Acessibilidade / Reportar erro

Determination of the HMX and RDX content in synthesized energetic material by HPLC, FT-MIR, and FT-NIR spectroscopies

Abstract

A new method has been developed for determining the content of mixtures of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), the HMX/RDX ratio, in explosive compositions by Fourier transform infrared spectroscopy (FT-IR), in the regions MIR (mid infrared) and NIR (near infrared) with reference values obtained by chromatographic analysis (HPLC). Plots of relative MIR (A917 / A783) or NIR absorbance values (A4412 / A4317) versus HMX/RDX ratio determined by HPLC analysis revealed good linear relationships.

energetic material; FT-MIR-NIR; HPLC


ARTIGO

Determination of the HMX and RDX content in synthesized energetic material by HPLC, FT-MIR, and FT-NIR spectroscopies

Elizabeth C. MattosI, * * e-mail: mattos@directnet.com.br ; Enézio D. MoreiraI; Rita C. L. DutraII; Milton F. DinizII; Ana Paula RibeiroII; Koshun IhaIII

IDivisão de Sistemas Bélicos, Instituto de Aeronáutica e Espaço e Instituto Tecnológico da Aeronáutica, Centro Técnico Aeroespacial, Praça Marechal do Ar Eduardo Gomes, 50, 12228-904 São José dos Campos - SP

IIDivisão de Química, Instituto de Aeronáutica e Espaço, Centro Técnico Aeroespacial

IIIInstituto Tecnológico da Aeronáutica, Centro Técnico Aeroespacial

ABSTRACT

A new method has been developed for determining the content of mixtures of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), the HMX/RDX ratio, in explosive compositions by Fourier transform infrared spectroscopy (FT-IR), in the regions MIR (mid infrared) and NIR (near infrared) with reference values obtained by chromatographic analysis (HPLC). Plots of relative MIR (A917 / A783) or NIR absorbance values (A4412 / A4317) versus HMX/RDX ratio determined by HPLC analysis revealed good linear relationships.

Keywords: energetic material; FT-MIR-NIR; HPLC.

INTRODUCTION

Energetic compounds, such as HMX and RDX, have been employed in several applications, propellants compositions, energetic binder explosive, etc1. The synthesis of HMX and RDX is performed by nitration of hexamine2,3. The formation of a by-product BMX (a mixture of RDX and HMX) 4 occurs in the process.

The synthesis of these high energetic solids is an important research developed in the CTA (Aerospace Technical Center) 3 and rapid methods for the quality control of laboratory synthesized products are necessary because these products, in suitable ratios, will be used in plastic bonded explosive (PBX) researches. Therefore, it is important to know the HMX and RDX contents in energetic compositions.

In a previous publication5, materials obtained during the synthesis of HMX were characterized by FT-IR transmission spectroscopy and/or Fourier transform infrared photoacoustic spectroscopy (FT-IR/PAS). The characterized species during the synthesis of HMX were a-HMX, b-HMX, and HMX/RDX mixtures.

Different methods employing several techniques have been developed for determination of the HMX and RDX contents6. Some previous investigations of MIR methods have used Nujol mulls but this technique is susceptible to errors due to variations in mulling. The solution IR methods are not recommended when a great amount of HMX or RDX is used in energetic compositions due to the very low solubility of the explosive, at room temperature, in solvents suitable for IR analysis.

High performance liquid chromatography (HPLC) is used for the investigation of explosives in large extent7. Acetonitrile solvent is often employed to determine the HMX and RDX contents in energetic composition8. Although the HPLC method gives good results, there are several time consuming steps related to the sample preparation or measurements. An HPLC analysis takes three hours.

Considering that the acetonitrile is not suitable for IR solution analysis, an alternative method for determining HMX and RDX is proposed using another IR transmission technique (potassium bromide pellet).

In addition, NIR-spectroscopy has grown to become one of the most important tools for on-line analysis in process technology and quality control. It is sensitive like the MIR-spectroscopy and it is better applied to industrial environments9. Fast measurements of energetic materials showed that NIR-spectroscopy could also be used during the manufacture control of propellants and explosives10.

In the MIR/NIR method the solid samples are prepared for spectrometric analysis such as received, as KBr pellet. Several steps are eliminated and although the data of MIR and NIR methods represent the median of five analysis, the time spent in the analysis is smaller than that involved in the HPLC method.

Then, this paper presents a new quantitative method for determination of the HMX/RDX ratio based on HPLC data (reference values) and NIR and MIR spectroscopy (KBr technique). BMX samples, with its HPLC reference values, were used to develop the MIR/NIR methodology. The advantages of the methods here presented are that they involve few steps, and do not require complex sample preparation.

EXPERIMENTAL PART

The nitration of hexamine to yield crude HMX is conducted in a stirred jacketed reactor. The reactor is served by three head tanks, which are used to control the quantity and the addition rate of the three reactants, (a) acetic anhydride, (b) hexamine/acetic acid solution, and (c) nitric acid/ ammonium nitrate solution2-4.

The reactants are added into the reactor at carefully controlled rates in accordance with a programmed sequence. The temperature is maintained controlled during the process. At the end of the reaction period a volume of water is added and the mixture is simmered for a period to precipitate the HMX. An increase in the temperature causes the majority of unwanted by-products to be destroyed. The solid HMX is filtered hot and washed with water. The filtrate contains the by-product BMX that is later precipitated. It is necessary to control the content of BMX samples, because during the nitration of hexamine part is converted in RDX, and this has influence in the yield of reaction.

Chromatographic analyses were carried out in a model 481 HPLC Waters system, which was equipped with a 6000 A pump and a Lambda - Max 481, LC Spectrophotometer UV detector at 230 nm. A µ Bondapak C18 125Å column, 10 µm, 3.9 x 300 mm was used; methanol/water mixture 40/60 at a flow rate of 1.2 mL/min was used as mobile phase.

The total injection volume was 10 µmL (injector: U6 K universal of Waters). Acetonitrile was used as solvent for the explosives samples. The concentration of the substances in the sample solutions used was 10 mg/L. The internal standard used was o-nitroaniline (ONA). The evaluation of the data was done with a Waters system data module 730 (Pw = 16 and NR = 75). FT-IR analyses were performed on a 2000 Spectrum Perkin-Elmer spectrometer (resolution 4 cm-1; gain 1; range 5200 to 3891cm-1 (NIR analysis) and 4000 to 400 cm-1 (MIR analysis); 40 scans. The samples were analyzed by potassium bromide (KBr) technique (0.8: 400 mg in MIR analysis and 7:400 mg in NIR analysis). In this technique, a small amount, usually 1 to 3 mg, of finely ground solid sample, is mixed with approximately 400 mg powdered potassium bromide and then pressed in an evacuated die under pressure. The resulting discs are transparent and yield good spectra.

RESULTS AND DISCUSSION

Characterization of HMX/RDX by HPLC

The structures of HMX and RDX are illustrated in Figure 1.


Substance characterization with HPLC analysis is done by the comparison of retention times of the standard o-nitroaniline and explosives (HMX and RDX). Figure 2 shows a typical chromatogram where the substances RDX and HMX appear very well separated under the conditions used. The data represent the average of the percentage composition of three analysis (Table 1), showing a maximum standard deviation of 1.30.


Quantitative analysis of HMX/RDX by FT-MIR

The FT-MIR spectra of HMX, RDX and HMX/RDX samples with different contents are shown in Figure 3. An increasing in the intensity of the absorption11-13 at 783 cm-1 (d and g NO2) is observed as the RDX content increases, associated with the decreasing of the ring 13 absorption intensity at 917 cm-1 (n ring) as the HMX content decreases. These features may be a suitable analytical method to quantify the HMX/RDX content in the samples of BMX.


When more than one constituent is present, the FT-IR quantitative determination becomes more complex. This quantitative determination requires a measurement of peak heights from the infrared spectra and a calculation of the ratios between peaks. The ratio method is used for calculation of blends when one is unable to measure with accuracy the thickness of the sample14. Therefore, in the FT-MIR quantitative analysis of HMX/RDX samples, the absorbance values at 917 cm-1 (HMX) were related to those corresponding to the d and g NO2 absorption at 783 cm-1 (RDX). The baseline points at 986 and 820 cm-1 were considered in the calculations of absorbance values for the ring absorption at 917 cm-1. The calculations of absorbance values for d and g NO2 absorption at 783 cm-1 considered the baseline points at 820 and 720 cm-1.

Based upon in this simple examination of Beer's law, in accordance to the methodology used by Gedeon et al.14, an understanding of the limitations for the use of KBr pellets technique in quantitative analysis can be undertaken. To apply Beer's law to this analysis, the data obtained must be plotted of percent composition, then A917 / A783 ratios were plotted versus the composition ratios of the explosives. The same method was used for NIR analyses.

Table 2 presents the A917/A783 ratio as function of HMX/RDX ratio (wt-%), obtained by HPLC. The absorbance values represent the median (µ) of five analysis. According to Hórak15, with a low number of experimental values it may happen that the values of parameters and thus determined are subject to larger errors, which are difficult to determine due to a non-uniform distribution of random errors in the set. Then a difference assessment is made. The values of µ were determined by the median instead of the arithmetic mean. The standard deviation, of the median absorbance is calculated as follows15:

where is the assessed standard deviation of the basic set and is a quantitative measure of the precision for each individual measurement; n is the number of experiments.

where KR is the coefficient for the calculation of the average standard deviation from the variation range (for five experiments, KR = 0.430)15; and R is the difference between the largest and the smallest element (Xn - X1). is an evaluation of the precision of this median, that is, an evaluation of the result obtained from the treatment of a finite set of measurements which are repeated under completely identical conditions. The relative error for each sample was determined as follows:

Figure 4 shows the plot A917/A783 versus HMX/RDX ratio (wt-%). From the calibration curve (Table 2) taken by FT-IR/HPLC analysis, the following relationship (R=0.994) is proposed:


where y is the median relative absorbance (A917/A783) and x is the HMX/RDX ratio.

To calculate the HMX and RDX content, the median absorbance value (A917/A783) must be related to the equation 4 to found relative concentration [HMX/RDX]. After, the equation 5 must be used:

Quantitative analysis of HMX/RDX by FT-NIR

The FT-NIR spectra (region 5200 to 3891 cm-1) of HMX, RDX and HMX/RDX samples with highest contents HMX or RDX are shown in Figure 5. The criteria employed for the wavelength selections in the NIR method was similar to the one used in the MIR method. The analysis of the NIR spectra of HMX and RDX and its main peaks showed that the band at 4317 cm-1 is characteristic of RDX, and the band at 4412 cm-1, although near to RDX a band, was choosed as characteristic of HMX. According to Goddu17, these analytical absorptions are in the C-H combination band region. Then, both of these values were selected as the analytical peaks for the NIR methodology.


An increase in the intensity of the absorption at 4317 cm-1 is observed as the RDX content increases. On the other hand, the increase of the absorption intensity at 4412 cm-1 is observed when the HMX content increases. These features are the basis of a suitable analytical method to quantify the HMX/RDX content in the mixtures of these explosives.

For FT-NIR quantitative analysis in HMX/RDX samples, the absorbance values at 4412 cm-1 (HMX) were related to those corresponding to the absorption at 4317 cm-1 (RDX). The baseline points at 4554 cm-1 and 4240 cm-1 were established in calculations of the absorbance values.

Table 3 presents the A4412 /A4317 ratio as function of HMX/RDX ratio (wt-%) as obtained by HPLC. The absorbance values represent the median (µ) of five analysis. The standard deviation, , of the median absorbance and relative error were calculated as in MIR analysis. Figure 6 shows the plot of A 4412/ A4317 versus HMX/RDX ratio (wt-%). From the calibration curve (Table 3) taken by FT-IR/HPLC analysis, the following relationship (R=0.991) is proposed:


where y is the median relative absorbance (A 4412/A 4317) and x is the HMX/RDX ratio.

To calculate the HMX and RDX content, the median absorbance value (A 4412/A 4317) must be related to the equation 6 to found relative concentration [HMX/RDX]. After, the equation 5 must be used.

The precision data obtained from analyses by both procedures (MIR and NIR) are shown in Table 4. The samples BMX SU 10/99 (NIR analysis) and BMX SU 01/99 (MIR analysis) were used as test samples for the curves.

CONCLUSIONS

A new method by FT-MIR/NIR has been developed and compared to HPLC for determining the content of mixtures of HMX and RDX, high energetic compounds used in explosive compositions.

Since the main subject of this work was to provide a rapid method for quality control of laboratory synthesized HMX, one can consider that MIR and NIR methods fulfilled these requirements. NIR and MIR methods should be used where more accuracy and precision is required, since that deviations from the accurate values do not usually exceed 1-2% of the transmittance scale, according precision limits of used spectrometer. It was also observed that both MIR and NIR methods applied to this determination are comparable to each other in ease of use and faster and cleaner (without cleaning of the glassware) than the HPLC techniques. HPLC, MIR and NIR analysis showed good agreement. Based upon results obtained on BMX references values the present method can be used for control of the BMX compositions unknowns.

ACKNOWLEDGMENTS

We thank Mr. Gilson da Silva for suggestions on the final manuscript.

Recebido em 28/4/03; aceito em 8/3/04; publicado na web em 27/05/04

  • 1. Chan, M. L.; Roy, E. M.; Turner, A.; US pat. 5,316,600 1994
  • 2. Robbins, R.; Boswell, B. C.; US pat. 3,770,721 1973
  • 3. Mattos, E. C.; Tese de Mestrado, Instituto Tecnológico de Aeronáutica, Brasil, 2001.
  • 4
    Royal Ordnance, Explosives Division: Bridgwater, 1987, Commercial in Confidence; report unpublished.
  • 5. Mattos, E. C.; Viganó, I.; Dutra, R. C. L.; Diniz, M. F.; Iha, K.; Quim. Nova 2002, 25, 722.
  • 6. Grindlay, J. W.; Anal. Chem 1972, 44, 1676.
  • 7. Kaiser, M.; Propellants, Explos., Pyrotech 1998, 23, 309.
  • 8. Mattos, E. C.; Dutra, R. C. L.; Diniz, M. F.; Otani, C.; Iha, K.; Anais do III Encontro Técnico de Materiais e Química, Rio de Janeiro, Brasil, 1999.
  • 9. Kathryn, A. B. L.; Appl. Spectrosc 1993, 28, 231.
  • 10. Eisenreich, N.; Kull, H.; Hertz, J.; 25th International Annual Conference of ICT, Karlsruhe, Germany, 1994.
  • 11. Litch, H. H.; 2o Symposium on Chemistry Problems with the Stability of Explosives, Tyringe, Sweden, 1970.
  • 12. Achuthan, C. P.; Jose, C. L.; Propellants, Explos., Pyrotech. 1990, 15, 271.
  • 13. Smith, A. L.; Applied Infrared Spectroscopy; John Wiley & Sons: New York, 1979.
  • 14. Gedeon, B. J.; Ngyuen, R. H.; 128 th Meeting of rubber Division, Cleveland, Ohio, 1985.
  • 15. Hórak, M.; Vítek, A.; Interpretation and Processing of Vibrational Spectra, John Wiley & Sons: New York, 1978.
  • 16. Dutra, R. C. L.; Lourenço, V. L.; Diniz, M. F.; Azevedo, M. F. P.; Barbosa, R. V.; Soares, B. G.; Polym. Bull 1996, 36, 593.
  • 17. Goddu, R. F.; Adv. Anal. Chem. Instr. 1960, 1, 347.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      31 July 2004
    • Date of issue
      Aug 2004

    History

    • Accepted
      08 Mar 2004
    • Received
      28 Apr 2003
    Sociedade Brasileira de Química Secretaria Executiva, Av. Prof. Lineu Prestes, 748 - bloco 3 - Superior, 05508-000 São Paulo SP - Brazil, C.P. 26.037 - 05599-970, Tel.: +55 11 3032.2299, Fax: +55 11 3814.3602 - São Paulo - SP - Brazil
    E-mail: quimicanova@sbq.org.br