rosa, M. A.; Martins, I.; Regul. Toxicol. Pharmacol. 2024, 151, 105667. [Crossref]
» [Crossref] -
24 Azeredo, D. B. C.; de Sousa Anselmo, D.; Soares, P.; Graceli, J. B.; Magliano, D. C.; Miranda-Alves, L.; Int. J. Mol. Sci. 2023, 24, 15246. [Crossref]
» [Crossref] -
25 Rocha, B. A.; Bocato, M. Z.; Latorraca, E. F.; Ximeneza, J. P. B.; Barbosa Jr., F.; Quim. Nova 2020, 43, 442. [Crossref]
» [Crossref] -
26 Rocha, B. A.; de Oliveira, A. R. M.; Barbosa, F.; Talanta 2018, 183, 94. [Crossref]
» [Crossref] -
27 dos Santos, M. M.; Brehm, F. A.; Filippe, T. C.; Knapik, H. G.; de Azevedo, J. C. R.; Rev. Bras. Recur. Hidr. 2016, 21, 603. [Crossref]
» [Crossref] -
28 Sanchis, Y.; Coscollà, C.; Corpas-Burgos, F.; Vento, M.; Gormaz, M.; Yusà, V.; Environ. Res. 2020, 185, 109481. [Crossref]
» [Crossref] -
29 Reimann, B.; Sleurs, H.; Dockx, Y.; Rasking, L.; De Boever, P.; Pirard, C.; Charlier, C.; Nawrot, T. S.; Plusquin, M.; Chemosphere 2023, 328, 138570. [Crossref]
» [Crossref] -
30 Li, C.; Chen, X.; Environ. Sci. Pollut. Res. 2023, 30, 26929. [Crossref]
» [Crossref] -
31 Mao, W.; Qu, J.; Zhong, S.; Wu, X.; Mao, K.; Liao, K.; Jin, H.; Environ. Sci. Pollut. Res. 2023, 30, 66186. [Crossref]
» [Crossref] -
32 Frederiksen, H.; Jørgensen, N.; Andersson, A. M.; J. Expo. Sci. Environ. Epidemiol. 2011, 21, 262. [Crossref]
» [Crossref] -
33 Moos, R. K.; Angerer, J.; Dierkes, G.; Brüning, T.; Koch, H. M.; Arch. Toxicol. 2016, 90, 2699. [Crossref]
» [Crossref] - 34 Souza, F. P.; Toxicologia Forense: Amostras Biológicas em Análises Forenses: Matrizes Usuais (Urina e Sangue), 1st ed.; Edgard Blücher: São Paulo, Brazil, 2018, p. 382-384.
-
35 Wojtkiewicz, J.; Tzatzarakis, M.; Vakonaki, E.; Makowska, K.; Gonkowski, S.; Sci. Rep. 2021, 11, 23673. [Crossref]
» [Crossref] -
36 Robin, J.; Binson, G.; Albouy, M.; Sauvaget, A.; Pierre-Eugène, P.; Migeot, V.; Dupuis, A.; Venisse, N.; Ecotoxicol. Environ. Saf. 2022, 243, 113986. [Crossref]
» [Crossref] -
37 Claessens, J.; Pirard, C.; Charlier, C.; Sci. Total Environ. 2022, 815, 152734. [Crossref]
» [Crossref] -
38 Karzi, V.; Tzatzarakis, M.; Katsikantami, I.; Stavroulaki, A.; Alegakis, A.; Vakonaki, E.; Xezonaki, P.; Sifakis, S.; Rizos, A.; Tsatsakis, A.; Environ. Res. 2019, 178, 108692. [Crossref]
» [Crossref] -
39 Rodríguez-Gómez, R.; Martín, J.; Zafra-Gómez, A.; Alonso, E.; Vílchez, J. L.; Navalón, A.; Chemosphere 2017, 168, 676. [Crossref]
» [Crossref] -
40 Fäys, F.; Hardy, E. M.; Palazzi, P.; Haan, S.; Beausoleil, C.; Appenzeller, B. M. R.; Sci. Total Environ. 2021, 778, 146330. [Crossref]
» [Crossref] -
41 Hardy, E. M.; Dereumeaux, C.; Guldner, L.; Briand, O.; Vandentorren, S.; Oleko, A.; Zaros, C.; Appenzeller, B. M. R.; Environ. Int. 2021, 152, 106481. [Crossref]
» [Crossref] -
42 Ye, X.; Kuklenyik, Z.; Bishop, A. M.; Needham, L. L.; Calafat, A. M.; J. Chromatogr. B 2006, 844, 53. [Crossref]
» [Crossref] -
43 Zhang, X.; Iraneta, P. C.; Marszalkowski, F. J.; Fountain, K. J.; A Simplified Solid Phase Extraction (SPE) Protocol for Bioanalysis Using Oasis HLB, https://www.waters.com/content/dam/waters/en/app-notes/2014/720005140/720005140-es.pdf, accessed in September 2025.
» https://www.waters.com/content/dam/waters/en/app-notes/2014/720005140/720005140-es.pdf -
44 Franke, J. P.; de Zeeuw, R. A.; J. Chromatogr. B 1998, 713, 51. [Crossref]
» [Crossref] -
45 Galera, M. C.; dos Santos, N. C. B. F.; Antunes, M. V.; Peteffi, G. P.; da Costa, J. L.; Lanaro, R.; Linden, R.; Microchem. J. 2024, 207, 111835. [Crossref]
» [Crossref] -
46 Hazirah, A. A.; Rofiee, M. S.; Jam, M. Z. J.; Jamari, M. H.; Janor, R. M.; James, R. J.; Kek, T. L.; Salleh, M. Z.; Malays. J. Anal. Sci. 2019, 23, 336. [Crossref]
» [Crossref] -
47 Química Clínica Aplicada S. A.; Mindray BS 200, https://technolabmex.com/wp-content/uploads/2016/05/AA-MINDRAY-BS200.pdf, accessed in September 2025.
» https://technolabmex.com/wp-content/uploads/2016/05/AA-MINDRAY-BS200.pdf -
48 U.S. Food and Drug Administration (FDA); Cder M10 Bioanalytical Method Validation and Study Sample Analysis Guidance for Industry, 2023, https://www.fda.gov/vaccines-blood-biologics/guidance-compliance-regulatory-information-biologics/biologics-guidances, accessed in September 2025.
» https://www.fda.gov/vaccines-blood-biologics/guidance-compliance-regulatory-information-biologics/biologics-guidances -
49 Matuszewski, B. K.; Constanzer, M. L.; Chavez-Eng, C. M.; Anal. Chem. 2003, 75, 3019. [Crossref]
» [Crossref] -
50 Sakhi, A. K.; Sabaredzovic, A.; Papadopoulou, E.; Cequier, E.; Thomsen, C.; Environ. Int. 2018, 114, 242. [Crossref]
» [Crossref] -
51 FAO/WHO Expert Committee on Food Additives; Toxicological Evaluation of Certain Food Additives with a Review of General Principles and of Specifications; FAO and WHO: Geneva, 1974, p. 11. [ PubMed]
» PubMed -
52 European Food Safety Authority (EFSA); EFSA J. 2013, 11, 3313. [Crossref]
» [Crossref] -
53 Dirtu, A. C.; Geens, T.; Dirinck, E.; Malarvannan, G.; Neels, H.; Van Gaal, L.; Jorens, P. G.; Covaci, A.; Environ. Int. 2013, 59, 344. [Crossref]
» [Crossref] -
54 Moos, R. K.; Apel, P.; Schröter-Kermani, C.; Kolossa-Gehring, M.; Brüning, T.; Koch, H. M.; J. Expo. Sci. Environ. Epidemiol. 2017, 27, 591. [Crossref]
» [Crossref] -
55 Science Policy Council; Guidance on Cumulative Risk Assessment, Part 1, Planning and Scoping, https://www.epa.gov/sites/default/files/2015-01/documents/cumrisk2_0.pdf, accessed in September 2025.
» https://www.epa.gov/sites/default/files/2015-01/documents/cumrisk2_0.pdf -
56 Li, L.; Dong, Y.; Chen, Y.; Jiao, J.; Zou, X.; Toxics 2022, 10, 659. [Crossref]
» [Crossref] -
57 Lioy, P. J.; Hauser, R.; Gennings, C.; Koch, H. M.; Mirkes, P. E.; Schwetz, B. A.; Kortenkamp, A.; J. Exposure Sci. Environ. Epidemiol. 2015, 25, 343. [Crossref]
» [Crossref] -
58 Gennings, C.; Hauser, R.; Koch, H. M.; Kortenkamp, A.; Lioy, P. J.; Mirkes, P. E.; Schwetz, B. A.; Chronic Hazard Advisory Panel on Phthalates and Phthalate Alternatives, U.S. Consumer Product Safety Commission, 2014. https://www.cpsc.gov/s3fs-public/CHAP-REPORT-With-Appendices.pdf, accessed in September 2025.
» https://www.cpsc.gov/s3fs-public/CHAP-REPORT-With-Appendices.pdf -
59 Calafat, A. M.; Ye, X.; Wong, L. Y.; Bishop, A. M.; Needham, L. L.; Environ. Health Perspect. 2010, 118, 679. [Crossref]
» [Crossref] -
60 Musatadi, M.; Andrés-Maguregi, A.; De Angelis, F.; Prieto, A.; Anakabe, E.; Olivares, M.; Etxebarria, N.; Zuloaga, O.; Chemosphere 2023, 339, 139690. [Crossref]
» [Crossref] -
61 Ren, L.; Fang, J.; Liu, G.; Zhang, J.; Zhu, Z.; Liu, H.; Lin, K.; Zhang, H.; Lu, S.; Anal. Bioanal. Chem. 2016, 408, 2621. [Crossref]
» [Crossref] -
62 Dewalque, L.; Pirard, C.; Dubois, N.; Charlier, C.; J. Chromatogr. B 2014, 949-950, 37. [Crossref]
» [Crossref] -
63 Monfort, N.; Ventura, R.; Balcells, G.; Segura, J.; J. Chromatogr. B 2012, 908, 113. [Crossref]
» [Crossref] -
64 Shaaban, H.; Mostafa, A.; Alhajri, W.; Almubarak, L.; AlKhalifah, K.; J. Liq. Chromatogr. Relat. Technol. 2018, 41, 621. [Crossref]
» [Crossref] -
65 Anastas, P. T.; Crit. Rev. Anal. Chem. 1999, 29, 167. [Crossref]
» [Crossref] -
66 Musatadi, M.; Caballero, C.; Mijangos, L.; Prieto, A.; Olivares, M.; Zuloaga, O.; Anal. Bioanal. Chem. 2022, 414, 6855. [Crossref]
» [Crossref] -
67 Baxmann, A. C.; Ahmed, M. S.; Marques, N. C.; Menon, V. B.; Pereira, A. B.; Kirsztajn, G. M.; Heilberg, I. P.; Clin. J. Am. Soc. Nephrol. 2008, 3, 348. [Crossref]
» [Crossref] -
68 Myridakis, A.; Chalkiadaki, G.; Fotou, M.; Kogevinas, M.; Chatzi, L.; Stephanou, E. G.; Environ. Sci. Technol. 2016, 50, 932. [Crossref]
» [Crossref] -
69 Dutta, S.; Sengupta, P.; Bagchi, S.; Chhikara, B. S.; Pavlík, A.; Sláma, P.; Roychoudhury, S.; Front. Cell Dev. Biol. 2023, 11, 1162015. [Crossref]
» [Crossref] -
70 Acevedo, J. M.; Kahn, L. G.; Pierce, K. A.; Carrasco, A.; Rosenberg, M. S.; Trasande, L.; Environ. Res. 2025, 264, 120341. [Crossref]
» [Crossref] -
71 Cortés, S.; Orena, V.; Rudenlinger, J.; Valenzuela, M.; Alcalá, L. Q.; Fernandez, M.; Arrebola, J. P.; Environ. Health Perspect. 2024 [Crossref]
» [Crossref] -
72 Scientific Committee on Consumer Safety (SCCS); Opinion on Parabens COLIPA n° P821348/10, https://ec.europa.eu/health/scientific_committees/consumer_safety/docs/sccs_o_041.pdf, accessed in September 2025.
» https://ec.europa.eu/health/scientific_committees/consumer_safety/docs/sccs_o_041.pdf -
73 Scientific Committee on Consumer Safety (SCCS); SCCS 2023, Opinion on Butylparaben (CAS No. 94-26-8, EC No. 202-318-7) - Children’s exposure, https://health.ec.europa.eu/publications/sccs-opinion-butylparaben-cas-no-94-26-8-ec-no-202-318-7-childrens-exposure_en, accessed in September 2025.
» https://health.ec.europa.eu/publications/sccs-opinion-butylparaben-cas-no-94-26-8-ec-no-202-318-7-childrens-exposure_en -
74 Government of Canada; Cosmetic Ingredient Hotlist, https://www.canada.ca/en/health-canada/services/consumer-product-safety/cosmetics/cosmetic-ingredient-hotlist-prohibited-restricted-ingredients/hotlist.html?utm_source=chatgpt.com#tbl1, accessed in September 2025.
» https://www.canada.ca/en/health-canada/services/consumer-product-safety/cosmetics/cosmetic-ingredient-hotlist-prohibited-restricted-ingredients/hotlist.html?utm_source=chatgpt.com#tbl1 -
75 Song, Y.; Wang, M.; Nie, L.; Liao, W.; Wei, D.; Wang, L.; Wang, J.; Xu, Q.; Huan, C.; Jia, Z.; Mao, Z.; Wang, C.; Huo, W.; Chemosphere 2023, 340, 139868. [Crossref]
» [Crossref] -
76 Zhang, X.; Zhang, Y.; Lu, H.; Yu, F.; Shi, X.; Ma, B.; Zhou, S.; Wang, L.; Lu, Q.; Chemosphere 2023, 339, 139656. [Crossref]
» [Crossref] -
77 Fernández-Martínez, N. F.; Rodríguez-Barranco, M.; Zamora-Ros, R.; Guevara, M.; Colorado-Yohar, S. M.; Jiménez-Zabala, A.; Arrebola, J. P.; Iribarne-Durán, L. M.; Molina, G.; Agudo, A.; Trobajo-Sanmartín, C.; Chirlaque, M. D.; Amiano, P.; Sánchez, M. J.; Environ. Sci. Pollut. Res. Int. 2024, 31, 6186. [Crossref]
» [Crossref] -
78 Liao, Q.; Huang, H.; Zhang, X.; Ma, X.; Peng, J.; Zhang, Z.; Chen, C.; Lv, Y.; Zhu, X.; Zheng, J.; Zeng, X.; Xing, X.; Deng, Q.; Dong, G.; Wei, Q.; Hou, M.; Xiao, Y.; Chemosphere 2022, 308, 136394. [Crossref]
» [Crossref] -
79 Rocha, B. A.; Asimakopoulos, A. G.; Honda, M.; da Costa, N. L.; Barbosa, R. M.; Barbosa, F.; Kannan, K.; Environ. Int. 2018, 116, 269. [Crossref]
» [Crossref] -
80 Hendryx, M.; Luo, J.; Environ. Res. 2022, 205, 112415. [Crossref]
» [Crossref] -
81 Huang, P. C.; Chen, H. C.; Chou, W. C.; Lin, H. W.; Chang, W. T.; Chang, J. W.; Sci. Total Environ. 2022, 843, 156821. [Crossref]
» [Crossref] -
82 Lan, L.; Wan, Y.; Qian, X.; Wang, A.; Mahai, G.; He, Z.; Li, Y.; Xu, S.; Zheng, T.; Xia, W.; Environ. Int. 2022, 165, 107300. [Crossref]
» [Crossref] -
83 Varghese, B.; Jala, A.; Das, P.; Borkar, R. M.; Adela, R.; Environ. Sci. Pollut. Res. 2022, 29, 21642. [Crossref]
» [Crossref] -
84 Hu, P.; Pan, C.; Su, W.; Vinturache, A.; Hu, Y.; Dong, X.; Ding, G.; Sci. Total Environ. 2022, 822, 153548. [Crossref]
» [Crossref] -
85 Braun, J. M.; Nat. Rev. Endocrinol. 2017, 13, 161. [Crossref]
» [Crossref] -
86 Miller, M. D.; Marty, M. A.; Arcus, A.; Brown, J.; Morry, D.; Sandy, M.; Regul. Toxicol. Pharmacol. 2002, 21, 403. [Crossref]
» [Crossref] -
87 Vandenberg, L. N.; Colborn, T.; Hayes, T. B.; Heindel, J. J.; Jacobs, D. R.; Lee, D. H.; Shioda, T.; Soto, A. M.; vom Saal, F. S.; Welshons, W. V.; Zoeller, R. T.; Myers, J. P.; Endocr. Ver. 2012, 33, 378. [Crossref]
» [Crossref] -
88 Adoamnei, E.; Mendiola, J.; Moñino-García, M.; Vela-Soria, F.; Iribarne-Durán, L. M.; Fernández, M. F.; Olea, N.; Jørgensen, N.; Swan, S. H.; Torres-Cantero, A. M.; Sci. Total Environ. 2018, 621, 201. [Crossref]
» [Crossref] -
89 Scinicariello, F.; Buser, M. C.; Environ. Health Perspect. 2016, 124, 1898. [Crossref]
» [Crossref] -
90 Li, A.; Wang, F.; Tao, L.; Ma, C.; Bi, L.; Song, M.; Jiang, G.; Talanta 2022, 248, 123639. [Crossref]
» [Crossref] -
91 Varshavsky, J. R.; Meeker, J. D.; Zimmerman, E.; Woodbury, M. L.; Aung, M. T.; Rosario-Pabon, Z. Y.; Cathey, A. L.; Vélez-Vega, C. M.; Cordero, J.; Alshawabkeh, A.; Eick, S. M.; Environ. Health Perspect. 2024, 132, 87004. [Crossref]
» [Crossref] -
92 Trasande, L.; Nelson, M. E.; Alshawabkeh, A.; Barrett, E. S.; Buckley, J. P.; Dabelea, D.; Dunlop, A. L.; Herbstman, J. B.; Meeker, J. D.; Naidu, M.; Newschaffer, C.; Padula, A. M.; Romano, M. E.; Ruden, D. M.; Sathyanarayana, S.; Schantz, S. L.; Starling, A. P.; Etzel, T.; Hamra, G. B.; Environ. Int. 2024, 183, 108378. [Crossref]
» [Crossref] -
93 Jedynak, P.; Bustamante, M.; Rolland, M.; Mustieles, V.; Thomsen, C.; Sakhi, A. K.; Sabaredzovic, A.; Foraster, M.; Gascon, M.; Gómez-Roig, M. D.; Llurba, E.; Rivas, I.; Ouellet-Morin, I.; Bayat, S.; Lyon-Caen, S.; Pozo, O. J.; Vrijheid, M.; Sunyer, J.; Slama, R.; Dadvand, P.; Philippat, C.; Environ. Health Perspect. 2025, 133, 5701. [Crossref]
» [Crossref] -
94 Zhao, H.; Zheng, Y.; Zhu, L.; Xiang, L.; Zhou, Y.; Li, J.; Fang, J.; Xu, S.; Xia, W.; Cai, Z.; Environ. Sci. Technol. 2020, 54, 3447. [Crossref]
» [Crossref] -
95 Matwiejczuk, N.; Galicka, A.; Brzóska, M. M.; J. Appl. Toxicol. 2020, 40, 176. [Crossref]
» [Crossref] -
96 Zhang, H.; Quan, Q.; Li, X.; Sun, W.; Zhu, K.; Wang, X.; Sun, X.; Zhan, M.; Xu, W.; Lu, L.; Fan, J.; Gao, Y.; Environ. Res. 2020, 183, 109288. [Crossref]
» [Crossref] -
97 Miao, Y.; Chen, P.-P.; Zhang, M.; Cui, F.-P.; Liu, C.; Deng, Y.-L.; Zeng, J.-Y.; Yin, W.-J.; Zeng, Q.; Environ. Res. 2023, 218, 115026. [Crossref]
» [Crossref] -
98 Hines, E. P.; Mendola, P.; von Ehrenstein, O. S.; Ye, X.; Calafat, A.M.; Fenton, S. E.; Reprod. Toxicol. 2015, 54, 120. [Crossref]
» Crossref -
99 Appenzeller, B. M. R.; Tsatsakis, A. M.; Toxicol. Lett. 2012, 210, 119. [Crossref]
» [Crossref] -
100 Soni, M. G.; Carabin, I. G.; Burdock, G. A.; Food Chem. Toxicol. 2005, 43, 985. [Crossref]
» [Crossref]




