Acessibilidade / Reportar erro

Determination of the power-duration relationship in upper-limb exercises

Abstracts

OBJECTIVES: To determine the power-duration relationship in upper limb exercises and to investigate the relationships between parameters derived from this function with physiological indicators of aerobic fitness. METHODS: Ten healthy men (26.2±2.3 years, 75.0±11.8 kg, 178.2±11.5 cm and 15.0±5.7% body fat) performed a ramped test on an arm cycle ergometer with increments of 20 W/min. Subsequently, five tests with constant load were performed until exhaustion, with 70, 80, 90, 95 and 100% difference between VT1 and VO2peak. The critical power (CP) was obtained by means of linearization of the power-duration function. RESULTS: The power-duration relationship was described using an adjusted function (r=0.98±0.02). The VO2 at CP (2.66±0.62 l/min) was higher than VT1 (1.62±0.38 l/min) and VT2 (2.36±0.59 l/min), but lower than VO2peak (3.06±0.62 l/min). The CP workload (103.0±26 W) was significantly different from VT1 (69.5±21 W) and VO2peak workloads (151.0±26.3), but was no different of VT2 (103.5±30.8 W). The association between critical power and aerobic condition indexes were always significant when expressed as VO2 (0.73 to 0.78, p<0.05) and in W (0.83 to 0.91, p<0.05). Determination of CP in upper-limb dynamic exercises is simple and inexpensive, and can be used by physical therapists for prescribing and evaluating upper-limb training programs. CONCLUSIONS: The power-duration relationship in upper-limb exercises can be described by a hyperbolic function and it is associated with physiological indicators of aerobic fitness.

critical power; upper limbs; metabolic thresholds


OBJETIVOS: Determinar a relação potência-duração em exercícios de membros superiores (MMSS) e verificar a relação dos parâmetros derivados dessa função com indicadores fisiológicos de aptidão aeróbia. Métodos: Dez homens saudáveis (26,2±2,3 anos, 75,0±11,8 kg, 178,2±11,5 cm e 15,0±5,7% de gordura) realizaram um teste de rampa em cicloergômetro de braço com incrementos de 20 W/min. Posteriormente, cinco testes de carga constante até a exaustão a 70, 80, 90, 95 e 100% da diferença entre LV1 e o VO2pico foram realizados. A potência crítica (PC) foi obtida por meio da linearização da função potência-duração. RESULTADOS: A relação potência-duração foi descrita pela função ajustada (r=0,98±0,02). O VO2 na PC (2,66±0,62 l/min) foi maior do que no LV1 (1,62±0,38 l/min) e LV2 (2,36±0,59 l/min, respectivamente), mas menor do que o VO2pico (3,06±0,62 l/min). A carga da PC (103,0±26,0 W) foi diferente da encontrada em LV1 (69,5±21 W) e VO2pico (151,0±26,3 W), mas não da em LV2 (103,5±30,8 W). A associação entre a PC e esses indicadores de aptidão aeróbia foram todas significantes quando expressas em VO2 (0,73 a 0,78; p<0,05) e em W (0,83 a 0,91; p<0,05). A determinação da PC em exercícios dinâmicos de MMSS é simples e de baixo custo, podendo ser utilizada pelo fisioterapeuta na prescrição e avaliação do treinamento de MMSS. CONCLUSÃO: A relação potência-duração em exercícios com os MMSS pode ser descrita por uma função hiperbólica e está associada a indicadores fisiológicos da aptidão aeróbia.

potência crítica; membros superiores; limiares metabólicos


ORIGINAL ARTICLE

IUndergraduate Physical Therapy Course, School of Health, Universidade Metodista de São Paulo, São Paulo (SP), Brazil

IIDepartment of Physical Education, Universidade Federal de Lavras (UFLA), Lavras (MG), Brazil

IIIDepartment of Medicine, Universidade Federal de São Paulo (UNIFESP), São Paulo (SP), Brazil

IVDepartment of Physiology, UNIFESP

Correspondence to

ABSTRACT

OBJECTIVES: To determine the power-duration relationship in upper limb exercises and to investigate the relationships between parameters derived from this function with physiological indicators of aerobic fitness.

METHODS: Ten healthy men (26.2±2.3 years, 75.0±11.8 kg, 178.2±11.5 cm and 15.0±5.7% body fat) performed a ramped test on an arm cycle ergometer with increments of 20 W/min. Subsequently, five tests with constant load were performed until exhaustion, with 70, 80, 90, 95 and 100% difference between VT1 and VO2peak. The critical power (CP) was obtained by means of linearization of the power-duration function.

RESULTS: The power-duration relationship was described using an adjusted function (r=0.98±0.02). The VO2 at CP (2.66±0.62 l/min) was higher than VT1 (1.62±0.38 l/min) and VT2 (2.36±0.59 l/min), but lower than VO2peak (3.06±0.62 l/min). The CP workload (103.0±26 W) was significantly different from VT1 (69.5±21 W) and VO2peak workloads (151.0±26.3), but was no different of VT2 (103.5±30.8 W). The association between critical power and aerobic condition indexes were always significant when expressed as VO2 (0.73 to 0.78, p<0.05) and in W (0.83 to 0.91, p<0.05). Determination of CP in upper-limb dynamic exercises is simple and inexpensive, and can be used by physical therapists for prescribing and evaluating upper-limb training programs.

CONCLUSIONS: The power-duration relationship in upper-limb exercises can be described by a hyperbolic function and it is associated with physiological indicators of aerobic fitness.

Key words: critical power; upper limbs; metabolic thresholds.

Introduction

When assessing and prescribing exercises for prevention of orthopedic, cardiothoracic or neurological lower-limb (LL) dysfunctions and functional rehabilitation among such individuals, it is necessary for physical therapists to know about the physiological basis that characterizes load threshold determinations between upper-limb (UL) work intensity domains. The most commonly used parameters are the physiological transition threshold (PTT) and the maximum oxygen uptake or peak (VO2max/peak)1.

Another parameter used is the power that in theory could be sustained over the long term without fatigue. This is known as the critical power (CP) or critical velocity (CV). It is determined by analyzing the rectangular hyperbolic relationship between power developed (W) and time elapsed until exhaustion (t) for high-intensity and constant load exercises2-4. In other words, it appears that when analyzing the resulting equation, the endurance (capability to perform an exercise for a prolonged period of time) relies directly on the curvature constant and inversely on the power applied above CP2,3. Within this context, CP is found to be above the ventilatory anaerobic threshold (VT1), in which the load is approximately 60-65% of the difference between VT1 and VO2max, at least for LL exercises performed by young individuals4-6. Thus, Whipp and Ozyener7 proposed that VT1 would mark the transition between moderate and high-intensity exercises, and that the CP would divide intense and very intense domains close to the respiratory compensation point (VT2)8. This would extend to the VO2max load.

The W-t relationship has been extensively studied in exercises performed using small or large muscle groups at different levels of physical activity, in response to several interventions, even in patients with ventilatory restriction3,9. Moreover, as seen in relation to PTT, it has been demonstrated that CP is sensitive to the effects of training. In this respect, there is little data in the literature regarding whether the response to high intensity UL exercises would be hyperbolic10-14. In addition, little is known about the relationship between the parameters describing the W-t relationship for UL and other aerobic fitness indicators10.

There are significant differences in maximum and submaximal physiological responses to LL exercises, in comparison with exercises that use a smaller amount of muscle mass (notably UL exercises), have already been described15-18. Furthermore, LL ergometers are a useful tool for assessing and training individuals with functional limitation of LL movements, or for lung disease and cardiac patients, thereby assisting in the process of cardiopulmonary rehabilitation19. In this light, the objectives of the present study were to analyze the power-duration relationship in constant load exercises performed in UL ergometer and to investigate the relationship between parameters that derive from this function and from physiological indicators of aerobic fitness. In addition, this study investigated whether CP for UL can be used as an assessment tool for the endurance and whether, in this type of activity, CP is associated with PTT and VO2peak.

Methods

The sample consisted of 10 young male adults (22 to 32 years of age) with no orthopedic restrictions on performing UL exercises. They were classified as physically active, with scores ranging from 8 to 12 according to the Baecke, Burema and Frijters20 physical activity questionnaire. The study was conducted at the Stress Physiology Study Center (CEFE) after its approval by the Ethics Committee of the Federal University of São Paulo (UNIFESP) (040/00). The subjects were included only after they had signed an informed consent statement. A single physician performed a clinical examination on all subjects, composed of full anamnesis and general physical examination.

Anthropometric data on the subjects were obtained using calibrated scales (Filizola, Brazil), and the body mass index was calculated (Table 1). The subjects were then subjected to an incremental ramped test up to the limit of tolerance. The incremental ramping rate (20 W/min) was adjusted between the subjects so that the test duration would be between 4 and 10 minutes.

The metabolic, ventilatory and cardiovascular responses during the UL cycle ergometer test (MET 300, Cybex, Lumex, Ronkonkoma, NY, USA) were obtained via an integrated digital system for cardiopulmonary exercise tests (Vista CX, Vacumed, Hans Rudolph, USA). Metabolic and cardiopulmonary variables were obtained and sampled as arithmetic averages of values determined every 20 seconds. The gas analyzers were calibrated before each test by using a precise mixture of gases (16% O2 and 4% CO2). The flow meter was also calibrated before each test using a syringe with a preestablished volume of three liters (Wyandotte model 7200, Hans Rudolph, USA), with different flow settings (slow, moderate and fast). The following variables were determined: O2 uptake (VO2, l/min STPD); carbon dioxide production (VCO2 l/min STPD); respiratory quotient (R); minute ventilation (VE, l/min BTPS); respiratory equivalent for O2 and CO2 (VE/VO2 and VE/VCO2); partial pressure of O2 and CO2 (PO2 and PCO2, mmHg) and heart rate (HR, bpm). The VO2 of the final last 20 seconds of the ramp was considered to be the VO2peak. The VT1 VO2 was estimated by means of the pulmonary gas exchange method, using readings of the VCO2 inflection point in relation to VO2 (modified V-slope)21 and using the ventilator method. In this, both VE/VO2 and PO2 increased, while VE/VCO2 and PCO2 remained stable. To determine VT1, two regions were excluded from the analysis: the initial two minutes of the protocol, when slower VCO2 kinetics affect the relationships of pulmonary gas exchange, and the points beyond the respiratory compensation point (RCP)22. The readings were performed independently by two experienced observers who did not know the identity of the subject under evaluation, or the other results relating to this subject. Taking into account that, for rapid-increment protocols, the load corresponding to the VO2 point values is the one that was developed during the preceding time constant23, the VT1 load was considered to be the one manifested 45 seconds prior to the VO2 that was associated with VT121. VT2 was identified by determining the point at which a progressive increase in the equivalent VE/VCO2 occurred, with a drop in PCO2 and/or a second abrupt increase in VE after VT1, plotted as a function of VCO2.

Subsequently, each subject underwent a set of five different constant load tests performed up to the limit of tolerance: each test was taken on a different day in a randomized sequence. The protocol was composed of five rectangular loading functions, with a minimum interval of three days between loads. The aim was to provide better graphic distribution and greater validity for the CP and anaerobic work capacity findings3. Loads were selected based on the results from the incremental test and they corresponded to approximately 70, 80, 90, 95 and 100% of the difference found between the VT1 load and VO2peak (VT1 - MAX). Workloads that could induce exhaustion before reaching one minute or after a duration of 20 minutes were deliberately avoided3. In addition, all the subjects were also tested with a load equivalent to the intercept of the W-1/t relationship. In this load, VO2 behavior was measured by determining the VO2 CP, through identifying the time at which VO2 stabilized. This was found to be between 5 and 10 minutes for all subjects.

Finally, all the subjects underwent an additional test at a load that was 5% greater than the load equivalent to the intercept of the W-1/t relationship. Neither the subjects nor the investigator were informed of the duration of the test or the power that they should develop. The subjects received encouragement from the investigator, to ensure that they would perform the test to the best of their abilities.

The tests were performed with the subjects maintaining a cycling frequency of 80 rpm, in accordance with a preestablished protocol for UL ergometry24,25. All the tests were preceded by three minutes under baseline resting conditions and two minutes of load-free exercise, during which the ventilatory and metabolic parameters were verified. The time taken to reach fatigue was determined as the interval between the imposition of the load and the point at which the subject could not maintain the required pace of cycling (drop greater than 10%).

The W-t relationship was linearized by means of a load (in watts) versus the reciprocal of time (1/t), i.e.:

W=W'/t+PC

Therefore, the curvature constant (W', in kJ) and its asymptote (PC, in W) were determined from the slope and the intercept, respectively, of the line obtained from the difference between least squares26.

Statistical analysis

After verifying that the variables presented normal distribution (Kolmogorov-Smirnov test), the means and the standard deviations were identified. The mean values were compared using one-way ANOVA for paired samples. The levels of association between CP, VT1, VT2 and VO2peak were determined using the Pearson correlation test. For all tests, significance level of 5% (α=0.05) was established.

Results

The relationship between the power applied and its respective time duration (W-t) was described by a rectangular hyperbolic function for all assessed subjects, with the following values: CP=103±26 W; W´=7.08±2.14 kJ; and r=0.98±.02. Table 2 shows the values found for the study variables from the progressive test and in relation to CP.

The value of VO2 at CP (VO2CP) was significantly greater than the values found for VT1 (P<0.001) and VT2 (p<0.05) and lower than to VO2peak (p<0.05). No significant difference in W was found between CP and VT2. There were significant associations between the VO2 and W values at CP and between the values of these variables at peak effort, VT1 and VT2 (Table 3).

The volunteers continued to perform the rectangular loading test corresponding to CP for 42.9±12.9 minutes. One subject (10%) could not complete 30 minutes of exercise at CP, reaching fatigue after 20 minutes of exercise. The other subjects tolerated at least 30 minutes in the rectangular test. However, at the load that was 5% greater than CP, the subjects reached fatigue after 13.7±1.4 min (range: 11.7 to 16.0 min).

Discussion

There has been a series of discussions regarding the mathematical model that would best represent the relationship between W and t26, the number of loads that would be ideal for composing the distribution of points on the W versus t graph3 and the amount of time for which a CP load would be bearable. The high r values for all subjects demonstrated that by using the reciprocal of time, the relationship was properly linearized with a hyperbolic function. The findings from the present study emphasize that, similar to LL exercises, the relationship between W and t for UL exercises is hyperbolic (with r values ranging from 0.94 to 1.00; p<0.01). This assertion can be seen from the high r values that were found through linearization of the relationship between W and the inverse of time duration (1/t), in accordance with previous observations made by other authors in LL-related research2,9.

VO2max is an aerobic index that, when measured during UL exercises, presents values that are around two thirds of the values obtained during LL exercises among healthy individuals27. The smaller muscle mass of the UL can cause localized fatigue and cause exercises to be interrupted before the maximum cardiac output is reached. This is why the parameter is named VO2peak, regardless of whether a plateau is reached21.

Loads that led to CP were calculated as fractions of the difference between maximum power and VT1. VO2PC and VO2peak were associated (r=0.73; p<0.05), with significant differences between the parameters, of 2.66±0.617 l/min and 3.06±0.619 l/min, respectively. VO2CP was also significantly greater and correlated with VO2VT1 (1.621±0.378 l/min; r=0.76) and VO2VT2 (2.36±0.587 l/min; r=0.78). The same trend was observed among the loads of these variables, with greater association values found between them (Table 2). These results suggest that the nature of CP is predominantly aerobic, as previously reported28,29. Reinforcing this model, W´ did not correlate significantly to any of the aerobic parameters used (r=0.04-0.25). This result suggests that these indexes provide different metabolic representations.

VT2 was calculated from the behavior of ventilatory variables during the ramp protocol. At submaximal intensities, this usually reveals VO2 values that are lower than those obtained in rectangular loading functions of longer duration, i.e. over five minutes, like the VO2CP measurement that was used in this study. The phenomenon that explains this discrepancy between protocols is the small component of the VO2 kinetics that occurs above VT1. This makes VO2 dependent not only on load but also on the duration of the exercise, which can determine different levels of stress when assessing these variables8.

The associations found between CP and VT1 and VT2 are in agreement with data for UL found by Moritani et al.30. Among well-trained young students, Dekerle et al.8 found that CP was greater than VT1 and similar to VT2, with non-significant associations between CP and VT1 (r=-0.08) and LV2 (r=0.07). In contrast to these results, Dekerle et al.8 demonstrated that the intensity at CP was similar to the VT1 intensity, while Nakamura et al.14 found that CP was significantly greater than VT1 (r between 0.86 and 0.93) and smaller than VT2 (r between 0.79 and 0.85). These conflicts relating to the physiological domain of CP can be extended to comparisons with the intensity of maximum lactate steady state (MLSS)8. Although a high level of association was found between these variables (r=0.95), it has been demonstrated that CP is greater in intensity or that no significant differences occur between these variables31. Moreover, it was not possible to find a steady state of blood lactate concentration [la] in rectangular loadings at CP, despite the similarity with the intensity of MLSS at VO26,32 and perceived exertion14.

Factors related to costs and the small numbers of laboratories that perform ergospirometry tests using UL ergometers hinder and sometimes even prevent physical therapists from prescribing appropriate exercises during cardiopulmonary rehabilitation programs. Methodologically, CP determination and its use as an estimate of the MLSS is advantageous for physical therapists who prescribe UL exercises during cardiopulmonary rehabilitation programs. It is easy and feasible to apply CP determinations, and to produce valid information for monitoring aerobic endurance ability and the individual response to training, while avoiding, for instance, problems of estimation based strictly on blood lactate values33. However, it should be noted that the results from the present study did not make it possible to establish whether CP corresponds to a greater metabolic need associated with steady lactate. Even though it was verified that VO2 stabilized under constant loading at CP, no direct measurements of lactate were made, either at this or at other, lower or higher loads. Nonetheless, the mean time duration at CP was 42.9±12.9 min (minimum of 20 min). None of the subjects maintained the load of 5% above CP for more than 20 minutes (13.7±1.4 min), which favors the use of CP as an approximation for the intensity of the MLSS in UL exercises. Regardless of the way in which CP is expressed, it appears to belong to a transition zone between intense and very intense domains.

Regarding the CP load, the value found for the pulmonary exchange rate was 0.98±0.02, which corresponded to an intensity predominantly from the use of energy from carbohydrate metabolism34. Over a period of time sustaining this load, this energy path is progressively depleted, and its depletion may be the main cause of fatigue. From the time taken to reach exhaustion and the features of the UL exercises practiced at intensities higher than CP, the main reason for terminating the exercises was correlated with increases in metabolic acidosis.

Future investigations with larger samples and involving the W-t relationship for UL exercises should be performed using different protocols, cycling paces and interruption criteria. They should also include the use of analogue scales of perceived effort and located electromyography10,11,24,35, particularly emphasizing additional studies on the relationship between the maximum lactate steady accumulation rate and CP.

The power applied and the respective duration of a tolerance relationship for high-intensity dynamic UL exercises were characterized by a rectangular hyperbolic function. The y asymptote of this relationship (CP) represented a load similar to VT2, which was likely to be sustained for a prolonged period of time and with t similar to the one commonly found in LL. CP was significantly associated with indicators of aerobic metabolism, such as VO2peak, VT1 and VT2.

  • 1. Bosquet L, Léger L, Legros P. Methods to determine aerobic endurance. Sports Med. 2002;32(11):675-700.
  • 2. Monod H, Scherrer J. The work capacity of a synergic muscle group. Ergonomics. 1965;8:329-38.
  • 3. Hill DW. The critical power concept : a review. Sports Med. 1993;16(4):237-54.
  • 4. Neder JA, Jones PW, Nery LE, Whipp BJ. The effect of age on the power/duration relationship and the intensity-domain limits in sedentary men. Eur J Appl Physiol. 2000;82(4):326-32.
  • 5. Willians CA, Dekerle J, McGawley K, Berthoin S, Carter H. Critical power in adolescent boys and girls - an exploratory study. Appl Physiol Nutr Metab. 2008;33(6):1105-11.
  • 6. Hill DW, Smith JC. Determination of Critical Power by Pulmonary Gas Exchange. Can J Appl Physiol. 1999;24(1):74-86.
  • 7. Whipp BJ, Ozyener F. The kinetics of exertional oxygen uptake: assumption and inferences. Med Sport. 1998;51:139-49.
  • 8. Dekerle J, Baron B, Dupont L, Vanvelcenaher J, Pelayo P. Maximal lactate steady state, respiratory compensation threshold and critical power. Eur J Appl Physiol. 2003;89(3-4):281-8.
  • 9. Neder JA, Jones PW, Nery LE, Whipp BJ. Determinants of the exercise endurance capacity in patients with COPD: the power-duration relationship. Am J Respir Crit Care Med. 2000;162(2Pt 1):497-504.
  • 10. Vanhatalo A, Doust JH, Burnley M. Determination of critical power using a 3-min all-out cycling test. Med Sci Sports Exerc. 2007;39(3):548-55.
  • 11. Capodaglio P, Bazzini G. Predicting endurance limits in arm cranking exercise with a subjectively based method. Ergonomics. 1996;39(7):924-32.
  • 12. Calis JFF, Denadai BS. Influência das cargas selecionadas na determinação da potência crítica determinada no ergômetro de braço em dois modelos lineares. Rev Bras Med Esporte. 2000;6:1-4.
  • 13. Taylor SA, Batterham AM. The reproducibility of estimates of critical power and anaerobic work capacity in upper body exercise. Eur J Appl Physiol. 2002;87(1):43-9.
  • 14. Nakamura FY, Borges TO, Brunetto AF, Franchini E. Correlação entre os parâmetros do modelo de potência crítica no cicloergômetro de membros superiores e no caiaque. Rev Bras Ciên Mov. 2005;13(2):41-8.
  • 15. Celli BR. The clinical use of upper extremity exercise. Clin Chest Med. 1994;15(2):339-49.
  • 16. Kang J, Chaloupka EC, Mastrangelo MA, Angelucci J. Physiological responses to upper body exercise on an arm and a modified leg ergometer. Med Sci Sports Exerc. 1999;31(10):1453-9.
  • 17. Koppo K, Bouckaert J, Jones AM. Oxygen uptake kinetics during high-intensity arm and leg exercise. Respir Physiol Neurobiol. 2002;133(3):241-50.
  • 18. Calbet JAL, Holmberg H-C, Rosdahl H, van Hall G, Jensen-Urstad M, Saltin B. Why do arms extract less oxygen than legs during exercise? Am J Physiol Regul Comp Physiol. 2005;289:1448-58.
  • 19. Neder JA, Nery LE. Fisiologia Clínica do Exercício. Teoria e Prática. São Paulo: Artes Médicas; 2003.
  • 20. Baecke JA, Burema J, Frijters E. A short questionnaire for the measurement of habitual physical activity in epidemiological studies. Am J Clin Nutr. 1982;36(5):936-42.
  • 21. Wasserman K, Hansen JE, Sue DY, Whipp BJ, Casaburri R. Principles of exercise testing and interpretation. 2Ş ed. Philadelphia: Lea & Febiger; 1987.
  • 22. McArdle WD, Katch FI, Katch VL. Fisiologia do Exercício - energia, nutrição e performance humana. Rio de Janeiro: Guanabara Koogan; 1998.
  • 23. Ward SA, Blesovsky L, Russak S, Ashjian A, Whipp BJ. Chemoreflex modulation of ventilatory dynamics during exercises in humans. J Appl Physiol. 1987;63(5):2001-7.
  • 24. Hill DW, Ferguson CS. A physiological description of critical velocity. Eur J Appl Physiol Occup Physiol. 1999;79(3):290-3.
  • 25. Franklin BA. Exercise testing training and arm ergometry. Sports Med. 1985;2(2):100-19.
  • 26. Bull AJ, Housh TJ, Johnson GO, Perry SR. Effect of mathematical modeling on the estimation of critical power. Med Sci Sports Exerc. 2000;32(2):526-30.
  • 27. strand PO, Rodahl K, Dahl HA, Stromme SB. Textbook of work physiology. 4Ş ed. Champaign: Human Kinetics; 2003.
  • 28. Wakayoshi K, Ikuta K, Yoshida T, Udo M, Moritani T, Mutoh Y, et al. Determination and validity of critical velocity as an index of swimming performance in the competitive swimmer. Eur J Appl Physiol Occup Physiol. 1992;64(2):153-7.
  • 29. Fawkner SG, Armstrong N. Assessment of critical power with children. Pediatr Exerc Sci. 2002;14:259-68.
  • 30. Moritani T, Nagata A, deVries HA, Muro M. Critical power as a measure of physical work capacity and anaerobic threshold. Ergonomics. 1981;24(5):339-50.
  • 31. Smith CG, Jones AM. The relationship between critical velocity, maximal lactate steady-state velocity and lactate turnpoint velocity in runners. Eur J Appl Physiol. 2001;85(1-2):19-26.
  • 32. Barker T, Poole DC, Noble ML, Barston TJ. Human critical power-oxygen uptake relationship at different pedalling frequencies. Exp Physiol. 2006;91(3):621-32.
  • 33. Cligeleffer A, McNaughton LR, Davoren B. The use of critical power as a determinant for stablishing the onset of blood lactate accumulation. Eur J Appl Physiol Occup Physiol. 1994;68(2):182-7.
  • 34. Billat VL, Sirvent P, Py G, Koraltzen J-P, Mercier J. The concept of maximal lactate steady state. A bridge between biochemistry, physiology and sport science. Sports Med. 2003;33(6):407-26.
  • 35. Morton RH. Critical power test for ramp exercise. Eur J Appl Physiol Occup Physiol. 1994;69(5):435-8.
  • Determination of the power-duration relationship in upper-limb exercises

    Domingos Belasco JuniorI; Fernando R. OliveiraII; José A. N. SerafiniIII; Antonio C. SilvaIV
  • Publication Dates

    • Publication in this collection
      13 Oct 2011
    • Date of issue
      Aug 2010

    History

    • Received
      03 Mar 2009
    • Accepted
      27 Oct 2009
    • Reviewed
      14 Sept 2009
    Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia Rod. Washington Luís, Km 235, Caixa Postal 676, CEP 13565-905 - São Carlos, SP - Brasil, Tel./Fax: 55 16 3351 8755 - São Carlos - SP - Brazil
    E-mail: contato@rbf-bjpt.org.br