Acessibilidade / Reportar erro

Kidney disease and calibration of creatinine determination: where are we in Brazil?

Recommendations dictate that serum creatinine levels be measured using specific kits calibrated based on international standards using isotope dilution mass spectrometry (IDMS). According to laboratory quality management organizations, the total analytical error associated with the measurement of creatinine levels must be routinely monitored. And last but not least, laboratories should report the glomerular filtration rates (GFR) calculated from established formulas (such as the CKD-EPI) alongside creatinine serum levels.11 Kidney Disease: Improving Global Outcomes (KDIGO) CKD Work Group. KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease. Kidney Int Suppl 2013;3:1-150.

The purpose of these recommendations is to increase the accuracy of GFR estimates based on creatinine levels, the parameter that best describes renal function.

In practical terms, when recommendations are not followed, GFR levels and the ensuing clinical judgment are distorted. For example, various modified test methods based on the Jaffe reaction may underestimate serum creatinine values in individuals with high levels of serum bilirubin or overshoot them by as much as 20% in patients on cephalosporin due to analytical interferences.22 Stevens LA, Levey AS. Measured GFR as a confirmatory test for estimated GFR. J Am Soc Nephrol 2009;20:2305-13. DOI: http://dx.doi.org/10.1681/ASN.2009020171
http://dx.doi.org/10.1681/ASN.2009020171...
Possible deleterious consequences such as incorrect diagnosis of renal disease, inadequate dosage of drugs excreted via the kidneys, and delayed referral to nephrology care may occur as a result of improper serum creatinine level measurement.

The level of compliance to recommendations among Brazilian laboratories is unknown. Neither the Brazilian Health Surveillance Agency [(ANVISA), contact number 2014676521] or the Brazilian Society of Clinical Pathology and Medical Laboratories [(SBPC/ML), call center] have that information.

An independent survey carried out with 42 laboratories from all over Brazil revealed that 14 (33%) labs did not use traceable methods or IDMS to measure serum creatinine levels (Alcântara FFP, 2010). One may assume that this ratio is even greater in the Brazilian countryside, considering the widespread availability of kits not adequately calibrated to measure serum creatinine levels. Laboratories not participating in quality assessment programs are believed to have total analytical error levels above recommended thresholds.

This is a preoccupying scenario for a number of reasons. First, the GFR estimated from serum creatinine is a cornerstone in the diagnosis and stratification of patients with chronic kidney disease (CKD) and acute kidney injury (AKI). Additionally, GFR is more than an indicator of renal function, as it is directly associated with risk of cardiovascular death and global mortality.11 Kidney Disease: Improving Global Outcomes (KDIGO) CKD Work Group. KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease. Kidney Int Suppl 2013;3:1-150.,33 Kidney Disease: Improving Global Outcomes (KDIGO) Acute Kidney Injury Work Group. KDIGO Clinical Practice Guideline for Acute Kidney Injury. Kidney Int Suppl 2012;2:1-138.

The Brazilian Ministry of Health recently passed legislation concerning specifically the policies around the care provided to patients with CKD.44 Brasil. Ministério da Saúde. Portaria Nº 389, de 13 de março de 2014 [citada 17 de fevereiro de 2015]. Disponível em: Disponível em: http://bvsms.saude.gov.br/bvs/saudelegis/gm/2014/prt0389_13_03_2014.html
http://bvsms.saude.gov.br/bvs/saudelegis...
And in it, the diagnosis and stratification of patients with CKD is based on the GFR. Considering that more than 10 million Brazilians have some degree of CKD, the quality of the care provided to this population may be severely affected if serum creatinine levels are inaccurately measured.

Encouraging the standardization of serum creatinine level measurement at a national level may become an important step toward improving the diagnosis and stratification of individuals with CKD and AKI. This measure might have an important role in the prevention and treatment of kidney disease. Additionally, the addition of the estimated GFR level alongside the serum creatinine level in test reports may increase the sensitivity of kidney disease detection.55 Mastroianni-Kirsztajn G, Bastos MG, Burdmann EA. Strategies of the Brazilian chronic kidney disease prevention campaign (2003-2009). Nephron Clin Pract 2011;117:c259-65. PMID: 20861650 DOI: http://dx.doi.org/10.1159/000320741
http://dx.doi.org/10.1159/000320741...

Referências

  • 1
    Kidney Disease: Improving Global Outcomes (KDIGO) CKD Work Group. KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease. Kidney Int Suppl 2013;3:1-150.
  • 2
    Stevens LA, Levey AS. Measured GFR as a confirmatory test for estimated GFR. J Am Soc Nephrol 2009;20:2305-13. DOI: http://dx.doi.org/10.1681/ASN.2009020171
    » http://dx.doi.org/10.1681/ASN.2009020171
  • 3
    Kidney Disease: Improving Global Outcomes (KDIGO) Acute Kidney Injury Work Group. KDIGO Clinical Practice Guideline for Acute Kidney Injury. Kidney Int Suppl 2012;2:1-138.
  • 4
    Brasil. Ministério da Saúde. Portaria Nº 389, de 13 de março de 2014 [citada 17 de fevereiro de 2015]. Disponível em: Disponível em: http://bvsms.saude.gov.br/bvs/saudelegis/gm/2014/prt0389_13_03_2014.html
    » http://bvsms.saude.gov.br/bvs/saudelegis/gm/2014/prt0389_13_03_2014.html
  • 5
    Mastroianni-Kirsztajn G, Bastos MG, Burdmann EA. Strategies of the Brazilian chronic kidney disease prevention campaign (2003-2009). Nephron Clin Pract 2011;117:c259-65. PMID: 20861650 DOI: http://dx.doi.org/10.1159/000320741
    » http://dx.doi.org/10.1159/000320741

Publication Dates

  • Publication in this collection
    Oct-Dec 2015

History

  • Received
    24 Apr 2015
  • Accepted
    01 June 2015
Sociedade Brasileira de Nefrologia Rua Machado Bittencourt, 205 - 5ºandar - conj. 53 - Vila Clementino - CEP:04044-000 - São Paulo SP, Telefones: (11) 5579-1242/5579-6937, Fax (11) 5573-6000 - São Paulo - SP - Brazil
E-mail: bjnephrology@gmail.com