Open-access Comparing bleeding pattern and dysmenorrhea with the Levonorgestrel 52mg and 19.5mg intrauterine systems during the first year of use

Abstract

Objective:  To compare the bleeding pattern and dysmenorrhea relief between patients using 52mg LNG-IUS and 19.5mg LNG-IUS during the first year, and to investigate a dose-dependent correlation.

Methods:  A prospective cohort study was conducted, which followed-up women using LNG-IUS over the first year. A total of 368 52mg LNG-IUS and 385 19.5mg LNG-IUS were surveyed at a private clinic. Insertion of the devices was performed by the same attending physician, in an outpatient setting, in a one-year period. Bleeding patterns and dysmenorrhea relief were analyzed by 90-day reference periods, using the WHO Belsey criteria for bleeding and the visual analog scale for pain. Data of infrequent, frequent, prolonged, and irregular bleeding rates, as well as amenorrhea rates, were compared using Fisher exact testing.

Results:  Analysis of bleeding data showed that there was not a dose-dependent interaction for a better pattern over 12 months. However, the lower dose LNG-IUS seems to reach a favorable bleeding pattern faster when compared to the higher dose device (p=0.003). Also, the analysis of dysmenorrhea relief showed that there was a dose-dependent result in action speed: higher dose device was faster (p<0.001). Nevertheless, when looking by the end of the first year, there was no significant difference.

Conclusion:  19.5mg LNG-IUS seems to reach faster a favorable bleeding pattern and more slowly a dysmenorrhea relief when compared to 52mg LNG-IUS. There is no significant difference between these two systems by the end of the first year.

Keywords
Uterine bleeding; Dysmenorrhea; Levonorgestrel; Intrauterine devices

Introduction

Unplanned pregnancy is a public health problem, which affects millions of women worldwide. Providing long-acting reversible contraceptive (LARC) methods is an excellent strategy to avoid or at least reduce this situation, because the effectiveness of these methods is higher than other methods, indeed comparable to that of permanent contraception.(1)

The levonorgestrel-releasing intrauterine system (LNG-IUS) is a highly effective LARC method and many women go on to experience progressively lighter bleeding over the years of use. However, irregular bleeding due to the local effect of levonorgestrel on the endometrium is common, particularly during the adaptation period, as seen in all progestogen-isolated methods.(2)

This topic is relevant because, although discontinuation rates due to bleeding changes (including amenorrhea) are low in clinical trials, several studies show that bleeding pattern and side effects changes impact on LARC continuation.(3) But is there a dose-dependent correlation in achieving a better bleeding pattern and dysmenorrhea relief? There are controversial studies in the literature that sometimes Higher doses of progestogens appear to bring about a more favorable bleeding pattern

The objective of this research was to compare the bleeding pattern of patients using 52 mg LNG-IUS and 19.5 mg LNG-IUS during the first year of use, as well as the improvement in pain / dysmenorrhea of women using these two hormonal devices.

Methods

This prospective analysis looks at the changes in bleeding patterns and relief of dysmenorrhea when using two different doses of levonorgestrel intrauterine systems over their first year of use. Insertion of the IUDs was performed by the same attending physician, Professor at the Medicine School, in an outpatient setting, in a one-year period.

Women in reproductive years, who had already started sexual activity and wanted an effective long-term contraceptive method, were included in the study, excluding patients with secondary dysmenorrhea (mainly when there was a previous diagnose for that, as endometriosis), abnormal uterine bleeding (these factors are assessed during the medical history taking, characterizing the normal bleeding pattern in terms of regularity, frequency, duration, and menstrual flow), patients after bariatric surgery and any other hormonal IUD therapeutic indication other than for the sole purpose of contraception. They were presented for both options of intrauterine devices, as many only knew about 52 mg LNG-IUS, and the criteria for choosing 52 vs. 19.5 consisted in the desire by the user, even with reinforcement from the authors regarding the current indications of contraception for the 19.5 mg device, and of therapy for the higher dosage device. At the time of counseling, both devices were found to have a contraceptive effectiveness duration of 5 years, and the patient's direct choice between the models was respected.

Bleeding patterns were analyzed by 90-day reference periods for the first year. Ninety days was chosen as the reference period to provide detail of the changes in bleeding after LNG-IUS placement because the definition of amenorrhea relates only to 90-day reference periods where bleeding and spotting are absent. Patients were encouraged to keep a menstrual diary, noting any symptoms/discomfort, in order to facilitate communication during quarterly in-person assessments carried out by the authors.

The authors assessed bleeding patterns using the WHO Belsey criteria,(4) over reference periods. To estimate dysmenorrhea relief, the visual analog scale (VAS), due to its easy applicability, was used.

As there are approximately 26 million women electable for contraception, and 1,5% of them are using IUDs in Brazil,(5) the calculation of sample N resulted in 246 patients, with a 95% confidence level.

For statistical analysis, the patients’ baseline characteristics were evaluated as a percentage or mean plus standard deviation. Infrequent, frequent, prolonged, and irregular bleeding rates, as well as amenorrhea rates, over the first year for women using levonorgestrel 52 mg and 19.5 mg IUS, were also expressed in absolute number and percentage. Fisher's exact testing was used for comparisons of proportions with p-values ≤ 0.05 considered significant at 90-day reference periods.

Ethics approval was granted by the Research Ethics Committee of the Pontifical Catholic University of Paraná under number CAAE 61717522.7.0000.0020 (protocol 5.613.181). All patients were previously instructed and signed the Free and Informed Consent Form for the research.

Results

Study population

A total of 368 52 mg LNG-IUS users and 385 19.5 mg LNG-IUS users were included in the research – all of the patients recruited for the research (with active follow-up being conducted when necessary). In the 12-month pooled analysis of data, it was possible to compare the results of 364 and 383 patients at the first and second groups respectively. This is due to an expulsion of one 52 mg LNG-IUS, that occurred during the first month of use, and five women that discontinued use of the LNG-IUS because of bleeding problems (including absence of bleeding) by the end of the first year (3 at the group of the higher dose device and 2 at the lower one). The baseline characteristics of the participants are summarized in table 1.

Table 1
Baseline characteristics of the patients

Regarding dysmenorrhea, 251 (68%) patients in 52 mg LNG-IUS group reported experiencing menstrual cramps in at least one cycle in the 90 days prior to insertion of the intrauterine device, with an average pain intensity of 56±4 (VAS 0-100), while in 19.5 mg LNG-IUS group, 265 (69%) had the same complaint with an average pain intensity of 55±8 (VAS 0-100).

Impact of levonorgestrel dose on bleeding patterns

Analysis of bleeding and/or spotting data with the 52 and 19.5 mg LNG-IUS showed that there was not a dose-dependent proportion of women with a better bleeding pattern over 12 months. When looking at the proportion of women with a low number of bleeding and/or spotting days, including women with 0 days (amenorrhea), during the first year of use, the differences between both systems was not significant. Table 2 compares amenorrhea rates between users of the levonorgestrel 52 mg and 19.5 mg IUS. Amenorrhea was uncommon in the first 90 days for both IUS doses and increased over time. During the second 90-day reference period, amenorrhea rates in levonorgestrel 19.5 mg users were slightly higher than the rates in levonorgestrel 52 mg, however, no statistical difference was observed during all the 12-months period.

Table 2
Amenorrhea rate over the 1st year for women using levonorgestrel 52 mg and 19.5 mg IUS

The table 3 compares infrequent, frequent, prolonged, and irregular bleeding pattern rates reported for levonorgestrel 52 mg and 19.5 mg IUS users. All four bleeding patterns studied were statistically equal at the end of the first year of patients’ follow-up. However, infrequent bleeding increased more quickly, and irregular bleeding rates declined faster for women using 19.5 mg LNG-IUS, despite its similarity in the first 90 days of use, and this was significantly different. Frequent and prolonged bleeding were uncommon patterns for users of both IUS doses by the end of the 12 months.

Table 3
Infrequent, frequent, prolonged, and irregular bleeding rates over the 1st year for women using levonorgestrel 52 mg and 19.5 mg IUS

As shown on figure 1, the authors noticed that despite the similarity at the end of the first year, the lower dose LNG-IUS seems to reach faster a favorable bleeding pattern when compared to the higher dose device.

Figure 1
Unfavorable bleeding patterns over the 1st year for women using levonorgestrel 52 mg and 19.5 mg IUS

Impact of levonorgestrel dose on dysmenorrhea

Analysis of dysmenorrhea relief data with the 52 and 19.5 mg LNG-IUS showed that there was a dose-dependent result in action speed: higher dose device was faster in relieve pain (mean visual analog scale (VAS) at the 4 studied period for 52 mg LNG-IUS 72±8 / 35±11 / 29±8 / 26±4 versus 19.5 mg LNG-IUS 71±9 / 61±10 / 44±7 / 27±4). As shown at the data by elevation of the mean VAS, patients reported worsening of dysmenorrhea in the first post-insertion cycles. When looking at the proportion of women with dysmenorrhea relief, during the first year of use, the differences between both systems was not significant, as seen in figure 2.

Figure 2
Visual analog scale (VAS) of dysmenorrhea over the 1st year for women using levonorgestrel 52 mg and 19.5 mg IUS

Discussion

Although the molecular mechanisms are incompletely understood, the LNG-IUS proved to be effective in primary, and some cases of secondary, dysmenorrhea and in reducing uterine bleeding.(6) Nelson et al. showed in their study that vaginal bleeding patterns were found to be acceptable by more than three fourths of women using the devices regardless of levonorgestrel's dose. Over their entire study duration, less than 4.9% of women using low-dose LNG-IUS discontinued because of bleeding changes. The number of bleeding and spotting days declined over time, and there were more spotting days than bleeding days in all reference periods.(7)

In this prospective research the authors have found that women using any dose levonorgestrel IUS had very similar bleeding pattern and dysmenorrhea relief by the end of the first year of use. This is similar to that found by Beckert et al who showed that the majority of women experienced a progressive decline in the number of bleeding and/or spotting days and the number of bleeding episodes in the 12 months after placement of the 19.5mg LNG-IUS. Important to remember that they also demonstrated that when looking at the proportion of women with a low number of bleeding and/or spotting days, including women with amenorrhea, per month, the differences between different IUDs declined over time.(8)

Differently from what was observed by Goldthwaite and Creinin that, despite seeing equal frequent and prolonged bleeding pattern rates over the first 2 years, had noticed a better favorable pattern in patients using 52 mg LNG-IUS,(9) these authors saw similarity in both IUDs users by the end of the first year of use, but reaching it faster in 19.5 mg LNG-IUS. One possible reason for finding advantages to the lower dose device, explained by physiology, is that progesterone is central in endometrial remodeling and acts on both the epithelial and stromal compartments. Since a progestogen is the major active agent within LNG-IUS, and since the action of progesterone/progestogens is mediated through progesterone receptors (PRs), the ultimate efficacy of the LNG-IUS in bleeding control cinges critically on the expression levels of PRs, particularly PR isoform B in the endometrium. This action is related to the decrease in the expression of the Estrogen Receptor (ER), which interferes in the activity of this steroid - the main agent in controlling the menstrual cycle.(10) This hypothesis also supports why the amenorrhea rate of the lower dose was similar of that observed in higher dose LNG-IUS, found by the authors.

Moreover, the progestogen released by the LNG-IUS changes the prostaglandin ratio by stimulating arachidonic acid formation in the endometrium in favor of endometrial repair and thus less bleeding, reason why by the time they get equal.(11)

With regard to dysmenorrhea, there is consensus that progestogen can reduce pain. The search showed that higher dose IUS was faster in dysmenorrhea relief, compatible with what physiology brings us. The progestogens contained in the LNG-IUS can suppress uterine contractility, removing one important irritant that contributes to dysmenorrhea. Progestogens can also activate progesterone receptors in the myometrium, antagonizing nuclear factor kappalight-chain-enhancer of activated B cells (NF-κB) and thus reducing inflammation, removing another contributor to dysmenorrhea. As an added bonus for less or absent menstrual bleeding, there is less platelet aggregation and reduced or attenuated thrombin activation, which may further hinder uterine contractions.(12) It is important to remember that levonorgestrel also has a more powerful anti-inflammatory effect on the endometrium than other prostaglandin.(13)

Gemzell-Danielsson et al. had already saw that women using low-dose LNG-IUS generally experienced less frequent bleeding over time, similarly to high-dose ones. In their research, this trend was not owing to discontinuations due to bleeding problems, which were very low (5.2%). The greatest reduction in dysmenorrhea (occurring during the first 6 months of LNG-IUS) coincided with the greatest reductions in bleeding.(14)

The European TANCO study reported that almost two-thirds of women regarded reduced bleeding intensity as an important attribute of a contraceptive method. Almost three quarters of physicians also recognized this as important to women. Studies also show that clear counselling on what bleeding changes may be expected should be an important part of a woman's decision-making process, and managing expectations may help with method continuation. Although the possibility of bleeding changes is included in both LNG-IUS prescribing information, this research equips doctors with detailed information they can use when counselling women about what to expect regarding the timing and duration of bleeding and pain changes. It may also be helpful in managing expectations of those women who experience more prolonged bleeding in the first few weeks and present with concerns about continued use.(15,16)

Further insights into the aspects of bleeding that women may find most useful, i.e., in terms of number and duration of bleeding days or episodes or regularity of those episodes and how they would like to access this information, would help to assess the utility of these data. The studies described in this article show that some women continue to experience bleeding problems. Awareness of the importance of clinical assessment for structural pathology or bleeding disorders that may play a role must not be overlooked. Agents that help in the treatment of abnormal uterine bleeding when using long-acting reversible contraception will always be important to avoid discontinuing the method. However, the authors conclude from this research that the bleeding pattern of patients using 19.5 is similar to 52 (the latter highly praised by attending physicians in the control of uterine bleeding).

This study has some strengths, including the specific objective of evaluating two practical doubts of the attending physician (bleeding pattern and dysmenorrhea), which allowed a faithful analysis of the data reported by the patients; most of the research evaluates side effects among several other data. Furthermore, the prospective design allowed the use of facilitators, such as a menstrual diary, for better data analysis.

However, one inherent weakness of this study is the number of participants, relatively small when analyzing hormonal contraception. This might be explained by another important limitation in this publication which consists in the fact that LNG-IUS in Brazil is not provided in public health, but only in private care. That might limit the transferability of the results to a particular context in other countries. Another limitation of the study is the lack of randomization between groups, which could lead to selection bias. For the comparison envisioned by the authors, it was necessary in contraceptive counseling to allow the patient to choose the device to be used, given that the research was conducted in the private healthcare system in Brazil.

Conclusion

The LNG-IUS is well known to be an effective method of contraception, associated with high levels of satisfaction among women of all age groups. Detailed analysis of changes in bleeding patterns and dysmenorrhea relief during the first year, adaptation time to long-acting reversible contraceptive methods, will prove useful to physicians when counselling women about method choice and continuation. In this research, the similarity of action of both devices was proven by the end of the first year, with advantage of 19.5 mg LNG-IUS in the speed of reaching a favorable bleeding pattern and of 52 mg LNG-IUS in the speed of dysmenorrhea reduction. This reinforces the indication of the lowest dose for contraception, and the highest dose when there is a therapeutic need, both being similar after the adaptation period.

Data availability:

The research data are described in the article presented.

Acknowledgements

This publication and its content are the sole responsibility of the authors. The authors would like to acknowledge the contributions of Professor Gerson Righetto Junior, who reviewed the clinical interpretation of the results.

References

  • 1 Bahamondes L, Fernandes A, Monteiro I, Bahamondes MV. Long-acting reversible contraceptive (LARCs) methods. Best Pract Res Clin Obstet Gynaecol. 2020;66:28–40. doi: 10.1016/j.bpobgyn.2019.12.002
    » https://doi.org/10.1016/j.bpobgyn.2019.12.002
  • 2 Nelson AL. LNG-IUS 12: a 19.5 levonorgestrel-releasing intrauterine system for prevention of pregnancy for up to five years. Expert Opin Drug Deliv. 2017;14(9):1131–40. doi: 10.1080/17425247.2017.1353972
    » https://doi.org/10.1080/17425247.2017.1353972
  • 3 Runyan A, Welch RA, Kramer KJ, Cortez S, Roberts LJ, Asamoah C, et al. Long-Acting Reversible Contraception: Placement, Continuation, and Removal Rates at an Inner-City Academic Medical Center Clinic. J Clin Med. 2021;10(9):1918. doi: 10.3390/jcm10091918
    » https://doi.org/10.3390/jcm10091918
  • 4 Belsey EM, Machin D, d’Arcangues C. The analysis of vaginal bleeding patterns induced by fertility regulating methods. World Health Organization Special Programme of Research, Development and Research Training in Human Reproduction. Contraception. 1986;34(3):253–60. doi: 10.1016/0010-7824(86)90006-5
    » https://doi.org/10.1016/0010-7824(86)90006-5
  • 5 Brasil. Ministério da Saúde (BR). Secretaria da Ciência, Tecnologia e Insumos Estratégicos, Departamento de Ciência e Tecnologia. PNDS: 2006: Pesquisa Nacional de Demografia e Saúde da Criança e da Mulher: Relatório. Brasília; 2008. [citado 2026 Jun 26]. Disponível em: : http://bvsms.saude.gov.br/bvs/publicacoes/pnds_crianca_mulher.pdf
    » http://bvsms.saude.gov.br/bvs/publicacoes/pnds_crianca_mulher.pdf
  • 6 Bianchi P, Guo SW, Habiba M, Benagiano G. Utility of the Levonorgestrel-releasing intrauterine system in the treatment of abnormal uterine bleeding and dysmenorrhea: a narrative review. J Clin Med. 2022;11(19):5836. doi: 10.3390/jcm11195836
    » https://doi.org/10.3390/jcm11195836
  • 7 Nelson A, Apter D, Hauck B, Schmelter T, Rybowski S, Rosen K, et al. Two low-dose levonorgestrel intrauterine contraceptive systems: a randomized controlled trial. Obstet Gynecol. 2013;122(6):1205–13. doi: 10.1097/AOG.0000000000000019
    » https://doi.org/10.1097/AOG.0000000000000019
  • 8 Beckert V, Ahlers C, Frenz AK, Gerlinger C, Bannemerschult R, Lukkari-Lax E. Bleeding patterns with the 19.5 mg LNG-IUS, with special focus on the first year of use: implications for counselling. Eur J Contracept Reprod Health Care. 2019;24(4):251–9. doi: 10.1080/13625187.2019.1630817
    » https://doi.org/10.1080/13625187.2019.1630817
  • 9 Goldthwaite LM, Creinin MD. Comparing bleeding patterns for the levonorgestrel 52 mg, 19.5 mg, and 13.5 mg intrauterine systems. Contraception. 2019;100(2):128–31. doi: 10.1016/j.contraception.2019.03.044
    » https://doi.org/10.1016/j.contraception.2019.03.044
  • 10 Thomas C, Gustafsson JÅ. Progesterone receptor-estrogen receptor crosstalk: a novel insight. Trends Endocrinol Metab. 2015;26(9):453–4. doi: 10.1016/j.tem.2015.08.002
    » https://doi.org/10.1016/j.tem.2015.08.002
  • 11 Katzenellenbogen BS. Mechanisms of action and cross-talk between estrogen receptor and progesterone receptor pathways. J Soc Gynecol Investig. 2000;7(1 Suppl):S33–7. doi: 10.1177/1071557600007001S10
    » https://doi.org/10.1177/1071557600007001S10
  • 12 Bernardi M, Lazzeri L, Perelli F, Reis FM, Petraglia F. Dysmenorrhea and related disorders. F1000 Res. 2017;6:1645. doi: 10.12688/f1000research.11682.1
    » https://doi.org/10.12688/f1000research.11682.1
  • 13 Goldstuck ND. Modern menstruation: is it abnormal and unhealthy? Med Hypotheses. 2020;144:109955. doi: 10.1016/j.mehy.2020.109955
    » https://doi.org/10.1016/j.mehy.2020.109955
  • 14 Gemzell-Danielsson K, Apter D, Dermout S, Faustmann T, Rosen K, Schmelter T, et al. Evaluation of a new, low-dose levonorgestrel intrauterine contraceptive system over 5 years of use. Eur J Obstet Gynecol Reprod Biol. 2017;210:22–8. doi: 10.1016/j.ejogrb.2016.11.022
    » https://doi.org/10.1016/j.ejogrb.2016.11.022
  • 15 Merki-Feld GS, Caetano C, Porz TC, Bitzer J. Are there unmet needs in contraceptive counselling and choice? Findings of the European TANCO Study. Eur J Contracept Reprod Health Care. 2018;23(3):183–93. doi: 10.1080/13625187.2018.1465546
    » https://doi.org/10.1080/13625187.2018.1465546
  • 16 Machado RB, Ushikusa TE, Monteiro IM, Guazzelli CA, di Bella ZJ, Politano CA, et al. Different Perceptions among Women and Their Physicians Regarding Contraceptive Counseling: results from the TANCO Survey in Brazil. Rev Bras Ginecol Obstet. 2020;42(5):255–65. doi: 10.1055/s-0040-1712145
    » https://doi.org/10.1055/s-0040-1712145

Corresponding author

Jan Pawel Andrade Pachnicki E-mail: janpawel@uol.com.br

Conflicts to interest:

none to declare.

Associate Editor

Rogério Bonassi Machado (https://orcid.org/0000-0001-9361-0905) Faculdade de Medicina de Jundiaí, Jundiaí, São Paulo, SP, Brazil

Publication Dates

  • Publication in this collection
    27 Nov 2026
  • Date of issue
    2026

History

  • Received
    19 Sept 2025
  • Accepted
    26 May 2026
location_on
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia Av. Brigadeiro Luís Antônio, 3421, sala 903 - Jardim Paulista, 01401-001 São Paulo SP - Brasil, Tel. (55 11) 5573-4919 - Rio de Janeiro - RJ - Brazil
E-mail: editorial.office@febrasgo.org.br
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top