Eustachian valvula: real-time three-dimensional transthoracic echocardiographic imaging

IMAGE

Eustachian valvula: real-time three-dimensional transthoracic echocardiographic imaging

Marcelo Luiz Campos Vieira; Antônio José Sproesser

Hospital Israelita Albert Einstein - São Paulo, SP - Brazil

Mailing address Mailing address: Marcelo Luiz Campos Vieira Rua Cardoso de Melo, 463/21 04548-002 São Paulo, SP - Brazil E-mail: mluiz766@terra.com.br

Key words: Echocardiography; heart valves, Eustachian valvula, anatomy.

The use of three-dimensional echocardiography for the analysis of cardiac structures allows the viewing of planes that make the anatomic identification more realistic1-3. We present the case of a 41-year-old male patient, a high-performance athlete (marathoner) in whom an Eustachian valvula was identified. In the two-dimensional echocardiographic study (Figure 1), an elongated, filiform structure is observed. Three-dimensional echocardiography shows an elongated, but not filiform valvula which appears as a structure with a wide base, as identified in the short-axis view, which enables anatomic observation from a depth or elevation plane (Figure 2).



Potential Conflict of Interest

No potential conflict of interest relevant to this article was reported.

Sources of Funding

There were no external funding sources for this study.

Study Association

This study is not associated with any graduation program.

References

1. Li J, Sanders SP. Three-dimensional echocardiography in congenital heart disease. Curr Opin Cardiol. 1999; 14: 53-9.

2. Kisslo J, Firek B, Takahiro O, Kang DH, Fleishman CE, Stetten G, et al. Real-time volumetric echocardiography: the technology and the possibilities. Echocardiography. 2000; 17: 773-9.

3. Ahmad M. Real-time three-dimensional echocardiography in assessment of heart disease. Echocardiography. 2001;18 (1): 73-7.

Manuscript received January 09, 2007; revised manuscript received January 01, 2007; accepted March 13, 2007.

  • Mailing address:
    Marcelo Luiz Campos Vieira
    Rua Cardoso de Melo, 463/21
    04548-002
    São Paulo, SP - Brazil
    E-mail:
  • Publication Dates

    • Publication in this collection
      25 Sept 2007
    • Date of issue
      Sept 2007
    Sociedade Brasileira de Cardiologia - SBC Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil, Fax: +55 21 3478-2770 - São Paulo - SP - Brazil
    E-mail: revista@cardiol.br