Acessibilidade / Reportar erro

Localized muscle fatigue: review of three experiments

Fadiga muscular localizada: revisão de três estudos

Abstracts

Background: Fatigue considerably affects rehabilitation and ergonomics. Many approaches to this complex phenomenon, ranging from physiological to psychological, have been used to obtain meaningful fatigue measurements. However, none of the methods in the literature measure fatigue directly. It is therefore of considerable interest to determine which indirect methods best represent the state. Method: Fatiguing contraction was measured at maximum voluntary contraction (MVC) and 40% MVC in the biceps brachii, quadriceps and erector spinae muscles (three separate experiments). The most-reported objective measurements (contraction force, median electromyographic frequency, heart rate, muscle bed oxygenation and muscle blood volume) and subjective measurements (visual analog score, body part discomfort rating and perceived exertion rate) were simultaneously recorded. The data from the three experiments underwent separate statistical analysis. Descriptive statistics, linear mixed effects (to examine force fatigue predictability) and trend analysis (with between and within-subject correlations) were calculated. Results: Univariate ANOVA on all objective variables showed that gender was a significant factor (p<0.001). All subjective and objective variables were significant (p<0.050.001) in predicting force fatigue. However, the percentage variability explained remained small. By combining variables, the variability explained increase to between 60.2% and 71.9%. Correlations between variables were small but significant (p<0.050.001). Among single variables, median electromyographic frequency was a slightly better predictor of MVC fatigue (p<0.001) and visual analog score for sub-MVC (p<0.001). Conclusion: It is desirable not to measure or predict fatigue based on one variable alone. Combining variables improves measurement and prediction. Single-variable indexing of localized muscle fatigue is problematic.

fatigue; force; electromyography; visual analog score


Contexto: A fadiga afeta consideravelmente a reabilitação e ergonomia. Muitas abordagens a este fenômeno complexo, incluindo fisiológicas e psicológicas, têm sido utilizadas para obter medidas significativas da fadiga. No entanto, nenhum dos métodos descritos na literatura mede diretamente a fadiga. É, portanto de interesse a determinação de quais dos métodos indiretos melhor representa a condição de fadiga. Método: A fadiga por contração foi medida na contração voluntária máxima (CVM) e 40% da CVM em músculos bíceps braquial, quadríceps e músculos eretores da coluna (três avaliações independentes). As medidas objetivas mais relatadas (força de contração, freqüência mediana na eletromiografia, freqüência cardíaca, oxigenação do leito muscular e volume sangüíneo muscular) e as medidas subjetivas (escala visual analógica, avaliação de desconforto em partes do corpo e avaliação percebida do esforço) foram anotadas simultaneamente. Dados dos três estudos foram submetidos a análises estatísticas separadamente. Dados estatísticos descritivos, efeitos lineares mistos (para avaliar a previsibilidade da força de fadiga) e análise de tendências (correlação comparativa intra e extra indivíduos) foram calculadas. Resultados: ANOVA univariada em todas as variáveis objetivas mostraram que o sexo foi um fator importante (p<0,001). Todas as variáveis subjetivas e objetivas foram significantes (p<0,050,001) para predizer a força de fadiga. No entanto, as variações explicáveis de porcentagem permaneceram pequenas. Através da combinação de variáveis, a variabilidade explicável aumentou entre 60,2% e 71,9%. As correlações entre as variáveis foram pequenas, porém significativas (p<0,050,001). Entre as variáveis simples, a medida da freqüência da eletromiografia foi o fator preditivo um pouco melhor para fadiga CVM (p<0,001), assim como a escala visual analógica para sub-CVM. Conclusão: É desejável que não se meça ou prediga a fadiga com base em apenas uma variável. A combinação de variáveis melhora as medidas e predição da fadiga. Indexar uma variável simples na fadiga muscular localizada é portanto problemático.

fadiga; força; eletromiografia; escala visual analógica


REVIEW ARTICLES

Localized muscle fatigue: review of three experiments

Fadiga muscular localizada: revisão de três estudos

Kumar S

Ergonomics Research Laboratory, Department of Physical Therapy, University of Alberta, Edmonton, Canada

Corresponding author Corresponding author: Shrawan Kumar, Ergonomics Research Laboratory, Department of Physical Therapy, University of Alberta Edmonton, Canada T6G 2G4 e-mail: shrawan.kumar@ualberta.ca

ABSTRACT

Background: Fatigue considerably affects rehabilitation and ergonomics. Many approaches to this complex phenomenon, ranging from physiological to psychological, have been used to obtain meaningful fatigue measurements. However, none of the methods in the literature measure fatigue directly. It is therefore of considerable interest to determine which indirect methods best represent the state.

Method: Fatiguing contraction was measured at maximum voluntary contraction (MVC) and 40% MVC in the biceps brachii, quadriceps and erector spinae muscles (three separate experiments). The most-reported objective measurements (contraction force, median electromyographic frequency, heart rate, muscle bed oxygenation and muscle blood volume) and subjective measurements (visual analog score, body part discomfort rating and perceived exertion rate) were simultaneously recorded. The data from the three experiments underwent separate statistical analysis. Descriptive statistics, linear mixed effects (to examine force fatigue predictability) and trend analysis (with between and within-subject correlations) were calculated.

Results: Univariate ANOVA on all objective variables showed that gender was a significant factor (p<0.001). All subjective and objective variables were significant (p<0.050.001) in predicting force fatigue. However, the percentage variability explained remained small. By combining variables, the variability explained increase to between 60.2% and 71.9%. Correlations between variables were small but significant (p<0.050.001). Among single variables, median electromyographic frequency was a slightly better predictor of MVC fatigue (p<0.001) and visual analog score for sub-MVC (p<0.001).

Conclusion: It is desirable not to measure or predict fatigue based on one variable alone. Combining variables improves measurement and prediction. Single-variable indexing of localized muscle fatigue is problematic.

Key words: fatigue, force, electromyography, visual analog score.

RESUMO

Contexto: A fadiga afeta consideravelmente a reabilitação e ergonomia. Muitas abordagens a este fenômeno complexo, incluindo fisiológicas e psicológicas, têm sido utilizadas para obter medidas significativas da fadiga. No entanto, nenhum dos métodos descritos na literatura mede diretamente a fadiga. É, portanto de interesse a determinação de quais dos métodos indiretos melhor representa a condição de fadiga.

Método: A fadiga por contração foi medida na contração voluntária máxima (CVM) e 40% da CVM em músculos bíceps braquial, quadríceps e músculos eretores da coluna (três avaliações independentes). As medidas objetivas mais relatadas (força de contração, freqüência mediana na eletromiografia, freqüência cardíaca, oxigenação do leito muscular e volume sangüíneo muscular) e as medidas subjetivas (escala visual analógica, avaliação de desconforto em partes do corpo e avaliação percebida do esforço) foram anotadas simultaneamente. Dados dos três estudos foram submetidos a análises estatísticas separadamente. Dados estatísticos descritivos, efeitos lineares mistos (para avaliar a previsibilidade da força de fadiga) e análise de tendências (correlação comparativa intra e extra indivíduos) foram calculadas.

Resultados: ANOVA univariada em todas as variáveis objetivas mostraram que o sexo foi um fator importante (p<0,001). Todas as variáveis subjetivas e objetivas foram significantes (p<0,050,001) para predizer a força de fadiga. No entanto, as variações explicáveis de porcentagem permaneceram pequenas. Através da combinação de variáveis, a variabilidade explicável aumentou entre 60,2% e 71,9%. As correlações entre as variáveis foram pequenas, porém significativas (p<0,050,001). Entre as variáveis simples, a medida da freqüência da eletromiografia foi o fator preditivo um pouco melhor para fadiga CVM (p<0,001), assim como a escala visual analógica para sub-CVM.

Conclusão: É desejável que não se meça ou prediga a fadiga com base em apenas uma variável. A combinação de variáveis melhora as medidas e predição da fadiga. Indexar uma variável simples na fadiga muscular localizada é portanto problemático.

Palavras-chave: fadiga, força, eletromiografia, escala visual analógica.

INTRODUCTION

While the connotation of fatigue, in context, is easy to comprehend, its complexity in scientific domain is considerable. Fatigue, as it relates to human performance, is important from both physical and cognitive perspectives. Even in the physical domain, the nature of fatigue for the entire organism or a specific muscle is different. While the fatigue of organism may be described by the progressive reduction of reserve energy or the rate of its expenditures, a similar description for individual tissues is obscure. The organism fatigue can also be expressed by subjective measures, such as rate of perceived exertion¹. Individual tissues, such as connective tissues, can undergo mechanical fatigue as a result of prolonged or repetitive exertion. Muscles, on the other hand, generally undergo physiological and contractile fatigue. Whereas the experience of muscle fatigue has been wide spread, a universally valid method to determine it has not emerged.

A variety of methods have been used for measuring localized muscle fatigue. These fall under categories of objective and subjective methods. Objectively the most clear indication of fatigue is the duration for which a load can be held or decay in the force over time. The magnitude of force (strength) and duration it can be held (endurance) was initially demonstrated by Rohmert2. However, the ability to sustain a load or increase the level of strength is subjectively modifiable. Also despite the discomfort, people can maintain their contraction for a period longer than the endurance time, if motivated to do so. Thus the strength and endurance curve is obscured making it difficult to measure even force fatigue quantitatively.

Electromyography has been considered a reliable tool for an indication of localized muscle fatigue3,4. In recent years other authors have stated that the median frequency (MF) of the EMG power spectrum is sensitive to the physiological manifestation of fatigue5,6,7,8. The rate of decline of the MF during a sustained contraction was used by them as an index of muscle fatigue. An accompanying increase in EMG amplitude has also been considered a quantitative measure of fatigue5,6,9,10. Other spectral parameters of the EMG signal such as mean power frequency11, the ratio of low frequency to high frequency12 and the number of zero crossings13 have also been used in some studies as indices of muscle fatigue but were found to be more affected by noise than the measure of median frequency14. Though among EMG variables the slope of decline of the median frequency in sustained contractions has been considered as an index of fatigue, when it is compared against the standard of inability to hold or maintain a force the slope of MF decline does not mirror it5,6. On the other hand, the EMG amplitude increases with the decrease in force and this inverse relationship is variable. Therefore, the EMG variables though helpful indicators are far from being a gold standard measure of muscle fatigue.

Among other local factors which affect muscle fatigue is blood perfusion of the muscle and level of its oxygenation15. Until recently these measurements could not be made except invasively, hence largely ignored. With the advent of the Near-Infrared Spectroscopy such measurements can now be made noninvasively16,17. This is a noninvasive technique which depends on detecting continuous stream of reflected light from the light source of the device through muscle tissue. The light source of the device emits 700-900 nm wavelength light into the muscle. The heme and the myoglobin are the primary absorbing compounds of these frequencies, and the absorption of light by the heme group is detected as change in optical density. This again is a semi quantitative measure and expressed in percent change in optical density allowing us to infer the oxygenation/deoxygenation of the blood in the muscle and its blood volume. Using this device several authors have presented their data. These variables have been studied in the fore arm muscles18,19,20,21. De Blasi et al.17 studied oxygen consumption of the brachio-radialis muscle and its recovery time. They did not find any difference in the oxygen uptake of the muscle in isometric maximal voluntary contraction (MVC) with and without vascular occlusion. However, vascular occlusion resulted in complete desaturation of the haemoglobin and myoglobin in 15 to 20 seconds. A separate study reported that the oxygen desaturation rate occurring during incremental levels of isometric exercise without vascular occlusion was not proportional to the strength of the contraction19. It was reported that the tissue oxygenation at low levels of isometric contraction (5, 10, 15 and 50% MVC) of the extensor carpi radialis brevis muscle resulted in deoxygenation to 89%, 81%, 78% and 48% of the resting value, which was assigned 100%21. They stated that this oxygen depletion may be directly linked to the muscle fatigue. After a comparative study of submaximal isometric contractions (10% and 30% MVC) measured by NIRS and direct venous blood sampling suggested a caution in application of NIRS technology20. However, a host of other studies have reported oxygenation and blood volume in mainly quadriceps and erector spinae. Nonetheless, a direct comparison between the force fatigue and deoxygenation and blood perfusion has not been reported.

It is generally understood that there is no direct reliable quantitative measure of localized muscle fatigue. Therefore, different authors have chosen one of a variety of indicators of fatigue, such as EMG median frequency, muscle deoxygenation, oxygen uptake, heart rate, rate of perceived exertion (RPE) and visual analog scale (VAS) scores. The objective of this study was to measure EMG amplitude, median frequency, heart rate, deoxygenation, blood volume, RPE, VAS and Body Part Discomfort Rating (BPDR) in one study for one muscle and examine their relationship with the force fatigue and their inter-relationship in isometric MVC and 40% of MVC of the erectores spinae in sustained contractions. The study was then repeated for quadriceps and biceps brachii in different subjects.

MATERIALS AND METHODS

Equipments and Tools

EMG Devices

The EMG electrodes were active surface electrodes (Model DE-2.3, Delsys Inc., Wellesley, MA). They were made of 2 silver silver chloride bands (10 mm long and 1 mm wide) mounted in parallel 1 cm apart in a mounded block. The block also housed a miniature preamplifier with a gain of 10 (to amplify the signal on site) and a high pass filter at 20 Hz. These electrodes were connected to amplifiers worn around waist by means of a short cable which had multiple gain. The amplifiers had a time constant of 20 ms, a low nonlinearity, and 92 dB signal to noise ratio.

Polar Vantage XL Heart Rate Monitor

The device consisted of a transmitter incorporated in a chest band worn by subjects. The transmitter relayed the heart rate to a wristwatch receiver which could collect and hold data for up to 33 hours. This heart rate data was subsequently downloaded into a data logger.

Near Infrared Spectrascope

The model MRM-96 and the accompanying software NIRCOM from NIM, Inc., Philadelphia was used in this study. This was a noninvasive blood oxygen and blood volume trend monitor designed to measure data from the muscle bed. It was a continuous wave spectrometer that operated by transmitting light into the skin below the probe, collecting reflected light, and processing the signals by computing optical density from the measurements. The light that was not absorbed or scattered away from the detector, was collected by the photo-diode detectors in the probe and converted to digital data. The MRM-96 emitted lights of wave lengths 760 and 850 nm which were indicators of the relative quantities of oxy- and deoxy-haemoglobin. With the relative change in quantities of these compounds the light absorbed by them changed as well. The oxygenation level was indicated by the difference between two lights and the blood volume in the muscle bed was indicated by the sum of the two lights.

Load Cell and Force Monitor

A load cell (LCCB-IK) from Omega, Laval, PQ, was connected to the Force Monitor (Prototype Design, Ann Arbor, MI). The tension load cell fed to the Force Monitor which conditioned and amplified the signal and displayed the reading through a LED display. The output of the Force Monitor was fed to the Data Translation A to D card (DT2801A) of the computer for continuous sampling of the signals.

Subjective Measures

Visual Analog Scale

The subjects were provided a 10 cm long horizontal line with anchors at the two ends reading "not fatigued at all" and "worst imaginable fatigue". The subjects crossed the horizontal line according to their feeling at the time of measurement. For MVC the subjects were given this test before the start and after the end of the contraction. However, for 40% the subjects were given this test at the start and every minute thereafter till the end of the contraction.

Body Part Discomfort Rating (BPDR)

The subjects were provided with a blank line diagram of the entire body and asked to place a "x" on the part of the body where they felt discomfort due to fatigue. Subsequent to placing an "x" they were asked to rate their fatigue on a scale of 1 to 10, 1 being no fatigue and 10 being the maximal fatigue. Like the VAS scoring, this test was also given twice for MVC and one minute interval for 40% MVC.

Rate of Perceived Exertion

The rate of perceived exertion (RPE) was filled out by the subjects. The RPE was scored on a 20 point scale. Like other subjective measures, the subjects determined their RPE only twice. RPE was administered at the same times as the other subjective measures.

Common Procedures

The study was approved by the Health Research Ethics Board and all subjects provided an informed consent. The subjects were remunerated at the rate of $10.00 per hour. Normal and healthy male and female subjects with no self-reported cardiovascular, musculoskeletal, neuromuscular or psychiatric disorders were recruited from the university student population through a campus wide advertisement. After the subjects had signed the informed consent form they were familiarized with the equipment and procedures. They were also given a practice session with the experiment. They were asked to come another day, when they were first weighed and measured. On the day of the experiment, the Polar chest band was applied after slightly wetting the contact of the device. The wrist band receiver was tied around the wrist and checked to ensure that the device was working properly. Such prepared subjects were allowed to rest for a period of five minutes to obtain the resting values of heart rate, blood oxygenation, blood volume and the EMG signals. Subsequently, the subjects were required to give their isometric MVC for trunk extension without changing the postural preset angle. The subjects were instructed to build their strength to a maximum gradually within the first two seconds and maintain the maximal level of contraction for another three seconds at which time the contraction was terminated. Subsequent to this contraction the subjects were given a five-minute rest. This strength value was taken at the subjects 100% effort.

The subjects, after a five-minute rest, acquired the task position described above. In front of the subject a visual feedback mechanism was adjusted to show their 40% of isometric MVC. The subjects were instructed to build their strength to a maximum gradually within the first two seconds and maintain the maximal level of contraction for another three seconds at which time the contraction was terminated. Subsequent to this contraction the subjects were given a five-minute rest. This strength value was taken at the subjects 100% effort.

The subjects, after a five-minute rest, acquired the appropriate task position. In front of the subject a visual feedback mechanism was adjusted to show their 40% of isometric MVC. The subjects were instructed to exert in isometric mode such that their contraction indicator reached one displayed on the screen and they maintained it as long as they could without the force level dropping below 35% MVC. After this exertion the subjects were provided a rest of 30 minutes at which time they were asked to exert their MVC and hold it in maximal effort as long as they could.

Subjects

Erector Spinae

Six healthy male and six healthy female subjects volunteered with a mean (standard deviation) age, weight and height of 32.5 (4.7) years, 82.7 (9.0) kg and 170 (5.2) cm form males and 35.6 (15) years, 61.1 (8.8) kg, and 166.88 (7.4) cm for females.

Quadriceps

Ten healthy male and ten healthy female subjects with mean (standard deviation) age, weight and height of 28.5 (4.4) years, 76.3 (8.7) kg and 178.3 (5.5) cm; and 29.0 (8.7) years, 58.1 (6.8) kg, and 164 (8.0) cm for male and female samples respectively.

Biceps Brachii

Nine healthy male subjects with a mean (standard deviation) age, weight and height of the experimental sample was 25.7 (2.1) years, 78.9 (9.5) kg and 180.1 (4.3) cm respectively.

Task

Trunk Extension

The subjects stood in front of an iron chain anchored to the floor with an intervening load cell at one end and an industrial size handle at the other. The subjects flexed their trunks by 45º in stooping posture. The level of the handle was adjusted individually to the height of the subject's hands. In this position, the subjects provided their erector spinae contractions according to the protocol described above.

Knee extension

The subjects were required to give their isometric contractions of knee extension without changing the postural preset angle (knee and hip angles 90º) while seated on a Quadriceps Strengthening Table.

Elbow Flexion

The subjects stood upright in front of an iron chain anchored to the floor with an intervening load cell and a round handle at the upper end. The subjects flexed their right (dominant) arms by 90º at the elbow while the upper arms hung vertically down from the shoulders. The level of the handle was adjusted individually to the height of the subject's hand. In this position, the subjects were required to give their isometric contractions of elbow flexion without changing the preset angle at the wrist, elbow or shoulder according to the protocol described above.

Specific Procedures: Trunk extension

Their erector spinae were palpated and the pre-calibrated NIRS probe was applied on the right erector spinae muscle at L3 level. Adjacent to the NIRS probe, bipolar surface electrodes were applied to skin over the muscle after abrading it with alcohol-acetone soaked paper towel at T10 and L1 levels on the right side and T10 and L3 levels on left erector spinae. After application of the probe and the electrodes, the subjects were grounded and it was ensured that the two pre-calibrated measuring devices were working as desired.

Specific Procedure: Knee extension

Subjects' vastus lateralis and vastus medialis were palpated and the pre-calibrated NIRS probe was applied on the right vastus lateralis. Adjacent to the NIRS probe, bipolar surface electrodes were applied to the skin over the vastus lateralis and vastus medialis 2 cm and 4 cm proximal to the myotendinous junction after abrading it with alcohol-acetone soaked paper towel. After application of the probe and the electrodes, the subjects were grounded and it was ensured that the two pre-calibrated measuring devices were working as desired.

Specific Procedures: Elbow Flexion

The subject's biceps were palpated and the pre-calibrated NIRS probe was applied on the muscle. Adjacent to the NIRS probe, a single bipolar surface electrode was applied to skin over bicep brachii after abrading it with alcohol-acetone soaked paper towel. After application of the probe and the electrode, the subjects were grounded and it was ensured that the two pre-calibrated measuring devices were working as desired.

Data Acquisition

The suitably conditioned and amplified data from the load cell, NIR Spectroscope and EMG amplifier were sampled at 1 kHz for the entire duration of isometric MVC, 40% MVC fatiguing contraction and maximal fatiguing contraction continuously. These data were fed to Data Translation (DT 2801A) A to D board for conversion into digital values. These were then stored in the computer memory. A Pentium computer was used as the controller and storage device. The data acquisition was carried out using a specially written software for data collection and controlling the experiment.

Data Analysis

The data of the three experiments were analyzed separately. The force trace was smoothed using 7-point smoothing routine repeated once. From this trace the peak value was read and the average value calculated. Task duration for each individual was divided into 10 equal parts and values corresponding to each decile of the task durations were extracted. The decile values of all subjects were pooled within each experiment separately and descriptive statistics calculated for further statistical analysis. A similar processing was done for heart rate, muscle blood oxygenation, muscle-bed blood volume, and EMG amplitude. The EMG signals were subjected to Fast Fourier Transform analysis to obtain the median frequency according to methods described in Kumar and Narayan5 and Kumar et al.6. These quantitative values were used to develop magnitude of the signal and the task decile plot.

The statistical analysis consists of four sub analysis: Descriptive statistics of all characteristics (ii) Analysis based on linear mixed effects to examine the predictability of force through other characteristics such as blood volume, oxygen intake, RPE, VAS and EMG measurements; (iii) Trend analysis to examine progressive change with increasing task duration, and (iv) Between subject and within subject correlation analyses to study interrelationship among measurements.

Linear Mixed Effects Model

A linear mixed effects model with subjects as a random factor and task cycle as the repeated factor were fitted to predict Force under both MVC and 40% MVC contractions. In the model `subjects' was used as a random component to incorporate repeated measure nature of the experiment in the analysis. Further, it should be noted that all measured characteristics, except gender, are not controlled by the design. Hence, to study force through the remaining characteristics, like blood volume, oxygen intake, RPE, VAS, a conditional linear mixed model was adopted by considering force as the dependent variable. Pearson Product Moment Correlations among all variables based on both within-subjects covariance and between-subjects matrices were calculated between the magnitude of force and the magnitude of each of the measured variables to determine the marginal strength of correlation of each independent variable with force. A matrix of such correlations was developed for MVC and 40% MVC variables to glean the interrelationship between all independent variables. After eliminating non-significant predictors in the analysis the final model for predicting force was given for both MVC and 40% MVC contractions.

RESULTS

Force and Time

Trunk Extension

The mean maximal voluntary contraction forces were 899 N (238) N and 431 N (135) N for male and female samples respectively. The mean durations for which the maximal contraction effort could be sustained was 68.1 (39.9) s and 72.3 (37.0) s for males and females respectively though the force kept declining through the hold. Similarly the mean durations for 40% MVC were 150.6 N (85.7) s and 139.0 (104) s respectively for male and female samples.

Knee Extension

The mean maximal voluntary contraction forces (standard deviations) for the experimental sample of male and female experimental sample of subjects were 345.7 (125) N and 220.3 (47.4) N respectively. The maximal voluntary isometric contraction of the quadriceps was held for 85.0 (25.1) s and 87.0 (21.5) s by male and female samples respectively. The holding time for 40% MVC contraction for male and female samples were 66.4 (23.9) s and 56.7 (29.0) s, respectively.

Elbow Flexion

The mean maximal voluntary contraction force of the experimental sample for elbow flexion was 197.6 N (S.D. 25.9 N). The mean duration for which the maximal contraction effort could be sustained was 58.1 s (S.D. 17.6 s), though the force exerted kept on declining through the entire duration. Similarly the mean 40% force recorded was 79.0 N (S.D. 10.4 N) and the mean duration for sustaining this load was 275 s (S.D. 35.8 s).

Objective Variables at Maximal Voluntary Fatiguing Contraction

Trunk Extension

At the maximal voluntary contraction the continuous monitoring at 1 kHz of the force, EMG, blood oxygenation and blood volume provided continuous data of the lumbar and thoracic erector spinae are presented for males and females in Figures 1 and 2. The means and standard deviations were presented at every 10% task intervals. A spectral plot of the male lumbar and thoracic erector spinae in MVC fatiguing contraction is shown in Figure 3.




During the task, the median frequencies declined to 96%, 92%, 82% and 91% respectively. The blood oxygenation and blood volumes declined by 205% and 257%. The EMG amplitude for left lumbar, left thoraic, right lumbar and right thoracic among females declined to 75%, 81%, 76%, and 77% respectively. Their median frequencies declined to 87%, 91% and 98% respectively. Interestingly, the blood oxygenation declined only by 89% and the blood volume increased to 240%.

Knee Extension

The continuous data of the force, EMG amplitude, EMG median frequency, blood oxygenation and blood volume sampled at 1 kHZ are presented in Figures 4 and 5. The means and standard deviations are presented at intervals corresponding to 10% of each task. A steady decline in force was mirrored most closely by the EMG amplitude and less closely by the median frequency. Spectral plots of the vastus lateralis and vastus medialis muscle in MVC fatiguing contraction of males are presented in Figure 6. The spectral plots show a narrowing of the frequency band and decrease in amplitude of the signals towards the end of the task. By the end of the contraction effort the force dropped to 40% in males and 44% in females. The EMG amplitude for VL2, VL4, VM2 and VM4, among men dropped to 50%, 51%, 44% and 43%, respectively. However, the median frequencies of these muscles in men were 100%, 87%, 93% and 88%, respectively, in the same order. In females the EMG amplitude dropped to 41%, 44%, 37% and 45.5% for VL2, VL4, VM2, and VM4, respectively. In the same order the drop in the median frequency was to 81%, 84%, 79% and 84.9%.




Elbow Flexion

At maximal voluntary contraction the continuous monitoring at 1 kHz of the force, EMG, blood oxygenation and blood volume provided continuous data presented in Figure 7. The means and standard deviations are presented at every 10% task intervals. A steady decline in force was mirrored most closely by the median frequency of the recorded EMG. The EMG amplitude also declined steadily and progressively for up to 80% of the task cycle beyond which it dropped more rapidly.


Objective Variables at 40% MVC Fatiguing Contraction

Trunk Extension

In this contraction the patterns in variation of measures are presented in Figures 8 and 9. With a progressive and gradual decline in force there was a gradual and progressive decline in the MF of the EMG and its amplitude (Figures 8 and 9). The spectral analysis of the EMG of the erector spinae in this contraction also demonstrated the same progressive shift of MF as in MVC contractions. The optical density of the blood oxygen and the blood volume continued to increase indicating progressive increase in blood volume (116%) as well as blood oxygen levels (145%) (Figures 8 and 9). The EMG amplitude for the left and right lumbar and thoracic regions were 35%, 45%, 40% and 45% declining from 55%, 53%, 70% and 52% respectively (order left lumbar, left thoracic, right lumbar and right thoracic). Among females the EMG amplitudes of the left lumbar and thoracic and right lumbar and thoracic erector spinae decreased from 70%, 68%, 61% and 64% to 66%, 57%, 56% and 60% respectively. Their median frequencies either remained the same or marginally declined.



Knee Extension

The variable of force, EMG amplitude, median frequency, blood oxygenation, blood volume and heart rate recorded are presented in Figures 10 and 11. Also the subjective variables of visual analog score and the rate of perceived exertion measured at discrete intervals and interpolated in between are plotted in Figures 10 and 11 along with contraction period the force value declined to 23% in males and 24% in females. The EMG score of VL2, VL4, VM2, and VM4, in males dropped to 38%, 31%, 29.4% and 28% respectively. The corresponding median frequency values were 100%, 100%, 94.8% and 99%. In females, the EMG amplitude of VL2, VL4, VM2, and VM4 declined to 49%, 50%, 43.4% and 48%, while the corresponding median frequencies declined to 82%, 88%, 90.7% and 95%. The spectral plots of the vastus lateralis muscle did not show a clear and decisive drop in median frequency in both gender (Figure 12). The blood oxygenation initially dropped rapidly but remaining stable between 20% - 80% of the task cycles and subsequently demonstrated a small rise. The muscle bed blood volume, however, after an initial drop kept on increasing. The heart rate, VAS score and RPE score, after an initial stable value, kept on rising through the entire duration of the contraction (Figures 10 and 11).




Elbow Flexion

The oxygen uptake, ventilation volume, heart rate, visual analog scale score and the RPE score were obtained at one-minute intervals. Between the intervals the data were interpolated and the values corresponding to appropriate task percentile value extracted from the interpolation. The pattern in variation of measures is presented in Figure 13. With a progressive and gradual decline in force there was a gradual and progressive decline in the MF of the EMG but its amplitude remained relatively stable (Figure 13). The spectral plot of the EMG of the biceps brachii in this contraction did not demonstrate the same progressive shift of MF as in MVC contractions. The optical density of the blood oxygen and the blood volume continued to increase indicating progressive increase in blood volume as well as blood oxygen levels (Figure 13). The oxygen uptake, ventilation volume, heart rate, VAS score and RPE score all progressively increased with a progressive decrease in force (Figure 13).


Subjective Variables

The scores of visual analog scale and rate of perceived exertion is presented in Table 1. In both genders the scores for both visual analog scale and rate of perceived exertion were higher in 40% maximal voluntary contraction. The body part discomfort rating showed that the maximum discomfort was felt in low back with scores between 6.75 to 7.83 on a 10 point scale with the exception of females in MVC fatiguing contraction for females where the score was a mere 3.5. The behaviour of subjective variables for knee extension and elbow flexion is similar to those of the trunk extension.

Statistical Analyses

Trunk Extension

The summary tables of analyses of variance with repeated measures for the MVC fatiguing and 40% fatiguing contraction for all independent and the dependent variables are presented in Tables 2 and 3. The dependent variable of force and all independent variables (blood oxygenation, blood volume, EMG MF and EMG amplitude) were significant for gender and percentile levels between subjects (p<0.001) in the MVC trial. The latter observation indicates though the two genders respond differently but there was a significant and progressive change with increasing task duration in both genders despite the effort of the subjects to maintain at a constant level. However, in 40% MVC the gender did not make a significant difference for the median frequency, but it did so for all other variables (p<0.01). The task percentile level did not make a significant difference in blood volume and oxygenation but affected all other variables significantly (p<0.02).

For MVC contractions, there was a significant interaction between EMG amplitudes and gender. Hence separate models were fitted for males and females. For males the significant predictors are (in the order of significance) EMG LL3, interaction between MFRL1 and MFRT10, BV and EMGRL1, while for females similar predictors are BV, EMG LL3, EMG RL1 and the interaction between EMG RL1 and EMG RT10.

For the fitted models the readers are directed to Kumar et al.22 which explain 98% and 97% of variance among males and females respectively for MVC. The regression models for 40% MVC trunk extension explain 96% and 97% of variance for males and females respectively.

The summary tables of analysis of variance with repeated measures for the MVC fatiguing and 40% fatiguing contraction for all independent and dependent variables are presented in Tables 4 and 5. The dependent variable of force and all independent variables (blood oxygenation, blood volume, EMG MF and EMG amplitude) were significantly different at various task percentile levels within the subject (p<0.001) and between subjects (p<0.001) in the MVC trial. The latter observation indicates significant and progressive change with increasing task duration despite the effort of the subjects to maintain at a constant level. Identical results were obtained in 40% MVC fatiguing trials where in addition to the dependent variable of force the independent variables blood oxygenation, blood volume, EMG amplitude, MF, heart rate, RPE score and VAS score showed significantly different magnitude of these variables at different task cycles within the subject (p<0.001) and between the subjects (p<0.001).Thus clearly in both contractions as the time progressed the fatigue progressed.

The set of independent variable for this case consists of blood volume, blood oxygenation, heart rate, EMG amplitude, EMG median frequency, visual analog scale, rate of perceived exertion and body part discomfort rating. The final frequency model is given below.

Force = 140.92 + 53.17 EMG amplitude - 41.9 blood volume + 0.045 blood oxygenation - 21.15 VO2 - 0.64 heart rate + 0.68 rate of perceived exertion + 1.39 discomfort rating of the upper arm.

The order of importance of significant predictors was determined based on absolute values of t-statistics. The goodness-of-fit of the final model was evaluated using reduction in mean squared error. An 80% reduction in mean squared error with significant predictors was observed compared to the model without any significant predictors.

Correlation Analysis

Trunk Extension

The within subject correlation coefficients between force and other independent variables for maximal voluntary contraction, and 40% maximal voluntary contractions for trunk extension were similar to those of knee extension and elbow flexion.

Knee Extension

The correlation coefficients (based on between - subject covariance matrix) between the force and other measured variables at MVC and 40% MVC fatiguing contractions in knee extension are presented in Tables 6 and 7. In the MVC fatiguing contraction there was a significant negative correlation between force and muscle bed blood volume (r = -0.833; p<0.01) and muscle bed oxygenation (r =-0.772; p<0.01). The correlation coefficient between the force and EMG amplitudes of vastus lateralis and vastus medialis recorded at two different sites ranged between r = 0.583 to 0.892 (p<0.01); this correlation between the force and median frequencies (MF) measured at the same sites ranged between r = 0.035 to 0.423. This clearly demonstrates that the force is more strongly correlated with EMG amplitude than the MF, which traditionally has been considered a measure of fatigue. It is also evident that most of the independent variables are generally significantly intercorrelated.; in particular, muscle bed oxygenation and muscle bed blood volume (r=0.775;p<0.01), and mutual correlations among EMG amplitude measured at four sites ranged from 0.475 to 0.793,p<0.01).

The correlation matrix for the 40% MVC fatiguing contraction presents a similar picture with significant negative correlation between force and blood volume (r = -0.380; p<0.05) and blood oxygenation level (r = -0.724; p<0.01). However, a slightly stronger correlation was observed with the EMG amplitude measured at four sites varying from r = 0.703 to 0.915; p<0.01). These were stronger values compared to those obtained for the MF (r = 0.238 to 0.506). The variables of heart rate, VAS, RPE, and thigh discomfort correlated negatively with force but none of them are significant (HR r = -0.242 ; VAS r = -0.119, RPE = -0.205, thigh discomfort r = -0.255).(Tables 6 and 7).

Elbow Flexion

The correlation coefficient between the force and other measured variables for MVC and 40% MVC fatiguing trials are presented in Tables 8 and 9. In the MVC fatiguing contraction the MF of EMG was strongly correlated with the force (r = .91; p<0.001). Blood oxygenation and blood volume also were correlated with the force, albeit moderately (Table 8). Intercorrelation coefficients between the independent variables largely remained between low to moderate levels. Only the blood volume optical density and EMG amplitude reached a moderate correlation coefficient value (r = .61; p<0.001). Most correlation coefficient values were positive except the correlation between blood oxygenation level and blood volume and EMG amplitude.

The correlation matrix for the 40% MVC fatiguing contraction presented a different picture (Table 9). With progressively decreasing force during this contraction only EMG MF and amplitude were positively correlated (r = .34 and .11 respectively; p<0.001). All other variables were negatively and significantly correlated with the force (Table 9). On average VAS and RPE scores showed modest correlation with force (r = -.67 and -.54 respectively; p<0.001) (Table 9). They also consistently demonstrated good correlation with all other independent variables as well except blood oxygen optical density and EMG amplitude. The only variable that had better correlation with force was blood volume optical density (r = -.78; p<0.001). The blood oxygenation optical density and MF of the EMG showed only a modest correlation with force (r = -.39 and .39 respectively; p<0.001).

DISCUSSION

Localized muscle fatigue has been considered to be of considerable significance in possible injury mechanisms23. Strenuous exercise, which includes fatiguing contractions causes disturbance of muscle homeostasis. Structural abnormalities in skeletal muscles of humans following stressful exertions have been reported24,25,26,27. Progressive deterioration of muscle performance occurs with fatigue. Fatigue may be modulated through many different mechanisms and at many different sites. Possible sites and mechanisms include neurons, axon, terminal bouton, depletion of neurotransmitter, refractory response of the muscle cell membrane, depletion of ca++ from the sarcoplasmic reticulum, depletion of ATP and its supply to the muscle cells.

With the onset and progression of fatigue, as indexed by the force magnitude and muscle discomfort, there is an initial reduction in EMG amplitude followed by an increment and eventual dissipation associated with cessation of activity. This suggests that the electrophysiological mechanism of muscle contraction remains intact till the end. It is due to a significant decline in force output that the synchronization of motor unit occurs12,28 to maximize the electrical impact on the contractile phenomenon. Univariate ANOVA for all objective variables revealed that the gender was a strong determinant. Thus females generated significantly less force on muscle contraction. Also, the EMG amplitude, MF, blood volume and blood oxygenation were significantly different between males and females (p<0.001), for both MVC and 40% MVC contractions. In 40% MVC, men and women had significant differences in the heart rate as well. Clearly, men are heavier than women with significantly greater body mass. Force generation is dependent on the cross sectional area of the muscles which is greater in men, explaining this difference. Similarly, the larger cross sectional area of the muscle fibres will increase the conduction velocity of the action potential affecting the MF. Larger muscle mass will likely also, require larger amount of blood circulation and ATP for contraction. Where these are proportional to the cross sectional area is not clear, but it appears to be a likely cause of these differences. Interestingly, the subjective measures are not significantly different between genders. Thus information obtained through VAS, RPE, or BPDR do not discriminate between genders making them more universal tools for the assessment of fatigue.

In maximum voluntary contractions the EMG amplitudes at different sites within the experiment demonstrated the highest correlation coefficients with force. Though these were all significant but explained the variances in males only ranging from 20.4% to 62.4%. The variances explained in females ranged from 24% to 47.1%. The positive correlations clearly establish the relationship that, as the force is declining with progressive fatigue so is EMG amplitude, a finding also supported by the works of Crone et al.29, DiLazzaro et al.30 and Kumar et al.31. Similarly, even in 40% MVC contractions, the EMG amplitudes demonstrate the highest correlation of all variables explaining from 26.1% to 43.0% variance in males and 16.8% to 32.4% variance in female sample. Surprisingly, the MF decline in maximal voluntary contraction and 40% maximal voluntary contraction was poorly correlated with force and explained variances between 2.4% to 19.8% and 5.5% to 10.8% in males and 1.7% to 16% and 1% to 16.4% in females. While correlations and variances explained were significant (p<0.01), the weakness of association is less convincing than what is reported in the literature.

Muscle contraction is a resultant expression of nervous, metabolic, electrophysiological, mechanical and subjective factors. The primary energy source for muscle contraction is ATP. Since there is only a small amount of ATP present in skeletal muscles, it gets depleted quickly and needs to be replenished for sustained contraction through new blood supply. This physiological rationale suggests that the muscle blood volume and level of it oxygenation should faithfully mirror the degree of fatigue and decline in force. These variables, however, have shown only a modest negative correlation in MVC in males and females in quadriceps contraction, for example (blood oxygenation r = -.159 to -.221; p<0.01; blood volume r = .477 to -.637; p<0.01). The blood oxygen level during a MVC explained only 2.5% to 4.8% of variance, where as the blood volume explained 22.7% to 40.5% of variance. In 40% MVC fatiguing contraction the blood oxygenation in males and females explained variances of 3.5% and 26.2%; whereas the blood volume explained 21.4% and 8.5% in males and females, respectively. Despite the assertions of McCully17 and Hamaoka, Murthy et al.21 and others that NIR spectroscopy provides valid data of muscle oxygenation and muscle blood volume, a low to moderate correlation coefficient and only low to modest variances explained in the current experiments, remain enigmatic. However, it is also fair to point out that MacDonald et al31, reported unreliable results from NIRS of femoral blood gases with exercise. Extreme care taken in the experiments make it less likely that experimental error may have played a role.

The subjective variables of visual analog score, rate of perceived exertion and body part discomfort ratings, measured in 40% MVC fatiguing contractions, had a modest correlation with force among males (r = -0.413 to -0.493; p<0.001) explaining 17% to 24.2% of variance. Among females, these values were further reduced (r = -0.338 to -.0418; p<0.01) explaining variances between 11.4% to 17.4%.

The results obtained in these studies do not show any of the variables to be strongly correlated with force and reflecting it faithfully, though EMG amplitude was found to be the best among all variables, quantitatively. Whether these factors do not proportionally respond to fatigue quantitatively or their response follows a pattern of small changes, is hard to say. It is possible that if the total response were to be assigned a value of 100%, even the smaller chances will then represent a proportionally higher percentage of force fatigue. In any case, it is also quite likely that none of the variables selected demonstrate total dependence on fatigue. When these variables are considered in batch, they together explain a variance of 64.4% and 60.2% in maximal voluntary contraction in males and females, respectively in the quadriceps experiment. Similarly, at 40% MVC contraction the variances of 71.9% and 68.6% were explained. The experiments with erector spinae and biceps brachii show very similar results in all aspects. From the results obtained, therefore, it is concluded that it will be desirable for us not to predict or measure fatigue based on any one variable. We rather need to consider a combination of variables for reliable information, regarding a given muscle with respect to fatigue.

In summary, with the series of experiments carried out it would appear that for high grade contractions the EMG amplitude and the median frequency follow the fatigue more closely explaining most variance out of all variables. In lower grade contractions however, the visual analog score is the better variable. However, neither of these variable account for most of the variance. Thus, a single variable indexing of localized muscle fatigue leaves a lot to be desired for.

Received: 16/11/2005 — Accepted: 23/01/2006

  • 1. Borg G. Physiological bases of perceived exertion. Medicine and Science in Sports and Exercise 1982; 14: 377-81.
  • 2. Rohmert W. Ermittlung von Erholungspausen fur Statistiche Arbeit des Menschen. Int. Z. Angew. Physiol 1960; 18: 123-124.
  • 3. Chaffin D. Localized muscle fatigue definition and measurement. Journal of Occupational Medicine 1973; 15: 346-54.
  • 4. De Luca C. Myoelectric manifestations of localized muscle fatigue in humans. CRC Critical Reviews in Biomedical Engineering 1985; 11: 251-79.
  • 5. Kumar S, Narayan Y. Spectral parameters of trunk muscles during fatiguing isometric axial rotation in neutral posture. Journal of Electromyography & Kinesiology 1998; 8: 257-67
  • 6. Kumar S, Narayan Y, Stein RB, Snyders C. Muscle fatigue in axial rotation of the trunk. International Journal of Industrial Ergonomics 2001; 28: 113-25.
  • 7. Mannion AF, Dolan P. Electromyographic median frequency changes during isometric contraction of the back extension to fatigue. Spine 1994; 19: 1223-29.
  • 8. Roy S, DeLuca C. Surface electromyographic assessment of low back pain. In Kumar S, editor. Electromyoprophy in Ergonomics. London: Taylor & Francis; p. 259-95.
  • 9. Van Dieen JH, Toussaint HM, Thissen C, Van de Ven A. Spectral analysis of the erector spinae EMG during intermittent isometric fatiguing exercise. Ergonomics 1993; 36: 407-14.
  • 10. Van Dieen J, Boke B, Oosterhuis W, Toussaint, HM. The influence of torque and velocity on erector spinae muscle fatigue and its relationship to changes of electromyogram spectrum density. Eur J Appl Physiol Occup Physiol 1996; 72: 310-15.
  • 11. Kwanty E, Thomas DH, Kwanty HG. An application of signal processing techniques to the study of myoelectric signals. IEEE Transactions of Biomedical Engineering 1970; 17: 303 - 12.
  • 12. Bigland-Ritchie B, Donovan EF, Roussos CS. Conduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts. Journal of Applied Physiology 1981; 51: 1300-1305.
  • 13. Hagg G. Electromyographic fatigue analysis based on the number of zero crossings. Pflingers Arch 1981; 391: 78-80.
  • 14. Stulen FB, DeLuca CJ. Frequency parameters of the myoelectric signal as a measure of muscle conduction velocity. IEEE Transactions of Biomedical Engineering 1981; 28: 515-23.
  • 15. Grandjean E. Fitting the task to man. London: Taylor & Francis; 1988.
  • 16. Hamaoka T, Iwane H, Shimomitsu T, Katsumura T, Murase N, Nishio S et al. Noninvasive measures of oxidative metabolism on working human muscles by near infrared spectroscopy. Journal of Applied Physiology 1996; 81: 1410-17.
  • 17. McCully KK, Hamaoka T. Near Infrared Spectroscopy: What can it tell us about oxygen saturation in skeletal muscle? Exercise Sports Science Review 2000; 28: 123-27.
  • 18. De Blasi RA, Cope M, Elwell C, Safoue F, Ferrasi, M. Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy. European Journal of Applied Physiology 1993; 67: 20-25.
  • 19. De Blasi RA, Sfareni R, Pietranico B, Mega AM, Ferrari M. Noninvasive measurement of brachioradial muscle VO2 - blood flow relationship during graded isometric exercise. Advances in Experimental Medical Biology 1996; 388: 293-98.
  • 20. Hicks A, McGill S, Hughson RL. Tissue oxygenation by near infrared spectroscopy and muscle blood flow during isometric contractions of the forearm. Canadian Journal Applied of Physiology 1999; 24: 216-30.
  • 21. Murthy G, Kahan NJ, Hargens AR, Rempel D. Forearm muscle oxygenation decreases with low levels of voluntary contraction. Journal of Orthopaedic Research 1997; 15: 507-11
  • 22. Kumar S, Fagarasanu M, NarayanY, Prasad N. Measures of localized spinal muscle fatigue. Ergonomics 2006 (in press).
  • 23. Kumar S. Theories of musculoskeletal injury causation. Ergonomics 2001; 44: 17-47.
  • 24. Friden J. Changes in human skeletal muscle induced by long term eccentric exercise. Cell Tissue Research 1984; 236: 365-72.
  • 25. Friden J, Sieger J, Ekblem B. Sublethal muscle fibre injuries after high-tension anaerobic exercise. European Journal of Applied Physiology 1988; 57: 360-8.
  • 26. Newman DJ, McPhail G, Mills KR, Edwards RHT. Ultrastructural changes offer concentric and eccentric contractions of human muscle. Journal of Neurological Science 1983; 61: 109-22.
  • 27. Friden J, Lieber R. Structural and mechanical basis of exercise induced muscle injury. Medicine and Science in Sports and Exercise 1992; 24: 521-30.
  • 28. Lippold OCJ, Redfearn JWT.  (1960). The electromyography of fatigue. Ergonomics 1960; 3: 121-31.
  • 29. Crone C, Johnsen LL, Hultborn H, Orsmes GB. Amplitude of the maximum motor response (Mmax) in human muscles typically decreases during the course of an experiment. Experimental Brain Research 1999; 124: 265-70.
  • 30. Di Lazzaro V, Oliviero A, Tonali PA, Mazzone P, Insola A, Pilato F, Saturno E, Dileone M, Rothwell JC. Direct demonstration of reduction of output of the human motor cortex induced by a fatiguing muscle contraction. Experimental Brain Research 2003; 149: 535-38.
  • 31. Kumar S, Amell T, NarayanY, Prasad N. Measurement of localized muscle fatigue in biceps brachii using objective and subjective measures. In Kumar S, editor. Muscle Strength. Boca Raton, FL: S Publisher CRC Press; 2004. p. 105-21.
  • 32. MacDonald MJ, Tarnpolsy MA, Green HJ, Hughson RL. Comparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans. Journal of Applied Physiology 1999; 86:687-693.
  • Corresponding author:
    Shrawan Kumar, Ergonomics Research Laboratory, Department of Physical Therapy, University of Alberta
    Edmonton, Canada T6G 2G4
    e-mail:
  • Publication Dates

    • Publication in this collection
      21 Aug 2006
    • Date of issue
      2006

    History

    • Accepted
      23 Jan 2006
    • Received
      16 Nov 2005
    Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia Rod. Washington Luís, Km 235, Caixa Postal 676, CEP 13565-905 - São Carlos, SP - Brasil, Tel./Fax: 55 16 3351 8755 - São Carlos - SP - Brazil
    E-mail: contato@rbf-bjpt.org.br